Bellfires VENTO CLASSIC LARGE, VENTO CLASSIC MEDIUM Instructions For Use & Manual Daily Maintenance

INSTRUCTIONS FOR USE &
MANUAL DAILY MAINTENANCE
VENTO CLASSIC LARGE
Gas fi re with closed combustion system
Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re
This document is an essential part of your gas fi re.
Read it carefully before use of the gas fi re and keep it in a safe place!
Production date:
3
Bellfi res
English
Instructions for use
BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM:
Vento Classic Large (VCL)
4
Bellfi res
English
Instructions for use
5
Bellfi res
English
Instructions for use
CONTENTS
Page
1. WARRANTY TERMS ................................................................................. 7
2. INSTRUCTIONS FOR USE ....................................................................... 9
3. USING THE APPLIANCE FOR THE FIRST TIME ..................................... 20
4. DAILY MAINTENANCE ......................................
...........
.........
.................
... 20
5. ANNUAL MAINTENANCE .
..............
...................................
................
........ 21
6
Bellfi res
English
Instructions for use
7
Bellfi res
English
Instructions for use
1 WARRANTY TERMS
Interfocos
Warranty terms
Interfocos B.V. guarantees the quality of the supplied Bellfi res hearth and the quality of the materials used. All Bellfi res hearths are developed and manufactured according to the highest possible quality standards. If, despite all this, something should prove amiss with the Bellfi res hearth you have purchased, Interfocos B.V. offers the following manufacturer’s warranty.
Article 1: Warranty
1.1. If Interfocos B.V. determines that the Bellfi res hearth you have purchased is defective as a result of a fl aw in the construction or material, Interfocos B.V. guarantees to repair or replace the hearth free of charge, without charging any costs for labour or spare parts.
1.2. Repair or replacement of the Bellfi res hearth will be undertaken by Interfocos B.V. or by a Bellfi res dealer as designated by Interfocos B.V.
1.3. This warranty is supplementary to the existing legal national warranty of Bellfi res dealers and Interfocos B.V. in the country of purchase and is not intended to restrict your rights and claims based on the applicable legal provisions.
Article 2: Warranty conditions
2.1. Should you wish to claim under the warranty, please contact your Bellfi res dealer.
2.2. Complaints should be reported as quickly as possible after they have manifested themselves.
2.3. Complaints will only be accepted if they are reported to the Bellfi res dealer, together with the serial number of the Bellfi res hearth which is stated on the front of the instructions for use.
2.4. In addition, the original receipt (invoice, receipt, cash receipt) showing the date of purchase must also be submitted.
2.5. Repairs and replacements during the warranty period do not give any entitlement to an extension of the warranty period. After a repair or replacement of warranty parts, the warranty period shall be deemed to have started on the date of purchasing the Bellfi res hearth.
2.6. If a certain part is eligible for the warranty and the original part is no longer available, Interfocos B.V. shall ensure that an alternative part of at least the same quality shall be provided.
Article 3: Warranty exclusions
3.1. The warranty on the Bellfi res hearth ceases to be in effect if: a. it is not installed according to the supplied installation instructions, and to national and/or local regulations; b. it has been installed, connected or repaired by a non-Bellfi res dealer;
8
Bellfi res
English
Instructions for use
c. it has not be used or maintained according to the instructions for use; d. it has been changed, neglected or roughly treated; e. it has been damaged as a result of external causes (outside the hearth
itself), for example, lightning strike, water damage or fi re;
3.2. In addition, the warranty lapses if the original purchase receipt shows any change, deletion, removal or if it is illegible.
Article 4: Warranty area
4.1. The warranty is only valid in those countries where Bellfi res hearths are sold through an offi cial dealer network.
Article 5: Warranty period
5.1. This warranty will only be granted during the warranty period.
5.2. The body of the Bellfi res hearth is guaranteed for a period of 10 years against construction and/or material faults, starting from the moment of purchase.
5.3. For other parts of the Bellfi res hearth, a similar warranty applies from the moment of purchase for a period of one year.
5.4. For user parts such as glass, glass (cord), thermocouple and the interior of the combustion chamber, a similar guarantee is given until after the fi rst burning.
Article 6: Liability
6.1. A claim granted by Interfocos B.V. under this warranty does not automatically imply that Interfocos B.V. also accepts liability for any possible damage. The liability of Interfocos B.V. never extends further than that stated in these warranty conditions. Any liability of Interfocos B.V. for consequential damage is expressly excluded.
6.2. That stated in this provision is not valid if and to the extent that is derives from a mandatory provision.
6.3. All agreements entered into by Interfocos B.V. are, unless specifi cally stated otherwise in writing and to the extent that they are permitted based on applicable law, subject to the Conditions of the Dutch Metal and Engineering Association (METAALUNIEVOORWAARDEN), as fi led with the registrar of the Court of Rotterdam on 1 January 2008.
Interfocos B.V. Hallenstraat 17 5531 AB Bladel The Netherlands Tel: +31-497339200 Email: info@Bellfi res.com
Carefully retain the instructions for use; they show the serial number of the hearth. You will need this if you wish to claim under the warranty.
9
Bellfi res
English
Instructions for use
2 INSTRUCTIONS FOR USE
2.1 INTRODUCTION
Congratulations on your purchase of this modern Bellfi res gas fi re. This quality product will provide you with many years of enjoyment due to the fl ame effect and warmth that it provides. Please read the instructions for use carefully before using the appliance for the fi rst time. Keep this booklet in a safe place.
2.2 BUILT-IN PROTECTION OF THE APPLIANCE
The appliance is fully protected by means of a thermo-electric pilot light shut off in the event of a gas escape from the main burner.
2.2.1 Safety
Do not place embers, vermiculite granules, wood logs or pebbles against the pilot light burner. Make sure that the pilot fl ame can burn at all times freely over the main burner. Only in this way is proper ignition of the main burner ensured. Ignoring these directions could lead to a dangerous situation.
Do not place fl ammable objects within 100 cm of the appliance. Pay special attention to furnishings and ornaments around the fi re.
When igniting the pilot light and burner, always keep a minimum distance of 100 cm from the front of the appliance.
If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
It is essential that the appliance, the complete concentric fl ue system and the outlet are cleaned and inspected annually by a recognised fi tter/gas
specialist. The safe operation of the appliance will thus remain guaranteed. For this, please refer to the Installation instructions (Chapter 2: Maintenance), that are supplied separately with each appliance.
The gas fi re must never be used with the door open or the door glass removed.
10
Bellfi res
English
Instructions for use
Never place fl ammable material on the ceramic log set.
The fi lling of the main burner with embers, vermiculite granules, wood logs or pebbles may not under any circumstances be changed or added to.
Do not place easily-fl ammable materials, such as nylon clothing or fl ammable liquids, in the vicinity of the gas fi re.
Ensure at all times that children and other people who are not
aware of the operation of the gas appliance are only in the vicinity of the appliance exclusively under supervision.
Use a fi reguard to protect the people and children mentioned above against possible burns.
2.3 OPERATION: REMOTE CONTROL
11
Bellfi res
English
Instructions for use
2.3.1 General
Read these instructions carefully before lighting the fi re !!
The appliance is opperated by radio remote control. This comprises a hand-held transmitter and a receiver. The receiver is part of the gas control block assembly.
The receiver and the gas control block are behind the (white) panel door (operating unit) next to the appliance. Press the door inwards to open; this will release the catch and the door will spring out.
The hand-held transmitter and receiver are powered by batteries. Hand-held transmitter : 1x 9V battery. Receiver : 4x 1.5V battery type LR6 or AA.
Option: 6V adapter (230 VAC). Available from your fi tter.
Note: Hand-held transmitter and receiver are not interchangeable with previous models.
The pilot light is situated in the front of the burner, behind a cowl. Should the pilot light
go out, you must wait fi ve (5) minutes before attempting to re-ignite the fi re.
Important
Once the fi re is lit, it must burn at maximum for approx. 10 minutes to allow the chimney
to come up to temperature!
2.3.2 Hand-held transmitter
The remote control works by radio signal. The hand-held transmitter is confi gured in the factory with a unique signal code.
Figure 1: Hand-held transmitter
12
Bellfi res
English
Instructions for use
Figure 2: Receiver “RESET” button
Set the display
• Connect the batteries. By simultaneously pressing OFF and (small fl ame), can be switched from °F (and 12 hour clock) to °C (and 24 hour clock), or vice versa.
• The display will automatically return to mode after some time, but you may immediately return to mode by pressing the OFF button.
Set the current time
• By simultaneously pressing (large fl ame) and (small fl ame), the display fl ashes. You are in SET mode.
• While the screen is fl ashing, you can adjust the time.
• Press (large fl ame) to set the hour and (small fl ame) to set the minute.
• Wait or press OFF to return to mode.
Important: Setting up signal code before using the appliance for the fi rst time.
Before the appliance can be used, the receiver must fi rst learn the hand-held transmitter’s signal code.
• Press the “RESET
button on the receiver, and keep this pressed until 2 audio signals
are heard. See fi gure 2. Release the “RESETbutton after the second (somewhat longer) audio signal.
Press, within 20 seconds, the
(small fl ame) button on the hand-held transmitter,
until 2 short signals are heard. The signal code has now been set up on the receiver
.
If, however, a single long sound is heard, this means that setting the signal code has
failed or that the wiring has been connected incorrectly.
You only need to set up the signal code once. It is not necessary when changing the batteries of the hand-held transmitter or receiver.
13
Bellfi res
English
Instructions for use
Manual operation
Here you can turn the burner on and off, and adjust the height of the fl ames.
• Press (large fl ame) to turn on the burner and to increase the fl ame height.
• Press
(small fl ame) decrease the fl ame height to turn the burner off.
The pilot light will keep burning. (Stand-by position)
The appliance will automatically revert to stand-by if: ° the hand-held transmitter is outside the range of the receiver for more
than 6 hours.
