Bellfires Topsham Tunnel, Kent, Retro Bell Intermediate, Jersey, Retro Bell Small Installation Instructions And Instructions For Use

...
INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE
Gas fi res with closed combustion system
Original Bell-series - Retro Bell-series
Horizon Bell Medium / Small-series - Corner Bell Small L/R
Vertical Bell-series - View Bell-series
Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re
This document is an essential part of your gas fi re.
gas fi re and keep it in a safe place!
www.tapis.pl
3
Bellfi res
English
Instructions for use and installation instructions
BELLFIRES GAS FIRES WITH CLOSED COMBUSTION SYSTEM:
Original Bell - series:
Derby (DY) Derby II (DY II) Jersey (JY) Flat Bell (FB) Topsham (TS) Topsham Tunnel (TST) York (YK) Kent (KT)
Retro Bell - series: Retro Bell Intermediate (RBI) Retro Bell Small (RBS)
Horizon Bell Medium / Small - series: Horizon Bell Medium (HBM) Horizon Bell Small (HBS) Horizon Bell Small Tunnel (HBST)
Corner Bell - series: Corner Bell Small L/R (CBS - L/R)
Vertical Bell - series: Vertical Bell Large (VBL) Vertical Bell Large Tunnel (VBLT) Vertical Bell Small (VBS)
View Bell - series: View Bell Small (VWBS) View Bell Vertical (VWBV)
4
Bellfi res
English
Instructions for use and installation instructions
5
Bellfi res
English
Instructions for use and installation instructions
CONTENTS
Page
1. WARRANTY TERMS ................................................................................. 7
2. INSTRUCTIONS FOR USE ....................................................................... 9
3. INSTALLATION INSTRUCTIONS .............................................................. 22
4. MAINTENANCE ......................................................................................... 60
5. FAULTS ...................................................................................................... 61
6. ELECTRICAL DIAGRAM ........................................................................... 62
7. DIMENSIONS ............................................................................................ 63
8. TECHNICAL DETAILS/REGULATIONS .............................................
..
..... 73
9. REPLACEMENT PARTS LIST ..................................................
......
.......... 85
10. DISPOSAL OF PACKAGING AND APPLIANCE
......................................
. 88
6
Bellfi res
English
Instructions for use and installation instructions
7
Bellfi res
English
Instructions for use and installation instructions
Bellfi res gas fi re
Warranty
Bellfi res guarantees the quality of the supplied hearth and the quality of the materials used.
This warranty runs for a period of twelve (12) months from fi rst use of the hearth and covers defects which are a result of construction faults or the failure of component parts.
Bellfi res has an obligation under the terms of this warranty (at its discretion) not to charge for the replacement of any component parts.
Note: The following aspects are not covered under the terms of the warranty:
- defects arising which are attributable in whole or in part to: a Not paying due heed to installation, operating and maintenance instructions b Fitting/installation or repair by third parties (including the buyer) c Heat cracks arising in the jacket due to normal heating d Discolouration in the ironwork as a result of heat transfer
- the grate, the thermocouple and the glass of the product
Should you wish to claim under the warranty,
please contact your dealer.
Please carefully retain your invoice with this warranty!
Your Bellfi res dealer: Date of installation:
Bellfi res
Hallenstraat 17
NL-5531 AB Bladel
Tel. + 31 497 339200 Fax. + 31 497 339210
1. WARRANTY TERMS
8
Bellfi res
English
Instructions for use and installation instructions
9
Bellfi res
English
Instructions for use and installation instructions
2 INSTRUCTIONS FOR USE
2.1 INTRODUCTION
Congratulations on your purchase of this modern Bellfi res gas fi re. This quality product will provide you with many years of enjoyment due to the fl ame effect and warmth that it provides. Please read the instructions for use carefully before using the appliance for the fi rst time. Keep this booklet in a safe place.
2.2 BUILT-IN PROTECTION OF THE APPLIANCE
The appliance is fully protected by means of a thermo-electric pilot light shut off in the event of a gas escape from the main burner.
2.2.1 Safety
Do not place embers, vermiculite granules, wood logs or pebbles against the pilot light burner. Make sure that the pilot fl ame can burn at all times freely over the main burner. Only in this way is proper ignition of the main burner ensured. Ignoring these directions could lead to a dangerous situation.
It is essential that the appliance, the complete concentric fl ue system and the outlet are cleaned and inspected annually by a recognised fi tter/gas specialist. The safe operation of the appliance will thus remain guaranteed. See for additional instructions Chapter 4: Maintenance.
If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
The gas fi re must never be used with the door open or the door glass removed.
Never place fl ammable material on the ceramic log set.
The fi lling of the main burner with embers, vermiculite granules, wood logs and pebbles may not under any circumstances be changed or added to.
Do not place easily-fl ammable materials, such as nylon clothing or fl ammable liquids, in the vicinity of the gas fi re.
10
Bellfi res
English
Instructions for use and installation instructions
“OFF” POSITION
IGNITION POSITION
CONTROL KNOB
BURNER CONTROL RANGE
Ensure at all times that children and other people who are not aware of the operation of the gas appliance are only in the vicinity of the appliance exclusively under supervision.
Use a fi reguard to protect the people and children mentioned above against possible burns.
2.3 OPERATING YOUR GAS FIRE - GENERAL
Read these instructions carefully before lighting the fi re!
The gas fi re can be operated with a pilot light that burns continuously. The ignition and control knob is located at the bottom of the front of your gas fi re or outside the gas fi re in a special box (supplied). If the control knob is fi tted to the front of the gas fi re, the gas fi re frame must be removed to access the knob.
The pilot light is situated in the front of the burner, behind a cowl. Should the pilot light
go out, you must wait fi ve (5) minutes before attempting to re-ignite the fi re.
Important
Once the fi re is lit, it must burn at maximum for approx. 10 minutes to allow the chimney to come up to temperature.
2.4 HAND CONTROL
The burner is operated using the control knob. Select the required setting and the burner will then burn at this setting until it is changed.
Figure 1: Gas regulator block BM 733
11
Bellfi res
English
Instructions for use and installation instructions
2.4.1 Igniting the fi re
• Open the gas supply valve in the gas pipe to the appliance.
• Press in the control knob and turn it (clockwise) as far as possible. It is now in the “off” position.
• Press the control knob and turn it anti-clockwise to the “PILOT” ignition position. You will hear a click, which is the spark for the pilot light. You may have to “click” several times before the pilot light ignites.
• Once the pilot light is ignited, hold in the knob for another ten (10) seconds and then release it.
If the pilot fl ame goes out, then wait for at
least 5 minutes before repeating the above procedure.
• The burner is ignited by turning the knob anti-clockwise to the desired setting.
I
mportant: • When the main burner is switched on by turning
the motor knob to the left, the burner must
ignite within 10 seconds. If this does not happen, immediately close the gas tap and warn the fi tter.
• If the main burner ignites with a pop; immediately close the gas tap and warn the fi tter.
2.4.2 Turning off the fi re
Press the knob and turn it to “PILOT”. The burner will continue to burn for a few seconds before being extinguished.
2.4.3 Extinguishing the pilot light
You can extinguish the pilot light by pressing the control knob when it is in the “PILOT” position and turning it clockwise to the “OFF” position.
If the gas fi re is not going to be used for a long period of time, it is recommended to close the gas supply valve to the fi re.
If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
If the pilot light frequently goes out, then please contact your installer.
12
Bellfi res
English
Instructions for use and installation instructions
2.5 REMOTE CONTROL
2.5 REMOTE CONTROL
2.5.1 General
The appliance is opperated by radio remote control. This comprises a hand-held transmitter and a receiver. The receiver is part of the gas control block assembly.
The receiver and the gas control block are behind the (white) panel door (operating unit) next to the appliance. Press the door inwards to open; this will release the catch and the door will spring out. or:
The receiver and the gas control block are behind the operating fl ap at the bottom of the appliance. Pull the fl ap forward to open.
The hand-held transmitter and receiver are powered by batteries. Hand-held transmitter : 1x 9V battery. Receiver : 4x 1.5V battery type LR6 or AA. Option: 6V adapter (230 VAC). Available from your fi tter.
Note: Hand-held transmitter and receiver are not interchangeable with previous models.
2.5.2 Hand-held transmitter
The remote control works by radio signal. The hand-held transmitter is confi gured in the factory with a unique signal code.
13
Bellfi res
English
Instructions for use and installation instructions
Figure 2: Hand-held transmitter
Set the display
• Connect the batteries. By simultaneously pressing OFF and (small fl ame), can be switched from °F (and 12 hour clock) to °C (and 24 hour clock), or vice versa.
• The display will automatically return to mode after some time, but you may immediately return to mode by pressing the OFF button.
Set the current time
• By simultaneously pressing (large fl ame) and (small fl ame), the display fl ashes.
You are in SET mode.
• While the screen is fl ashing, you can adjust the time.
• Press (large fl ame) to set the hour and (small fl ame) to set the minute.
• Wait or press OFF to return to mode.
