Bellfires Free Bell Installation Instructions And Instructions For Use

INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE
Wall-mounted gas fi re with closed combustion system
FREE BELL
Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re
This document is an essential part of your gas fi re.
Read it carefully before installation and use of the
gas fi re and keep it in a safe place!
3
Bellfi res
English
Instructions for use and installation instructions
BELLFIRES WALL-MOUNTED GAS FIRE WITH CLOSED COMBUSTION SYSTEM:
FREE BELL
4
Bellfi res
English
Instructions for use and installation instructions
5
Bellfi res
English
Instructions for use and installation instructions
CONTENTS
Page
1. WARRANTY TERMS ................................................................................. 7
2. INSTRUCTIONS FOR USE ....................................................................... 9
3. INSTALLATION INSTRUCTIONS .............................................................. 20
4. MAINTENANCE ......................................................................................... 45
5. FAULTS ...................................................................................................... 46
6. ACCESSORIES ......................................................................................... 47
7. ELECTRICAL DIAGRAM ........................................................................... 48
8. DIMENSIONS ............................................................................................ 49
9. TECHNICAL DETAILS/REGULATIONS .................................................... 51
10. REPLACEMENT PARTS LIST .................................................................. 52
11. DISPOSAL OF PACKAGING AND APPLIANCE ....................................... 54
6
Bellfi res
English
Instructions for use and installation instructions
7
Bellfi res
English
Instructions for use and installation instructions
Bellfi res gas fi re
Warranty
Bellfi res guarantees the quality of the supplied hearth and the quality of the materials used.
This warranty runs for a period of twelve (12) months from fi rst use of the hearth and covers defects which are a result of construction faults or the failure of component parts.
Bellfi res has an obligation under the terms of this warranty (at its discretion) not to charge for the replacement of any component parts.
Note: The following aspects are not covered under the terms of the warranty:
- defects arising which are attributable in whole or in part to: a Not paying due heed to installation, operating and maintenance instructions b Fitting/installation or repair by third parties (including the buyer) c Heat cracks arising in the jacket due to normal heating d Discolouration in the ironwork as a result of heat transfer
- the grate, the thermocouple and the glass of the product
Should you wish to claim under the warranty,
please contact your dealer.
Please carefully retain your invoice with this warranty!
Your Bellfi res dealer: Date of installation:
Bellfi res
Hallenstraat 17
NL-5531 AB Bladel
Tel. + 31 497 339200 Fax. + 31 497 339210
1 WARRANTY TERMS
8
Bellfi res
English
Instructions for use and installation instructions
9
Bellfi res
English
Instructions for use and installation instructions
2 INSTRUCTIONS FOR USE
2.1 INTRODUCTION
Congratulations on your purchase of this modern Bellfi res wall-mounted gas fi re. This quality product will provide you with many years of enjoyment due to the fl ame effect and warmth that it provides. Please read the instructions for use carefully before using the appliance for the fi rst time. Keep this booklet in a safe place.
2.2 BUILT-IN PROTECTION OF THE APPLIANCE
The appliance is fully protected by means of a thermo-electric pilot light shut off in the event of a gas escape from the main burner.
2.2.1 Safety
Do not place embers, vermiculite granules, wood logs or pebbles against the pilot light burner. Make sure that the pilot fl ame can burn at all times freely over the main burner. Only in this way is proper ignition of the main burner ensured. Ignoring these directions could lead to a dangerous situation.
It is essential that the appliance, the complete concentric fl ue system and the outlet are cleaned and inspected annually by a recognised fi tter/gas specialist. The safe operation of the appliance will thus remain guaranteed. See for additional instructions Chapter 4: Maintenance.
If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
The gas fi re must never be used with the door open or the door glass removed.
Never place fl ammable material on the ceramic log set.
The fi lling of the main burner with embers, vermiculite granules, wood logs and pebbles may not under any circumstances be changed or added to.
Do not place easily-fl ammable materials, such as nylon clothing or fl ammable liquids, in the vicinity of the gas fi re.
10
Bellfi res
English
Instructions for use and installation instructions
Ensure at all times that children and other people who are not aware of the operation of the gas appliance are only in the vicinity of the appliance exclusively under supervision.
Use a fi reguard to protect the people and children mentioned above against possible burns.
2.3 OPERATION: REMOTE CONTROL
2.3.1 General
Read these instructions carefully before lighting the fi re!
The appliance is opperated by radio remote control. This comprises a hand-held transmitter and a receiver. The receiver is part of the gas control block assembly.
The receiver and the gas control block are behind the frame at the bottom of the appliance.
The hand-held transmitter and receiver are powered by batteries. Hand-held transmitter : 1x 9V battery. Receiver : 4x 1.5V battery type LR6 or AA. Option: 6V adapter (230 VAC). Available from your fi tter.
Note: Hand-held transmitter and receiver are not interchangeable with previous models.
2.3.2 Hand-held transmitter
The remote control works by radio signal. The hand-held transmitter is confi gured in the factory with a unique signal code.
11
Bellfi res
English
Instructions for use and installation instructions
Figure 1: Hand-held transmitter
Set the display
• Connect the batteries. By simultaneously pressing OFF and (small fl ame), can be switched from °F (and 12 hour clock) to °C (and 24 hour clock), or vice versa.
• The display will automatically return to mode after some time, but you may immediately return to mode by pressing the OFF button.
Set the current time
• By simultaneously pressing (large fl ame) and (small fl ame), the display fl ashes. You are in SET mode.
• While the screen is fl ashing, you can adjust the time.
• Press (large fl ame) to set the hour and (small fl ame) to set the minute.
• Wait or press OFF to return to mode.
Important: Setting up signal code before using the appliance for the fi rst time.
Before the appliance can be used, the receiver must fi rst learn the hand-held transmitter’s signal code.
• Press the “RESETbutton on the receiver, and keep this pressed until 2 audio signals
are heard. See fi gure 2. Release the “RESETbutton after the second (somewhat longer) audio signal.
• Press, within 20 seconds, the (small fl ame) button on the hand-held transmitter,
until a somewhat longer signal is heard. The signal code has now been set up on the receiver.
You only need to set up the signal code once. It is not necessary when changing the batteries of the hand-held transmitter or receiver.
