The purpose of this manual is to provide necessary information for:
• Installation
• Operation
• Maintenance
CAUTION:
Read this manual carefully before installing and using the product. Improper use of the
product can cause personal injury and damage to property, and may void the warranty.
NOTICE:
Save this manual for future reference, and keep it readily available at the location of the
unit.
Safety
WARNING:
• The operator must be aware of safety precautions to prevent physical injury.
• Operating, installing, or maintaining the unit in any way that is not covered in this
manual could cause death, serious personal injury, or damage to the equipment. This
includes any modification to the equipment or use of parts not provided by Xylem. If
there is a question regarding the intended use of the equipment, please contact a
Xylem representative before proceeding.
• Do not change the service application without the approval of an authorized Xylem
representative.
CAUTION:
You must observe the instructions contained in this manual. Failure to do so could result
in physical injury, damage, or delays.
Safety terminology and symbols
About safety messages
It is extremely important that you read, understand, and follow the safety messages and
regulations carefully before handling the product. They are published to help prevent
these hazards:
• Personal accidents and health problems
• Damage to the product
• Product malfunction
2Suction Diffuser Plus INSTRUCTION MANUAL
Hazard levels
Hazard levelIndication
DANGER:
A hazardous situation which, if not avoided, will result in
death or serious injury
Introduction and Safety
Hazard categories
WARNING:
CAUTION:
NOTICE:
Hazard categories can either fall under hazard levels or let specific symbols replace the
ordinary hazard level symbols.
Electrical hazards are indicated by the following specific symbol:
Electrical Hazard:
These are examples of other categories that can occur. They fall under the ordinary
hazard levels and may use complementing symbols:
• Crush hazard
• Cutting hazard
• Arc flash hazard
A hazardous situation which, if not avoided, could result
in death or serious injury
A hazardous situation which, if not avoided, could result
in minor or moderate injury
• A potential situation which, if not avoided, could
result in undesirable conditions
• A practice not related to personal injury
User safety
General safety rules
These safety rules apply:
• Always keep the work area clean.
• Pay attention to the risks presented by gas and vapors in the work area.
• Avoid all electrical dangers. Pay attention to the risks of electric shock or arc flash
hazards.
• Always bear in mind the risk of drowning, electrical accidents, and burn injuries.
Safety equipment
Use safety equipment according to the company regulations. Use this safety equipment
within the work area:
• Hard hat
• Safety goggles, preferably with side shields
• Protective shoes
• Protective gloves
• Gas mask
• Hearing protection
Suction Diffuser Plus INSTRUCTION MANUAL3
Introduction and Safety
• First-aid kit
• Safety devices
Electrical connections
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local regulations. For more information about
requirements, see sections dealing specifically with electrical connections.
Precautions before work
Observe these safety precautions before you work with the product or are in connection
with the product:
• Provide a suitable barrier around the work area, for example, a guard rail.
• Make sure that all safety guards are in place and secure.
• Make sure that you have a clear path of retreat.
• Make sure that the product cannot roll or fall over and injure people or damage
• Make sure that the lifting equipment is in good condition and is properly sized for the
• Use a lifting harness and safety line, as required.
• Allow all system components to cool before you handle them.
• Make sure that the product has been thoroughly cleaned.
• Disconnect and lock out power before you install or service the suction diffuser.
• Check the explosion risk before you weld or use electric hand tools.
NOTICE:
Never operate a unit unless safety devices are installed. Also see specific information
about safety devices in other chapters of this manual.
property.
load to be lifted.
Wash the skin and eyes
Follow these procedures for chemicals or hazardous fluids that have come into
contact with your eyes or your skin:
ConditionAction
Chemicals or hazardous fluids in
eyes
Chemicals or hazardous fluids on
skin
Environmental safety
The work area
Always keep the station clean.
Waste and emissions regulations
Observe these safety regulations regarding waste and emissions:
• Appropriately dispose of all waste.
• Handle and dispose of the processed liquid in compliance with applicable
environmental regulations.
• Clean up all spills in accordance with safety and environmental procedures.
• Report all environmental emissions to the appropriate authorities.
1.Hold your eyelids apart forcibly with your fingers.