° the batteries in the hand-held transmitter are almost depleted. ° the batteries in the receiver are fully depleted. (The pilot light will also be turned off.)
This also applies to the Thermostat and Timer operation.
When one of the buttons on the hand-held transmitter is pressed (except
the SET button), the transmission symbol
appears on the screen.
The receiver confi rms the transmission with an audio signal.
Operating day temperature thermostat
(Appliance is in the stand-by position and the pilot light is burning.)
Automatic temperature regulation of the pre-set day temperature. The room temperature is measured and compared with the pre-set day temperature. The fl ame height is automatically regulated so as to reach the pre-set day temperature. Also see: Setting the desired temperature.
Operating possibilities
It is possible to use the remote control in 3 ways to operate the appliance:
1 :
2 : and
3 :
You can cycle through the menu with operating possibilities by repeatedly depressing the SET button.
At the selected starting time (P1 or P2 ) or stopping time (P1 or P2
) is
also shown.
Returning to is also possible by pressing the (small fl ame) or
(large fl ame)
button.
14
Bellfi res
English
Instructions for use
Operating the night temperature thermostat (Appliance is in the stand-by position and the pilot light is burning.) Automatic temperature regulation of the pre-set night temperature. The room temperature is measured and compared with the pre-set night
temperature. The fl ame height is automatically regulated so as to reach the pre-set night temperature. Also see: Setting the desired temperature.
Timer operation
(Appliance is in the stand-by position and the pilot light is burning.)
Appliance functions automatically according to the two pre-set heating periods; P1 and P2. These heating periods repeat automatically every 24 hours. Also see: Programming the timer: P1 and P2.
The appliance works thermostatically at the pre-set starting times P1 and P2 and the room temperature is automatically regulated to the pre-set day temperature .
The appliance works thermostatically at the pre-set stopping times P1
and
P2
and the room temperature is automatically regulated to the pre-set night temperature . In order to allow the appliance to regulate the temperature at night, the night temperature must be set to at least 5°C.
If the setting is lowered to , the appliance will switch to stand-by at night. The appliance will automatically operate at the following day cycle .
N.B.: The pre-set temperature is shown on the screen every 30 seconds.
Setting the desired temperature
• Select the desired mode of operation or
by pressing the SET button
briefl y.
Press the SET button until the temperature indication on the display begins to fl ash.
• Set the temperature with (large fl ame) or (small fl ame).
• Wait or press the OFF button briefl y to go to mode.
• If the temperature control in should be off (lower battery consumption), decrease the night temperature until appears on the display.
Important: Place the hand-held transmitter in a place that is not
infl uenced by direct sunlight, draught, heat from the appliance and other heat sources.
15
Bellfi res
English
Instructions for use
Programming the timer: P1 and P2
• Select the desired mode of operation by pressing the SET button briefl y.
Press the SET button until P1 (heating period 1) and the time appear in the
display. (The time indication fl ashes.)
• Set the time for the beginning of the fi rst heating period by pressing (large fl ame) for houre and (small fl ame) for minute’setting.
• Press the SET button briefl y; P1
appears on the display. Set the time for the end
of the fi rst heating period.
• Press SET again to set the second heating period P2
(heat ON) and P2
(heat
OFF).
• Wait a moment or press OFF to switch back to
mode.
2.3.3 Operation (Remote Control)
Igniting the fi re
• Open the gas supply valve in the gas pipe to the fi re.
• Press the “O I” switch on the gas control block to the “I” position.
• Turn the operating knob on the gas control block to the ON position.
• Switch the hand-held transmitter to the
position.
• On the hand-held transmitter, press the OFF and (large fl ame) buttons simultaneously. A short tone will signal the start. Release the buttons. Short beeps will then follow until the pilot light and main burner are ignited. Once the main burner has been ignited, the fl ame height will automatically rise to the maximum position.
Important: If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
If the pilot light does not ignite after 3 ignition attempts; close the gas tap and warn the fi tter.
Once the pilot light is burning, the main burner must ignite within 10 seconds automatically. If this does not happen, immediately close the gas tap and warn the fi tter.
If the main burner ignites with a pop; immediately close the gas tap and warn the fi tter.
16
Bellfi res
English
Instructions for use
Figure 3: Gas regulating block; Operating Knob in ON-position
Motor-Knob (in maximum position)
Microswitch
Operating Knob
Connection Piezo Igniter (only for MANual control)
ON/OFF Switch
8-wire
Receiver Jack
• Possible error messages: * 3x short audio signal, audible when the motor-knob operates: Receiver batteries need changing soon (having heard this signal, the appliance can be ignited another ten times approximately). * 5 second unbroken tone: Error. For example, one of the cables may not be properly connected, the “O I” switch is not in the “I” position. * 5 short beeps: Ignition of the pilot light and main burner failed. Possible cause: air in the pilot light pipe.
Important: If the pilot fl ame goes out, then wait for at least 5 minutes before repeating the above procedure.
Setting the fl ame height / extinguishing the fi re
• After ignition, the burner automatically sets the fl ames to the maximum height
.
• Press button (small fl ame) to lower the fl ames and to turn off the main burner
(Extinguishing the fi re: small fl ame button: pilot light remains burning (stand-by position)!)
(Pressing briefl y the
(small fl ame) button gradually lowers the fl ames to the low
position.)
Pressing the (small fl ame) button twice automatically lowers the fl ames to the low
position. (When this happens, the fl ames will fi rst automatically go to maximum!)
This is indicated by “LO” on the display.
17
Bellfi res
English
Instructions for use
• Press button
(large fl ame) to increase the fl ame level and to turn on the burner
from the stand-by position. (Pressing briefl y the (large fl ame) button gradually increases the fl ames to the high position.) Pressing the (large fl ame) button twice automatically increases the fl ames to the
high position. This is indicated by “HI” on the display.
Important: If you turn on the main burner by pressing the (large fl ame) button, it must ignite within 10 seconds. If this does not happen, immediately close the gas tap and warn the fi tter.
If the main burner ignites with a pop; immediately close the gas tap and warn the fi tter.
Switching off the appliance
• Press the
(small fl ame) button to lower the fl ames or to switch off the main burner.
• Then press the OFF button to switch off the appliance, including the pilot light.
• Press the “O I” switch (on the gas control block) to the “O” position. This conserves
battery life.
• If the appliance is not to be used for some time, please close the gas supply valve in
the gas pipe.
Important: If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
Faults
• If the signals from the hand-held transmitter do not seem to be reaching the receiver,
the cause may be: * Spent batteries: replace the batteries. * An electronic problem: press the “RESET” button on the receiver.
• If the appliance regularly switches itself off, please contact your installer.
Replacing the batteries
• The hand-held transmitter/receiver batteries have a service life of approx. one year. We recommend you use alkaline batteries
.
Rechargeable batteries are not permitted.
• The batteries must be replaced whenever: 1 Hand-held transmitter : The battery symbol indicates this in the display.
: Battery fully charged
: Battery empty
2 Receiver: 3x short audio signal, audible when the motor-knob operates.
18
Bellfi res
English
Instructions for use
1 Hand-held transmitter:
* Open the cover on the back of the transmitter. * Carefully remove the 9V battery and disconnect it from the contact.
Do not pull the wires! * Connect the new battery and replace in the battery compartment. Close the cover.
2 Receiver: * Carefully pull the receiver assembly out of the compartment behind the (white) panel door.
* Open the cover. * Remove the batteries from the battery compartment. * Place four new 1.5V batteries (LR6 or AA type) as indicated in the battery
compartment. The negative end (-) of the battery must always be at the contact spring end of the compartment.
* Close the cover and place the receiver back in its holder.
• If the batteries are inserted incorrectly, the electronics or drive may be irreparably damaged.
• Only replace the batteries when the appliance has been completely switched off.
Figure 4: Gas regulating block; Operating Knob in MAN-position
2.3.4 Operation (Hand control)
In an emergency it is possible to operate the appliance manually. To do so, the ignition
(piezo) cable must fi rst be removed and transferred carefully to the piezo connector on the gas control block.
Motor-Knob (in maximum position)
Microswitch
Operating Knob (in Position for Manual Ignition)
Metallic Core for Manual Ignition (recessed switch)
Connection Piezo Igniter (only for MANual control)
ON/OFF Switch
8 Wire
Receiver Jack
Piezo button (only for MANual control)
19
Bellfi res
English
Instructions for use
Igniting the fi re
• Open the gas supply valve in the gas pipe to the fi re.
• Switch the “O I” switch on the gas regulating block to the “I” position.
• Turn the motor-knob on the gas regulating block completely to the right, in the OFF
position. The switch will audibly ‘click’.
• Turn the operating knob on the gas control block to the MAN position. A recessed
switch within the knob will become visible.
• Press the recessed switch. Use a pen or similar instrument to do this. Gas will now fl ow to the pilot light.
• While holding down the recessed switch, press the (square) piezo button several
times (the piezo button is alongside the “O I” switch) to ignite the pilot light.
Check whether the pilot light has been lit through the glass.
l Once the pilot light is lit, the recessed switch must be kept down for a further ten
seconds, after which it can be released.
Important: If the pilot fl ame goes out, then wait for at least 5 minutes before repeating the above procedure.
• Move the operating knob to the ON position. Depending on the position of the motor-
knob, the burner will either ignite or not.
• By turning the motor-knob anti-clockwise to the desired position, the burner will ignite
and the fl ame height can be controlled.
Important:
When the main burner is switched on by turning
the motor knob to the left, the burner must
ignite within 10 seconds.
If this does not happen, immediately close the
gas tap and warn the fi tter.
• If the main burner ignites with a pop; immediately close the gas tap and warn
the fi tter.
Extinguishing the fi re
• Turn the motor-knob on the gas regulating block as far as it will go in a clockwise
direction. The knob will audibly ‘click’. The burner is now switched off. The pilot light will remain lit.
Switching off the appliance
• Press the “O I” switch on the gas regulating block to the “O” position. The pilot light will be extinguished.