12
Bellfi res
English
Instructions for use and installation instructions
Figure 2: Receiver “RESET” button
Operating possibilities
It is possible to use the remote control in 3 ways to operate the appliance:
1 :
2 : and
3 :
You can cycle through the menu with operating possibilities by repeatedly depressing the SET button.
At the selected starting time (P1 or P2 ) or stopping time (P1 or P2
) is
also shown.
Returning to is also possible by pressing the (small fl ame) or
(large fl ame)
button.
Manual operation
Here you can turn the burner on and off, and adjust the height of the fl ames.
• Press (large fl ame) to turn on the burner and to increase the fl ame height.
• Press
(small fl ame) decrease the fl ame height to turn the burner off.
The pilot light will keep burning. (Stand-by position)
13
Bellfi res
English
Instructions for use and installation instructions
The appliance will automatically revert to stand-by if:
° the hand-held transmitter is outside the range of the receiver for more
than 6 hours.
° the batteries in the hand-held transmitter are almost depleted. ° the batteries in the receiver are fully depleted.
• When one of the buttons on the hand-held transmitter is pressed (except
the SET button), the transmission symbol
appears on the screen.
The receiver confi rms the transmission with an audio signal.
Operating day temperature thermostat
(Appliance is in the stand-by position and the pilot light is burning.)
Automatic temperature regulation of the pre-set day temperature. The room temperature is measured and compared with the pre-set day temperature. The fl ame height is automatically regulated so as to reach the pre-set day temperature. Also see: Setting the desired temperature.
Operating the night temperature thermostat
(Appliance is in the stand-by position and the pilot light is burning.) Automatic temperature regulation of the pre-set night temperature. The room temperature is measured and compared with the pre-set night temperature. The fl ame height is automatically regulated so as to reach the pre-set night temperature. Also see: Setting the desired temperature.
Timer operation
(Appliance is in the stand-by position and the pilot light is burning.)
Appliance functions automatically according to the two pre-set heating periods;
P1 and P2. These heating periods repeat automatically every 24 hours. Also see: Programming the timer: P1 and P2.
The appliance works thermostatically at the pre-set starting times P1 and P2 and the room temperature is automatically regulated to the pre-set day temperature .
The appliance works thermostatically at the pre-set stopping times P1
and
P2
and the room temperature is automatically regulated to the pre-set night temperature . In order to allow the appliance to regulate the temperature at night, the night temperature must be set to at least 5°C.
If the setting is lowered to , the appliance will switch to stand-by at night. The appliance will automatically operate at the following day cycle .
N.B.: The pre-set temperature is shown on the screen every 30 seconds.
14
Bellfi res
English
Instructions for use and installation instructions
Setting the desired temperature
• Select the desired mode of operation or
by pressing the SET button
briefl y.
• Hold the SET button until the display fl ashes.
• Set the temperature with (large fl ame) or (small fl ame).
• Wait or press the OFF button briefl y to go to mode.
• If the temperature control in should be off (lower battery consumption), decrease the night temperature until appears on the display.
Important: Place the hand-held transmitter in a place that is not
infl uenced by direct sunlight, draught, heat from the appliance and other heat sources.
Programming the timer: P1 and P2
• Select the desired mode of operation
by pressing the SET button briefl y.
• Press the SET button until P1 (heating period 1) and the time fl ashes.
• Set the time for the beginning of the fi rst heating period by pressing (large fl ame) for houre and (small fl ame) for minute’setting.
• Press the SET button briefl y; P1
appears on the display. Set the time for the end
of the fi rst heating period.
• Press SET again to set the second heating period P2
(heat ON) and P2
(heat
OFF).
• Wait a moment or press OFF to switch back to
mode.
2.3.3 Operation (Remote Control)
Igniting the fi re
• Open the gas supply valve in the gas pipe to the fi re.
• Press the “O I” switch on the gas control block to the “I” position.
• Turn the operating knob on the gas control block to the ON position.
• Switch the hand-held transmitter to the
position.
• On the hand-held transmitter, press the «- OFF and (large fl ame) buttons simultaneously. A short tone will signal the start. Short beeps will then follow until the pilot light and main burner are ignited. Once the main burner has been ignited, the fl ame height will automatically rise to the maximum position.
Important: If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
If the pilot light does not ignite after 3 ignition attempts; close the gas tap and warn the fi tter.
Once the pilot light is burning, the main burner must ignite within 10 seconds automatically. If this does not happen, immediately close the gas tap and warn the fi tter.
If the main burner ignites with a pop; immediately close the gas tap and warn the fi tter.
15
Bellfi res
English
Instructions for use and installation instructions
Figure 3: Gas regulating block; Operating Knob in ON-position
Motor-Knob (in maximum position)
Microswitch
Operating Knob
Connection Piezo Igniter (only for MANual control)
ON/OFF Switch
8-wire
Receiver Jack
• Possible error messages: * 3x short audio signal, audible when the motor-knob operates: Receiver batteries need changing soon (having heard this signal, the appliance can be ignited another ten times approximately). * 5 second unbroken tone: Error. For example, one of the cables may not be properly connected, the “O I” switch is not in the “I” position. * 5 short beeps: Ignition of the pilot light and main burner failed. Possible cause: air in the pilot light pipe.
Important: If the pilot fl ame goes out, then wait for at least 5 minutes before repeating the above procedure.
Setting the fl ame height / extinguishing the fi re
• After ignition, the burner automatically sets the fl ames to the maximum height
.
• Press button (small fl ame) to lower the fl ames and to turn off the main burner
(Extinguishing the fi re: small fl ame button: pilot light remains burning!)
(Pressing briefl y the (small fl ame) button gradually lowers the fl ames to the low
position.)
• Press button (large fl ame) to increase the fl ame level and to turn on the burner. (Pressing briefl y the (large fl ame) button gradually increases the fl ames to the high position.)
16
Bellfi res
English
Instructions for use and installation instructions
Important: If you turn on the main burner by pressing the (large fl ame) button, it must ignite within 10 seconds. If this does not happen, immediately close the gas tap and warn the fi tter.
If the main burner ignites with a pop; immediately close the gas tap and warn the fi tter.
Switching off the appliance
• Press the
(small fl ame) button to lower the fl ames or to switch off the main burner.
• Then press the «-OFF button to switch off the appliance, including the pilot light.