Important: Setting up signal code before using the appliance for the fi rst time.
Before the appliance can be used, the receiver must fi rst learn the hand-held transmitter’s signal code.
• Press the “RESET” button on the receiver, and keep this pressed until 2 audio signals are heard. See fi gure 3. Release the “RESETbutton after the second (somewhat longer) audio signal.
• Press, within 20 seconds, the (small fl ame) button on the hand-held transmitter, until a somewhat longer signal is heard. The signal code has now been set up on the receiver.
You only need to set up the signal code once. It is not necessary when changing the batteries of the hand-held transmitter or receiver.
14
Bellfi res
English
Instructions for use and installation instructions
Figure 3:
Receiver “RESET” button
Operating possibilities
It is possible to use the remote control in 3 ways to operate the appliance:
1 :
2 : and
3 :
You can cycle through the menu with operating possibilities by repeatedly depressing the SET button.
At the selected starting time (P1 or P2 ) or stopping time (P1 or P2
) is
also shown.
Returning to is also possible by pressing the (small fl ame) or
(large fl ame)
button.
15
Bellfi res
English
Instructions for use and installation instructions
Manual operation
Here you can turn the burner on and off, and adjust the height of the fl ames.
• Press (large fl ame) to turn on the burner and to increase the fl ame height.
• Press
(small fl ame) decrease the fl ame height to turn the burner off.
The pilot light will keep burning. (Stand-by position)
• The appliance will automatically revert to stand-by if the hand-held transmitter is not operated for more than 6 hours.
• When one of the
buttons on the hand-held transmitter is pressed (except
the SET button), the transmission symbol
appears on the screen.
The receiver confi rms the transmission with an audio signal.
Operating day temperature thermostat
(Appliance is in the stand-by position and the pilot light is burning.)
Automatic temperature regulation of the pre-set day temperature. The room temperature is measured and compared with the pre-set day temperature. The fl ame height is automatically regulated so as to reach the pre-set day temperature. Also see: Setting the desired temperature.
Operating the night temperature thermostat
(Appliance is in the stand-by position and the pilot light is burning.) Automatic temperature regulation of the pre-set night temperature. The room temperature is measured and compared with the pre-set night temperature. The fl ame height is automatically regulated so as to reach the pre-set night temperature. Also see: Setting the desired temperature.
Timer operation
(Appliance is in the stand-by position and the pilot light is burning.)
Appliance functions automatically according to the two pre-set heating periods;
P1 and P2. These heating periods repeat automatically every 24 hours. Also see: Programming the timer: P1 and P2.
The appliance works thermostatically at the pre-set starting times P1 and P2 and the room temperature is automatically regulated to the pre-set day temperature .
The appliance works thermostatically at the pre-set stopping times P1
and
P2
and the room temperature is automatically regulated to the pre-set night temperature . In order to allow the appliance to regulate the temperature at night, the night temperature must be set to at least 5°C.
If the setting is lowered to , the appliance will switch to stand-by at night. The appliance will automatically operate at the following day cycle .
N.B.: The pre-set temperature is shown on the screen every 30 seconds.
16
Bellfi res
English
Instructions for use and installation instructions
Setting the desired temperature
• Select the desired mode of operation or
by pressing the SET button
briefl y.
• Hold the SET button until the display fl ashes.
• Set the temperature with (large fl ame) or (small fl ame).
• Wait or press the OFF button briefl y to go to mode.
• If the temperature control in should be off (lower battery consumption), decrease the night temperature until appears on the display.
Important: Place the hand-held transmitter in a place that is not
infl uenced by direct sunlight, draught, heat from the appliance and other heat sources.
Programming the timer: P1 and P2
• Select the desired mode of operation
by pressing the SET button briefl y.
• Press the SET button until P1 (heating period 1) and the time fl ashes.
• Set the time for the beginning of the fi rst heating period by pressing (large fl ame) for houre and (small fl ame) for minute’setting.
• Press the SET button briefl y; P1
appears on the display. Set the time for the end
of the fi rst heating period.
• Press SET again to set the second heating period P2
(heat ON) and P2
(heat
OFF).
• Wait a moment or press OFF to switch back to
mode.
2.5.3 Operation (Remote Control)
Igniting the fi re
• Open the gas supply valve in the gas pipe to the fi re.
• Press the “O I” switch on the gas control block to the “I” position.
• Turn the operating knob on the gas control block to the ON position.
• Switch the hand-held transmitter to the
position.
• On the hand-held transmitter, press the «- OFF and (large fl ame) buttons simultaneously. A short tone will signal the start. Short beeps will then follow until the pilot light and main burner are ignited. Once the main burner has been ignited, the fl ame height will automatically rise to the maximum position.
Important: If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
If the pilot light does not ignite after 3 ignition attempts; close the gas tap and warn the fi tter.
Once the pilot light is burning, the main burner must ignite within 10 seconds automatically. If this does not happen, immediately close the gas tap and warn the fi tter.
If the main burner ignites with a pop; immediately close the gas tap and warn the fi tter.
17
Bellfi res
English
Instructions for use and installation instructions
Figure 4: Gas regulating block; Operating Knob in ON-position
Motor-Knob (in maximum position)
Microswitch
Operating Knob
Connection Piezo Igniter (only for MANual control)
ON/OFF Switch
8-wire
Receiver Jack
• Possible error messages: * 3x short audio signal, audible when the motor-knob operates: Receiver batteries need changing soon (having heard this signal, the appliance can be ignited another ten times approximately). * 5 second unbroken tone: Error. For example, one of the cables may not be properly connected, the “O I” switch is not in the “I” position. * 5 short beeps: Ignition of the pilot light and main burner failed. Possible cause: air in the pilot light pipe.
Important: If the pilot fl ame goes out, then wait for at least 5 minutes before repeating the above procedure.
Setting the fl ame height / extinguishing the fi re
• After ignition, the burner automatically sets the fl ames to the maximum height
.
• Press button (small fl ame) to lower the fl ames and to turn off the main burner
(Extinguishing the fi re: small fl ame button: pilot light remains burning!)
(Pressing briefl y the (small fl ame) button gradually lowers the fl ames to the low
position.)
• Press button (large fl ame) to increase the fl ame level and to turn on the burner. (Pressing briefl y the (large fl ame) button gradually increases the fl ames to the high position.)
18
Bellfi res
English
Instructions for use and installation instructions
Important: If you turn on the main burner by pressing the (large fl ame) button, it must ignite within 10 seconds. If this does not happen, immediately close the gas tap and warn the fi tter.
If the main burner ignites with a pop; immediately close the gas tap and warn the fi tter.
Switching off the appliance
• Press the
(small fl ame) button to lower the fl ames or to switch off the main burner.
• Then press the «-OFF button to switch off the appliance, including the pilot light.
• Press the “O I” switch (on the gas control block) to the “O” position. This conserves
battery life.
• If the appliance is not to be used for some time, please close the gas supply valve in the gas pipe.
Important: If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
Faults
• If the signals from the hand-held transmitter do not seem to be reaching the receiver, the cause may be:
* Spent batteries: replace the batteries. * An electronic problem: press the “RESET” button on the receiver.
• If the appliance regularly switches itself off, please contact your installer.
Replacing the batteries
• The hand-held transmitter/receiver batteries have a service life of approx. one year.
We recommend you use alkaline batteries.
• The batteries must be replaced whenever:
1 Hand-held transmitter: BATT appears in the display screen. 2 Receiver: 3x short audio signal, audible when the motor-knob
operates.
1 Hand-held transmitter:
* Open the cover on the back of the transmitter. * Carefully remove the 9V battery and disconnect it from the contact.
Do not pull the wires! * Connect the new battery and replace in the battery compartment. Close the cover.
19
Bellfi res
English
Instructions for use and installation instructions
2 Receiver: * Carefully pull the receiver assembly out of the compartment behind the (white) panel door.
* Open the cover. * Remove the batteries from the battery compartment. * Place four new 1.5V batteries (LR6 or AA type) as indicated in the battery
compartment. The negative end (-) of the battery must always be at the contact spring end of the compartment.
* Close the cover and place the receiver back in its holder.
• If the batteries are inserted incorrectly, the electronics or drive may be irreparably
damaged.
• Only replace the batteries when the appliance has been completely switched off.
Figure 5: Gas regulating block; Operating Knob in MAN-position
2.5.4 Operation (Hand control)
In an emergency it is possible to operate the appliance manually. To do so, the ignition
(piezo) cable must fi rst be removed and transferred carefully to the piezo connector on the gas control block.
Motor-Knob (in maximum position)
Microswitch
Operating Knob (in Position for Manual Ignition)
Metallic Core for Manual Ignition (recessed switch)
Connection Piezo Igniter (only for MANual control)
ON/OFF Switch
8 Wire
Receiver Jack
Piezo button (only for MANual control)
20
Bellfi res
English
Instructions for use and installation instructions
Igniting the fi re
• Open the gas supply valve in the gas pipe to the fi re.
• Switch the “O I” switch on the gas regulating block to the “I” position.