• If the gas fi re is not going to be used for a long period of time, it is recommended to close the gas supply valve to the fi re.
Important: If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
20
Bellfi res
English
Instructions for use
3 USING THE APPLIANCE FOR THE FIRST TIME
The gas fi re is coated with a lacquer layer resistant to high temperature. During the fi rst hours of operation, the burning in of the lacquer may result in an unpleasant smell. This is harmless, however. Operating the gas fi re at full capacity for a few hours, while ventilating the room, will eliminate the smell. After using your gas fi re for the fi rst few times, you may be aware of a light deposit on the inside off the glass. This is caused by the paint curing. Once your fi replace has cooled down, this deposit can be removed with glass cleaner or ceramic hob cleaner.
4 DAILY MAINTENANCE
• Ensure that as little dust, and as few particles of cigarette smoke, candles and oil
lamps as possible pollute the air in the room in which the appliance is used. Heating of these particles by the convection system of the appliance could lead to discoloration of the walls and ceiling. It is therefore very important to ensure that the room in which the appliance is located is suffi ciently ventilated. Regularly remove any dust deposits from behind the (white) panel door (operating unit) by means of a vacuum cleaner.
Important: • Regularly clean the glass on the inside of the appliance with glass spray or ceramic hob cleaner.
Attention!! If the glass is not cleaned on time,
this can result in becoming dull and diffi cult, if not impossible, to clean. (See installation instructions for dismantling/assembling the glass.)
• If the glass is broken or cracked, it must be
immediately replaced before operating the gas fi re again. Ceramic heat-resistant glass may not be placed in
the glass container, but must be included in normal household waste.
• If anything is spilt on the fi re, switch it off immediately and wait for it to cool
down suffi ciently before cleaning. Never use scouring powder, aggressive cleaners or fi re polish on the gas fi re. Use only a dry lint free cloth.
• Heat resistant lacquer in aerosols can be obtained from your distributor. During the yearly maintenance, the lacquer can be used to repair small areas of damage.
21
Bellfi res
English
Instructions for use
5 ANNUAL MAINTENANCE
It is essential that the appliance, the complete concentric
fl ue system (where possible) and the outlet are cleaned and inspected annually by a recognised fi tter/gas specialist. The safe operation of the appliance will thus remain guaranteed. Please refer also to the Installation instructions that are supplied separately with each appliance.
22
Bellfi res
English
Instructions for use
02 - 011112 - 331783
Your Bellfi res dealer
Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re
This document is an essential part of your gas fi re.
Read it carefully before installation and maintenance
of the gas fi re and keep it in a safe place!
INSTALLATION INSTRUCTIONS &
MANUAL FOR MAINTENANCE
VENTO CLASSIC LARGE
Gas fi re with closed combustion system
Production date:
3
Bellfi res
English
Installation instructions
BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM:
Vento Classic Large (VCL)
4
Bellfi res
English
Installation instructions
5
Bellfi res
English
Installation instructions
CONTENTS
Page
1. INSTALLATION INSTRUCTIONS .............................................................. 7
2. MAINTENANCE ......................................................................................... 61
3. FAULTS ...................................................................................................... 62
4. DISMANTLING
/ ASSEMBLING OF THE GLASS,
THE REGULATOR AND BURNER ..
...
.............................................
........
. 63
5. ELECTRICAL DIAGRAM .............................................................
.........
..... 65
6. DIMENSIONS ............................................................................................ 66
7. TECHNICAL DETAILS/REGULATIONS .................................................... 67
8. REPLACEMENT PARTS LIST .................................................................. 69
9. DISPOSAL OF PACKAGING AND APPLIANCE ....................................... 71
The installation must only be carried out by a
“Gas Safe Register” registered installation engineer.
IMPORTANT
6
Bellfi res
English
Installation instructions
7
Bellfi res
English
Installation instructions
1 INSTALLATION INSTRUCTIONS
1.1 GENERAL
The gas fi re must be positioned and connected as a “room sealed system” (balance fl ue) appliance by a “Gas Safe Register” registered gas installation engineer in accordance with the following installation instructions, nationally and locally applicable regulations (see “Technical Details/ Regulations” at the rear of this manual). If you have any queries regarding the installation, please consult your local gas company.
Important: Before beginning the installation, check that the details on the rating plate correspond to the gas type and pressure to which the appliance will be connected.
The appliance is factory set to the correct nominal heat input. The pilot light is set to the correct level of consumption.
The appliance has a Ø130 mm - Ø200 mm concentric connection for extracting the fl ue gases and supply of combustion air.
It is possible to install the gas fi re with either a wall or roof outlet.
The roof connection must be carried out using the concentric fl ue system Ø100 mm ­Ø150 mm. The fumes are exhausted naturally to the outside environment through the inner Ø100 mm pipe whereas the combustion air supply passes between the Ø100 mm and Ø150 mm pipes.
The wall connection must be carried out using the concentric fl ue system Ø130 mm ­Ø200 mm. The fl ue gases are evacuated outside by means of natural draft through the internal pipe of Ø130 mm, whereas the combustion air is supplied between the pipes of Ø130 mm and Ø200 mm. The wall outlet itself is Ø100 mm - Ø150 mm.
The gas fi re can be installed in a completely sealed or mechanically ventilated house without extra ventilation and/or fume extraction.
The gas fi re can be installed as an insertion into an existing open fi re place or as a built-in appliance in a new fi re place.
In order to prevent the fi replace heating up excessively, it must be properly ventilated by installing vents at the top and bottom of the fi replace.
If an existing chimney is to be used, please consult your installer fi rst. If the chimney was previously used for a wood or coal fi re, then it should be cleaned by an expert.
8
Bellfi res
English
Installation instructions
N.B. If any part is missing, please contact your dealer.
1.3 INCLUDED
1.2 CONCENTRIC FLUE SYSTEMS Ø100 MM - Ø150 MM AND
Ø130 MM - Ø200 MM : • Bellfi res (Muelink & Grol system)
• Poujoulat (PGI system)
• Ontop (Metaloterm US system)
The gas fi re, in combination with the concentric fl ue system [Ø100 mm - Ø150 mm] and/ or [Ø130 mm - Ø200 mm] (rigid and/or fl exible)
for the brands Bellfi res (Muelink & Grol system), Poujoulat (PGI system) or Ontop (Metaloterm US system), has been approved in accordance with the European CE-norm for gas appliances and may therefore be used only with these systems. The permitted components for these systems are listed in Chapter 1.6.2. The guarantee on the appliance lapses if it is installed, fully or partially, with other components or a different fl ue system. The concentric fl ue [Ø100 mm - Ø150 mm] and [Ø130 mm - Ø200 mm] systems can be used with either a newly-built or existing chimney.
Set documentation - Instructions for use
- Installation instructions
Attributes - Ceramic log set
9
Bellfi res
English
Installation instructions
1.4 OPTIONS AND ACCESSORIES
The following options and accessories can be supplied by your dealer:
Part no Accessorie
3........ Bellfi res (M&G) concentric fl ue system
See component summary
3........ Poujoulat (PGI) concentric fl ue system
See component summary
3........ Ontop (Metaloterm US) concentric fl ue system
See component summary
Part no
Option
311967 Mantle iron L = 1250 mm
10
Bellfi res
English
Installation instructions
1.5 PREPARATION FOR INSTALLATION
The following preparation must be carried out before the gas fi re can be installed.
1.5.1 Instructions for positioning the outlet
1.5.1.1 Positioning the outlet for correct operation:
Roof-mounted outlet:
Figure 1: Roof-mounted outlet
This must be positioned at least 0.5 m from the roof edge; the apex of the roof can be disregarded.
Wall-mounted outlet:
Figure 2: Wall-mounted outlet
This must be positioned at least 0.5 m from:
• the corner of the building.
• the roof overhang, the rain gutter.
• balconies etc., unless the exhaust construction
extends to at least the face of the protruding section.
>0.5 m
>0.5 m
11
Bellfi res
English
Installation instructions
1.5.1.2. Positioning the outlet to avoid affecting the surrounding area
All listed “distances” in this section are no more than guidelines. For the exact minimum “distances”, please consult your national and local directives.
“Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to:
A. A ventilation opening serving an occupied room, a toilet or a bathroom.
B. A heating air supply, when the supply fl ows through an occupied room.
C. A window that can be opened and that is near an occupied room, a toilet or a bathroom.
Roof-mounted outlet:
To avoid adverse effects Distance: outlet - A, B or C
At the same roof level. >3 m (*)
At a different roof level. >1 m (*)
At a lower positioned wall. >1 m
At a higher sloping surface. >3 m (**)
(*) If the required distance cannot be achieved, the outlet position rules take precedence.
(**) If the required distance cannot be achieved, the position of the outlet must be at least 1 m above the highest facade/roof.
12
Bellfi res
English
Installation instructions
Wall-mounted outlet:
To avoid adverse effects Distance: outlet - A, B or C
At walls in buildings with staggered Not permitted if A, B, or C are located heights. above the outlet.
On a wall - general. (*) Above the outlet: >2 m Below the outlet: >0.75 m Left and right of the outlet: >0.75 m
At <1 m from the roof overhang. >2 m
Beneath balconies, walkways etc. >2 m from the underside of the protruding balcony or walkway.
Beneath balconies, walkways >2 m etc. where the outlet extends to the front.
To the garden or on the terrace. >2 m to the outside space. (**)
With respect to a facing wall. >2 m (if the distance from the facing wall is less, the criteria detailed for “On a wall - general” apply).
Enquire at your local gas company for the regulations relating to outlets
positioned opposite each other and outlet(s) in facade(s) that form an angle.
(*) These minimum distances do not apply if there is an obstruction between the outlet and A, B and C that protrudes at least 0.5 m from the wall and has a length exceeding the distance.
(**) This distance is not required if the outlet is situated at least 1 m higher than the intended area of the outside space.