• Press the “O I” switch (on the gas control block) to the “O” position. This conserves
battery life.
• If the appliance is not to be used for some time, please close the gas supply valve in the gas pipe.
Important: If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
Faults
• If the signals from the hand-held transmitter do not seem to be reaching the receiver, the cause may be:
* Spent batteries: replace the batteries. * An electronic problem: press the “RESET” button on the receiver.
• If the appliance regularly switches itself off, please contact your installer.
Replacing the batteries
• The hand-held transmitter/receiver batteries have a service life of approx. one year.
We recommend you use alkaline batteries.
• The batteries must be replaced whenever:
1 Hand-held transmitter: BATT appears in the display screen. 2 Receiver: 3x short audio signal, audible when the motor-knob
operates.
1 Hand-held transmitter:
* Open the cover on the back of the transmitter. * Carefully remove the 9V battery and disconnect it from the contact.
Do not pull the wires! * Connect the new battery and replace in the battery compartment. Close the cover.
17
Bellfi res
English
Instructions for use and installation instructions
2 Receiver:
* Carefully pull the receiver assembly out of the compartment. * Open the cover. * Remove the batteries from the battery compartment. * Place four new 1.5V batteries (LR6 or AA type) as indicated in the battery
compartment. The negative end (-) of the battery must always be at the contact spring end of the compartment.
* Close the cover and place the receiver back in its holder.
• If the batteries are inserted incorrectly, the electronics or drive may be irreparably
damaged.
• Only replace the batteries when the appliance has been completely switched off.
Figure 4: Gas regulating block; Operating Knob in MAN-position
2.3.4 Operation (Hand control)
In an emergency it is possible to operate the appliance manually. To do so, the ignition (piezo) cable must fi rst be removed and transferred carefully to the piezo connector on the gas control block.
Motor-Knob (in maximum position)
Microswitch
Operating Knob (in Position for Manual Ignition)
Metallic Core for Manual Ignition (recessed switch)
Connection Piezo Igniter (only for MANual control)
ON/OFF Switch
8 Wire
Receiver Jack
Piezo button (only for MANual control)
18
Bellfi res
English
Instructions for use and installation instructions
Igniting the fi re
• Open the gas supply valve in the gas pipe to the fi re.
• Switch the “O I” switch on the gas regulating block to the “I” position.
• Turn the motor-knob on the gas regulating block as far as it will go in a clockwise direction. The switch will audibly ‘click’.
• Turn the operating knob on the gas control block to the MAN position. A recessed switch within the knob will become visible.
• Press the recessed switch. Use a pen or similar instrument to do this.
Gas will now fl ow to the pilot light.
• While holding down the recessed switch, press the (square) piezo button several times (the piezo button is alongside the “O I” switch) to ignite the pilot light.
Check whether the pilot light has been lit through the glass.
• Once the pilot light is lit, the recessed switch must be kept down for a further ten seconds, after which it can be released.
Important: If the pilot fl ame goes out, then wait for at least 5 minutes before repeating the above procedure.
• Move the operating knob to the ON position. Depending on the position of the motor­knob, the burner will either ignite or not.
• By turning the motor-knob anti-clockwise to the desired position, the burner will ignite and the fl ame height can be controlled.
Important: • When the main burner is switched on by turning the motor knob to the left, the burner must
ignite within 10 seconds. If this does not happen, immediately close the gas tap and warn the fi tter.
• If the main burner ignites with a pop; immediately close the gas tap and warn the fi tter.
Extinguishing the fi re
• Turn the motor-knob on the gas regulating block as far as it will go in a clockwise
direction. The knob will audibly ‘click’. The burner is now switched off. The pilot light will remain lit.
Switching off the appliance
• Press the “O I” switch on the gas regulating block to the “O” position. The pilot light will be extinguished.
• If the gas fi re is not going to be used for a long period of time, it is recommended to close the gas supply valve to the fi re.
Important: If the pilot fl ame goes out for any reason, wait for 5 minutes before attempting to re-light it.
19
Bellfi res
English
Instructions for use and installation instructions
2.4 USING THE APPLIANCE FOR THE FIRST TIME
The gas fi re is coated with a lacquer layer resistant to high temperature. During the fi rst hours of operation, the burning in of the lacquer may result in an unpleasant smell. This is harmless, however. Operating the gas fi re at full capacity for a few hours, while venti­lating the room, will eliminate the smell. After using your gas fi re for the fi rst few times, you may be aware of a light deposit on the inside off the glass. This is caused by the paint curing. Once your fi replace has cooled down, this deposit can be removed with glass cleaner or ceramic hob cleaner.
2.5 DAILY MAINTENANCE
• Ensure that as little dust, and as few particles of cigarette smoke, candles and oil lamps as possible pollute the air in the room in which the appliance is used. Heating of these particles by the convection system of the appliance could lead to discoloration of the walls and ceiling. It is therefore very important to ensure that the room in which the appliance is located is suffi ciently ventilated. Regularly remove any dust deposits from behind the frame by means of a vacuum cleaner.
Important: If the glass is broken or cracked, it must be immediately replaced before operating the gas fi re again.
• If anything is spilt on the fi re, switch it off immediately and wait for it to cool down suffi ciently before cleaning. Never use scouring powder, aggressive cleaners or fi re polish on the gas fi re. Use only a dry lint free cloth.
• Heat resistant lacquer in aerosols can be obtained from your distributor. During the yearly maintenance, the lacquer can be used to repair small areas of damage.
The installation must only be carried out by a CORGI
registered installation engineer.
IMPORTANT
20
Bellfi res
English
Instructions for use and installation instructions
3 INSTALLATION INSTRUCTIONS
3.1 GENERAL
The gas fi re must be positioned and connected as a “room sealed system” (balance fl ue) appliance by a CORGI registered gas installation engineer in accordance with the following installation instructions, nationally and locally applicable regulations (see “Technical Details/ Regulations” at the rear of this manual). If you have any queries regarding the installation, please consult your local gas company.
Important: Before beginning the installation, check that the details on the rating plate correspond to the gas type and pressure to which the appliance will be connected.
The appliance is factory set to the correct tolerances. The pilot light is set to the correct level of consumption.