• Turn the motor-knob on the gas regulating block as far as it will go in a clockwise direction. The switch will audibly ‘click’.
• Turn the operating knob on the gas control block to the MAN position. A recessed switch within the knob will become visible.
• Press the recessed switch. Use a pen or similar instrument to do this.
Gas will now fl ow to the pilot light.
• While holding down the recessed switch, press the (square) piezo button several times (the piezo button is alongside the “O I” switch) to ignite the pilot light.
Check whether the pilot light has been lit through the glass.
l Once the pilot light is lit, the recessed switch must be kept down for a further ten
seconds, after which it can be released.
Important: If the pilot fl ame goes out, then wait for at least 5 minutes before repeating the above procedure.
• Move the operating knob to the ON position. Depending on the position of the motor­knob, the burner will either ignite or not.
• By turning the motor-knob anti-clockwise to the desired position, the burner will ignite and the fl ame height can be controlled.
Important: • When the main burner is switched on by turning the motor knob to the left, the burner must
ignite within 10 seconds. If this does not happen, immediately close the gas tap and warn the fi tter.
• If the main burner ignites with a pop; immediately close the gas tap and warn the fi tter.
Extinguishing the fi re
• Turn the motor-knob on the gas regulating block as far as it will go in a clockwise
direction. The knob will audibly ‘click’. The burner is now switched off. The pilot light will remain lit.
Switching off the appliance
• Press the “O I” switch on the gas regulating block to the “O” position. The pilot light will be extinguished.
• If the gas fi re is not going to be used for a long period of time, it is recommended to close the gas supply valve to the fi re.
Important: If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
21
Bellfi res
English
Instructions for use and installation instructions
2.6 USING THE APPLIANCE FOR THE FIRST TIME
The gas fi re is coated with a lacquer layer resistant to high temperature. During the fi rst hours of operation, the burning in of the lacquer may result in an unpleasant smell. This is harmless, however. Operating the gas fi re at full capacity for a few hours, while ventilating the room, will eliminate the smell. After using your gas fi re for the fi rst few times, you may be aware of a light deposit on the inside off the glass. This is caused by the paint curing. Once your fi replace has cooled down, this deposit can be removed with glass cleaner or ceramic hob cleaner.
2.7 DAILY MAINTENANCE
• Ensure that as little dust, and as few particles of cigarette smoke, candles and oil lamps as possible pollute the air in the room in which the appliance is used. Heating of these particles by the convection system of the appliance could lead to discoloration of the walls and ceiling. It is therefore very important to ensure that the room in which the appliance is located is suffi ciently ventilated. Regularly remove
any dust deposits from behind the control fl ap by means of a vacuum cleaner.
Important: If the glass is broken or cracked, it must be immediately replaced before operating the gas fi re again.
If the appliance has two or more windows, regularly check whether the glass panes fi t fi rmly together. Gaps between the glass panes can lead to the leakage of fl ue gasses into the living room!
• If anything is spilt on the fi re, switch it off immediately and wait for it to cool down suffi ciently before cleaning. Never use scouring powder, aggressive cleaners or fi re polish on the gas fi re. Use only a dry lint free cloth.
• Heat resistant lacquer in aerosols can be obtained from your distributor. During the yearly maintenance, the lacquer can be used to repair small areas of damage.
The installation must only be carried out by a
“Gas Safe Register” registered installation engineer.
IMPORTANT
22
Bellfi res
English
Instructions for use and installation instructions
3 INSTALLATION INSTRUCTIONS
3.1 GENERAL
The gas fi re must be positioned and connected as a “room sealed system” (balance
fl ue) appliance by a “Gas Safe Register” registered gas installation engineer in accordance with the following installation instructions, nationally and locally applicable regulations (see “Technical Details/ Regulations” at the rear of this manual). If you have any queries regarding the installation, please consult your local gas company.
Important: Before beginning the installation, check that the details on the rating plate correspond to the gas type and pressure to which the appliance will be connected.
The appliance is factory set to the correct nominal heat input. The pilot light is set to the correct level of consumption.
It is possible to install the gas fi re with either a wall or roof outlet, using the Barbas or Ontop (US-System) concentric fl ue Ø100 mm (inner) - Ø150 mm (outer) system. Exception: the View Bell Vertical is only suitable for the Barbas mark. The fumes are exhausted naturally to the outside environment through the inner Ø100 mm pipe whereas the combustion air supply passes between the Ø100 mm and Ø150 mm pipes.
The gas fi re can be installed in a completely sealed or mechanically ventilated house without extra ventilation and/or fume extraction.
The gas fi re can be installed as an insertion into an existing open fi re place or as a built-in appliance in a new fi re place.
In order to prevent the fi replace heating up excessively, it must be properly ventilated by installing vents at the top and bottom of the fi replace.
The appliance can be fi tted with a convection package as an optional extra. This is a “convection jacket” around (or above) the appliance, two fl exible aluminium pipes and two built-in convection vents. This enables hot air to be circulated into the room.
When handling the frame, we advise you to use the special gloves supplied, and to leave them with the owner of the hearth after installation.
If an existing chimney is to be used, please consult your installer fi rst. If the chimney was previously used for a wood or coal fi re, then it should be cleaned by an expert.
23
Bellfi res
English
Instructions for use and installation instructions
3.2 BARBAS AND ONTOP CONCENTRIC FLUE
Ø100 MM - Ø150 MM SYSTEM
The appliance is in combination with the concentric fl ue system [Ø100 mm – Ø150 mm] (either rigid or fl exible) of Barbas or Ontop (US system) compliant with the European CE norm for gas appliances, and may therefore only be used with these systems. Exception: the View Bell Vertical is only suitable for the Barbas mark. The guarantee is invalidated if the appliance is (completely or partially) installed using a different system. The Barbas and Ontop concentric fl ue [Ø100 mm - Ø150 mm] systems can be used with either a newly-built or existing chimney.
3.3 PREPARATION FOR INSTALLATION
The following preparation must be carried out before the gas fi re can be installed.
3.3.1 Instructions for positioning the outlet
3.3.1.1 Positioning the outlet for correct operation:
Roof-mounted outlet:
Figure 6: Roof-mounted outlet
This must be positioned at least 0.5 m from the roof edge; the apex of the roof can be disregarded.
>0.5 m
24
Bellfi res
English
Instructions for use and installation instructions
Wall-mounted outlet:
Figure 7: Wall-mounted outlet
This must be positioned at least 0.5 m from:
• the corner of the building
• the roof overhang, the rain gutter
• balconies etc., unless the exhaust construction extends to at least the face of the protruding section.
>0.5 m
25
Bellfi res
English
Instructions for use and installation instructions
3.3.1.2. Positioning the outlet to avoid affecting the surrounding area
All listed “distances” in this section are no more than guidelines. For the exact minimum “distances”, please consult your national and local directives.
Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to:
A. A ventilation opening serving an occupied room, a toilet or a bathroom.
B. A heating air supply, when the supply fl ows through an occupied room.
C. A window that can be opened and that is near an occupied room, a toilet or a bathroom.
Roof-mounted outlet:
To avoid adverse effects Distance: outlet - A, B or C
At the same roof level. >3 m (*)
At a different roof level. >1 m (*)
At a lower positioned wall. >1 m
At a higher sloping surface. >3 m (**)
(*) If the required distance cannot be achieved, the outlet position rules take precedence.
(**) If the required distance cannot be achieved, the position of the outlet must be at least 1 m above the highest facade/roof.
26
Bellfi res
English
Instructions for use and installation instructions
Wall-mounted outlet:
To avoid adverse effects Distance: outlet - A, B or C
At walls in buildings with staggered Not permitted if A, B, or C are located heights. above the outlet.
On a wall - general. (*) Above the outlet: >2 m Below the outlet: >0.75 m Left and right of the outlet: >0.75 m
At <1 m from the roof overhang. >2 m
Beneath balconies, walkways etc. >2 m tot onderzijde van een uitstekend balkon of galerij.
Beneath balconies, walkways >2 m etc. where the outlet extends to the front.
To the garden or on the terrace. >2 m to the outside space. (**)
With respect to a facing wall. >2 m (if the distance from the facing wall is less, the criteria detailed for “On a wall - general” apply.
Enquire at your local gas company for the regulations relating to outlets positioned opposite each other and outlet(s) in facade(s) that form an angle.
(*) These minimum distances do not apply if there is an obstruction between the outlet and A, B and C that protrudes at least 0.5 m from the wall and has a length exceeding the distance.
(**) This distance is not required if the outlet is situated at least 1 m higher than the intended area of the outside space.
If the outlet has a clearance of less than 0.5 m from the hard surface of a public area at
a height of less than 2 m, it must be fi tted with an effective protector. The mesh size of the guard must not affect the correct operation of the appliance.
27
Bellfi res
English
Instructions for use and installation instructions
3.4 GENERAL SERVICES
3.4.1 The Fume Channel/Combustion Air Intake
The combined fume channel and combustion air intake requires one of the following
Barbas or Ontop concentric fl ue system confi gurations. Exception: the View Bell Vertical is only suitable for the Barbas mark.