If the outlet has a clearance of less than 0.5 m from the hard surface of a public area at a height of less than 2 m, it must be fi tted with an effective protector. The mesh size of the guard must not affect the correct operation of the appliance.
13
Bellfi res
English
Installation instructions
Use as a wall support Use as a fl oor support
36
36
1.6 GENERAL SERVICES
1.6.1 The Fume Channel/Combustion Air Intake
The combined fume channel and combustion air intake requires one of the following concentric fl ue system confi gurations.
Important: Due to the high temperature of the outer walls
(approx. 150°C), no fl ammable materials may be located or used in the vicinity of the fl ue system. The complete fl ue system, must therefore be sleeved with a heat resistant material after assembly.
Ventilate the covered concentric fl ue by fi tting a grid near the fl oor and ceiling (on each fl oor).
Do not insulate the concentric fl ue.
Use the universal wall/fl oor support Ø150 mm to attach the covering of the concentric fl ue system [Ø100 mm - Ø150 mm], see 1.6.2, drawing number 36.
Figure 3: Application universal wall/fl oor support Ø150 mm
14
Bellfi res
English
Installation instructions
Figure 4: Vertical roof-mounted outlet without bend
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
Appliance: Concentric fl ue connection Ø130 - Ø200 mm
Item descriptions:
see 1.6.2
18
10, 11, 12, 13
1
4
Y
28
16
17
16
24
23
24
23
100
Appliance: Distance Y Assemble restriction plate: (min.-max.)
2,0 - 4,0 m Width: B = 65 mm Vento Classic Large 4,0 - 12,0 m Width: B = 90 mm
15
Bellfi res
English
Installation instructions
Figure 5: Vertical roof-mounted outlet with bend
(*) : (Y1 + Y2) : X > 2 : 1 (Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 1.6.2
16
23
Y
2
X
10, 11, 12, 13
14, 15
Y
1
4
1
28
23
23
17
24
100
Appliance: Distance Y1 (*) Distance X (*) Distance Y1 + Y2 (*) Assemble restriction (min.-max.) (min.-max.) (min.-max.) plate:
Vento Classic Large 1,0 - 11,0 m 0 - 3,0 m 1,0 - 11,0 m Width: B = 40 mm
16
Bellfi res
English
Installation instructions
Figure 6: Vertical chimney outlet using an existing lined chimney (Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
Item descriptions:
see 1.6.2
100
1
4
28
32
18
23
25
26
29
7
5
29
30
10, 11, 12, 13
Y
Appliance: Distance Y Assemble restriction plate: (min.-max.)
2,0 - 4,0 m Width: B = 65 mm Vento Classic Large 4,0 - 12,0 m Width: B = 90 mm
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
Appliance: Concentric fl ue connection Ø130 - Ø200 mm
17
Bellfi res
English
Installation instructions
Figure 7: Vertical chimney outlet using a lined chimney with a bend > 45° (Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
(*) : (Y1 + Y2+ Y3) : X > 2 : 1 (Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
Item descriptions:
see 1.6.2
Y
2
Y
1
10, 11, 12, 13
> 45°
X
Y
3
32 18 30
29
5
7
29 26
25
23
28
4
1
100
Appliance: Distance Y1 (*) Distance X (*) Distance Y1 + Y2 + Y3 (*) Assemble restriction (min.-max.) (min.-max.) (min.-max.) plate:
Vento Classic Large 1,0 - 11,0 m 0 - 3,0 m 1,0 - 11,0 m Width: B = 40 mm
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
18
Bellfi res
English
Installation instructions
Figure 8: Vertical chimney outlet using an existing unsound lined chimney or when no chimney liners are present (Flexible Ø100 mm / Ø150 mm)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 1.6.2
Y
7
6
8
1832
31
29
30
29
26
29
27
28 29
4
1
100
Appliance: Distance Y Assemble restriction plate: (min.-max.)
2,0 - 4,0 m Width: B = 65 mm Vento Classic Large 4,0 - 12,0 m Width: B = 90 mm
19
Bellfi res
English
Installation instructions
Figure 9: Vertical chimney outlet using an existing unsound lined chimney or when the chimney is unlined; with a bend >45
o
(Flexible Ø100 mm / Ø150 mm)
(*) : (Y1 + Y2+ Y3) : X > 2 : 1 (Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 1.6.2
Y
3
Y
2
Y
1
X
> 45°
6
8
7
31 29
32 18
30 29
26
29
27
28 29
4
1
100
Appliance: Distance Y1 (*) Distance X (*) Distance Y1 + Y2 + Y3 (*) Assemble restriction (min.-max.) (min.-max.) (min.-max.) plate:
Vento Classic Large 1,0 - 11,0 m 0 - 3,0 m 1,0 - 11,0 m Width: B = 40 mm
20
Bellfi res
English
Installation instructions
Appliance: Concentric fl ue connection Ø130 - Ø200 mm
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
Item descriptions:
see 1.6.2
Figure 10: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Wall Termination Position
100
4
28
1
Y
X
19
14
10, 11, 13
0.16 m
Appliance: Distance Y Distance X Assemble restriction plate: (min.-max.) (min.-max.)
Vento Classic Large 0,5 - 1,0 m 0 - 0,6 m -
21
Bellfi res
English
Installation instructions
Figure 11: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Appliance: Concentric fl ue connection Ø130 - Ø200 mm
Item descriptions:
see 1.6.2
RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
Wall
Termination Position
100
4
128
1
Y
X
19
14
110, 111, 113
0.16 m
Appliance: Distance Y Distance X Assemble restriction plate: (min.-max.) (min.-max.)
Vento Classic Large 0,5 - 1,0 m 0 - 0,6 m -
22
Bellfi res
English
Installation instructions
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Figure 12: Horizontal wall termination
Item descriptions:
see 1.6.2
RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm
Wall
Termination Position
100
4
128
1
Y
X
19
114
110, 111, 113
0.25 m
123
Appliance: Concentric fl ue connection Ø130 - Ø200 mm
Appliance: Distance Y Distance X Assemble restriction plate:
(min.-max.) (min.-max.)
1,0 - 3,0 m
0 - 3,0 m Width: B = 40 mm
Vento Classic Large
1,0 - 3,0 m 3,0 - 8,0 m -
23
Bellfi res
English
Installation instructions
AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm
1.6.2 Item descriptions for fi gures 4 t/m 12
FIG.
NO.
10
11
12
13
14
DESCRIPTION
Twin-wall balanced fl ue pipe, L = 500 mm, incl. and
Twin-wall balanced fl ue pipe, L = 1000 mm, incl. and
Telescopic twin-wall balanced fl ue pipe, L = min. 325 / max. 440 mm, incl. and
Adjustable length twin-wall balanced fl ue pipe, L = 500 mm, incl. and
Twin-wall balanced fl ue elbow
90°,
incl. and
BELLFIRES
ART. /
ORDER
NO.
302289
302290
302291
302292
302297
Color(*) Application
RVS antr.
RIGID FLEX
l
l
l
l
l
l
l
l
l
l
FIG. NO. DESCRIPTION
1 Gas fi re; Concentric fl ue connection Ø130/Ø200 mm
2 -
3 -
4 Restriction plate
(The different sizes restriction plates are supplied with every appliance)
5 Chimney, min. Ø150 mm internal, totally gas tight.
6 Chimney or fi reproof sleeving. Min. Ø160 mm internal.
7 Ø100 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI.
8 Ø150 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI.
9 -
24
Bellfi res
English
Installation instructions
FIG.
NO.
15
16
17
18
19
20
21
23
24
DESCRIPTION
Twin-wall balanced fl ue elbow
45°,
incl. and
Vertical (roof) termination kit, L = 1360 mm (vertical), incl. , and
Adjustable roof fl ashing. Roof pitch 20°
- 45° (**),
with lead fl ashing
Roof fl ashing for existing chimney or fl at roof
Horizontal (wall) termination kit, L = 600 mm (horizontally adjustable)), incl. , and one set of wall spacer plates
:
Stainless steel locking band
Ø150 mm, quick-fastening
: Silicone seal Ø150 mm
: Wall strap
Set of ceiling fi nishing plates / Fire stops
BELLFIRES
ART. /
ORDER
NO.
302298
302295
302212
302213
302296
302293
302210
302215
302214
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Color(*) Application
RVS
antr.
RIGID FLEX
25
Bellfi res
English
Installation instructions
FIG.
NO.
25
26
27
28
29
30
31
32
33
DESCRIPTION
Ceiling plate for transition Ø100 mm / Ø150 mm rigid -
Ø100 mm (fl ex.).
Stainless steel adapter piece (100) from fi re to fl exible, Ø100 mm external (rigid) x Ø107 mm internal (fl ex.). [appliance - Ø100 mm fl ex.] and [Ø100 mm rigid - Ø100 mm fl ex.].
Stainless steel adapter piece (150) fi re to fl exible, Ø148 mm external (rigid) x Ø148 mm internal (fl ex.) [appliance - Ø150 mm fl ex.].
Stainless steel locking band
Ø150 mm. For adapter 150 [appliance - Ø150 mm (fl ex.)], Screw-fastening
Stainless steel screws Ø3.5 mm x
9.5 mm. For securing the fl exible concentric fl ue. (Minimum 3 screws per connection)
Hose clamp Ø100 mm. (Minimum 2 per connection)
Hose clamp Ø150 mm. (Minimum 2 per connection)
Vertical (roof) termination kit, L = 610 mm (vertical), incl. and . For the fl exible fl ue system.
Concentric T-piece with gauging orifi ce, incl. and
BELLFIRES
ART. /
ORDER
NO.
302189
302278
302279
302217
303776
304041
304042
302307
302301
l
l
l
l
l
l
l
lll
l
l
l
l
l
l
l
l
l
l
l
l
Color(*) Application
RVS
antr.
RIGID FLEX
26
Bellfi res
English
Installation instructions
FIG.
NO.
