If you accept the machine from the shipping company, you are, in effect, saying that the machine is in good condition, and you must pay for the machine. Belshaw cannot pay for
shipping damage, because the freight company has accepted the machine from Belshaw in good condition, and is responsible for its safe delivery. For your protection, inspect the machine to see that no parts are bent, scratched, or otherwise damaged. If any damage has occurred in shipping, file a freight claim with the shipping company immediately.
EQUIPMENT RECORD
Please provide the information below when you correspond with us about your machine.
Purchased by _____________________________________________________________________
Installed by ______________________________________________________________________
Date of Installation ________________________________________________________________
Model number ___________________________________________________________________
Serial number
0103
MN-1316EN
Belshaw Bros., Inc. 1750 22nd Avenue South Seattle, WA 98144-4590
Phone: (206) 322-5474  Fax: (206) 322-5425
Toll Free: (800) 578-2547
Email: service@belshaw.com • http://www.belshaw.com
Page 4
Page 5

Contents

1 Installation 1 2 Operation 5
Melting and Filling 5 Filtering 7
3 Cleaning 10 4 Troubleshooting 12 5 Parts List 15
EZ18-2000 Shortening Melter Assembly (120V) 16 EZ18-2001 Shortening Melter Assembly (240V) 18 EZ24-2000 Shortening Melter Assembly (120V) 20 EZ24-2001 Shortening Melter Assembly (240V) 22 EZ34-2000 Shortening Melter Assembly (120V) 24 EZ34-2001 Shortening Melter Assembly (240V) 26 EZ24/34-1000 Heater Head Assembly 28
6 Appendix 30
Wiring Diagram (EZ18-4002) - 120V, 50/60 Hz, 1 Ph Insert Wiring Diagram (EZ18-4003) - 208/240V, 50/60 Hz, 1 Ph Insert
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN iii
Page 6

Figures

1-1. Front View. 1 1-2. Side View. 2 1-3. Top View, Heater Head. 2 1-4 Heater Head. 3 1-5 Elements & Kettle. 3 2-1. Packing Solid Shortening in the Kettle. 5 2-2. Cube Melter. 5 2-3. Installing the Cube Melter. 5 2-4. When to Add a Cube of Shortening. 6 2-4A. When to Add a Cube of Shortening. EZ-34 Only. 6 2-5. Positioning the Filter Frame for Melting. 6 2-6. When to Drain the Fryer. 7 2-6A. When to Drain the Fryer EZ-34 Only. 7 2-7. Positioning the Filter Assembly for Filtering. 7 2-8. Rinsing Hose. 8 3-1. Removing the Heater Head. 10 5-1. EZ18-2000 Shortening Melter Assembly (120V) 17 5-2. EZ18-2001 Shortening Melter Assembly (240V) 19 5-3. EZ24-2000 Shortening Melter Assembly (120V) 21 5-4. EZ24-2001 Shortening Melter Assembly (240V) 23 5-5. EZ34-2000 Shortening Melter Assembly (120V) 25 5-6. EZ34-2001 Shortening Melter Assembly (240V) 27 5-7 EZ24/34-1000 Heater Head Assembly 29
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
iv MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 7

Preface

The EZ Melt, Fill and Filter models EZ18, EZ24, and EZ34 are designed to be used with Belshaw fryers. It performs four functions:
It melts shortening It holds shortening It supplies shortening to the fryer kettle It filters used shortening for re-use
It is not designed to perform any other functions. The EZ Melt, Fill and Filter uses electrical elements to melt shortening.
The EZ Melt moves around on casters. It is meant to be used on the floor. The operator of the EZ Melt is expected to behave safely and to read this manual and follow its instructions and warnings.
Study the instructions and warnings in this manual carefully. A thorough understanding of how to install, maintain, and safely operate the EZ Melt, Fill and Filter will prevent production delays and injuries.
To use the EZ Melt safely, heed the following warnings and all other warnings that appear in this manual:
Make sure all hose connections are tight.
If you do not, you may be sprayed with hot shortening. This could result in serious burns.
Make sure no water gets into the
shortening. Water causes hot shortening to spatter, which could cause serious burns.
Make sure the EZ Melt kettle has enough
room in it before draining shortening from the fryer. If you do not, shortening may overflow the kettle and get on the floor, possibly causing slips, falls, injury, burns, or even death.
Make sure the nozzle of the supply hose
is securely mounted on the side of the fryer before turning on the pump. If you do not, hot shortening could spray you, resulting in serious burns. Also, shortening could get on the floor, possibly causing slips, falls, injury, burns, or even death.
Make sure that the system and the
shortening are cool before attempting any adjustments or repairs. If you do not, you may be burned.
Be careful never to get shortening,
water, or other materials on the floor. If anything does get spilled on the floor, mop it up immediately. If you do not, someone could slip or fall, be burned or injured, or even die.
To avoid damaging the EZ Melt, never
use force to assemble, disassemble, operate, clean, or maintain it.
To avoid electrocution, make sure that
the power cord is not frayed or cracked and that it does not pass through any water or shortening.
Make sure that the power cord is routed
so that no one will trip over it.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN v
Page 8
Page 9