Important: Due to the high temperature of the outer walls
(approx. 150°C), no fl ammable materials may be located or used in the vicinity of the fl ue system. The complete fl ue system, must therefore be sleeved with a heat resistant material after assembly.
Ventilate the covered concentric fl ue by fi tting a grid near the fl oor and ceiling (on each fl oor).
Do not insulate the concentric fl ue.
Use the universal wall/fl oor support Ø150 mm to attach the covering of the concentric fl ue system [Ø100 mm - Ø150 mm], see 3.4.2, drawing number 36.
Figure 8: Application universal wall/fl oor support Ø150 mm
36
36
Use as a wall support Use as a fl oor support
28
Bellfi res
English
Instructions for use and installation instructions
Figure 9: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Appliance: Distance X Distance Y Assemble (min.-max.) (min.-max.) restriction plate
All appliances, 0 - 0.6 m 0.5 - 1.0 m -
except...
0 - 3.0 m 1.0 - 3.0 m -
... Derby Derby II
0 - 0.6 m
1.0 - 2.0 m
-
Jersey
0 - 3.6 m 2.0 - 3.0 m -
Horizon Bell Medium
... Horizon Bell Small (Tunnel) 0 - 3.0 m 1.5 - 3.0 m -
... Vertical Bell Small
0 - 0.6 m 0.5 - 1.0 m -
0 - 3.0 m 1.0 - 3.0 m -
... Vertical Bell Large Tunnel
0 - 1.6 m 0.0 - 1.0 m -
0 - 3.0 m 1.0 - 3.0 m -
... View Bell Vertical
0 - 0.6 m 0.5 - 1.0 m Width: B = 30 mm
0 - 3.0 m 1.0 - 3.0 m -
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
19
1
4
23
10, 11, 12, 13
23
X
Y
28
0.16 m
Wall Termination Position
Item descriptions:
see 3.4.2
29
Bellfi res
English
Instructions for use and installation instructions
Figure 10: Vertical roof-mounted outlet without bend
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Appliance:
Distance Y Assemble
(min.-max.) restriction plate
All appliances, except... 2.0 - 12.0 m -
... Jersey ... Vertical Bell Small
2.0 - 12.0 m
Width: B = 30 mm ... Vertical Bell Large Tunnel ... Horizon Bell Medium
... View Bell Vertical
2.0 -
6.0 m Width: B = 50 mm
6.0 - 12.0 m Width: B = 65 mm
18
10, 11, 12, 13
1
4
Y
28
16
17
16
24
23
24
23
Item descriptions:
see 3.4.2
30
Bellfi res
English
Instructions for use and installation instructions
Figure 11: Vertical roof-mounted outlet with bend
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Appliance: Distance Y1 (*) Distance X (*) Distance Y1 + Y2 (*) Assemble (min.-max.) (min.-max.) (min.-max.) restriction plate
All appliances, except... 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m -
... View Bell Vertical 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Width
: B = 30
mm
16
23
Y
2
X
10, 11, 12, 13
14, 15
Y
1
4
1
28
23
23
17
24
Item descriptions:
see 3.4.2
(*) : (Y1 + Y2) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
31
Bellfi res
English
Instructions for use and installation instructions
1
4
28
32
18
23
25
26
29
7
5
29
30
10, 11, 12, 13
Y
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Appliance:
Distance Y Assemble
(min.-max.) restriction plate
All appliances, except... 2.0 - 12.0 m -
... Jersey ... Vertical Bell Small
2.0 - 12.0 m
Width: B = 30 mm ... Vertical Bell Large Tunnel ... Horizon Bell Medium
... View Bell Vertical
2.0 - 6.0 m
Width
: B = 50 mm
6.0 - 12.0 m
Width
: B = 65 mm
Item descriptions:
see 3.4.2
Figure 12: Vertical chimney outlet using an existing lined chimney (Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
32
Bellfi res
English
Instructions for use and installation instructions
Figure 13: Vertical chimney outlet using a lined chimney with a bend > 45° (Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
(*) : (Y1 + Y2+ Y3) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Y
2
Y
1
10, 11, 12, 13
> 45°
X
Y
3
32 18 30
29
5
7
29 26
25
23
28
4
1
Appliance: Distance Y1 (*) Distance X (*) Distance Y1 + Y2 + Y3 (*) Assemble (min.-max.) (min.-max.) (min.-max.) restriction plate
All appliances, except... 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m -
... View Bell Vertical 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Width
: B = 30
mm
Item descriptions:
see 3.4.2
33
Bellfi res
English
Instructions for use and installation instructions
Y
7
6
8
18
32
31
29
30
29
26
29
27
28 29
4
1
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Appliance: Distance Y Assemble (min.-max.) restriction plate
All appliances, except... 2.0 - 12.0 m -
... Jersey ... Vertical Bell Small
2.0 - 12.0 m
Width: B = 30 mm ... Vertical Bell Large Tunnel ... Horizon Bell Medium
... View Bell Vertical
2.0 - 6.0 m Width: B = 50 mm
6.0 - 12.0 m Width: B = 65 mm
Item descriptions:
see 3.4.2
Figure 14: Vertical chimney outlet using an existing unsound lined chimney or when no chimney liners are present (Flexible Ø100 mm / Ø150 mm)
34
Bellfi res
English
Instructions for use and installation instructions
Figure 15: Vertical chimney outlet using an existing unsound lined chimney or when the chimney is unlined; with a bend >45° (Flexible Ø100 mm / Ø150 mm)
(*) : (Y1 + Y2+ Y3) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
Y
3
Y
2
Y
1
X
> 45°
6
8
7
31 29
32 18
30
29
26
29
27
28 29
4
1
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Appliance: Distance Y1 (*) Distance X (*) Distance Y1 + Y2 + Y3 (*) Assemble (min.-max.) (min.-max.) (min.-max.) restriction plate
All appliances, except... 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m -
... View Bell Vertical 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Width
: B = 30
mm
Item descriptions:
see 3.4.2
35
Bellfi res
English
Instructions for use and installation instructions
FIG. NO. DESCRIPTION
1 Gas fi re
2 -
3 -
4
Restriction plate
(if applicable)
5 Chimney, min. Ø150 mm internal, totally gas tight
6 Chimney or fi reproof sleeving. Min. Ø160 mm internal
7 Ø100 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI
8 Ø150 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI
9 -
FIG.
NO.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
DESCRIPTION
Twin-wall balanced fl ue pipe, L = 500 mm, incl. and
Twin-wall balanced fl ue pipe, L = 1000 mm, incl.
and
Telescopic twin-wall balanced fl ue pipe, L = min. 325 mm / max. 440 mm, incl. and
Adjustable length twin-wall balanced fl ue pipe, L = 500 mm, incl. and
Twin-wall balanced fl ue elbow
90º, incl. and
Twin-wall balanced fl ue elbow
45º, incl. and
Vertical (roof) termination kit, L = 1360 mm (vertical), incl. , and
Adjustable roof fl ashing. Roof pitch 20º - 45º (**), with lead fl ashing
Roof fl ashing for existing chimney or fl at roof.
Horizontal (wall) termination kit, L = 600 mm (horizontally adjustable)), incl. , and one set of wall spacer plates
:
Stainless steel locking band Ø150 mm, quick-fastening
: Silicone seal Ø150 mm
: Wall strap
Set of ceiling fi nishing plates / fi re stops
ART. /
ORDER
NO.
302289
302290
302291
302292
302297
302298
302295
302212
302213
302296
302293
302210
302215
302214
Color(*) Application
RVS antr. RIGID FLEX
l
l
l
l
l
l
l
l
l
l
l
l
l
AVAILABLE COMPONENTS FOR THE BARBAS CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm
3.4.2 Item descriptions for fi gures 9 t/m 15.
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
36
Bellfi res
English
Instructions for use and installation instructions
The room-sealed gas appliances have been approved in combination with the BARBAS or ONTOP (RIGID and FLEXIBLE) CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm according to the European CE norm for gas appliances
and may therefore be used only in combination with this fl ue system. Exception: the View Bell Vertical is only suitable for the Barbas mark.
FIG.
NO.
25
26
27
28
29
30
31
32
33
34
35
36
DESCRIPTION
Ceiling plate for transition Ø100 mm / Ø150 mm rigid ­Ø100 mm (fl ex.).
Stainless steel adapter piece (100) from fi re to fl exible, Ø100 mm external (rigid) x Ø107 mm internal (fl ex.). [appliance -
Ø100 mm fl ex.] and [Ø100 mm rigid - Ø100 mm fl ex.].
Stainless steel adapter piece (150) fi re to fl exible, Ø148 mm external (rigid) x Ø148 mm internal (fl ex.) [appliance - Ø150 mm fl ex.].
Stainless steel locking band Ø150 mm. For adapter 150 [appliance - Ø150 mm fl ex.] Screw-fastening
Stainless steel screws Ø3.5 mm x Ø9.5 mm. For securing the fl exible concentric fl ue. (Minimum 3 screws per connection)
Hose clamp Ø100 mm. (Minimum 2 per connection)
Hose clamp Ø150 mm. (Minimum 2 per connection)
Vertical (roof) termination kit, L = 610 mm (vertical), incl. and . For the fl exible fl ue system.