34
35
36
DESCRIPTION
Concentric pipe with gauging orifi ce, L = 165 mm, incl. and
90° concentric bend with inspection panel, incl. and
Universal wall / fl oor support Ø150 mm
BELLFIRES
ART. /
ORDER
NO.
302302
302303
321948
l
l
l
l
l
l
Color(*) Application
RVS
antr.
RIGID FLEX
(*) : Color : RVS : Stainless steel self-colour, polished antr. : Anthracite colour lacquer, matt (**) : Adjustable roof fl ashing for a slope > 45° can be supplied on request.
When installing a balanced-fl ue “clo
sed” ga
s fi re in an existing chimney, ens
ure st
ainless
steel fl exible liners (
Ø100 mm or Ø130 mm)
conforming with BS 316 are used to conduct
the spent gases.
27
Bellfi res
English
Installation instructions
AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm
FIG NO.
100
110
111
113
114
115
119
DESCRIPTION
Concentric reduction of Ø130 / Ø200 mm Ø100 / Ø150 mm
Twin-wall balanced fl ue pipe, L= 500 mm, incl. and
Twin-wall balanced fl ue pipe, L= 1000 mm, incl. and
Adjustable length twin-wall balanced fl ue pipe, L= 500 mm, incl. and
Twin-wall balanced fl ue elbow 90°, incl. and
Twin-wall balanced fl ue elbow 45°, incl. and
Horizontal (wall) termination kit
,
L= 600 mm (h
orizontally adjustable), incl. , and one set of wall spacer plates
BELLFIRES
ART. /
ORDER
NO.
302319
302308
302309
302310
302314
302315
302313
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Color(*) Application
RVS antr.
RIGID FLEX
28
Bellfi res
English
Installation instructions
FIG.
NO.
120
121
123
124
126
127
128
129
130
131
DESCRIPTION
: Stainless steel locking band Ø200 mm, quick-fastening
: Silicone seal Ø200 mm
: Wall strap
Set of ceiling fi nishing plates / Fire stops
Stainless steel adapter piece (130) from fi re to fl exible,
Ø130 mm external (rigid) x Ø137 mm internal (fl ex.), [appli
ance - Ø130 mm fl ex.]
and [Ø130 mm rigid - Ø130 mm fl ex.]
Stainless steel adapter piece (200) from fi re to fl exible, Ø198 mm external (rigid) x Ø198 mm internal (fl ex.), [appliance - Ø200 mm fl ex.]
Stainless steel locking band Ø200 mm. For adapter 200. [appliance ­Ø200 mm fl ex.]. Screw-fastening
Stainless steel screws Ø3.5 mm x
9.5 mm. For securing the fl exible concentric fl ue. (Minimum 3 screws per connection)
Hose clamp Ø130 mm. (Minimum 2 per connection)
Hose clamp Ø200 mm. (Minimum 2 per connection)
BELLFIRES
ART. /
ORDER
NO.
302311
302248
302251
302250
302281
302282
302257
303776
304045
304046
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Color(*) Application
RVS
antr.
RIGID FLEX
29
Bellfi res
English
Installation instructions
FIG. NO.
10
11
12
14
15
DESCRIPTION
Twin-wall balanced fl ue pipe, L = 250 mm
Twin-wall balanced fl ue pipe, L = 450 mm
Twin-wall balanced fl ue pipe, L = 950 mm
Telescopic twin-wall balanced fl ue pipe, L = min. 390 mm / max. 640 mm
Twin-wall balanced fl ue elbow
90°
Twin-wall balanced fl ue elbow
45°
POUJOULAT
ART. /
ORDER
NO.
37100403
37100404
37100405
37100429
37100441
37100421
AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm
30
Bellfi res
English
Installation instructions
FIG.
NO.
16
17
DESCRIPTION
Twin-wall balanced fl ue elbow
30°
Twin-wall balanced fl ue elbow
15°
Vertical (roof) termination kit, L = 140 mm
Roof fl ashing, suitable for a brick roof, with a roof pitch of 15°- 30°
Roof fl ashing, suitable for a tiled roof, with a roof pitch of 15°- 30°
Roof fl ashing, suitable for a brick roof, with a roof pitch of 30°- 45°
Roof fl ashing, suitable for a tiled roof, with a roof pitch of 30°- 45°
POUJOULAT
ART. /
ORDER
NO.
37100411
37100401
37100654
45150171
45150170
45150172
45150173
31
Bellfi res
English
Installation instructions
FIG. NO.
18
19
20
23
24
34
DESCRIPTION
Roof fl ashing for existing chimney or fl at roof
Horizontal (wall) termination kit
,
L = min. 365 mm / max. 585 mm
Stainless steel locking band Ø150 mm, quick-fastening
Wall strap, Ø150 mm
Ceiling/wall plate with spacers and ventilation grooves
Set of ceiling fi nishing plates / Fire stops, suitable for a roof pitch of 0°- 10°
Set of ceiling fi nishing plates / Fire stops, suitable for a roof pitch of 10°- 30°
Set of ceiling fi nishing plates / Fire stops, suitable for a roof pitch of 30°- 40°
Set of ceiling fi nishing plates / Fire stops, suitable for a roof pitch of 40°- 50°
Concentric pipe with inspection opening, L = 250 mm
POUJOULAT
ART. /
ORDER
NO.
45150169
37100610
45150076
45150072
37100442
37100425
37100426
37100427
37100428
37100407
32
Bellfi res
English
Installation instructions
FIG.
NO.
36
36
37
100
101
DESCRIPTION
Roof support, (universal) Ø150 mm
Floor support, (universal) Ø150 mm
Adapter: Bellfi res Ø100-150 mm Poujoulat PGI Ø100-150 mm (Appliance 100/150 Poujoulat PGI 100/150)
Adapter: Bellfi res Ø130-200 mm Poujoulat PGI Ø100-150 mm (Appliance 130/200 Poujoulat PGI 100/150)
Concentric reduction of Poujoulat PGI Ø130-200 mm Poujoulat PGI Ø100-150 mm
POUJOULAT
ART. /
ORDER
NO.
45150165
45150081
37100611
37100614
37100613
33
Bellfi res
English
Installation instructions
AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm
FIG. NO.
110
111
112
114
115
POUJOULAT
ART. /
ORDER
NO.
37130403
37130404
37130405
37130429
37130441
37130421
DESCRIPTION
Twin-wall balanced fl ue pipe, L = 250 mm
Twin-wall balanced fl ue pipe, L = 450 mm
Twin-wall balanced fl ue pipe, L = 950 mm
Telescopic twin-wall balanced fl ue pipe, L = min. 390 mm / max. 640 mm
Twin-wall balanced fl ue elbow
90°
Twin-wall balanced fl ue elbow
45°
34
Bellfi res
English
Installation instructions
FIG.
NO.
115
119
120
123
124
DESCRIPTION
Twin-wall balanced fl ue elbow
30°
Twin-wall balanced fl ue elbow
15°
Horizontal (wall) termination kit
,
L = min. 425 mm / max. 585 mm
Stainless steel locking band Ø200 mm, quick-fastening
Wall strap, Ø200 mm
Ceiling/wall plate with spacers and ventilation grooves
Set of ceiling fi nishing plates / Fire stops, suitable for a roof pitch of 0°- 10°
Set of ceiling fi nishing plates / Fire stops, suitable for a roof pitch of 10°- 30°
Set of ceiling fi nishing plates / Fire stops, suitable for a roof pitch of 30°- 40°
Set of ceiling fi nishing plates / Fire stops, suitable for a roof pitch of 40°- 50°
POUJOULAT
ART. /
ORDER
NO.
37130411
37130401
37130610
45200076
45200072
37130442
37130425
37130426
37130427
37130428
35
Bellfi res
English
Installation instructions
FIG. NO.
DESCRIPTION
Concentric pipe with inspection opening, L = 250 mm
Roof support, (universal) Ø200 mm
Floor support, (universal) Ø200 mm
Adapter: Bellfi res Ø130-200 mm Poujoulat PGI Ø130-200 mm (Appliance 130/200 Poujoulat PGI 130/200)
POUJOULAT
ART. /
ORDER
NO.
37130407
45200165
45200081
37130615
36
Bellfi res
English
Installation instructions
AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm
FIG. NO.
10
11
12
14
15
DESCRIPTION
Adapter for Bellfi res appliances with Ø100-Ø150 mm concentric connection
Twin-wall balanced fl ue pipe, L = 250 mm
Twin-wall balanced fl ue pipe, L = 500 mm
Twin-wall balanced fl ue pipe, L = 1000 mm
Telescopic twin-wall balanced fl ue pipe, L = min. 60 / max. 250 mm
Twin-wall balanced fl ue elbow
90°
Twin-wall balanced fl ue elbow
45°
Twin-wall balanced fl ue elbow
30°
ONTOP
ART. /
ORDER
NO.
USA 10
US 25 10
US 50 10
US 100 10
USPP 10
USB 90 10
USB 45 10
USB 30 10
37
Bellfi res
English
Installation instructions
FIG. NO.
16
16
17
17
18
18
19
DESCRIPTION
Twin-wall balanced fl ue elbow
15°
Vertical (roof) termination kit, L = 375 mm, incl.
Storm collar Ø150 mm
Adjustable roof fl ashing. Roof pitch 20° - 45° (**), with lead fl ashing
Roof fl ashing plate for roof pitch 5°- 30°
Roof fl ashing for existing chimney or fl at roof
Roof fl ashing - Aluminium for existing chimney or fl at roof
Horizontal (wall) termination kit, L = 475 mm (horizontally adjustable))
,
incl.
ONTOP
ART. /
ORDER
NO.
USB 15 10
USDVC2 10
USSR 10
USLS 10
USDH 10
USDP 10
USDPAL 10
USDHC5 10
38
Bellfi res
English
Installation instructions
FIG.
NO.