1 Installation

To help familiarize you with the major parts of your EZ Melt model EZ18, EZ24, or EZ34, please study the photographs below.
handle heater head filter assembly kettle
casters
foot pedal
Figure 1-1. Front View.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 1
Page 10
hose connector
heater head power cord
frame with casters
foot pedal
filter assembly
kettle
cube melter
Figure 1-2. Side View.
heating element
kettle
hose connector supply hose
Figure 1-3. Top View, Heater Head.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
2 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 11
Reset button
Pump switch with pilot light
Heat switch with pilot light
Figure 1-4. Heater head
Bleeder
Pickup tube
Heating element
kettle
Figure 1-5. Elements and kettle.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 3
Page 12
Thoroughly clean your EZ Melt before using it. Refer to Section 3, “Cleaning,” for cleaning instructions.
WARNING
Moisture causes hot shortening to spatter,
which may cause serious injury. Thoroughly
dry the kettle and any other parts you wash.
WARNING
To avoid electrocuting yourself or damaging
the EZ Melt, never allow water, steam,
cleaning solution, or other liquid to enter the
heater head.
Make sure that the power requirements of the EZ Melt, shown on the data plate, match your power source.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
4 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 13

2 Operation

Melting and Filling

1. Completely cover the heating element with shortening. There are two ways to do this:
Pre-melt some shortening in a pan on the
stove and pour it into the kettle to cover the element.
Pack solid shortening tightly around the
heating element and bulbs. Do not leave any air spaces. Cover the heating element at least 2”/5 cm. (See Figure 2-1)
WARNING
Air spaces can cause the shortening to
overheat and catch on fire.
2. Install the cube melter in the kettle, opposite the heater head. Push the cube melter through
Figure 2-2. Cube Melter
Figure 2-3. Installing the Cube Melter.
3. Position the EZ Melt near the fryer.
4. Install the supply hose. Follow these steps:
the shortening so its legs rest on the bottom of the kettle. (See Figures 2-2 & 2-3.)
Figure 2-1. Packing Solid Shortening in the
Kettle.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 5
a. Attach the hose to the pump outlet by
hand-tightening the hose connector.
b. Mount the nozzle of the hose on the edge
of the fryer kettle with the opening inside the kettle.
Page 14
5. Make sure that the HEAT and PUMP
switches are in the OFF position. Connect the EZ Melt to the power source.
To avoid damaging the heating element, make
sure it is completely covered with shortening
before you turn the heater on.
6. Turn the machine on using the HEAT switch. When the heat is on, the heating element melts shortening at 200 F/93 C. The heat must also be on to operate the pump.
7. Turn the pump on using the PUMP switch.
8. When you want to supply shortening to the fryer, press the foot pedal.
WARNING
To avoid burning yourself, never touch the
nozzle while the machine is in use.
SIDE OF CUBE MELTER
BOTTOM OF KETTLE
Figure 2-4A. (
EZ34 ONLY) When to Add a
IF SHORTENING LEVEL IS HERE OR BELOW ADD ONE CUBE OF SHORTENING.
Cube of Shortening.
To add a cube of shortening, follow these steps:
1. Position the filter assembly so you can
add shortening. The edge of the kettle has one or two sets of holes in it. Use the set of holes that is nearer to the heater head. When two of the filter frame’s pins rest in these holes, the filter assembly hangs vertically. (See Figure 2-5.)
9. When the fryer has enough shortening in it, release the foot pedal.
10. As needed, add shortening to the kettle, one cube at a time. Always add a cube if the shortening level drops to the tops of the legs of the cube melter. (See Figure 2-4 & 2-4A.)
SIDE OF CUBE MELTER
BOTTOM OF KETTLE
IF SHORTENING LEVEL IS HERE OR BELOW ADD ONE CUBE OF SHORTENING
Figure 2-4. When to Add a Cube of
Shortening.
Figure 2-5. Positioning the Filter Frame for
Melting.
b. Place a solid cube of shortening on the
cube melter. Let one cube melt and be pumped out before adding another cube. Do not overload the EZ Melt.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
6 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 15