2.Rinse the eyes with eyewash or running water for at least 15 minutes.
3.Seek medical attention.
1.Remove contaminated clothing.
2.Wash the skin with soap and water for at least 1 minute.
3.Seek medical attention, if necessary.
4Suction Diffuser Plus INSTRUCTION MANUAL
Electrical installation
Recycling guidelines
Introduction and Safety
CAUTION: Radiation Hazard
Do NOT send the product to Xylem if it has been exposed to nuclear radiation, unless
Xylem has been informed and appropriate actions have been agreed upon.
For electrical installation recycling requirements, consult your local electric utility.
Always follow local laws and regulations regarding recycling.
Suction Diffuser Plus INSTRUCTION MANUAL5
Transportation and Storage
Transportation and Storage
Inspect the delivery
Inspect the package
1. Inspect the package for damaged or missing items upon delivery.
2. Note any damaged or missing items on the receipt and freight bill.
3. File a claim with the shipping company if anything is out of order.
If the product has been picked up at a distributor, make a claim directly to the
distributor.
Inspect the unit
1. Remove packing materials from the product.
Dispose of all packing materials in accordance with local regulations.
2. Inspect the product to determine if any parts have been damaged or are missing.
3. If applicable, unfasten the product by removing any screws, bolts, or straps.
For your personal safety, be careful when you handle nails and straps.
4. Contact the local sales representative if there is any issue.
6Suction Diffuser Plus INSTRUCTION MANUAL
Product Description
General description
The Suction Diffuser Plus is an angle pattern flow straightening fitting that combines a
diffuser-strainer orifice cylinder and full length straightening vanes to provide ideal flow
conditions for the pump suction. It saves space and money by eliminating the need for
long or short radius elbows, reducing flanges, and long lengths of pipe leading into the
suction side of the pump.
The Suction Diffuser Plus is designed for direct application to the pump suction and
provides ideal flow conditions for the pump, providing NPSH requirements are met.
The main features are:
• The integrated Flow Cone directs flow through the unit and into the pump suction
while working with the full length straightening vanes to create a uniform flow profile.
• The orifice cylinder has a free area equal to five times the cross section of the pump
suction opening and serves as a course strainer to protect the pump from large
sediment.
• A disposable fine mesh bronze start-up strainer is provided in conjunction with the
orifice cylinder to help protect the pump and clean the system by capturing small
particles and other debris during system commissioning.
The operation chapter of this manual contains data showing pressure drop conditions
across the Suction Diffuser Plus both with and without the mesh start-up strainer in place.
In order to determine the presence of the start-up strainer in a non-intrusive manner,
gauge ports, or taps, are located in the inlet and outlet flanges of the Suction Diffuser
Plus.
Product Description
Parts included in package
• Suction Diffuser Plus
• Instruction Manual
Additional parts needed:
• Flange gaskets
• Nuts and bolts
• Foot support
• Support leg
WARNING:
California Proposition 65 warning! This product contains chemicals known to the state of
California to cause cancer and birth defects or other reproductive harm.
NOTICE:
This product is not intended for potable water applications.
Declaration of Conformity
Xylem Inc. declares that the product listed conforms with the essential requirements and
provisions of Council Directive 97/23/EC, has been subject to internal manufacturing
checks with monitoring of the quality system, and conforms to following Sound
Engineering Practices (SEP) for use with Group 2 (non-hazardous) liquids. The suction
diffusers are not suitable for use with Group 1 (hazardous) liquids.
Suction Diffuser Plus INSTRUCTION MANUAL7
Product Description
Operation specifications
TypeMaximum working pressureMaximum operating temperature
Pump connection flanged or NPT and
system connection flanged, NPT, or
grooved
Pump connection grooved with
adapter flange and system
connection grooved
175 psi (1207 kPa)121°C (250°F)
300 psi (2069 kPa)121°C (250°F)
8Suction Diffuser Plus INSTRUCTION MANUAL
Installation
Installation guidelines
WARNING:
All procedures must be performed by qualified personnel.
• Before selecting a location for the pump Suction Diffuser Plus, make sure that there is
enough room to remove the Suction Diffuser Plus orifice cylinder. The length
requirements are Shown as Dimension "A" in the following table.