20
21
23
23
24
24
25
25
DESCRIPTION
:
Locking band, quick-fastening
:
Cover band, screw-fastening
Wall strap, adjustable
Fitting bracket
Set of ceiling fi nishing plates / Fire stops / Centring plates
Roof support
Renovation set
Top of renovation set
ONTOP
ART. /
ORDER
NO.
USKB 10
USAB 10
USMB 10
USEB 10
USCP 10
USDQ 10
USSAN 10
USSAN1 10
39
Bellfi res
English
Installation instructions
FIG. NO.
25
28
34
35
DESCRIPTION
Bottom renovation set
Locking band
, screw-fastening
Concentric pipe with inspection panel, L = 250 mm
Concentric pipe with gauging orifi ce, L = 150 mm
90° concentric bend with inspection panel
Rosette smooth Ø150 mm
Wall plate large Ø150 mm, 300 mm
Spacer bracket
ONTOP
ART. /
ORDER
NO.
USSAN2 10
USKBS 10
USI 10
USEM 10
USBI 10
USR 10
USMPG 10
ASAH 10
40
Bellfi res
English
Installation instructions
AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm
FIG. NO.
10
11
12
14
DESCRIPTION
Adapter for Bellfi res appliances with Ø130-Ø200 mm concentric connection
Twin-wall balanced fl ue pipe, L = 250 mm
Twin-wall balanced fl ue pipe, L = 500 mm
Twin-wall balanced fl ue pipe, L = 1000 mm
Telescopic twin-wall balanced fl ue pipe, L = min. 60 / max. 250 mm
Twin-wall balanced fl ue elbow
90°
ONTOP
ART. /
ORDER
NO.
USA 13
US 25 13
US 50 13
US 100 13
USPP 13
USB 90 13
FIG.
NO.
DESCRIPTION
Concentric reduction of Ø100-Ø150 mm Ø130-Ø200 mm
ONTOP
ART. /
ORDER
NO.
USVG 10 13
41
Bellfi res
English
Installation instructions
FIG. NO.
15
16
16
17
17
DESCRIPTION
Twin-wall balanced fl ue elbow
45°
Twin-wall balanced fl ue elbow
30°
Twin-wall balanced fl ue elbow
15°
Vertical (roof) termination kit, L = 375 mm, incl.
Storm collar Ø150 mm
Adjustable roof fl ashing. Roof pitch 20° - 45° (**), with lead fl ashing
Roof fl ashing plate for roof pitch 5°- 30°
ONTOP
ART. /
ORDER
NO.
USB 45 13
USB 30 13
USB 15 13
USDVC2 13
USSR 13
USLS 13
USDH 13
42
Bellfi res
English
Installation instructions
FIG.
NO.
18
18
19
20
21
23
23
24
DESCRIPTION
Roof fl ashing for existing chimney or fl at roof
Roof fl ashing - Aluminium for existing chimney or fl at roof
Horizontal (wall) termination kit, L = 475 mm (horizontally adjustable))
,
incl.
:
Locking band, quick-fastening
: Cover band, screw-fastening
Wall strap, adjustable
Fitting bracket
Set of ceiling fi nishing plates / Fire stops / Centring plates
ONTOP
ART. /
ORDER
NO.
USDP 13
USDPAL 13
USDHC4 13
USKB 13
USAB 13
USMB 13
USEB 13
USCP 13
43
Bellfi res
English
Installation instructions
FIG. NO.
24
25
25
25
28
34
DESCRIPTION
Roof support
Renovation set
Top of renovation set
Bottom renovation set
Locking band
, screw-fastening
Concentric pipe with inspection panel, L = 250 mm
Concentric pipe with gauging orifi ce, L = 150 mm
ONTOP
ART. /
ORDER
NO.
USDQ 13
USSAN 13
USSAN1 13
USSAN2 13
USKBS 13
USI 13
USEM 13
44
Bellfi res
English
Installation instructions
FIG.
NO.
35
DESCRIPTION
90° concentric bend with inspection panel
Rosette smooth Ø200 mm
Wall plate large Ø200 mm, 350 mm
Spacer bracket
Concentric reduction of Ø130-Ø200 mm Ø100-Ø150 mm
ONTOP
ART. /
ORDER
NO.
USBI 13
USR 13
USMPG 13
ASAH 13
USVG 13 10
• The room-sealed gas appliances have been approved in combination
with the components of the concentric fl ue systems listed in this instruction book, according to the European CE norm for gas appliances and may therefore be used only with these components.
• The components of the concentric fl ue system of Bellfi res (M&G system), Poujoulat (PGI system) and Ontop (Metaloterm US system) may not be used together in one installation.
• Check whether the wall or roof termination kit to be used exactly matches one of those listed in this instruction book.
45
Bellfi res
English
Installation instructions
1.6.3 Gas connection
Operation (gas regulating block (and receiver)) outside the appliance (in the operating unit):
The gas connection is situated where the operating unit is built in near to the appliance.
Use only gas piping with a minimum diameter of 1/2” and a shut-off valve.
1.6.4 Operating unit
If the appliance is fi tted with an operating unit comprising gas control block and receiver, this will be located, once it has been built in, at a maximum of 50 cm from the left or right hand side of the appliance.
1.7 POSITIONING THE APPLIANCE
Important: The fi replace is constructed on a suffi ciently solid fl oor that
can bear the weight of the appliance.
Ensure a free space of at least 1 cm between the bottom of the appliance and the fl oor.
Ensure that the temperature of the fl oor under and in front of the appliance can never rise above 85°C! Make use of a temperature protection plate (of nonfl ammable material) on the fl oor if necessary. Take care with a fl oor made of a fl ammable material.
Never position the appliance directly against the rear wall, but always place an nonfl ammable insulation plate, at least 12 mm thick, between the appliance and the rear wall, with free space on either side of 2 cm. (Total ± 5 cm.) The rear wall must be made of nonfl ammable material.
Never use combustible materials during the installation.
Ventilate the fi replace, by allowing vents above and below the fi replace.
During installation of the gas fi re, a clearance of 3 mm should be maintained on all sides of the appliance to allow for expansion of the appliance during operation.
46
Bellfi res
English
Installation instructions
Do not insulate the appliance! Only the top and sides may be fi tted with a strip of white, loose insulation wool (heat-resistant to 1000°C), width 15 cm max. to protect the wall.
Do not use fi breglass or Rockwool, or any other sort of insulating material. These emit a pungent odour. This is considered extremely unpleasant. They may also cause discolouring of the column.
Flammable materials, such as curtains, should not be placed in the vicinity of the gas fi re. Minimum safe distance: 100 cm.
Place vents in the chimney-breast for intake and outlet of air
Figure 13: Use of ventilation of fi replace
47
Bellfi res
English
Installation instructions
Use the four adjustable legs to set the height of the appliance. See fi gure 14.
Figure 14: Adjusting the built-in height of the appliance
These adjustable legs can be reached after the window and the grill around the burner have been removed (see Chapter 4).
Position the gas supply pipe such that it can be easily mounted after installation.
Because the control system is outside the appliance, the gas pipe must lead to where the operating unit (built in), the gas regulating block (and the receiver) assembly are fi tted.
Move the appliance until it is ± 5 cm from the rear wall and ensure it is level. Place the nonfl ammable insulation plate (min. 12 mm) between the appliance and rear wall. The appliance may not be installed against a fl ammable rear wall.
Attach the appliance to the rear wall with 2 wedge bolts. Use the adjustable mounting brackets at the side of the appliance for this.
48
Bellfi res
English
Installation instructions
Figure 15: Operating unit
Frame with
door (white)
Operating unit
1.7.1 Connecting the gas
Important: During gas connection, take care not to twist the gas regulating block. Make sure that both the gas regulating block and the supply pipes are not subjected to stresses.
Appliance with operation in the separate operating unit (built in or otherwise):.
• The control unit and piping are supplied separately (fl at packed)
Remove the decorative edging and door of the operating unit. Fit the separate operating unit with the gas control block and receiver max. 50 cm from the appliance.
Adjust the operating unit using the two supports supplied.
Connect the supplied Ø8/(Ø12.4) mm stainless steel fl exible gas pipe on one side under the burner plate with the compression coupling there.
The connections for the main burner ((Ø8 mm stainless steel fl exible), pilot light (Ø4 mm stainless steel fl exible), thermocouple (thermocouple interrupter) and piezo cable can now be made at the gas regulating block in the operating unit. If the system has remote control, the piezo cable, the 8-terminal cable and the two thermocouple cables must be connected to the receiver (see fi gure 16 and Chapter 5: Electrical Diagram).
Important: Using the hand, screw the thermocouple connection (and thermocouple interrupter) into the back of the gas regulating block. Carefully tighten another half of a turn using a fork spanner.
See fi gure 16, 17 and Chapter 5.
49
Bellfi res
English
Installation instructions
Remote control Gas regulating block and receiver in operating unit
Figure 16: Remote control: Gas regulating block and receiver in operating unit
1 Gas regulating block 2 Gas supply connection 3/8” - Ø12 mm insertion 3 Burner piping connection Ø8 mm insertion 4 Thermocouple connection M 10x1 mm insertion 5 Pilot light piping connection Ø4 mm insertion 6 Receiver 7 Piezo cable connection
Important: After assembly, check,
all compression fi ttings
for leaks !
50
Bellfi res
English
Installation instructions
Remote control
The photo below shows how the piping for a remote control gas regulating block must be fi tted.
Figure 17: Gas regulating block Remote control
Side-inlet
Side-outlet
Bottom Outlet
Bottom Inlet
Inlet Pressure Tap
Outlet Pressure Tap
Thermo Unit Connection
Minimum Rate Adjustment Screw
Motor-knob
Operating-Knob
Pilot Gas Adjustment (with Screwdriver)
Maximum Rate Adjustment Screw
(Tab 2,8 x 0,8 mm) Connection piezo cable (Hand Control)
51
Bellfi res
English
Installation instructions
Appliance with operation in the separate operating unit (built in or otherwise).