Concentric T-piece with gauging orifi ce, incl. and
Concentric pipe with gauging orifi ce, L=165 mm, incl. and
90º concentric bend with inspection panel incl. and
Universal wall / fl oor support Ø150 mm
ART. /
ORDER
NO.
302189
302278
302279
302217
303776
304041
304042
302307
302301
302302
302303
321948
Color(*) Application
RVS antr. RIGID FLEX
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
If the appliance has been ordered with the BARBAS concentric fl ue/chimney system, a concentric Bellfi res adapter will be supplied free of charge. (Not applicable for View Bell Vertical.)
(*) : Color: RVS: Stainless steel self-colour, polished antr.: Anthracite colour lacquer, matt (**) : Adjustable roof fl ashing for a slope > 45º can be supplied on request.
When installing a balanced-fl ue “closed” gas fi re in an existing chimney, ensure stain­less steel fl exible liners conforming with BS 316 are used to conduct the spent gases.
37
Bellfi res
English
Instructions for use and installation instructions
Min. 5 cm
Min. 5 cm
3.4.3 Gas connection
Operation (gas regulating block (and receiver))
within the appliance:
The gas connection Ø12 mm (3/8”) is located on the right-hand side of the appliance.
Operation (gas regulating block (and receiver)) outside the appliance (in the operating unit):
The gas connection is situated where the operating unit is built in near to the appliance.
Use only gas piping with a minimum diameter of 1/2” and a shut-off valve.
3.4.4 Operating unit
If the appliance is fi tted with a operating unit comprising gas control block and receiver, this will be located, once it has been built in, at a maximum of 50 cm from the left or right hand side of the appliance.
3.4.5 Convection package connections
When fi tting a convection package, consideration should be given to the openings at approximately 1 meter above the appliance for the warm air exiting grids. If a convection package is to be fi tted, the metal “insulation” shield at the top of the appliance, must also be removed.
3.5 POSITIONING THE APPLIANCE
Important: The fi re and fi replace must be mounted on a concrete fl oor. If there is no concrete fl oor, it is essential to re-enforce the fl oor boards from beneath with concrete.
Never place the appliance directly on the fl oor, but always make sure that there is a clearence of at least 5 cm between the appliance and the fl oor.
Figure 16: A clearence of at least 5 cm must be maintained between the appliance and the fl oor.
38
Bellfi res
English
Instructions for use and installation instructions
Never use combustible materials during the installation.
Ventilate the fi replace, by allowing vents above and below the fi replace.
During installation of the gas fi re, a clearance of 3 mm should be maintained on all sides of the appliance to allow for expansion of the appliance during operation.
Do not insulate the appliance! Only the top and sides may be fi tted with a strip of white, loose insulation wool (heat-resistant to 1000°C), width 15 cm max. to protect the wall.
Do not use fi breglass or Rockwool, or any other sort of insulating material. These emit a pungent odour. This is considered extremely unpleasant. They may also cause discolouring of the column.
Flammable materials, such as curtains, should not be placed in the vicinity of the gas fi re. Minimum safe distance: 100 cm
View Bell Vertical: If the appliance is hung, use the proper connecting method, suitable for the particular wall or partition.
The appliance may only be installed on a wall constructed from non-fl ammable material.
If desired, fi t a convection package to the appliance.
(See chapter 3.1)
39
Bellfi res
English
Instructions for use and installation instructions
When fi tting the appliance, it can be levelled with the adjustable feet.
Position the gas supply pipe such that it can be easily mounted after installation. If the appliance has a operating unit, the gas pipe must lead to where the operating unit (built in), the gas regulating block (and the receiver) assembly are fi tted.
Push the appliance against the wall and ensure that it is level. The appliance must not
make contact with a fl ammable rear wall.
Attach the appliance to the wall with 2 wedge bolts. Use the adjustable mounting brackets at the top of the appliance for this.
View Bell Vertical: If the appliance is hung on the wall, attach it with 4 Ø8 mm or Ø10 mm key bolts. Ensure that the appliance is hanging level and that the concentric exhaust vent/combustion air supply connection of the appliance is in perfect alignment with the hole in the ceiling or wall!
Figure 17: Use of convection package and ventilation of fi replace
40
Bellfi res
English
Instructions for use and installation instructions
Figure 18: Operating unit
Connect the supplied Ø8 mm copper gas pipe to the underside of the burner plate on
the fi re using the compression coupling.
ATTENTION !!!
BLOW THE INSIDE OF THE COPPER PIPE WELL CLEAN AFTER BENDINGN
The connections for the main burner (Ø8 mm copper), pilot light (Ø4 mm copper or aluminium), thermocouple (thermocouple interrupter) and piezo cable can now be made at the gas regula
ting block in the operating unit. If the system has remote control, the piezo cable, the 8-terminal cable and the two thermocouple cables must be connected to the receiver (see fi gure 19 and Chapter 6: Electrical Diagram).
Important: Using the hand, screw the thermocouple connection (and thermocouple interrupter) into the back of the gas regulating unit. Carefully tighten another half of a turn using a number 9 fork spanner. See fi gure 19, 20 and Chapter 6.
3.5.1 Connecting the gas
Important: During gas connection, take care not to twist the gas regulating block. Make sure that both the gas regulating block and the supply pipes are not subjected to stresses.
Appliance with operation in the separate operating unit (built in or otherwise):
• The control unit and piping are supplied separately (fl at packed)
Remove the decorative edging and door of the operating unit. Fit the separate operating unit with the gas control block and receiver max. 50 cm from the appliance.
Operating unit
Frame with door (white)
41
Bellfi res
English
Instructions for use and installation instructions
Remote control Gas regulating block and receiver in operating unit
Figure 19: Remote control: Gas regulating block and receiver in operating unit
1 Gas regulating block 2 Gas supply connection 3/8” - Ø12 / Ø15 mm insertion 3 Burner piping connection Ø8 mm insertion 4 Thermocouple connection M 10x1 mm insertion 5 Pilot light piping connection Ø4 mm insertion 6 Receiver 7 Piezo cable connection
42
Bellfi res
English
Instructions for use and installation instructions
Remote control
The photo below shows how the piping for a remote control gas regulating block must
be fi tted.
Figure 20: Gas regulating block Remote control
Side-inlet
Side-outlet
Bottom Outlet Bottom Inlet
Inlet Pressure Tap
Outlet Pressure Tap
Thermo Unit Connection
Minimum Rate Adjustment Screw
Motor-knob
Operating-Knob
Pilot Gas Adjustment (with Screwdriver)
(Tab 2,8 x 0,8 mm) Connection piezo cable (Hand Control)
Maximum Rate Adjustment Screw
43
Bellfi res
English
Instructions for use and installation instructions
Figure 21: Gas regulating block
Hand control Gas regulating block in operating unit.
The photo below shows how the piping for a hand control gas regulating block must be
fi tted.
Motor-Knob
Microswitch
Connection
Piezo Igniter
(Hand control)
Piezo Igniter
(Hand control)
O I” Switch
Connection
Pilot Gas
8-Wire Receiver Jack
Operating-Knob
(Remote control Hand control)
44
Bellfi res
English
Instructions for use and installation instructions
Appliance with operation in the separate operating unit (built in or otherwise).
• Gas control block and piping supplied as an pre-assembly.
First detach the bracket with the gas control block from the appliance. Fit the separate control unit max. 50 cm from the appliance. Fit the receiver in the top of the control unit.
Connect the piezo cable, the 8-terminal cable and the two thermocouple cables to the receiver (see Chapter 6: Electrical Diagram).
Carefully move the bracket with the gas regulating block and piping towards the control unit. Fit the bracket to the bottom of the control unit. Make sure that you do not damage any of the piping or detach any compression couplings while doing this. After you have done this, check the compression couplings for leaks.
General:
Route all piping and cables from the operating unit to the appliance through an easily accessible hollow cavity or a heat-resistant pipe of minimum Ø50 mm.
During subsequent installation of the operating unit, protect the gas regulating block and piping against encasement by cement etc.
Important: Cement and chalk can damage the piping and can, in turn, lead to gas leaks.
3.5.2 Connecting the concentric fl ue
Assemble the concentric fl ue system according to one of the examples in section 3.4.1, fi gure 9 to 15 inclusive. Make sure that all connections are completely gas tight.
3.5.3 Building in the appliance
Remove the front of the casing. Decide on positions of the vents (grilles above and below the fi replace) and, if applicable, the hot air grids of the convection package.
The brickwork must be built up around the hearth. In connection with the hearth expanding during burning: there must be at least 3 mm clearance on either side of the appliance. Do not build up the brickwork farther than the angle irons/brackets (keep in mind the thickness of any plastering!).
Connect up the convection package, if applicable.