Filtering

1. Turn the fryer off. Allow the shortening to cool to 130 F/54 C.
WARNING
Hot shortening may cause serious injury.
2. Turn the EZ Melt off. Make sure that both the HEAT and PUMP switches are in the OFF position.
3. Make sure that the top of the cube melter is exposed.
If
Side of Cube Melter.
Bottom of kettle.
Figure 2-6. When to Drain the Fryer.
shortening level is here or below drain fryer.
4. Position the shortening filter assembly on
the EZ Melt kettle. The edge of the kettle has one or two sets of holes in it. Use the set of holes that is farther from the heater head. When two of the filter frame’s pins rest in these holes, the filter assembly rests horizontally on the end of the kettle. (See Figure 2-7.)
Figure 2-7. Positioning the Filter Assembly
for Filtering.
Side of cube melter.
If shortening level is here or below drain fryer.
Bottom of kettle.
Figure 2-6A.
(EZ-34 ONLY) When to Drain
the Fryer.
WARNING
When you begin to drain the fryer, the shortening in the EZ Melt must be shallow enough for the top of the cube melter to be
exposed. If the shortening is deeper it might
overflow when you drain the fryer, thus
causing burns or other serious injury.
5. Disconnect the supply hose from the hose connector. Hold the two ends of the hose up so shortening does not drip out. Hang hose vertically over a pan so the shortening will drip into the pan.
6. Attach the rinsing hose securely to the hose connector. (See Figure 2-8.)
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 7
Page 16
Figure 2-8. Rinsing Hose.
7. Position the EZ Melt so the filter is directly under the drain in the fryer kettle.
8. Reach under the table and slowly open the fryer’s drain valve.
9. Move the HEAT and PUMP switches of the EZ Melt to the ON position.
WARNING
Thoroughly clean and dry the floor if
shortening, water, or other materials are
spilled. Materials spilled on the floor may
cause serious injury and loss of life.
11. After you have rinsed all the loose particles out of the fryer kettle, release the foot pedal.
12. After the shortening has drained out of the fryer kettle and through the EZ Melt filter, close the drain valve.
13. Turn the EZ Melt off. Make sure that both the HEAT and PUMP switches are in the OFF position.
14. Disconnect the rinsing hose assembly. Hold the two ends of the hose up so shortening does not drip out. Hang the hose vertically over a pan so shortening will drip into the pan.
15. Bring the supply hose back to the EZ Melt, holding the two ends of the hose up so shortening does not drip out.
16. Securely attach the supply hose to the hose connector. Make sure the outlet nozzle is securely mounted to the fryer, with the opening inside the kettle.
10. Hold the insulated handle of the hose. Direct the nozzle into the fryer kettle. Press the foot pedal and rinse the kettle with shortening. Do not let shortening splash out of the kettle!
WARNING
To avoid burning yourself, never hold or
touch the metal portion of the nozzle while
the machine is in use. Wear protective
gloves.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
8 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
17. Move the HEAT and PUMP switches to the ON position. Press the foot pedal to supply filtered shortening to the fryer.
18. Before you filter shortening again, empty the EZ Melt filter. Follow these steps:
a. Allow the filter assembly to cool to the
touch.
b. Lift off the filter assembly, holding it by
the frame.
c. Invert the filter assembly over a sink or
garbage can and shake the sediment off of it. DO NOT rinse the filter.
Page 17
WARNING
Rinsing the filter could cause water to drop
into the kettle. Hot shortening could spatter
and cause serious injury.
d. Put the filter assembly back on the EZ
Melt.
To order replacement filters for your EZ Melt, call Belshaw.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 9
Page 18