• Gas control block and piping supplied as an pre-assembly.
First detach the bracket with the gas control block from the appliance. Fit the separate control unit max. 50 cm from the appliance. Fit the receiver in the top of the control unit.
Connect the piezo cable, the 8-terminal
cable
and
the two thermocouple cables to the receiver (see Chapter 5: Electrical
Diagram).
Carefully move the bracket with the gas regulating block and piping towards the control unit. Fit the bracket to the bottom of the control unit. Make sure that you do not damage any of the piping or detach any compression couplings while doing this. After you have done this, check the compression couplings for leaks.
General:
Route all piping and cables from the operating unit to the appliance through an easily accessible hollow cavity or a heat-resistant pipe of minimum Ø50 mm.
During subsequent installation of the operating unit, protect the gas regulating block and piping against encasement by cement etc.
Important: Cement and chalk can damage the piping and can, in turn, lead to gas leaks.
Figure 18: Gas regulating block Remote control
Motor-knob
Microswitch
Operating-Knob
(Remote control Hand control)
Connection
Piezo Igniter
(Hand control)
Piezo Igniter
(Hand control)
O I” Switch
Connection
Pilot Gas
8-Wire Receiver Jack
52
Bellfi res
English
Installation instructions
1.7.2 Connecting the concentric fl ue
Assemble the concentric fl ue system according to one of the examples in section 1.6.1, fi gure 4 to 12 inclusive. Make sure that all connections are completely gas tight.
1.7.3 Building in the appliance
The appliance is supplied from the factory with three decorative elements for the exte­rior of the fi replace:
• 1x horizontal support girder
• 1x vertical post Right
• 1x vertical post Left
Before building in the appliance, carefully place the “horizontal support girder” (1) and then the two “posts” (2 and 3) as shown in fi gure 19.
Note! : The “girder” and “posts” are made of a fragile fi reproof material. Place carefully !!! Wear protective clothing to prevent possible allergic reactions.
Figure 19: Placing the girder and the Right and Left posts
53
Bellfi res
English
Installation instructions
The appliance can now be built in.
First determine the places for the ventilation ducts (grills, at the top and bottom of the chimney breast).
The appliance can be built in using brickwork or by means of fi re-resistant plates that are screwed to a metal frame. You can, if you like, erect a natural stone mantelpiece in front of this.
The edge to which the materials for building in the appliance may be used:
Top of hearth: Top edge: transition metal - glass.
Left/right of hearth:
Up the to visible edge of the “post” L/R.:
transition metal - “post”.
Note ! : Ensure that there is a clearence of 2 mm between the brickwork/ fi reproof plate and the post to allow for expansion of the appliance due to heat. In addition, the “posts” should be at all time easily removable for maintenance to the appliance.
Bottom of hearth: Up to level with the top of the “support girder”. Note ! : Ensure that there is a clearence of
2 mm between the brickwork/ fi reproof plate and the “girder” to allow for expansion of the appliance due to heat. In addition, the girder should be at all time easily removable for maintenance to the appliance.
The net opening in the wall that arises is approximately: 874 x 674 mm [W x H]
The appliance is supplied with a straight pressed steel lintel as option to allow installa­tion against a fl at wall or in a fi replace.
A heat-resistant sealing cord should be placed between the top of the edge and the lo­wer side of the lintel to allow vertical expansion of the appliance and to prevent cracking the fi replace.
Do not use masking tape on the appliance when installing and plastering. Tape can damage the fi nish of the hearth.
54
Bellfi res
English
Installation instructions
The brickwork or the fi re-resistant sheet construction can now be continued to ceiling height.
If using other materials, such as stone or heat-resistant plating, you should follow the supplier’s instructions.
Once the fi replace has been fi nished, you can now, fi t the frame with the small door to the operating unit.
After installation in a new fi replace and/or applying new cement work, the appliance cannot be used for at least four weeks.
1.7.4 Checking the gas connection
After connection of the gas supply, check that all connections are completely gas tight using soapy water or a leak tester.
1.7.5 Decorative walls and grill
The appliance is supplied standard with a set of decorative walls and a grill. These are made of a fragile fi re-resistant material.
Place the pieces carefully in the order 1 to 5 as shown in fi gure 20.
Note ! : The decorative walls and the grill are made of
a fragile fi reproof material.
Place carefully !!!
Wear protective clothing to prevent possible allergic reactions.
Figure 20: Fitting decorative walls and grill
55
Bellfi res
English
Installation instructions
1.7.6 Positioning the ceramic log set
The appliance is delivered with a set of artifi cial wooden logs and embers.
Important: Carefully place the embers and set of logs on and around the main burner according to the directions in this chapter.
Do not place any embers or logs against the pilot light burner. Make sure that the pilot fl ame can burn at all times freely over the main burner. Only in this way is proper ignition of the main burner ensured. Ignoring these directions could lead to a dangerous situation.
Make sure that all burner orifi ces remains free
at all times!
The burner bed (with embers) and the positioning of the logs must not be changed.
Only use those items supplied! These been rigorously checked and the quantities adapted to the appliance.
Replacement parts are available from your dealer.
Fitting may only be carried out by a qualifi ed person.
Once the front has been removed along with the glass plate, the embers can be placed on the burner and the ceramic log set can be put in position. See also Chapter 4, “DISASSEMBLY / ASSEMBLY OF THE GLASS, THE REGULATOR AND BURNER”.
FITTING THE CERAMIC LOG SET.
NATURAL GAS APPLIANCE:
1. Carefully remove the embers (2x 125 gram) from the packaging and place them evenly on
and around the burner.
Note ! Small embers and their residue should not be scattered on the burner. This can cause a blockage on the burner orifi ces.
2. Place the logs on the burner: See fi gure 21.
Note ! : Small embers and their residue should not be scattered on
the burner. This can cause a blockage on the burner orifi ces.
• Embers must not be placed next to the pilot light burner.
• Important: make sure that all burner openings remain free !! Burner orifi ces, which are not open, could lead to a dangerous
situation.
56
Bellfi res
English
Installation instructions
Logs:
Log no Log no
Log no Log no
Log no Log no
Log no Log no
57
Bellfi res
English
Installation instructions
Keep the burner orifi ces unblocked!
Figure 21: Log set Vento Classic Large Position natural gas burner
Embers must not be placed next to the pilot light burner
Do not block the pilot light
58
Bellfi res
English
Installation instructions
PROPANE APPLIANCE:
1. Carefully remove the embers (1x 125 gram) from the packaging and place them evenly
on and around the burner (not on the holes!).
Please make sure that all burner orifi ces (small holes) are kept unblocked! Note ! Small embers and their residue should not be scattered on the burner. This can cause a blockage on the burner
orifi ces.
2. Place the logs around the burner: see fi gure 22. Don’t place any logs on the burner !
Keep the burner orifi ces unblocked!
Figure 22: Log set Vento Classic Large Position propane/butane burner
PROPANE: Keep the burner
orifi ces unblocked
Do not block the pilot light
Embers must not be placed next
to the pilot light burner
59
Bellfi res
English
Installation instructions
Figure 23: Positioning restriction plate
Once the logs have been positioned, replace the glass in the appliance,
following the instructions in chapter 4: DISMANTLING / ASSEMBLING THE GLASS, THE REGULATOR AND BURNER
.
1.7.7 Mounting fl ue gas restriction plate
Depending on the length and shape of the concentric fl ue system and the chimney construction, you should, if indicated, fi t a restriction plate with a certain width (B) into the ceiling of the combustion chamber. To do this, see the set-up options as listed in fi gure 4 through 12.
Important: Ensure that the correct fl ue gas restriction plate is mounted. Use of the correct fl ue gas restriction plate will provide
optimum effi ciency, fl ame effect and combustion. Mounting an incorrect fl ue gas restriction plate can result in damage to the gas fi re.
Assembly restriction plate
60
Bellfi res
English
Installation instructions
The following restriction plates are supplied:
VENTO CLASSIC LARGE
1.7.8 Checking the appliance following installation
After installation, visually check the gas fl ame. When the fi re is ignited, the fl ames should be short and blue/yellow in colour. These fl ames should gradually increase in height and become more yellow. When all fl ames are yellow, the gas fi re has reached the correct temperature.
THE GAS FIRE IS NOW READY FOR USE
Restriction plate: 1: Width: B = 40 mm 2: Width: B = 65 mm 3: Width: B = 90 mm
B
61
Bellfi res
English
Installation instructions
2 MAINTENANCE
2.1 ANNUAL MAINTENANCE
It is essential that the appliance, the complete concentric fl ue system (where possible) and the outlet are cleaned and inspected annually by a recognised fi tter/gas specialist.
The safe operation of the appliance will thus remain guaranteed.
Maintenance consists of the following:
• Remove fi rst the embers and logs set from the main burner and carefully clean these
with a soft brush.
• Clean and inspect (visually) the main burner, pilot light, combustion chamber,
fl ue system and combustion air intake. Dust can be removed using a vacuum cleaner.
• Clean the glass on the inside of the appliance with glass spray or ceramic hob
cleaner.
• After cleaning; Carefully replace the embers and logs set on and around the main burner according to the installation directions in this instruction booklet. Do not place any embers or logs against the pilot light burner. Make sure that
the pilot fl ame can burn at all times freely over the main burner. Only in this way is proper ignition of the main burner ensured.
Ignoring these directions could lead to a dangerous situation.
• Check the gas supply, fl ue system, and combustion air supply route for leaks.
• Check the correct operation of the gas regulating block, thermocouple
circuit and the ignition of the main burner.
• Check the gas inlet-pressure (both when the appliance is off and when it burns
at maximum) and the burner pressure.
• Check the complete concentric fl ue system including the outlet construction. A camera can be used to inspect the whole length of the fl ue gas outlet and the
combustion air intake.
Also check that all connections are secure.
62
Bellfi res
English
Installation instructions
3 FAULTS
3.1 POSSIBLE REASONS
Possible reasons for the gas fi re going out are:
• The concentric fl ue system is not installed according to one of the methods detailed in Paragraph 1.6.