• If the pump pad is resilient mounted (rubber or spring), make sure that the pad is
large enough to include an adjustable Suction Diffuser Plus support leg.
• A support leg, not furnished, is required between the Suction Diffuser Plus and the
support foot, not furnished, to support the Suction Diffuser Plus and prevent strain on
the pump. Bosses are provided on the Suction Diffuser to locate the support leg and
facilitate mounting the Suction Diffuser Plus in any of three positions. The length of the
support leg varies depending on the pump centerline to mounting surface dimension.
The support leg can be made of Schedule 40 pipe. Refer to column "D" in the
following table for the required diameter of the support leg. Final height adjustment is
made with the adjustable support foot.
• When installing flanged model Suction Diffuser Plus , a criss-cross pattern should be
used when tightening the bolts. If PTFE tape is used when installing cast iron NPT
Models, be careful not to overtighten the connections. Cracks may develop in the
casting.
• Suction Diffuser Plus blowdown is best accomplished with the system connection in
the 12 o'clock position. Blowdown is less effective with the system connection in the 3
and 9 o'clock positions.
• When insulating the Suction Diffuser Plus after system installation, provisions should
be made to permit removal of the start-up strainer, orifice cylinder, and inlet vane
assembly.
• It is recommended that a pressure-vacuum gauge be installed in the integral 1/4" NPT
tapping to monitor pump inlet pressure.
Installation
Suction Diffuser Plus INSTRUCTION MANUAL9
1
2
3
4
5
6
7
8
BA
C
D
9
1
2
3
4
5
Installation
•
A = To remove diffuser
•
B = Distance to support leg
•
C = Foot support, not furnished
•
D = Support leg, not furnished
Figure 1: Working pressure 175 PSI (1207 KPa), 121°C
(250°F)
1.
System
2.
Warning label #V56871 installed here. If
missing it must be replaced.
3.
Inlet vanes
4.
Start-up strainer
5.
Orifice cylinder
6.
Cover
7.
Pump
8.
Gauge port
9.
Blowdown plug
1.
System
2.
Warning label #V56871 installed here. If
missing it must be replaced.
3.
Foot support, not furnished
4.
Adapter flange
5.
Pump
Figure 2: Working pressure 300 PSI (2069 KPa), 121°C
(250°F)
Be aware of water weight in the Suction Diffuser Plus and connected piping when
installing your system.
NOTICE:
Never use the suction diffuser itself as a form of piping support. Support suction diffusers,
valves, and piping according to the local building code. Failure to follow these
instructions may result in property damage.
Suction Diffuser Plus INSTRUCTION MANUAL11
A
B
B
A
Operation
Operation
Operation guidelines
Initial operation
The start-up strainer must be removed from the Suction Diffuser Plus within 24 to 48 hours
after the initial circulation and cleaning of the system. If left in place, a noticeable increase
in pressure drop will be observed as the fine strainer becomes clogged and starts
restricting flow through the Suction Diffuser Plus . See Service the suction diffuser plus
(page 14) in the Maintenance chapter of this manual for instructions for the removal of
this strainer.
Measure the pressure drop across the flange gauge ports on the inlet and outlet of the
Suction Diffuser Plus and, using the corresponding pump flow, compare the pressure
drop values with those published in section Pressure drop charts (page 12).
• If the measured pressure drop matches the higher pressure drop for the
corresponding flow shown in the submittal, this indicates that the start-up strainer is
still in place and should be removed. Follow the instructions in Service the suction
diffuser plus (page 14) in the Maintenance chapter of this manual to inspect the
orifice cylinder and remove any blockage that may be present.
• If the measured pressure drop matches the lower pressure drop value in the
submittal, this indicates that the strainer has already been removed.
Pressure drop charts
Performance characteristics measured using integrated PT ports with and without start-up
strainer.
• A = Pressure drop
• B = Flow
Figure 3: With start-up strainer
12Suction Diffuser Plus INSTRUCTION MANUAL
A
B
B
A
Operation
Continued operation
• A = Pressure drop
• B = Flow
Figure 4: Without start-up strainer
During system operation, measure the pressure drop across the inlet and outlet flanges of
the Suction Diffuser Plus and compare the data with the published pressure drop
information to detect if any blockage is present within the suction diffuser Plus. If the
measured data matches the higher pressure drop value for the system flow, there may be
a blockage inside.