Cleaning 3

Clean the EZ Melt after every use. Follow these steps:
WARNING
1. Turn on the heat and the pump.
2. Press the foot pedal to pump shortening out of the EZ Melt and into a metal container or fryer kettle.
3. When you cannot pump any more shortening out of the EZ Melt, release the foot pedal. Turn off the heat and the pump.
4. Disconnect the EZ Melt from the power source.
5. Allow the shortening in the EZ Melt kettle to cool to 115 F/46 C.
WARNING
Hot shortening can cause serious injury.
6. Clean the EZ Melt filter. Follow these steps: a. Allow the filter assembly to cool to the
touch.
Thoroughly clean and dry the floor if
shortening, water, or other materials are
spilled. Materials spilled on the floor may
cause serious injury and loss of life.
7. Remove the cube melter.
8. Loosen the two fasteners at the back of the heater head, lift it off the kettle and place it in a clean safe place. The foot valve and cord will unsnap from the frame. See Figure 3-1.
b. Lift off the filter assembly, holding it by
the frame.
c. Invert the filter assembly over a sink or
garbage can and shake the sediment off of it.
d. Unsnap the filter to remove it from the
filter frame.
e. Rinse the remaining shortening and
crumbs off of the filter.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
10 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Figure 3-1. Removing the Heater Head.
(Place heater head as shown above so no
damage is done to the element.)
Page 19
WARNING
Do not touch the heating element! It is very
hot and will burn you.
11. Remove the kettle from the frame. You must remove it from the rear.
12. Pour any shortening remaining in the kettle into a metal container. If it is too heavy or awkward for you to lift by yourself, get someone to help you.
WARNING
Thoroughly clean and dry the floor if
shortening, water, or other materials are
spilled. Materials spilled on the floor may
cause serious injury and loss of life.
13. Scrape out any residue and discard it.
14. Wash the kettle, the cube melter, and the filter frame with warm, soapy water.
15. Dry all the parts completely. The kettle and all other parts must be completely dry before you use the EZ Melt again.
WARNING
Moisture on parts causes hot shortening to
spatter, which may cause serious injury.
16. Re-assemble the EZ Melt.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 11
Page 20

Troubleshooting 4

This section is designed as an aid in trouble­shooting, not as a substitute for a qualified technician. You may encounter a problem with your EZ Melt that is not covered in this section, or you may try the remedies suggested here and find that they do not correct the problem. In either case, feel free to call Belshaw Bros. at (206)322-5474. One of our customer support representatives will be happy to help you. When you call, please specify the following:
The model number of the machine. The serial number of the machine. The voltage, phase, and hertz (cycle) of
the machine.
CAUTION
If you perform repairs yourself or have them
performed by anyone other than Belshaw Bros. or a service technician authorized by Belshaw Bros., you do so at your own risk.
For factory service, call us for a return goods authorization. Then send your machine to us, freight prepaid, with your instructions for service, your phone number, and the name of the person for us to contact when we have made a cost estimate. In most cases, the machine can be shipped back, freight collect, within five days.
To avoid down time, call us to see whether we have a machine we can loan to you while your machine is being serviced.
Ship machines in need of servicing to: Belshaw Bros., Inc.
1750-22nd Ave. S. Seattle, WA 98144 USA
Following is a troubleshooting chart to help you identify and solve some basic problems.
WARNING
Disconnect the machine from the power
source before disassembling, repairing, or
wiring.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
12 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 21
THE SHORTENING DOES NOT FLOW FREELY THROUGH THE FILTER SYSTEM
Possible Causes What To Do
The hose is crimped. Straighten the hose.
To avoid being burned, before doing any of the
following, turn off the EZ Melt and allow the shortening to cool.
The hose is clogged with shortening. Soak the hose in warm water to help release the
clogged shortening. Hang it up and let it dry before you use it again.
The drain tube is clogged with solid shortening. Remove the drain tube and soak it in warm water
to help release the clogged shortening.
The pickup tube is clogged with residue. Remove the pickup tube and clean it.
WARNING
THE PUMP MOTOR WILL NOT RUN
Possible Causes What To Do
The connection of the power cord to the power source is faulty.
Make sure the power cord is fully plugged in to a proper power source.
The circuit breaker has been tripped. Press the reset button.
If the problem persists, consult your Belshaw dealer, or call Belshaw.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 13
Page 22
This page has been left blank intentionally.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
14 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 23