45
Bellfi res
English
Instructions for use and installation instructions
The optional mantle iron is intended for supporting the brickwork above the hearth. The mantle iron must rest on the brickwork on both sides so that upward building is
possible. The brickwork therefore must not rest on the fi replace; there must be approx. 3 mm clearance in connection with the weight.
If using other materials, such as stone or heat-resistant plating, you should follow the supplier’s instructions.
Once the fi replace has been fi nished, you can now, for appliances with an operating unit, fi t the frame with the small door to the operating unit.
After installation in a new fi replace and/or applying new cement work, the appli­ance cannot be used for at least four weeks.
3.5.4 Checking the gas connection
After connection of the gas supply, check that all connections are completely gas tight using soapy water or a leak tester.
3.5.5 Positioning the ceramic log set or marble pebbles
The appliance can be supplied with:
• Ceramic log set + embers
• Marble pebbles white (small, white marble stones)
• Marble pebbles grey (small, grey marble stones)
Important: Carefully place the embers, set of logs or the marble pebbles on and around the main burner according to the directions in this chapter.
Do not place any embers, logs or marble pebbles against the pilot light burner. For that reason, the main burner has a protective pilot-light cowl. Never remove this cowl!
Make sure that the pilot fl ame can burn at all times freely over the main burner. Only in this way is proper ignition of the main burner ensured. Ignoring these directions could lead to a dangerous situation.
The burner bed (with embers) and the positioning of the logs or marble pebbles must not be changed.
Only use those items supplied! Thesebeen rigorously checked and the quantities adapted to the appliance.
Replacement parts, including the ceramic mat are available from your dealer.
Fitting may only be carried out by a qualifi ed person.
46
Bellfi res
English
Instructions for use and installation instructions
3.5.5.1 Ceramic log set + embers
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings. 2 Remove the embers (2x 100 gram) carefully from their packaging and spread them evenly over the burner mat and the grate around the burner. (
Exception: View Bell
Vertical: 1 x 125 gram embers.)
Note ! : • Small embers and their residue should not be scattered on
the burner. This can cause a blockage on the burner orifi ces.
• Embers must not be placed next to the pilot light burner.
• Ensure that the rear logs are approximately 3 cm from the rear
• If the burner runs on propane, make sure that all burner
openings remain free !!
The positioning of ceramic log set varies per model. Position the log set in one of the groupings shown below.
47
Bellfi res
English
Instructions for use and installation instructions
Group B:
Retro Bell Intermediate, Flat Bell
Group C:
Derby, Derby II, Horizon Bell Small
Group A:
York, Topsham (incl. Sandur), Kent
, Corne
r Bell Small, Vertical Bell Larg
e,
View Be
ll Small, (incl. Sandur Panorama), Retro Bell Small
Embers must not be placed next to the pilot light burner
Embers must not be placed next to the pilot light burner
Embers must not be placed next to the pilot light burner
48
Bellfi res
English
Instructions for use and installation instructions
Group E:
Horizon Bell Small Tunnel
• Position the logs as shown below.
Group D: Topsham Tunnel
Position the logs as shown below. The photos show the situation from either side.
Embers must not be placed next to the pilot light burner
Embers must not be placed next to the pilot light burner
49
Bellfi res
English
Instructions for use and installation instructions
Group F (a):
Jersey: Natural gas
Group F (b):
Jersey: Propane
Embers must not be placed next to the pilot light burner
Keep the burner
orifi ces unblocked
Embers must not be placed next to the pilot light burner
50
Bellfi res
English
Instructions for use and installation instructions
Group G (a):
Vertical Bell Small: Natural gas
Embers must not be placed next to the pilot light burner
51
Bellfi res
English
Instructions for use and installation instructions
Group G (b):
Vertical Bell Small: Propane
Embers must not be placed next to the pilot light burner
Keep the burner
orifi ces unblocked
52
Bellfi res
English
Instructions for use and installation instructions
Group H:
Vertical Bell Large Tunnel
Embers must not be placed next to the pilot light burner
53
Bellfi res
English
Instructions for use and installation instructions
Group I (a):
Horizon Bell Medium: Natural gas
Embers must not be placed next to the pilot light burner
54
Bellfi res
English
Instructions for use and installation instructions
Group I (b):
Horizon Bell Medium: Propane
Embers must not be placed next to the pilot light burner
Keep the burner
orifi ces unblocked
55
Bellfi res
English
Instructions for use and installation instructions
Groep J (a):
View Bell Vertical: Natural gas
Log no Log no
Log no Log no
Embers must not be placed next to the pilot light burner
56
Bellfi res
English
Instructions for use and installation instructions
Log no Log no
Log no Log no
Keep the burner orifi ces unblocked
Groep J (b):
View Bell Vertical: Propane
57
Bellfi res
English
Instructions for use and installation instructions
3.5.5.2 Marble pebbles
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Spread the pebbles over the whole burner bed (burner and grid around the burner).
Make sure that the pilot light remains free.
Figure 22: Marble pebbles-set NATURAL GAS
Figure 23: Marble pebbles-set PROPANE
IMPORTANT: Open area, in order to ensure free
accessibility of the pilot fl ame to the burner.
IMPORTANT: Open area, in order to ensure free
accessibility of the pilot fl ame to the burner.
Keep the burner orifi ces unblocked
58
Bellfi res
English
Instructions for use and installation instructions
Important: Do not place any marble pebbles in front of the pilot light. Make sure that the pilot light can burn freely over the main burner.
Keep the burner orifi ces unblocked.
Only this way a proper ignition of the main burner is ensured.
Once the logs/marble pebbles have been positioned, the door must be closed again or the glass must be replaced. FINGER-TIGHTEN any bolts and/or screws used. Do not over-tighten them as this may break the glass!
The frame can now be replaced. Note: Do not fi t the frame until the wall has been
fi nished. Use the protective items supplied (gloves or cloth). Do not use masking
tape!
3.5.6 Mounting fl ue gas restriction plate
Depending on the length and shape of the concentric fl ue system and the chimney
construction, you should, if indicated, fi t a restriction plate with a certain width (B), into the ceiling of the combustion chamber. To do this, see the set-up options as listed in fi gure 9 through 15.
Important: Ensure that the correct fl ue gas restriction plate is mounted. Use of the correct fl ue gas restriction plate will provide optimum effi ciency, fl ame effect and combustion. Mounting an incorrect fl ue gas restriction plate can result in damage to the gas fi re.
Figure 24: Positioning restriction plate
Assembly restriction plate
59
Bellfi res
English
Instructions for use and installation instructions
The following restriction plate is supplied:
Jersey :
Vertical Bell Small :
Vertical Bell Large Tunnel :
Restriction plate : Width: B = 30 mm
Horizon Bell Medium :
View Bell Vertical : Restriction plates : Width: B = 30 mm
Width: B = 50 mm
Width: B = 65 mm
3.5.7 Checking the appliance following installation
After installation, visually check the gas fl ame. When the fi re is ignited, the fl ames
should be short and blue/yellow in colour. These fl ames should gradually increase in
height and become more yellow. When all fl ames are yellow, the gas fi re has reached
the correct temperature.
THE GAS FIRE IS NOW READY FOR USE
60
Bellfi res
English
Instructions for use and installation instructions
4 MAINTENANCE
4.1 ANNUAL MAINTENANCE
It is essential that the appliance, the complete concentric
fl ue system and the outlet are cleaned and inspected annually by a recognised fi tter/gas specialist. The safe operation of the appliance will thus remain guaranteed.
Maintenance consists of the following:
• Remove fi rst the embers and/or vermiculite granules, set of logs and/or pebbles from
the main burner and carefully clean these with a soft brush.
• Clean and inspect (visually) the main burner, pilot light, combustion chamber,
fl ue system and combustion air intake. Dust can be removed using a vacuum
cleaner.
• After cleaning; Carefully replace the embers and/or vermiculite granules, set of logs and/or pebbles
on and around the main burner according to the installation directions in this
instruction booklet. Do not place any embers, vermiculite granules, logs or pebbles against the
pilot light burner. Make sure that the pilot fl ame can burn at all times freely over
the main burner. Only in this way is proper ignition of the main burner ensured. Ignoring these directions could lead to a dangerous situation.
• Check the gas supply, fl ue system, and combustion air supply route for leaks.
• Check the correct operation of the gas regulating block, thermocouple
circuit and the ignition of the main burner.
• Check the gas inlet-pressure (both when the appliance is off and when it burns
at maximum) and the burner pressure.
• Check the complete concentric fl ue system including the outlet construction.
61
Bellfi res
English
Instructions for use and installation instructions
5 FAULTS
Possible reasons for the gas fi re going out are:
• The concentric fl ue system is not installed according to one of the methods detailed in Paragraph 3.4
• An incorrect “fl ue gas restriction plate” is fi tted.
• The pilot light extinguishes if fumes are not exhausted or are insuffi ciently exhausted.
• The pilot light is either dirty or defective.
• Insuffi cient gas pressure.
• Thermocouple voltage is too low. This is usually caused by insuffi cient heating of the thermocouple by the pilot light.