Follow the instructions in Service the suction diffuser plus (page 14) in the Maintenance
chapter of this manual to inspect the orifice cylinder and remove any blockage that may
be present.
A pressure gauge installed in one of the Gauge ports of the Suction Diffuser Plus can also
warn of a blockage.
NOTICE:
Potential pump damage. Blockage in the suction diffuser can cause serious damage due
to cavitation within the pump. NPSH requirements for the pump must be met and
maintained. Periodically verify the pressure drop across the suction diffuser and inspect
the orifice strainer to prevent blockages that can cause cavitation. Failure to follow these
instructions could result in property damage.
Suction Diffuser Plus INSTRUCTION MANUAL13
Maintenance
Maintenance
Inspect the orifice cylinder
Periodic inspection of inlet vanes and cleaning of the orifice cylinder is required to guard
against damage to the pump. If damaged, they must be replaced.
Service the suction diffuser plus
Periodically inspect the Suction Diffuser Plus for signs of leakage or corrosion.
WARNING:
Risk for property damage, serious personal injury or death. You must replace the suction
diffuser if corrosion or leakage is found.
To service and inspect the Suction Diffuser Plus , complete the following steps:
1. Shut the pump off and isolate the Suction Diffuser Plus and pump from the system.
2. Allow system temperature to cool to below 38°C (100°F) to reach a safe handling
temperature.
WARNING:
High temperature and pressure hazard. Make sure that system
temperature is below 38°C (100°F) and system pressure is reduced
and maintained at zero before servicing the unit.
3. Open a drain valve in the isolated Suction Diffuser Plus piping and allow system
pressure to drop to zero. If fluid continues to flow from the drain valve, repack or
replace the isolation valves before proceeding.
4. Loosen the screws that secure the Suction Diffuser Plus cover and break it loose from
the body. Make certain all drainage stops before removing the screws and cover.
5. Grasp the inlet vane assembly with pliers and pull it out of the Suction Diffuser Plus
Body.
6. Remove start up strainer if still in place and inspect the orifice cylinder and inlet vane
assembly for damage. Replace damaged components with new components as
required.
7. Inspect the O-ring seal and replace with new component as required.
8. Reassemble the Suction Diffuser Plus and secure the cover with a criss-cross
tightening pattern.
9. Open isolation valves slowly and inspect the gasket area for leaks.
10. Return system to normal operation.
Service P/T ports or drain plugs
The P/T readout ports and drain plugs come pre-assembled with a leading industrial
thread sealant, Loctite, and are tightened to appropriate levels. Any
factory installed components breaks the original thread seal and could cause leakage.
This adjustment necessitates the removal, cleaning, and resealing of those parts per the
following instructions.
1. Remove the desired component from the Suction Diffuser Plus.
2. Clean off all of the old thread sealant using a wire brush and gentle abrasion if
necessary.
14Suction Diffuser Plus INSTRUCTION MANUAL
field adjustment of
Maintenance
If the component or Suction Diffuser Plus appears to have been damaged, replace it.
3. Starting with the second thread of the male Suction Diffuser Plus component, apply a
360º bead of Loctite 567 thread sealant/lubricant as shown. Follow Loctite handling
precautions as noted on the product label.
4. If Loctite is not available, it is recommended that you use RectorSeal No. 5 pipe thread
sealant for all non-glycol based applications, or any PTFE thread sealing tape. Be sure
to follow the manufacturer-specific handling precaution and application instructions
as noted on the product label.
5. Thread component into the Suction Diffuser Plus until it is finger tight.
6. Thread component into the valve until it is finger tight.
The use of thread sealants and lubricants on threads also provides lubricity. Overapplication of torque can damage the Suction Diffuser Plus port or component.
8. Properly assembled Suction Diffuser Plus components will immediately seal to
moderate pressure (6 bar [100 PSI] or less). For maximum pressure resistance, allow
the Loctite 5671 or RectorSeal No. 52 thread sealant to cure for 24 hours. PTFE tape
typically does not require curing to achieve maximum pressure resistance.