5 Parts Lists

The following pages contain current lists of the parts that make up the EZ18, EZ24, and EZ34 models. Each list refers to an exploded-view assembly drawing. You can use the parts lists and assembly drawings as a reference to order replacement parts.
When ordering replacement parts, please provide the model number and serial number along with the correct electrical information about your equipment. Some of the part numbers vary according to the voltage, phase, cycle and serial number of the machine.
IMPORTANT
The parts lists and assembly drawings are
meant as guides. We cannot provide lists and
drawings for every possible configuration of
the EZ Melt models.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 15
Page 24
PARTS LIST 5-1
BILL OF MATERIAL ITEM QTY PART NO. DESCRIPTION FASTENERS
1 1 EZ18-0500 Kettle Frame, WLDT 2 1 EZ18-0502 Kettle, WLDT A 2 ¼-20 X ¼ Tek Screw 3 1 EZ18-0503 Filter Holder, WLDT 4 1 EZ18-0504 Cube Melter, Assy. 5 1 EZ24-1000 Motor Enclosure, Assy. (120v) 6 1 EZ6-0507 Tube Assy, Back Supply 1 EZ6-0510 Tube Assy, Front Assy. 7 1 SF100-0503 Rinsing Hose Assy. 8 1 SM100-0002 Filter Bag 9 1 SM100-0507RH Hose Supply, Assy. RH 1 SM100-0507LH Hose Supply, Assy LH 1 SM100-0510 Hose Supply Assy. 1 EZ18-0505 Hose Nozzle Assy. 10 1 EZ18-0011 Side Splash Guard 11 1 EZ24-0016 Label: EZ18 Name Plate 12 3 618-0116 Label: Caution; Hot 13 1 0158 Data Plate 14 3 990-0651 Wire Holder, ½”
EZ18-2000 SHORTENING MELTER ASSEMBLY (120V)
ITEM QTY. DESCRIPTION
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
16 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 25
FIGURE 5-1
EZ18-2000 SHORTENING MELTER ASSEMBLY (120V)
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 17
Page 26
PARTS LIST 5-2
BILL OF MATERIAL ITEM QTY PART NO. DESCRIPTION FASTENERS
1 1 EZ18-0500 Kettle Frame, WLDT 2 1 EZ18-0502 Kettle, WLDT A 2 ¼-20 X ¼ Tek Screw 3 1 EZ18-0503 Filter Holder, WLDT 4 1 EZ18-0504 Cube Melter, Assy. 5 1 EZ24-1001 Motor Enclosure, Assy. (240v) 6 1 EZ6-0507 Tube Assy, Back Supply 1 EZ6-0510 Tube Assy, Front Assy. 7 1 SF100-0503 Rinsing Hose Assy. 8 1 SM100-0002 Filter Bag 9 1 SM100-0507RH Hose Supply, Assy. RH 1 SM100-0507LH Hose Supply, Assy LH 1 SM100-0510 Hose Supply Assy. 1 EZ18-0505 Hose Nozzle Assy. 10 1 EZ18-0011 Side Splash Guard 11 1 EZ18-0016 Label: EZ18 Name Plate 12 3 618-0116 Label: Caution; Hot 13 1 0158 Data Plate 14 3 990-0651 Wire Holder, ½”
EZ18-2001 SHORTENING MELTER ASSEMBLY (240V)
ITEM QTY. DESCRIPTION
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
18 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 27
FIGURE 5-2
EZ18-2001 SHORTENING MELTER ASSEMBLY (240V)
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 19
Page 28
PARTS LIST 5-3
BILL OF MATERIAL ITEM QTY PART NO. DESCRIPTION FASTENERS
1 1 EZ24-0500 Kettle Frame, WLDT 2 1 EZ24-0502 Kettle, WLDT A 2 ¼-20 X ¼ Tek Screw 3 1 EZ24-0503 Filter Holder, WLDT 4 1 EZ24-0504 Cube Melter, Assy. 5 1 EZ24-1000 Motor Enclosure, Assy. (120v) 6 1 EZ6-0507 Tube Assy, Back Supply 1 EZ6-0510 Tube Assy, Front Assy. 7 1 SF100-0503 Rinsing Hose Assy. 8 1 SM100-0002 Filter Bag 9 1 SM100-0507RH Hose Supply, Assy. RH 1 SM100-0507LH Hose Supply, Assy LH 1 SM100-0510 Hose Supply Assy. 1 EZ24-0505 Hose Nozzle Assy. 10 1 EZ24-0017 Side Splash Guard 11 1 EZ24-0016 Label: EZ24 Name Plate 12 3 618-0116 Label: Caution; Hot 13 1 0158 Data Plate 14 3 990-0651 Wire Holder, ½”
EZ24-2000 SHORTENING MELTER ASSEMBLY (120V)
ITEM QTY. DESCRIPTION
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