• An incorrect “fl ue gas restriction plate” is fi tted.
• The pilot light extinguishes if fumes are not exhausted or are insuffi ciently exhausted.
• The pilot light is either dirty or defective.
• Insuffi cient gas pressure.
• (Internal) leak of the concentric fl ue system.
• Thermocouple voltage is too low. This is usually caused by insuffi cient heating of the thermocouple by the pilot light.
• Dirty electrical contacts in the thermo-electrical system; for example, the thermocouple connection.
• Batteries in receiver or remote control are fl at.
3.2 SAFETY MEASURE IN THE APPLIANCE
3.2.1 Thermo-electric pilot light shut off
The appliance is protected by means of a thermo-electric pilot light shut off in the event of a gas escape from the main burner.
63
Bellfi res
English
Installation instructions
4 DISMANTLING / ASSEMBLING OF THE GLASS, REGULATOR AND BURNER
4.1 DISMANTLING
1 Close the gas supply tap.
2 Remove the vertical Left and Right “posts” by lifting them and removing them sideways.
3 Remove the support “girder” by lifting it and pulling it out.
Note ! : The “girder” and “posts” are made of a fragile fi reproof material.
Place carefully !!!
Wear protective clothing to prevent possible allergic reactions.
4 Unscrew with several turns the 2 adjustment screws (to fi x the door) left and right below. Slide the left adjustment screw completely to the left and the right adjustment screw completely to the right.
5 The door is now only resting on two supports, Left and Right. Lift the door slightly, pull it forward, and lower it carefully into the space below. The door can now be removed from the front.
Use work gloves when removing the door!
6 Remove the log set and the embers.
7 Carefully remove the grill (around the burner). Avoid damaging the decorative walls!
8 Dismantling pilot light: Unscrew the 2 screws next to the pilot light. Remove the wind guard. Carefully pull the pilot light plate together with the pilot light upwards. You can now dismantle the fl exible pilot light pipe Ø4 mm, the thermocouple and piezo­ cable from underneath.
9 Dismantling bottom plate including main burner: Unscrew the 8 bolts on the bottom plate; 6 bolts around the burner and 2 bolts against the inside front, left and right of the pilot light. You can now slide the bottom plate backwards, so that you can loosen the
compression fi tting with the fl exible burner pipe Ø8 mm to the main burner at the front.
64
Bellfi res
English
Installation instructions
Figure 24: Vento Classic Large
10 Dismantling main burner: Unscrew the 4 bolts that connect the main burner to the bottom plate. Loosen the compression fi tting with the mainburner pipe. You can now remove the main burner.
11 Dismantle all connections to the operating unit of the gas regulator block; Thermocouple, fl exible pilot light pipe Ø4 mm and fl exible burner pipe Ø8 mm. Uncouple the piezo cable from the receiver. You can now remove all components.
4.2 ASSEMBLY
Assemble in the reverse order. Ensure that the bottom plate sealing cord and the glass plate mate correctly. Re-check all re-fi tted gas connections for leaks using soapy water or a leak tester.
Loosen screws (2x) Door is released, drops and can be removed
65
Bellfi res
English
Installation instructions
5 ELECTRICAL DIAGRAM
Thermo­ couple
Ignition cable
Antenna
O I” Switch
RECEIVER
Battery
Compartment
panel
4 AA Batteries
cable 2
cable 1
“red”
“black”
SPARK
SPARK
SW TC
SW
TC
GR
SW
MA
MO
Pilot
ON/OFF Switch
Thermocurrent interrupter Block
“red”
Button “Reset”
Motor-knob
Operating-Knob
Gas regulating block
“yellow”
Thermo ­current Interrupter Block
8 Wire Connecting Cable
66
Bellfi res
English
Installation instructions
6 DIMENSIONS
6.1 VENTO CLASSIC LARGE
Operating unit
Gas connection
67
Bellfi res
English
Installation instructions
7 TECHNICAL DETAILS/REGULATIONS
National installation regulations: Gas safety installation and use regulations 1984 plus all relevant
safety and building regulations concerning fi re installation
Model : VENTO CLASSIC LARGE
Country :
GB; G
reat Britain
/IE;
Ireland :
GB; G
reat Britain
/IE; I
reland
Product identifi cation no : 0063BQ3938 : 0063BQ3938 Type of appliance under CE-norm : C11 / C31 / C
31S
: C11 / C31 / C
31S
Category of appliance : I2H natural gas G20 : I
3B/P
butane/propane
G30/G31
Nominal heat input : 13.3 kW : Butane (G30) : 11.7 kW (Gross calorifi c value) Propane (G31) : 10.0 kW
Nominal heat output : 9.0 kW : 6.3 - 7.6 kW Effi ciency class : 2 (75%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 1.20 m
3
s
/hr. : Butane (G30) : 860 gr/hr.
Propane (G31) : 710 gr/hr.
Supply pressure : 20.0 mbar : Butane (G30) : 37.0 mbar Propane (G31) : 37.0 mbar
Burner pressure (max.) Hot : 12.0 mbar(*) : 28.0 mbar
Burner pressure (max.) Cold : 11.0 mbar(**) : 28.0 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (remote control) : Mertik GV 60 : Mertik GV 60
Main burner : 450 x 122 mm : 450 x 122 mm Primary air inlet main burner : 4x Ø8.5 mm : 8x Ø8.5 mm Main burner injector : no 380 : no 170 (= 1x Ø3.80 mm) (= 1x Ø1.70 mm) Pilot light burner : SIT 0.160.022 : SIT 0.160.022 Pilot light burner injector : no 51 : no 30 Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm Concentric fl ue system connection : Ø130 mm - Ø200 mm : Ø130 mm - Ø200 mm
68
Bellfi res
English
Installation instructions
Model : VENTO CLASSIC LARGE
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
Weight : 190 kg : 190 kg
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: Roof-mounted outlet : Concentric fl ue system Ø100 mm - Ø150 mm. Rigid and/or fl exible.
Horizontal wall outlet : Concentric fl ue system Ø130 mm - Ø200 mm. Rigid. With wall outlet, Ø100 mm-Ø150 mm.
Heat changing surface: Entire front of the appliance.
69
Bellfi res
English
Installation instructions
8 REPLACEMENT PARTS LIST
When requesting service or ordering replacement parts, please quote the model type and serial number. All parts listed in this manual may be ordered from a Bellfi res dealer.
No Article no Description
1 321339 Main burner Natural gas G20/G25 G20: 4xØ8.5 2 321646 Main burner Butane/Propane G30/G31 8xØ8.5
3 323064 Main burner injector Natural gas; no 380 (1x Ø3.80 mm) 4 319651 Main burner injector Butane/Propane; no 170 (1x Ø1.70 mm)
5 302416 Gas regulator block; GV 60 (M10 Thermocouple connection) 6 302083 Plug 3/8 GV 60 7 302084 Nut Ø8 mm for burner supply GV 60 8 302089 Olive Ø8 mm for burner supply GV 60 9 302085 Nut Ø12 mm for gas supply GV 60 10 302090 Olive Ø12 mm for gas supply GV 60 11 302086 Cut-off nipple Ø4 mm GV 60 12 302067 Cable (sw): Receiver - Thermocouple interrupter, L = 500 mm 13 302150 Switch with short length of cable to thermocouple interrupter and long length of cable (tc), L= 500 mm, to receiver 14 326287 Hand-held transmitter: Display screen: Temperature and two programmes 15 326288 Receiver GV 60 16 302068 8 Wire connecting cable L = 500 mm 17 321777 Piezo electrode + cable,
2.8 x 0.8 mm, L = 1500 mm
18 321926 Thermocouple M10 - 1500 mm 19 301970 T
hermocouple interrupter M10
20
302059 Pilot light set outer casing; SIT 0.160.022 21 301976 Pilot light nut; Ø4 mm 22 301977 Pilot light olive; Ø4 mm 23 301974 Pilot light injector; Natural gas; no 51 24 301921 Pilot light injector; Butane/Propane; no 30 25 302062 Nut piezo electrode 26 302061 Pilot light packing SIT no 160 series 27 322552 Pilot light pipe; Ø4 mm, L = 1500 mm, Flexible, Stainless steel 28 325750 Burner pipe; Ø8 mm, L = 1500 mm, Flexible, Stainless steel - 10 kW+
29 323390 Glass Vento Classic Large (840 x 715 x 4 mm)
70
Bellfi res
English
Installation instructions
No Article no Description
30 332581 Log set (7-parts) Natural gas incl. 2x 125 gram embers 31 332582 Log set (6-parts) Butane/Propane incl. 125 gram embers
32 301669 Tube ceramic glue
33 301593 Black fi bre glass tape 15 x 3 mm, adhesive 34 319664 Black fi bre glass tape 30 x 2 mm, adhesive
35 323601 Fire clay interior (4 plates and grill part) 36 323600 Fire clay exterior (2x posts and girder)
Appliance Log set
Set Log no
Art. no:
P 332581
Q 332582
Vento Classic Large Natural gas
Vento Classic Large Butane/Propane
Embers with Glow-effect Anthracite
1
331357
1x
1x
2
331358
1x
1x
3
331359
-
-
4
331360
2x
1x
6
331362
1x
1x
7
331363
1x
1x
8
331364
-
-
5
331361
1x
1x
Bag: 125 gr.
301863
2x
1x
71
Bellfi res
English
Installation instructions
9 DISPOSING OF PACKAGING AND APPLIANCE
The appliance comes in recyclable packaging. This can include:
• Cardboard
• Wood
• Plastic
• Paper
Such materials must be disposed of responsibly, in line with local regulations.
Batteries should be disposed of as chemical waste. Batteries must be disposed of responsibly, in line with local regulations.
The authorities or fi tter can provide you with information on responsible disposal of obsolete appliances.
03 - 011112 - 331795