1
Loctite and Loctite 567 are registered trademarks of Henkel Ag & Co.
2
RectorSeal No.5 is a registered trademark of RectorSeal Corporation.
Suction Diffuser Plus INSTRUCTION MANUAL15
Product warranty
Product warranty
Commercial warranty
Warranty. For goods sold to commercial buyers, Seller warrants the goods sold to Buyer
hereunder (with the exception of membranes, seals, gaskets, elastomer materials,
coatings and other "wear parts" or consumables all of which are not warranted except as
otherwise provided in the quotation or sales form) will be (i) be built in accordance with
the specifications referred to in the quotation or sales form, if such specifications are
expressly made a part of this Agreement, and (ii) free from defects in material and
workmanship for a period of one (1) year from the date of installation or eighteen (18)
months from the date of shipment (which date of shipment shall not be greater than thirty
(30) days after receipt of notice that the goods are ready to ship), whichever shall occur
first, unless a longer period is specified in the product documentation (the “Warranty”).
Except as otherwise required by law, Seller shall, at its option and at no cost to Buyer,
either repair or replace any product which fails to conform with the Warranty provided
Buyer gives written notice to Seller of any defects in material or workmanship within ten
(10) days of the date when any defects or non-conformance are first manifest. Under
either repair or replacement option, Seller shall not be obligated to remove or pay for the
removal of the defective product or install or pay for the installation of the replaced or
repaired product and Buyer shall be responsible for all other costs, including, but not
limited to, service costs, shipping fees and expenses. Seller shall have sole discretion as to
the method or means of repair or replacement. Buyer’s failure to comply with Seller’s
repair or replacement directions shall terminate Seller’s obligations under this Warranty
and render the Warranty void. Any parts repaired or replaced under the Warranty are
warranted only for the balance of the warranty period on the parts that were repaired or
replaced. Seller shall have no warranty obligations to Buyer with respect to any product or
parts of a product that have been: (a) repaired by third parties other than Seller or without
Seller’s written approval; (b) subject to misuse, misapplication, neglect, alteration,
accident, or physical damage; (c) used in a manner contrary to Seller’s instructions for
installation, operation and maintenance; (d) damaged from ordinary wear and tear,
corrosion, or chemical attack; (e) damaged due to abnormal conditions, vibration, failure
to properly prime, or operation without flow; (f) damaged due to a defective power
supply or improper electrical protection; or (g) damaged resulting from the use of
accessory equipment not sold or approved by Seller. In any case of products not
manufactured by Seller, there is no warranty from Seller; however, Seller will extend to
Buyer any warranty received from Seller’s supplier of such products.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY AND ALL OTHER
EXPRESS OR IMPLIED WARRANTIES, GUARANTEES, CONDITIONS OR TERMS OF
WHATEVER NATURE RELATING TO THE GOODS PROVIDED HEREUNDER, INCLUDING
WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXPRESSLY DISCLAIMED
AND EXCLUDED. EXCEPT AS OTHERWISE REQUIRED BY LAW, BUYER’S EXCLUSIVE
REMEDY AND SELLER’S AGGREGATE LIABILITY FOR BREACH OF ANY OF THE
FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT
AND SHALL IN ALL CASES BE LIMITED TO THE AMOUNT PAID BY THE BUYER FOR THE
DEFECTIVE PRODUCT. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY OTHER FORM
OF DAMAGES, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL,
CONSEQUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT
NOT LIMITED TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE,
LOSS OF INCOME, LOSS OF BUSINESS, LOSS OF PRODUCTION, LOSS OF
OPPORTUNITY OR LOSS OF REPUTATION.
16Suction Diffuser Plus INSTRUCTION MANUAL
Consumer warranty
Product warranty
Warranty. For goods sold for personal, family or household purposes, Seller warrants the
goods purchased hereunder (with the exception of membranes, seals, gaskets, elastomer
materials, coatings and other "wear parts" or consumables all of which are not warranted
except as otherwise provided in the quotation or sales form) will be free from defects in
material and workmanship for a period of one (1) year from the date of installation or
eighteen (18) months from the product date code, whichever shall occur first, unless a
longer period is provided by law or is specified in the product documentation (the
“Warranty”).