20 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 29
FIGURE 5-3
EZ24-2000 SHORTENING MELTER ASSEMBLY (120V)
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 21
Page 30
PARTS LIST 5-4
BILL OF MATERIAL ITEM QTY PART NO. DESCRIPTION FASTENERS
1 1 EZ24-0500 KETTLE FRAME, WLDT 2 1 EZ24-0502 KETTLE, WLDT A 2 ¼-20 X ¼ TEK SCREW 3 1 EZ24-0503 FILTER HOLDER, WLDT 4 1 EZ24-0504 CUBE MELTER, ASSY. 5 1 EZ24-1001 MOTOR ENCLOSURE, ASSY. (240V) 6 1 EZ6-0507 TUBE ASSY, BACK SUPPLY 1 EZ6-0510 TUBE ASSY, FRONT ASSY. 7 1 SF100-0503 RINSING HOSE ASSY. 8 1 SM100-0002 FILTER BAG 9 1 SM100-0507RH HOSE SUPPLY, ASSY. RH 1 SM100-0507LH HOSE SUPPLY, ASSY LH 1 SM100-0510 HOSE SUPPLY ASSY. 1 EZ24-0505 HOSE NOZEL ASSY. 10 1 EZ24-0017 SIDE SPLASH GUARD 11 1 EZ24-0016 LABEL: EZ24 NAME PLATE 12 3 618-0116 LABEL: CAUTION; HOT 13 1 0158 DATA PLATE 14 3 990-0651 WIRE HOLDER, ½”
EZ24-2001 SHORTENING MELTER ASSEMBLY (240V)
ITEM QTY. DESCRIPTION
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
22 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 31
FIGURE 5-4
EZ24-2001 SHORTENING MELTER ASSEMBLY (240V)
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 23
Page 32
PARTS LIST 5-5
BILL OF MATERIAL ITEM QTY PART NO. DESCRIPTION FASTENERS
1 1 EZ34-0500 Kettle Frame, WLDT 2 1 EZ34-0502 Kettle, WLDT A 2 ¼-20 X ¼ Tek Screw 3 1 EZ34-0503 Filter Holder, WLDT 4 1 EZ34-0504 Cube Melter, Assy. 5 1 EZ34-1000 Motor Enclosure, Assy. (120v) 6 1 EZ34-0505 Hose Nozzle Assy. 7 1 EZ34-0027 Filter Bag 8 1 EZ34-0035 Side Splash Guard 9 1 EZ34-0036 Label: EZ34 Name Plate 10 3 618-0116 Label: Caution; Hot 11 1 0158 Data Plate 12 3 990-0651 Wire Holder, ½”
EZ34-2000 SHORTENING MELTER ASSEMBLY (120V)
ITEM QTY. DESCRIPTION
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
24 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 33
FIGURE 5-5
EZ34-2000 SHORTENING MELTER ASSEMBLY (120V)
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 25
Page 34
PARTS LIST 5-6
BILL OF MATERIAL ITEM QTY PART NO. DESCRIPTION FASTENERS
1 1 EZ34-0500 Kettle Frame, WLDT 2 1 EZ34-0502 Kettle, WLDT A 2 ¼-20 X ¼ Tek Screw 3 1 EZ34-0503 Filter Holder, WLDT 4 1 EZ34-0504 Cube Melter, Assy. 5 1 EZ34-1001 Motor Enclosure, Assy. (240v) 6 1 EZ34-0505 Hose Nozzle Assy. 7 1 EZ34-0027 Filter Bag 8 1 EZ34-0035 Side Splash Guard 9 1 EZ34-0036 Label: EZ34 Name Plate 10 3 618-0116 Label: Caution; Hot 11 1 0158 Data Plate 12 3 990-0651 Wire Holder, ½”
EZ34-2001 SHORTENING MELTER ASSEMBLY (240V)
ITEM QTY. DESCRIPTION
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
26 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 35
FIGURE 5-6
EZ34-2001 SHORTENING MELTER ASSEMBLY (240V)
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 27
Page 36
FIGURE 5-7
EZ24/34-1000 HEATER HEAD ASSEMBLY
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
28 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 37
PARTS LIST 5-7
EZ24/34-1000 HEATER HEAD ASSEMBLY
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 29
Page 38

6 Wiring Diagrams

This section contains the following wiring diagrams:
EZ18-4002 (120V, 50/60 Hz, 1 Ph) EZ18-4003 (208/240V, 50/60 Hz, 1 Ph)
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
30 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Page 39
Belshaw Bros., Inc. 1750 22 Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
nd
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 31
Page 40
Belshaw Bros., Inc. 1750 22 Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322­5425
nd
32 MN-1316EN EZ Melt Model EZ18, EZ24, EZ34
Loading...