This appliance can be used by children aged from 8
z
years and above and persons with reduced physical,
sensory or mental capabilities or lack of e
knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision. If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
There shall be adequate ventilation of the room when
z
the range hood is us
burning gas or other fuels.
The filter is made of high density aluminum.
z
z
Please do not use corrosive detergent for cleaning.
proper function of the unit is conditioned by the
regularity of the maintenance.
T
o protect the main body from the long time accumulation
z
of dirt, the cooker hood should be cleaned with
hot water with non-corrosive detergent every two
months or when required.
There is a fire risk if cleaning is not c
z
accordance with the instructions.
z
The air must not be discharged into a flue that is used
for ex
other fuels.
The minimum distance between the supporting surface
z
for the cooking vessels on the hob and the lowest part
of the range hood is 650
Regulations concerning the discharge of air have to be
z
fulfilled.
z
CAUTION
used with cooking appliances.
hausting fumes from appliances burning gas or
A
ccessible parts may become hot when
:
ed at the same time as appliances
mm.
xperience and
The
arried out in
2
Page 3
Safety Warning
The appliance is not intended for use by young children or infirm
persons without supervisions.
Young children should be supervised to ensure they do not play with
the appliance.
Plug the power cord to socket outlet with earthing continuity terminal.
The cooker hood is for home use only.
The cooker hood and its filter should be cleaned regularly
according to the instruction.
If there is any fault with the appliance, please call after-sale
service department.
Please keep the kitchen room ventilated.
Prior to any maintenance, cleaning operation, ensure the power is cut
off.
If the supply cord is damaged, it must be replaced by the manufacturer,
service agent or similarly qualified tepechnician in order to avoid a
hazard.The replaced power cord should be provided by manufacturer
or seller.
If the plug or cord is damaged, please call after-sale service center.
There is a fire risk if cleaning is not carried out in accordance with the
instruction.
In case of damaged connecting wire, please refer to the manufacturer,
after-sale service personnel or other qualified technicians.
Use the unit according to the instructions to avoid any fire hazard.
The exhaust air must not be introduced into a smoke flue or chimney
that is used for exhausting fumes from appliances burning gas.
Follow the local laws applicable for external air evacuation.
3
Page 4
Notice of Installation
It can not share the same air ventilation tube with other appliance
such as gas tube, warmer tube, and hot wind tube. There will be
hazard of underpressure, combustion impaired and harmful gases
drawn back.
The bending of ventilation tube should be ≥120°,parallel or above the
start point/should be connected to the external wall.
Please make sure the installation plate is
placed horizontally to avoid
rease collection at one end. See Fig.1.
g
Right Wrong
After installation, make sure that plug can be pulled out if necessary.
T he cooker hood should be plac
ed 650~750 mm up from the
cooking surface for safe and a good effect. See Fig.2.
There shall be adequate ventilation of the room when the cooker
hood is working.
4
Fig.1
Page 5
390-630
5
Fig.2
Installation plate
1 x
1
x Chimney installation plates
5 x Plastic expansion pipes
5 x Screws(ST5*50)
2
x Screws(M5*12)
4 x Screws(ST4.2*9.5)
Fig.3
Page 6
Installation
6
Accessories.
subject to actual demand.)
Fix installation plate and extension chim
Fix t
he exhaust pipe, See Fig.5.
Hang range hood on the installation plate. See Fig.6.
After connecting the exhaust pipe well,
he range hood from accidently sliding off the installation plate.
t
See Fig.7.
Fix the chimney. See Fig.8.
Fix the chimney. See Fig. .
See Fig.3. (Type and quantity of accessories is
ney installation plate, See Fig.4.
screws (M5*12) to prevent
lock
extension 9
Fig.5
Fig.4
Fig.6
Page 7
Fig.7Fig.8
7
Stop Low Mid High Light
Fig.9
Fig.10.1
Use
Speed adjustment. See Fig.10.1.
Press
Press the
Press the
Press the
Press the
Press it again and the lamps will be turned off.
top
button, the motor will stop running.
S
(speed) button, the motor runs at low speed.
Low
id
(speed) button, th
M
H
(speed) button,
igh
ight
L
button, the two lighting lamps will come on.
(For some models)
e motor runs at mid speed.
the motor runs at high speed.
Page 8
Maintenance
8
Contents
Cleaning of the filters
Removing the filters according to Fig.11.
Put into a dishwasher with detergent, set the temperature below
60 degrees.
Please do not use abrasive detergent for it will damage the hood.
Make sure that the hood is shut off before cleaning.
Fig.11Fig.1
Replacement of the carbon filters
Remove the filters see Fig.11.
The carbon filters are located at both end of the motor.
Turn the carbon filters until they are locked. S ee Fig.1 .
Apply reverse procedure to
It should be replaced after approximately 2-3 months of use.
The carbon fil er cannot be washed or recycled.
Carbon filter is not supplied with your appliance.
t
emove the carbon filter.
r
()
O
ption
2
a
l
2
222
Page 9
Trouble Shooting
9
Fault
on, but motor
Light
does not work.
light and motor
Both
o not work.
d
age.
Oil leak
ibration.
V
Insuf
ficient suction.
e machine inclines.
Th
use Solution
Ca
The blades are blocked.
The capacitor is damaged.
or is damaged. Replace motor.
The mot
The inter
disconnected. An unpleaseant smell
may be produced.
Apart from the above mentioned, check the following:
Light damaged.
Power cor
Outlet and the air ventilation entrance
are not tightly sealed.
Leakage from the connection of
U-shaped section and cover
The blade, if damaged, can cause
vibrating.
The motor is not tightly fastened.
The cooker hood is not tightly fi
The distance between the cooker
hood and the cooker top is too large.
T
or windows.
The fixing screws are not tight
enough.
The hanging screws ar
enough
nal wiring of motor is cut off /
Replace lights.
d loose.
oo much ventilation from open doors
.
Replace capacitor.
.
e not tight
Replace motor.
Connect the wires as per the
electric diagram.
Take down the outlet and seal with
glue.
Take U-shaped section down and
seal with soap or paint.
Replace the blade.
Fasten the motor tightly.
xed. Fixed the cooker hood tightly.
Readjust the distance.
Choose a new place to install the
appliance or close some doors /
windows.
Tighten the fixing screw and make
it horizontal.
Tighten the hanging screw and
make it horizontal.
Electrical Diagram
Electrical diagr
am see label on main body of the actual product.
222
Page 10
Main Parameters
egatloV
ed Power
Rat
ing Power
Light
or Power
Mot
Diamet
The
voltage is 220-240V
er of air tube
wolf riA
air flow parameter is tested under conditions of 230V 50Hz when the
~
50/60Hz and without carbon filters.
220-240V~50/60Hz
333W
2 X 1.5W
330W
150mm
800m /h
~
3
Disposal
Please
dispose of it at your local community waste collection /
recycling center and ensure it presents no danger to children
while being stored for disposal. The plug must be rendered
useless and the cable cut off to prevent misuse.
10
22
2
Page 11
Glen Dimplex Australia Pty Ltd
Unit 1, 21 Lionel Road
Mount Waverley VIC 3149
Customer Care
PH: 1300 556 816
Fax: 1800 058 900
Glen Dimplex New Zealand
38 Harris Road
East Tamaki
Auckland New Zealand
Customer Care
Ph: 09 274 8265
Fax: 09 274 8472
11
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.