• Dirty electrical contacts in the thermo-electrical system; for example, the thermocouple connection.
• Batteries in receiver or remote control are fl at.
62
Bellfi res
English
Instructions for use and installation instructions
6 ELECTRICAL DIAGRAM
6.1 MODELS WITH REMOTE CONTROL
Thermo­ couple
Ignition cable
Antenna
Button “Reset”
RECEIVER
panel
4 AA Batteries
cable 2
cable 1
“red”
SPARK
SPARK
SW TC
SW TC
GR
SW
MA
MO
Pilot
ON/OFF Switch
Thermocurrent interrupter Block
“red”
Motor­knob
Operating-Knob
O I” Switch
Gas regulating block
Battery
Compartment
“black”
“yellow”
Thermo ­current Interrupter Block
8 Wire connecting cable
63
Bellfi res
English
Instructions for use and installation instructions
7.1 DERBY / DERBY II (**)
7 DIMENSIONS
(*) Available with control unit in appliance (bottom) or in separate operating unit, see page 72 (**) Control unit in separate operating unit, see page 72 (***) Control unit in appliance (bottom)
7.2 JERSEY (**)
64
Bellfi res
English
Instructions for use and installation instructions
7.3 FLAT BELL (*)
7.4 TOPSHAM (*)
65
Bellfi res
English
Instructions for use and installation instructions
7.6 YORK (*)
7.5 TOPSHAM TUNNEL (*)
66
Bellfi res
English
Instructions for use and installation instructions
7.7 KENT (*)
7.8 RETRO BELL INTERMEDIATE (***)
67
Bellfi res
English
Instructions for use and installation instructions
7.9 RETRO BELL SMALL (***)
7.10 VIEW BELL SMALL (**)
68
Bellfi res
English
Instructions for use and installation instructions
7.11 CORNER BELL SMALL (**)
7.12 HORIZON BELL MEDIUM (**)
69
Bellfi res
English
Instructions for use and installation instructions
7.13 HORIZON BELL SMALL (**)
7.14 HORIZON BELL SMALL TUNNEL (**)
70
Bellfi res
English
Instructions for use and installation instructions
7.16 VERTICAL BELL LARGE TUNNEL (**)
7.15 VERTICAL BELL LARGE (**)
71
Bellfi res
English
Instructions for use and installation instructions
7.17 VERTICAL BELL SMALL (**)
7.18 VIEW BELL VERTICAL (**)
72
Bellfi res
English
Instructions for use and installation instructions
OPERATING UNIT
73
Bellfi res
English
Instructions for use and installation instructions
8 TECHNICAL DETAILS/REGULATIONS
National installation regulations:
Gas safety installation and use regulations 1984 plus all relevant
safety and building regulations concerning fi re installation
Model : DERBY
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3P Propane G31
Nominal heat input (Gross calorifi c value) : 12.5 kW : 9.5 kW Nominal heat output : 8.4 kW : 6.4 kW Effi ciency class : 2 (75%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 1.19 m
3
s
/hr. : 690 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Burner pressure (max.) Hot : 13.0 mbar(*) : 29.2 mbar
Burner pressure (max.) Cold : 11.9 mbar(**) : 29.2 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
626x140 mm Natural gas
: IGP
636x140 mm Propane Primary air inlet main burner : 1x Ø15.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 1200 : no 18 / 280 (= 7x Ø1.27 mm) (= 7x Ø0.62 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
74
Bellfi res
English
Instructions for use and installation instructions
Model : DERBY II
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3P Propane G31
Nominal heat input (Gross calorifi c value) : 11.5 kW : 9.5 kW Nominal heat output : 7.8 kW : 6.4 kW Effi ciency class : 2 (75%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 1.10 m
3
s
/hr. : 690 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Burner pressure (max.) Hot : 13.0 mbar(*) : 29.2 mbar
Burner pressure (max.) Cold : 11.9 mbar(**) : 29.2 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
626x140 mm Natural gas
: IGP
636x140 mm Propane Primary air inlet main burner : 1x Ø18.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 1200 : no 18 / 280 (= 7x Ø1.27 mm) (= 7x Ø0.62 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
75
Bellfi res
English
Instructions for use and installation instructions
Model : JERSEY
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3P Propane G31
Nominal heat input (Gross calorifi c value) : 9.5 kW : 6.8 kW Nominal heat output : 6.8 kW : 4.6 kW Effi ciency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.91 m
3
s
/hr. : 510 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Burner pressure (max.) Hot : 18.1 mbar(*) : 29.7 mbar
Burner pressure (max.) Cold : 17.1 mbar(**) : 29.7 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
443x140 mm Natural gas
: IGP
443x140 mm Propane Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 700 : no 18 / 220 (= 7x Ø0.99 mm) (= 7x Ø0.56 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
76
Bellfi res
English
Instructions for use and installation instructions
Model : YORK
TOPSHAM KENT VIEW BELL SMALL TOPSHAM TUNNEL SANDUR SANDUR PANORAMA
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3P Propane G31
Nominal heat input (Gross calorifi c value) : 8.3 kW : 8.5 kW Nominal heat output : 6.0 kW : 5.7 kW Effi ciency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.79 m
3
s
/hr. : 640 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Operation Burner pressure (max.) : 16.0 mbar (*) : 29.4 mbar in Hot appliance Burner pressure (max.) : 15.0 mbar (**) : 29.4 mbar Cold
Operation Burner pressure (max.) : 17.0 mbar (*) : 29.4 mbar in external Hot operating unit Burner pressure (max.) : 16.0 mbar (**) : 29.4 mbar Cold
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
443x140 mm Natural gas
: IGP
443x140 mm Propane Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 560 : no 18 / 260 (= 7x Ø0.90 mm) (= 7x Ø0.60 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
77
Bellfi res
English
Instructions for use and installation instructions
Model : FLAT BELL
RETRO BELL INTERMEDIATE
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3P Propane G31
Nominal heat input (Gross calorifi c value) : 10.0 kW : 9.5 kW Nominal heat output : 6.8 kW : 6.4 kW Effi ciency class : 2 (75%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.95 m
3
s
/hr. : 720 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Operation Burner pressure (max.) : 6.0 mbar (*) : 29.2 mbar in Hot appliance Burner pressure (max.) : 5.0 mbar (**) : 29.2 mbar Cold
Operation Burner pressure (max.) : 9.0 mbar (*) : 29.2 mbar in external Hot operating unit Burner pressure (max.) : 8.0 mbar (**) : 29.2 mbar Cold
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
443x140 mm Natural gas
: IGP
443x140 mm Propane Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 1200 : no 18 / 280 (= 7x Ø1.27 mm) (= 7x Ø0.62 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
78
Bellfi res
English
Instructions for use and installation instructions
Model : RETRO BELL SMALL
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3P Propane G31
Nominal heat input (Gross calorifi c value) : 8.0 kW : 7.5 kW Nominal heat output : 5.8 kW : 5.1 kW Effi ciency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.76 m
3
s
/hr. : 570 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Burner pressure (max.) Hot : 17.0 mbar(*) : 29.2 mbar
Burner pressure (max.) Cold : 16.2 mbar(**) : 29.2 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
313x140 mm Natural gas
: IGP
313x140 mm Propane Primary air inlet main burner : 1x Ø15.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 560 : no 18 / 220 (= 7x Ø0.90 mm) (= 7x Ø0.56 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
79
Bellfi res
English
Instructions for use and installation instructions
Model : CORNER BELL SMALL
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3P Propane G31
Nominal heat input (Gross calorifi c value) : 8.3 kW : 8.5 kW Nominal heat output : 6.0 kW : 5.7 kW Effi ciency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.79 m
3
s
/hr. : 640 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Burner pressure (max.) Hot : 17.0 mbar(*) : 29.2 mbar
Burner pressure (max.) Cold : 16.0 mbar(**) : 29.2 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
626x140 mm Natural gas
: IGP
636x140 mm Propane Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 560 : no 18 / 260 (= 7x Ø0.90 mm) (= 7x Ø0.60 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
80
Bellfi res
English
Instructions for use and installation instructions
Model : HORIZON BELL MEDIUM
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3+ Butane/Propane G30/G31
Nominal heat input (Gross calorifi c value) : 10.5 kW : 8.0 kW Nominal heat output : 7.5 kW : 5.6 kW Effi ciency class : 2 (80%) : 2 (78%) NOx-class : 5 : 5
Gas rate (max.) : 1.00 m
3
s
/hr. : 560 gr/hr.