It is possible to install the gas fi re with either a wall or roof outlet, using the Barbas concentric fl ue Ø100 mm (inner) - Ø150 mm (outer) system. The fumes are exhausted naturally to the outside environment through the inner Ø100 mm pipe whereas the combustion air supply passes between the Ø100 mm and Ø150 mm pipes.
The gas fi re can be installed in a completely sealed or mechanically ventilated house without extra ventilation and/or fume extraction.
The appliance is a wall-mounted gas fi re, which can only be installed on a
wall constructed from non-fl ammable material.
When handling the frame, we advise you to use the special gloves supplied, and to leave them with the owner of the hearth after installation.
If an existing chimney is to be used, please consult your installer fi rst. If the chimney was previously used for a wood or coal fi re, then it should be cleaned by an expert.
3.2 BARBAS CONCENTRIC FLUE Ø100 MM - Ø150 MM SYSTEM
The appliance is in combination with the concentric fl ue system [Ø100 mm – Ø150 mm] (either rigid or fl exible) of Barbas compliant with the European CE norm for gas appliances, and may therefore only be used with this system. The guarantee is invalidated if the appliance is (completely or partially) installed using a different system. The Barbas concentric fl ue [Ø100 mm - Ø150 mm] system can be used with either a newly-built or existing chimney.
21
Bellfi res
English
Instructions for use and installation instructions
3.3 PREPARATION FOR INSTALLATION
The following preparation must be carried out before the gas fi re can be installed.
3.3.1 Instructions for positioning the outlet
3.3.1.1 Positioning the outlet for correct operation:
Roof-mounted outlet:
Figure 5: Roof-mounted outlet
This must be positioned at least 0.5 m from the roof edge; the apex of the roof can be disregarded.
Wall-mounted outlet:
Figure 6: Wall-mounted outlet
This must be positioned at least 0.5 m from:
• the corner of the building.
• the roof overhang, the rain gutter.
• balconies etc., unless the exhaust construction
extends to at least the face of the protruding section.
>0.5 m
>0.5 m
22
Bellfi res
English
Instructions for use and installation instructions
3.3.1.2. Positioning the outlet to avoid affecting the surrounding area
All listed “distances” in this section are no more than guidelines. For the exact minimum “distances”, please consult your national and local directives.
Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to:
A. A ventilation opening serving an occupied room, a toilet or a bathroom.
B. A heating air supply, when the supply fl ows through an occupied room.
C. A window that can be opened and that is near an occupied room, a toilet or a bathroom.
Roof-mounted outlet:
To avoid adverse effects Distance: outlet - A, B or C
At the same roof level. >3 m (*)
At a different roof level. >1 m (*)
At a lower positioned wall. >1 m
At a higher sloping surface. >3 m (**)
(*) If the required distance cannot be achieved, the outlet position rules take precedence.
(**) If the required distance cannot be achieved, the position of the outlet must be at least 1 m above the highest facade/roof.
23
Bellfi res
English
Instructions for use and installation instructions
Wall-mounted outlet:
To avoid adverse effects Distance: outlet - A, B or C
At walls in buildings with staggered Not permitted if A, B, or C are located heights. above the outlet.
On a wall - general. (*) Above the outlet: >2 m Below the outlet: >0.75 m Left and right of the outlet: >0.75 m
At <1 m from the roof overhang. >2 m
Beneath balconies, walkways etc. >2 m tot onderzijde van een uitstekend balkon of galerij.
Beneath balconies, walkways >2 m etc. where the outlet extends to the front.
To the garden or on the terrace. >2 m to the outside space. (**)
With respect to a facing wall. >2 m (if the distance from the facing wall is less, the criteria detailed for “On a wall - general” apply).
Enquire at your local gas company for the regulations relating to outlets
positioned opposite each other and outlet(s) in facade(s) that form an angle.
(*) These minimum distances do not apply if there is an obstruction between the outlet and A, B and C that protrudes at least 0.5 m from the wall and has a length exceeding the distance.
(**) This distance is not required if the outlet is situated at least 1 m higher than the intended area of the outside space.
If the outlet has a clearance of less than 0.5 m from the hard surface of a public area at a height of less than 2 m, it must be fi tted with an effective protector. The mesh size of the guard must not affect the correct operation of the appliance.
24
Bellfi res
English
Instructions for use and installation instructions
3.4 GENERAL SERVICES
3.4.1 The Fume Channel/Combustion Air Intake
The combined fume channel and combustion air intake requires one of the following
Barbas concentric fl ue system confi gurations.
Important: Due to the high temperature of the outer walls
(approx. 150°C), no fl ammable materials may be located or used in the vicinity of the fl ue system.
After installation, encase the entire concentric fl ue system with a heat resistant material between the fl oor of the fi rst storey and the outlet.
Ventilate the covered concentric fl ue by fi tting a grid near the fl oor and ceiling (on each fl oor).
Do not insulate the concentric fl ue.
Use the universal wall/fl oor support Ø150 mm to attach the covering of the concentric fl ue system [Ø100 mm - Ø150 mm], see 3.4.2, drawing number 36.
Figure 7: Application universal wall/fl oor support Ø150 mm From the fl oor of the fi rst storey as far as the vent
36
36
Use as a wall support Use as a fl oor support
25
Bellfi res
English
Instructions for use and installation instructions
Appliance: Distance Y Distance X (min.-max.) (min.-max.)
0.5 - 1.0 m 0 - 0.6 m -
1.0 - 3.0 m 0 - 2.0 m -
Figure 8: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Free Bell
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
Item descriptions:
see 3.4.2
Assemble
restriction plate
19, 54
1
4
23
10, 11, 12, 13, 50, 51, 52
23
X
Y
28, 56
0.16 m
Wall Termination Position
26
Bellfi res
English
Instructions for use and installation instructions
Figure 9: Vertical roof-mounted outlet without bend
Appliance: Distance Y (min.-max.)
2.0 - 8.0 m Width: B = 50 mm
8.0 - 12.0 m Width: B = 65 mm
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Free Bell
18
10, 11, 12, 13, 50, 51, 52
1
4
Y
28, 56
16
17
16
24
23
24 23
Item descriptions:
see 3.4.2
Assemble restriction plate
27
Bellfi res
English
Instructions for use and installation instructions
Figure 10: Vertical roof-mounted outlet with bend
Appliance: Distance Y1 (*) Distance X (*) Distance Y1 + Y2 (*) (min.-max.) (min.-max.) (min.-max.)