Except as otherwise required by law, Seller shall, at its option and at no cost to Buyer,
either repair or replace any product which fails to conform with the Warranty provided
Buyer gives written notice to Seller of any defects in material or workmanship within ten
(10) days of the date when any defects or non-conformance are first manifest. Under
either repair or replacement option, Seller shall not be obligated to remove or pay for the
removal of the defective product or install or pay for the installation of the replaced or
repaired product and Buyer shall be responsible for all other costs, including, but not
limited to, service costs, shipping fees and expenses. Seller shall have sole discretion as to
the method or means of repair or replacement. Buyer’s failure to comply with Seller’s
repair or replacement directions shall terminate Seller’s obligations under this Warranty
and render this Warranty void. Any parts repaired or replaced under the Warranty are
warranted only for the balance of the warranty period on the parts that were repaired or
replaced. The Warranty is conditioned on Buyer giving written notice to Seller of any
defects in material or workmanship of warranted goods within ten (10) days of the date
when any defects are first manifest.
Seller shall have no warranty obligations to Buyer with respect to any product or parts of a
product that have been: (a) repaired by third parties other than Seller or without Seller’s
written approval; (b) subject to misuse, misapplication, neglect, alteration, accident, or
physical damage; (c) used in a manner contrary to Seller’s instructions for installation,
operation and maintenance; (d) damaged from ordinary wear and tear, corrosion, or
chemical attack; (e) damaged due to abnormal conditions, vibration, failure to properly
prime, or operation without flow; (f) damaged due to a defective power supply or
improper electrical protection; or (g) damaged resulting from the use of accessory
equipment not sold or approved by Seller. In any case of products not manufactured by
Seller, there is no warranty from Seller; however, Seller will extend to Buyer any warranty
received from Seller’s supplier of such products.
THE FOREGOING WARRANTY IS PROVIDED IN PLACE OF ALL OTHER EXPRESS
WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO ONE (1) YEAR FROM THE DATE OF INSTALLATION OR
EIGHTEEN (18) MONTHS FROM THE PRODUCT DATE CODE , WHICHEVER SHALL
OCCUR FIRST. EXCEPT AS OTHERWISE REQUIRED BY LAW, BUYER’S EXCLUSIVE
REMEDY AND SELLER’S AGGREGATE LIABILITY FOR BREACH OF ANY OF THE
FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT
AND SHALL IN ALL CASES BE LIMITED TO THE AMOUNT PAID BY THE BUYER FOR THE
DEFECTIVE PRODUCT. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY OTHER FORM
OF DAMAGES, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL,
CONSEQUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT
NOT LIMITED TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE,
LOSS OF INCOME, LOSS OF BUSINESS, LOSS OF PRODUCTION, LOSS OF
OPPORTUNITY OR LOSS OF REPUTATION.
Some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which may
vary from state to state.
Suction Diffuser Plus INSTRUCTION MANUAL17
Product warranty
To make a warranty claim, check first with the dealer from whom you purchased the
product or call the following number for the name and location of the nearest dealer
providing warranty service. For Goulds Water Technology contact 315-568-7123. For all
other products, contact 847-966-3700.
18Suction Diffuser Plus INSTRUCTION MANUAL
Xylem |’zīləm|
1) The tissue in plants that brings water upward from the roots
2) A leading global water technology company
We're 12,500 people unified in a common purpose: creating innovative
solutions to meet our world's water needs. Developing new technologies that
will improve the way water is used, conserved, and re-used in the future is central
to our work. We move, treat, analyze, and return water to the environment, and
we help people use water efficiently, in their homes, buildings, factories and
farms. In more than 150 countries, we have strong, long-standing relationships
with customers who know us for our powerful combination of leading product
brands and applications expertise, backed by a legacy of innovation.
For more information on how Xylem can help you, go to xyleminc.com
Xylem Inc.
8200 N. Austin Avenue
Morton Grove IL 60053
Tel: (847) 966–3700
Fax: (847) 965–8379
www.bellgossett.com
Visit our Web site for the latest version of this document
and more information
The original instruction is in English. All non-English
instructions are translations of the original instruction.