Supply pressure : 20.0 mbar : G30: 28.0 mbar G31: 37.0 mbar
Burner pressure (max.) Hot : 11.8 mbar(*) : 28.5 mbar
Burner pressure (max.) Cold : 10.9 mbar(**) : 28.5 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
758x140 mm Natural gas
: IGP
758x140 mm Propane Primary air inlet main burner : 1x Ø20.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 1200 : no 18 / 220 (= 7x Ø1.27 mm) (= 7x Ø0.56 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
81
Bellfi res
English
Instructions for use and installation instructions
Model : HORIZON BELL SMALL
HORIZON BELL SMALL TUNNEL
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3P Propane G31
Nominal heat input (Gross calorifi c value) : 9.5 kW : 9.5 kW Nominal heat output : 6.8 kW : 6.4 kW Effi ciency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.90 m
3
s
/hr. : 720 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Burner pressure (max.) Hot : 16.8 mbar(*) : 29.3 mbar
Burner pressure (max.) Cold : 15.9 mbar(**) : 29.3 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner HBS : IGP
758x140 mm Natural gas
: IGP
758x140 mm Propane
Main burner HBST : IGP
828x140 mm Natural gas
: IGP
828x140 mm Propane Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 650 : no 18 / 280 (= 7x Ø0.96 mm) (= 7x Ø0.62 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
82
Bellfi res
English
Instructions for use and installation instructions
Model : VERTICAL BELL LARGE
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3P Propane G31
Nominal heat input (Gross calorifi c value) : 10.0 kW : 9.5 kW Nominal heat output : 6.7 kW : 6.3 kW Effi ciency class : 2 (74%) : 2 (74%) NOx-class : 5 : 5
Gas rate (max.) : 0.95 m
3
s
/hr. : 720 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Burner pressure (max.) Hot : 18.0 mbar(*) : 29.3 mbar
Burner pressure (max.) Cold : 17.0 mbar(**) : 29.3 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
313x140 mm Natural gas
: IGP
313x140 mm Propane Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 700 : no 18 / 280 (= 7x Ø0.99 mm) (= 7x Ø0.62 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
83
Bellfi res
English
Instructions for use and installation instructions
Model : VERTICAL BELL LARGE TUNNEL
VERTICAL BELL SMALL
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I3P Propane G31
Nominal heat input (Gross calorifi c value) : 9.5 kW : 6.8 kW Nominal heat output : 6.8 kW : 4.6 kW Effi ciency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.91 m
3
s
/hr. : 510 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Burner pressure (max.) Hot : 17.0 mbar(*) : 29.5 mbar
Burner pressure (max.) Cold : 16.0 mbar(**) : 29.5 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
313x140 mm Natural gas
: IGP
313x140 mm Propane Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 700 : no 18 / 220 (= 7x Ø0.99 mm) (= 7x Ø0.56 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS or ONTOP concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
84
Bellfi res
English
Instructions for use and installation instructions
Model : VIEW BELL VERTICAL
Country :
GB; Great Britain/IE; Ireland
:
GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BL5625 : 0063BL5625 Type of appliance under CE-norm
: C11 / C
31
/ C
31S
: C11 / C
31
/ C
31S
Category of appliance : I2H Natural gas G20 : I
3B/P
Butane G30/Propane G31
Nominal heat input (Gross calorifi c value) : 8.5 kW : Butane (G30) : 8.7 kW Propane (G31) : 7.2 kW
Nominal heat output (max.) : 5.8 kW : 4.5 - 5.5 kW Effi ciency class : 2 (75%) : 2 (70%) NOx-class : 5 : 5
Gas rate (max.) : 0.81 m
3
s
/hr. : Butane (G30) : 640 gr/hr.
Propane (G31) : 510 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Burner pressure (max.) Hot : 13.0 mbar(*) : 29.0 mbar
Burner pressure (max.) Cold : 12.0 mbar(**) : 29.0 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (hand control) : BM 733-234484 : BM 733-234484 Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60
Main burner : IGP
313x140 mm Natural gas
: IGP
313x140 mm Propane Primary air inlet main burner : 1x Ø15.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 700 : no 18 / 220 (= 7x Ø0.99 mm) (= 7x Ø0.56 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 37 (SIT 0.977.132) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
85
Bellfi res
English
Instructions for use and installation instructions
9 REPLACEMENT PARTS LIST
When requesting service or ordering replacement parts, please quote the model type and serial number. All parts listed in this manual may be ordered from a
Bellfi res dealer.
No. Article no. Description
1 310995 Gas regulator block, BM 733 - 234484 (M9 Thermocouple connection) 2 301983 Nut Ø4 mm BM for pilot light pipe 3 301989 Olive Ø4 mm BM for pilot light pipe 4 301985 Nut Ø8 mm BM for burner pipe 5 301984 Olive Ø8 mm BM for burner pipe
6 302422 Gas regulator block and remote control set; GV 60 (M10 Thermocouple connection) 7 302083 Plug 3/8 GV 34 / GV 60 8 302084 Nut Ø8 mm for burner supply GV 34 / GV 60 9 302089 Olive Ø8 mm for burner supply GV 34 / GV 60 10 302085 Nut Ø12 mm for gas supply GV 34 / GV 60 11 302090 Olive Ø12 mm for gas supply GV 34 / GV 60 12 302086 Cut-off nipple Ø4 mm GV 34 / GV 60 13 302067 Cable (sw): Receiver - Thermocouple interrupter, L = 500 mm 14 302150 Switch with short length of cable to thermocouple interrupter and long length of cable (tc), L= 500 mm, to receiver 15 310991 Hand-held transmitter: Display screen: Temperature and two programmes, receiver and 8 wire connecting cable L = 500 mm 16 302424 Hand-held transmitter: Display screen: Temperature and two programmes 17 302420 Receiver GV 60 18 302068 8 Wire connecting cable L = 500 mm 19 302421 Ignition cable 2x (2.8 x 0.5 mm) L = 1500 mmm
20 301971 Thermocouple M10 - 400 mm 21 321926 Thermocouple M10 - 1500 mm 22 301970 Thermocouple interrupter M10
23 310908 Pilot light set outer casing, Double fl ame
24 310909 Packing pilot light set outer casing 25 324063 Pilot light injector; natural gas; no 37 26 310912 Pilot light injector; propane; no 23 27 310907 Piezo electrode for pilot light; 2.8 x 0.5 mm 28 302062 Nut piezo electrode 29 310905 Pilot light olive; Ø4 mm 30 301976 Pilot light nut; Ø4 mm
31 ............ Pilot light pipe; Ø4 mm, L=….mm
32 ............ Burner pipe; Ø8 mm, L= …mm
86
Bellfi res
English
Instructions for use and installation instructions
Article no: 311011 311012 311003 321633 312914 311002 310937
311880 2 3
311880 2 3
311883 1 1 2
311883 1 1 2
311879 1 2
311884 2 3
311879 1 2
311879 1 2
311883 1 1 2
311879 1 2
311879 1 2
311879 1 2
311880 2 3
311880 2 3
311880 2 3
319345 1 2
321634 1 2
319345 1 2
Derby
Derby II
Jersey
Flat Bell
Topsham
Topsham Tunnel
York
Kent
Retro Bell Intermediate
Retro Bell Small
View Bell Small
Corner Bell Small
Horizon Bell Medium
Horizon Bell Small
Horizon Bell Small Tunnel
Vertical Bell Large
Vertical Bell Large Tunnel
Vertical Bell Small
Marble pebbels
Marble pebbles Color: white or grey 2,5 kg.
Log setAppliance
Log set consists of:
Log set Log Log set Log set Log set Embers Large, 5-piece Large Small, 5-piece Large, 7-piece Branches, 7-piece 2 bags à Inc. 2 bags 1x (Extension set) Inc. 2 bags Inc. 2 bags 100 gram embers à 100 embers à 100 embers à 100 gram gram gram
Logs - Embers - Marble pebbles
87
Bellfi res
English
Instructions for use and installation instructions
(*) : Marble pebbles, of which a maximum of 2000 grams may be placed on and around the burner.
Appliance Log set Marble Marble pebbles pebbles set (white) set (grey)
Set Log no
Article no:
D ...........
View Bell Vertical
Chips of
Embers with Vermiculite no 4
wood-set
Glow-effect black
Anthracite fi ltered
1
xxxxxx
1x
2
xxxxxx
-
3
xxxxxx
1x
4
xxxxxx
1x
6
xxxxxx
1x
7
xxxxxx
-
8
xxxxxx
-
5
xxxxxx
-
3 pieces
xxxxxx
1x
Bag: 125 gr.
301863
1x
Bag: 100 gr.
xxxxxx
1x
Bag: 2,5 kg.
310937
1x (*)
Bag: 2,5 kg.
xxxxxx
1x (*)
Logs - Chips of wood - Embers - Vermiculite granules - Marble pebbles
88
Bellfi res
English
Instructions for use and installation instructions
10. DISPOSING OF PACKAGING AND APPLIANCE
The appliance comes in recyclable packaging. This can include:
• Cardboard
• Wood
• Plastic
• Paper
Such materials must be disposed of responsibly, in line with local regulations.
Batteries should be disposed of as chemical waste. Batteries must be disposed of responsibly, in line with local regulations.
The authorities or fi tter can provide you with information on responsible disposal of obsolete appliances.
89
Bellfi res
English
Instructions for use and installation instructions
03 - 010509 - 322907
INTERFOCOS B.V. HALLENSTRAAT 17 5531 AB BLADEL NEDERLAND E-mail: info@interfocos.nl Internet: www.interfocos.com
Loading...