Free Bell 1.0 - 10.0 m 0 - 3.0 m 1.0 - 10.0 m Width: B = 30 mm
(*) : (Y1 + Y2) : X > 2 : 1
(vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
16
23
Y
2
X
10, 11, 12, 13, 50, 51, 52
14, 15, 53
Y
1
4
28, 56
23
23
17
24
1
Item descriptions:
see 3.4.2
Assemble restriction plate
28
Bellfi res
English
Instructions for use and installation instructions
Figure 11: Vertical chimney outlet using an existing lined chimney (Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Appliance: Distance Y (min.-max.)
2.0 - 8.0 m Width: B = 50 mm
8.0 - 12.0 m Width: B = 65 mm
Free Bell
1
4
28, 56
32
18
23
25, 55
26
29
7
5
29
30
10, 11, 12, 13, 50, 51, 52
Y
FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
Item descriptions:
see 3.4.2
Assemble restriction plate
29
Bellfi res
English
Instructions for use and installation instructions
Figure 12: Vertical chimney outlet using a lined chimney with a bend > 45° (Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
(*) : (Y1 + Y2+ Y3) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Y
2
Y
1
10, 11, 12, 13, 50, 51, 52
> 45°
X
Y
3
32 18 30
29
5
7
29 26
25, 55
23
28, 56
4
1
Item descriptions:
see 3.4.2
Assemble restriction plate
Appliance: Distance Y
1
(*) Distance X (*) Distance Y1 + Y2 + Y3 (*)
(min.-max.) (min.-max.) (min.-max.)
Free Bell 1.0 - 10.0 m 0 - 3.0 m 1.0 - 10.0 m Width: B = 30 mm
30
Bellfi res
English
Instructions for use and installation instructions
Figure 13: Vertical chimney outlet using an existing unsound lined chimney or when no chimney liners are present (Flexible Ø100 mm / Ø150 mm)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Appliance: Distance Y (min.-max.)
2.0 - 8.0 m Width: B = 50 mm
8.0 - 12.0 m Width: B = 65 mm
Free Bell
Y
7
6
8
1832
31
29
30
29
26
29
27
28 29
4
1
Fitting the ornamental hood
Item descriptions:
see 3.4.2
Assemble restriction plate
31
Bellfi res
English
Instructions for use and installation instructions
Figure 14: Vertical chimney outlet using an existing unsound lined chimney or when the chimney is unlined; with a bend >45
o
(Flexible Ø100 mm / Ø150 mm)
(*) : (Y1 + Y2+ Y3) : X > 2 : 1
(Vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 3.4.2
Y
3
Y
2
Y
1
X
> 45°
6
8
7
31 29
32 18
30 29
26
29
27
28
29
4
1
Fitting the ornamental hood
Assemble restriction plate
Appliance: Distance Y
1
(*) Distance X (*) Distance Y1 + Y2 + Y3 (*)
(min.-max.) (min.-max.) (min.-max.)
Free Bell 1.0 - 10.0 m 0 - 3.0 m 1.0 - 10.0 m Width: B = 30 mm
32
Bellfi res
English
Instructions for use and installation instructions
FIG. NO. DESCRIPTION
1 Wall-mounted gas fi re; Free Bell
2 -
3 -
4 Restriction plate (Various restriction plates are supplied with the appliance.)
5 Chimney, min. Ø150 mm internal, totally gas tight
6 Chimney or fi reproof sleeving. Min. Ø160 mm internal
7 Ø100 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI
8 Ø150 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI
9 -
FIG.
NO.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
DESCRIPTION
Twin-wall balanced fl ue pipe, l=500 mm, incl. and
Twin-wall balanced fl ue pipe, l=1000 mm, incl. and
Telescopic twin-wall balanced fl ue pipe, length = min. 325 mm / max. 440 mm, incl. and
Adjustable length twin-wall balanced fl ue pipe, length = 500 mm, incl. and
Twin-wall balanced fl ue elbow
90
o
, incl. and
Twin-wall balanced fl ue elbow
45
o
, incl. and
Vertical (roof) termination kit, length = 1360 mm (verti­cal), incl. , and
Adjustable roof fl ashing. Roof pitch 20o-45o (**), with lead fl ashing
Roof fl ashing for existing chimney or fl at roof.
Horizontal (wall) termination kit, l=600 mm (horizontally adjustable)), incl. , and one set of wall spacer plates
: Stainless steel locking band Ø150 mm, quick-fastening
: Silicone seal Ø150 mm
-
: Wall strap
Set of ceiling fi nishing plates / fi re stops
ART. /
ORDER
NO.
302289
302290
302291
302292
302297
302298
302295
302212
302213
302296
302293
302210
302294
302215
302214
Color(*) Application
RVS antr. RIGID FLEX
l
l
l
l
l
l
l
l
l
l
l
l
l
AVAILABLE COMPONENTS FOR THE BARBAS CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm
3.4.2 Item descriptions for fi gures 8 t/m 14.
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
33
Bellfi res
English
Instructions for use and installation instructions
FIG.
NO.
25
26
27
28
29
30
31
32
33
34
35
36
DESCRIPTION
Ceiling plate for transition Ø100 mm / Ø150 mm rigid -
Ø100 mm (fl ex.).
Stainless steel adapter piece (100) from fi re to fl exible, Ø100 mm external (rigid) x Ø107 mm internal (fl ex.). [appliance -
Ø100 mm fl ex.] and [Ø100 mm rigid - Ø100 mm fl ex.].
Stainless steel adapter piece (150) fi re to fl exible, Ø148 mm external (rigid) x Ø148 mm internal (fl ex.) [ap­pliance - Ø150 mm fl ex.].
Stainless steel locking band Ø150 mm. For adapter 150 [appliance - Ø150 mm fl ex.] Screw-fastening
Stainless steel screws Ø3.5 mm x Ø9.5 mm. For securing the fl exible concentric fl ue. (Minimum 3 screws per connection)
Hose clamp Ø100 mm. (Minimum 2 per connection)
Hose clamp Ø150 mm. (Minimum 2 per connection)
Vertical (roof) termination kit, L = 610 mm (vertical), incl. and . For the fl exible fl ue system.
