20
Bellfi res
English
Instructions for use and installation instructions
Igniting the fi re
• Open the gas supply valve in the gas pipe to the fi re.
• Switch the “O I” switch on the gas regulating block to the “I” position.
• Turn the motor-knob on the gas regulating block as far as it will go in a clockwise
direction. The switch will audibly ‘click’.
• Turn the operating knob on the gas control block to the MAN position. A recessed
switch within the knob will become visible.
• Press the recessed switch. Use a pen or similar instrument to do this.
Gas will now fl ow to the pilot light.
• While holding down the recessed switch, press the (square) piezo button several
times (the piezo button is alongside the “O I” switch) to ignite the pilot light.
Check whether the pilot light has been lit through the glass.
l Once the pilot light is lit, the recessed switch must be kept down for a further ten
seconds, after which it can be released.
Important: If the pilot fl ame goes out, then wait for
at least 5 minutes before repeating the
above procedure.
• Move the operating knob to the ON position. Depending on the position of the motorknob, the burner will either ignite or not.
• By turning the motor-knob anti-clockwise to the desired position, the burner will ignite
and the fl ame height can be controlled.
Important: • When the main burner is switched on by turning
the motor knob to the left, the burner must
ignite within 10 seconds.
If this does not happen, immediately close the
gas tap and warn the fi tter.
• If the main burner ignites with a pop; immediately
close the gas tap and warn the fi tter.
Extinguishing the fi re
• Turn the motor-knob on the gas regulating block as far as it will go in a clockwise
direction. The knob will audibly ‘click’. The burner is now switched off. The pilot light
will remain lit.
Switching off the appliance
• Press the “O I” switch on the gas regulating block to the “O” position.
The pilot light will be extinguished.
• If the gas fi re is not going to be used for a long period of time, it is
recommended to close the gas supply valve to the fi re.
Important: If the pilot fl ame goes out for any reason,
wait for 5 minutes before attempting to
re-light it.