Concentric T-piece with gauging orifi ce, incl. and
Concentric pipe with gauging orifi ce, L=165 mm, incl. and
90° concentric bend with inspection panel incl. and
Universal wall / fl oor support Ø150 mm
ART. /
ORDER
NO.
302189
302278
302279
302217
303776
304041
304042
302307
302301
302302
302303
321948
Color(*) Application
RVS antr. RIGID FLEX
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
309892
309891
309893
309897
309894
309895
309889
309896
309890
319441
309898
319442
Twin-wall balanced fl ue pipe, L= 500 mm, incl. and
Twin-wall balanced fl ue pipe, L=1000 mm, incl. and
Adjustable lenght twin-wall balanced fl ue pipe, L= 500 mm, incl. and
Twin-wall balanced fl ue “smooth” elbow 45o, incl. and
Twin-wall balanced fl ue “smooth” elbow 90o, incl. and
Horizontal (wall) termination kit, L= 600 mm horizontally adjustable), incl. , and one set of wall spacer plates
Ceiling plate for transition Ø100 mm / Ø150 mm rigid ­Ø100 mm fl ex
Stainless steel locking band Ø150 mm, quick-fastening
Stainless steel locking band Ø150 mm, Screw-fastening
Concentric T-piece with gauging orifi ce, incl. and
Concentric pipe with gauging orifi ce, L=165 mm, incl. and
90° concentric bend with inspection panel, incl. and
50
51
52
53
54
55
56
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
34
Bellfi res
English
Instructions for use and installation instructions
3.5 POSITIONING THE APPLIANCE AND ORNAMENTAL HOOD
Important: The appliance may only be installed on a wall constructed from non-fl ammable material.
To suspend the appliance, use the correct fi xing
method appropriate to the wall in question.
The total weight of the appliance and ornamental
hood is 70kg.
Flammable materials, such as curtains, should not be placed in the vicinity of the gas fi re. Minimum safe distance: 100 cm
Position the gas supply pipe so that it can easily be installed after suspending the appliance.
(*) : Color: RVS: Stainless steel self-colour, polished antr.: Anthracite colour lacquer, matt
(**) : Adjustable roof fl ashing for a slope > 45° can be supplied on request.
When installing a balanced-fl ue “closed” gas fi re in an existing chimney, ensure stain­less steel fl exible liners conforming with BS 316 are used to conduct the spent gases.
The room-sealed gas appliances have been approved in combination with the BARBAS (RIGID and FLEXIBLE) CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm according to the European CE norm for gas appliances and may therefore be used only in combination with this fl ue system.
35
Bellfi res
English
Instructions for use and installation instructions
3.5.1 Suspending the fi re place
Remove the frame by pulling the bottom edge free and lifting slightly upwards.
Carefully remove the glass by fi rst unscrewing the glass strips left, right and on the bottom a little, and then removing the glass strip fully along the top edge.
Fix the appliance to the wall using 4x Ø10 mm screws/expanding bolts.
Ensure that the appliance is hanging level and that the concentric exhaust vent / combustion air supply connection of the appliance is in perfect alignment with the hole
in the ceiling or wall!
The appliance comprises the following parts:
Floor cove (optional)
Ornamental hood (3 parts)
Fireplace
Frame
36
Bellfi res
English
Instructions for use and installation instructions
3.5.2 Connecting the concentric fl ue
Assemble the concentric fl ue system according to one of the examples in section 3.4.1, fi gure 8 to 14 inclusive. Distance; heart concentric fl ue to the wall, is 107 mm (minimum 90 mm, maximum 110 mm). Make sure that all connections are completely gas tight.
3.5.3 Connecting the gas
The gas connection Ø12 mm (3/8”) is located on the back of the appliance. Use only gas piping with a minimum diameter of 1/2” and a shut-off valve. Make the connection to the gas supply pipe.
Important: During gas connection, take care not to twist the gas regulating block. Make sure that both the gas regulating block and the supply pipes are not subjected to stresses.
After connection of the gas supply, check that all connections are completely gas tight using soapy water or a leak tester.
150 420
37,5
671
28
300
740
384
107
Floor
125,5
Ø154 (Ext.) Ø150 (Int.)
Ø108 (Ext.) Ø100,8 (Int.)
Gas connection
2200
Variable
±1700 to ±2600
At 300 height:
variable from
±2000 to ±2900
*
**
*
* = position of fi xing holes
37
Bellfi res
English
Instructions for use and installation instructions
Figure 15: Gas regulating block Remote control
(Tab 2.8 x 0.8 mm) Connection piezo cable (Hand Control)
Side-inlet
Inlet Pressure Tap
Thermo Unit Connection
Minimum Rate Adjustment Screw
Motor-Knob
Operating-Knob
Pilot Gas Adjustment (with Screwdriver)
Maximum Rate Adjustment Screw
Side-outlet
Outlet Pressure Tap
Bottom Outlet
Bottom Inlet
Figure 16: Gas regulating block Remote control
Microswitch
Motor-Knob
Operating-Knob
(Remote control Hand control)
Connection
Piezo Igniter
(Hand control)
Piezo Igniter
(Hand control)
O I” Switch
8-Wire Receiver Jack
Connection
Pilot Gas
38
Bellfi res
English
Instructions for use and installation instructions
3.5.4 Positioning the ceramic log set, marble pebbles and ceramic stones
The appliance can be supplied with:
• Ceramic log set + embers
• Ceramic stones
• Marble pebbles
Important: • Carefully place the embers, set of logs, the ceramic stones or the marble pebbles on and around the main burner according to the directions in this chapter.
• Do not place any embers, logs, marble pebbles or stones against the pilot light burner. For that reason, the main burner
has a protective pilot-light cowl. Never remove this cowl! Make sure that the pilot fl ame can burn at all times freely over the main burner. Only in this way is proper ignition of the main burner ensured. Ignoring these directions could lead to a dangerous situation.
• The burner bed (with embers) and the positioning of the logs, marble pebbles or stones must not be changed.
• Only use those items supplied! Thesebeen rigorously
checked and the quantities adapted to the appliance.
• Replacement parts, including the ceramic mat are available from your dealer.
• Fitting may only be carried out by a qualifi ed person.
3.5.4.1 Ceramic log set + embers
NATURAL GAS APPLIANCE:
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Remove the embers (2x 100 gram) carefully from their packaging and spread them
evenly over the burner mat and the grate around the burner.
Note ! Small embers and their residue should not be scattered on
the burner. This can cause a blockage on the burner orifi ces.
3 Place the logs on the burner. See fi gure 17.
39
Bellfi res
English
Instructions for use and installation instructions
Figure 17: Log set Free Bell (Natural gas and propane)
PROPANE APPLIANCE:
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Remove the embers (2 x 100 gram) carefully from their packaging and spread them
evenly over the burner mat (not on the holes) and the grate around the burner.
Please make sure that all burner orifi ces (small holes) are kept unblocked!
Note ! Small embers and their residue should not be scattered on
the burner. This can cause a blockage on the burner orifi ces.
3 Place the logs on the burner. See fi gure 17. Note ! Do not place any logs above the burner openings!
Please make sure that all burner orifi ces (small holes) are kept unblocked!
Keep the burner orifi ces unblocked
Embers and logs must not be placed next to the pilot light burner
40
Bellfi res
English
Instructions for use and installation instructions
3.5.4.2 Ceramic stones
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Distribute a maximum of 12 stones evenly over the bed of the burner. Do not block
the burner openings! Make sure that the pilot light remains free at all times.
See fi gure 18.
Figure 18: Positioning stones Free Bell (Natural gas and propane)
Do not block the pilot light
41
Bellfi res
English
Instructions for use and installation instructions
3.5.4.3 Marble pebbles
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Spread the pebbles over the whole burner bed (burner and grid around the burner).
Make sure that the pilot light remains free.
Figure 20: Marble pebbles-set PROPANE
IMPORTANT: Open area, in order to ensure free
accessibility of the pilot fl ame to the burner
Keep the burner orifi ces unblocked
Figure 19: Marble pebbles-set NATURAL GAS
IMPORTANT: Open area, in order to ensure free
accessibility of the pilot fl ame to the burner
42
Bellfi res
English
Instructions for use and installation instructions
Important: • Do not place any marble pebbles in front of the pilot light. Make sure that the pilot light can burn freely over the main burner.
• Keep the burner orifi ces unblocked
Only this way a proper ignition of the main burner is ensured.
3.5.5 Mounting fl ue gas restriction plate
Depending on the length and shape of the concentric fl ue system and the chimney construction, you should, if indicated, fi t a restriction plate with a certain width (B) into the ceiling of the combustion chamber. To do this, see the set-up options as listed in fi gure 8 through 14.
Important: Ensure that the correct fl ue gas restriction plate is mounted. Use of the correct fl ue gas restriction plate will provide
optimum effi ciency, fl ame effect and combustion. Mounting an incorrect fl ue gas restriction plate can result in damage to the gas fi re.
Figure 21: Positioning restriction plate
Assembly restriction plate
43
Bellfi res
English
Instructions for use and installation instructions
The following restriction plates are supplied:
Restriction plate: Width: B = 30 mm Width: B = 50 mm Width: B = 65 mm
3.5.6 Fitting the glass
Once the logs / stones / marble pebbles have been placed and, if necessary, the restriction plate has been installed, the glass can be replaced. The bolts and/or screws used to secure the glass must be HAND TIGHTENED. Do not turn too tight, as this can
cause the glass to crack!
3.5.7 Fitting the ornamental hood
The ornamental hood comprises 3 parts: 1. rose
2. upper ornamental pipe
3. lower ornamental pipe
1
2
3
44
Bellfi res
English
Instructions for use and installation instructions
1 Place the rose around the concentric fl ue and screw this to the ceiling. 2 Push the top end of the upper ornamental pipe into the rose and screw the bottom end securely to the wall. 3 Hook the bottom end of the lower ornamental pipe behind the top plate of the appliance. Then screw the top end securely to the wall.
3.5.8 Placing the frame
Place the frame on the appliance by hooking in the top edge and then pushing the bottom edge backwards until the magnetic clips click into place. The frame can be ad­justed by turning the magnets.
Caution: Only assemble the frame after the wall has been fi nished. Use the supp­lied protective equipment (gloves or polishing cloth). Do not use masking tape!
3.5.9 Checking the appliance following installation
After installation, visually check the gas fl ame. When the fi re is ignited, the fl ames should be short and blue/yellow in colour. These fl ames should gradually increase in height and become more yellow. When all fl ames are yellow, the gas fi re has reached the correct temperature.
THE GAS FIRE IS NOW READY FOR USE
2200
Variable
±1700 to ±2600
At 300 height:
variable from
±2000 to ±2900
28
300
740
Floor
125.5
140
140
460
50
45
Bellfi res
English
Instructions for use and installation instructions
4 MAINTENANCE
4.1 ANNUAL MAINTENANCE
It is essential that the appliance, the complete concentric
fl ue system and the outlet are cleaned and inspected annually by a recognised fi tter/gas specialist. The safe operation of the appliance will thus remain guaranteed.
Maintenance consists of the following:
• Remove fi rst the embers and/or vermiculite granules, set of logs and/or pebbles
from the main burner and carefully clean these with a soft brush.
• Clean and inspect (visually) the main burner, pilot light, combustion chamber, fl ue system and combustion air intake. Dust can be removed using a vacuum cleaner.
• After cleaning;
Carefully replace the embers and/or vermiculite granules, set of logs and/or pebbles
on and around the main burner according to the installation directions in this instruction booklet.
Do not place any embers, vermiculite granules, logs or pebbles against the
pilot light burner. Make sure that the pilot fl ame can burn at all times freely
over the main burner. Only in this way is proper ignition of the main burner
ensured. Ignoring these directions could lead to a dangerous situation.
• Check the gas supply, fl ue system, and combustion air supply route for leaks.
• Check the correct operation of the gas regulating block, thermocouple circuit and the ignition of the main burner.
• Check the gas inlet-pressure (both when the appliance is off and when it burns at maximum) and the burner pressure.
• Check the complete concentric fl ue system including the outlet construction.
46
Bellfi res
English
Instructions for use and installation instructions
5 FAULTS
Possible reasons for the gas fi re going out are:
• The concentric fl ue system is not installed according to one of the methods detailed in Paragraph 3.4
• An incorrect “fl ue gas restriction plate” is fi tted.
• The pilot light extinguishes if fumes are not exhausted or are insuffi ciently exhausted.
• The pilot light is either dirty or defective.
• Insuffi cient gas pressure.
• Thermocouple voltage is too low. This is usually caused by insuffi cient heating of
the thermocouple by the pilot light.
• Dirty electrical contacts in the thermo-electrical system; for example, the thermocouple connection.
• Batteries in receiver or remote control are fl at.
47
Bellfi res
English
Instructions for use and installation instructions
6 ACCESSORIES
• Floor cove: article no.: 323062 (anthracite).
8
6.5
Ø12
33
20.5
14
24.5
16.25
8.25
8
Viewing window
R99.5
R98
199
107
1.5
300
312.5
Floor cove
48
Bellfi res
English
Instructions for use and installation instructions
7 ELECTRICAL DIAGRAM
Thermo­ couple
Ignition cable
Antenna
Button “Reset”
Motor­knob
Operating-Knob
O I” Switch
Gas regulating block
RECEIVER
Battery
Compartment
panel
4 AA Batteries
cable 2
cable 1
“red”
“black”
SPARK
SPARK
SW TC
SW TC
GR
SW
MA
MO
Pilot
ON/OFF Switch
Thermocurrent interrupter Block
“red”
“yellow”
Thermo ­current Interrupter Block
8 Wire Connecting Cable
49
Bellfi res
English
Instructions for use and installation instructions
8 DIMENSIONS
8.1 FREE BELL
2200
Variable
±1700 to ±2600
At 300 height:
variable from
±2000 to ±2900
28
300
740
Floor
125.5
140 140460
150
150 420
37.5
671
107
384
545
R272.5
50
Bellfi res
English
Instructions for use and installation instructions
950 50
Variable from
±950 (1 pipe) to ±1879.5 (2 pipes)
51
Bellfi res
English
Instructions for use and installation instructions
9 TECHNICAL DETAILS/REGULATIONS
National installation regulations: Gas safety installation and use regulations 1984 plus all relevant safety and building regulations concerning fi re installation
Model : FREE BELL
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland
Product identifi cation no : 0063BR3707 : 0063BR3707 Type of appliance under CE-norm : C11 / C31 : C11 / C
31
Category of appliance : I2H Natural gas G20 : I
3B/P
Butane G30 / Propane G31
Nominal heat input : 8.0 kW : Butane (G30) : 8.0 kW (Gross calorifi c value) Propane (G31): 7.0 kW
Nominal heat output : 5.8 kW : 4.5 - 5.2 kW Effi ciency class : 2 (72%) : 2 (72%) NOx-class : 5 : 5
Gas rate (max.) : 0.76 m
3
s
/hr. : 510 gr/hr.
Supply pressure : 20.0 mbar : 37.0 mbar
Burner pressure (max.) Hot : 17.0 mbar(*) : 29.2 mbar
Burner pressure (max.) Cold : 16.0 mbar(**) : 29.2 mbar
Burner pressure (min.) : 2.0 mbar : 5.0 mbar
Gas regulator block (remote control) : Mertik GV 60 : Mertik GV 60
Main burner : IGP : IGP Primary air inlet main burner : 1x Ø15.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 560 : no 18 / 220 (= 7x Ø0.891 mm) (= 7x Ø0.549 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm Concentric fl ue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block
(*) : When the appliance has reached its thermal equilibrium. (**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply: BARBAS concentric fl ue system Ø100 mm-Ø150 mm. Rigid and/or fl exible.
Heat changing surface: Entire front of the appliance.
52
Bellfi res
English
Instructions for use and installation instructions
10 REPLACEMENT PARTS LIST
When requesting service or ordering replacement parts, please quote the model type and serial number. All parts listed in this manual may be ordered from a Bellfi res dealer.
No. Article no. Description
1 310984 Gas regulator block and remote control set;
GV 60 (M10
Thermocouple connection) 2 302083 Plug 3/8 GV 34 / GV 60 3 302084 Nut Ø8 mm for burner supply GV 34 / GV 60 4 302089 Olive Ø8 mm for burner supply GV 34 / GV 60 5 302085 Nut Ø12 mm for gas supply GV 34 / GV 60 6 302090 Olive Ø12 mm for gas supply GV 34 / GV 60 7 302086 Cut-off nipple Ø4 mm GV 34 / GV 60 8 302067 Cable (sw): Receiver - Thermocouple interrupter, L = 500 mm 9 302150 Switch with short length of cable to thermocouple interrupter and long length of cable (tc), L= 500 mm, to receiver 10 310991 Hand-held transmitter: Display screen: Temperature and two programmes, receiver and 8 wire connecting cable L = 500 mm 11 302424 Hand-held transmitter: Display screen: Temperature and two programmes 12 302420 Receiver GV 60 13 302068 8 Wire connecting cable L = 500 mm 14 302421 Ignition cable 2x (2.8 x 0.5 mm) L = 1500 mm
15 301971 Thermocouple M10 - 400 mm 16 301970 Thermocouple interrupter M10 17 322057 Thermocouple reductable swivel M10 x M9
18 310908 Pilot light set outer casing, Double fl ame 19 310909 Packing pilot light set outer casing 20 310910 Pilot light injector; natural gas; no 36 21 310912 Pilot light injector; propane; no 23 22 310907 Piezo electrode for pilot light; 2.8 x 0.5 mm 23 302062 Nut piezo electrode 24 310905 Pilot light olive; Ø4 mm 25 301976 Pilot light nut; Ø4 mm
26 ............ Pilot light pipe; Ø4 mm, L=….mm
27 ............ Burner pipe; Ø8 mm, L= …mm
28 322559 Glass Free Bell
53
Bellfi res
English
Instructions for use and installation instructions
(*) : 1 set of large stones, of which only a maximum of 12 pieces may be placed on and around the burner.
(**) : Marble pebbles, of which a maximum of 2000 grams may be placed on and around the burner.
Logs - Embers - Stones - Marble pebbles
Log set consists of:
Log set Log Log set Log set Log set Embers
Large, 5-piece Large Small, 5-piece Large, 7-piece Branches, 7-piece 2 bags à
Inc. 2 bags 1x (Extension set) Inc. 2 bags Inc. 2 bags 100 gram
embers à 100 embers à 100 embers à 100
gram gram gram
Stones
Marble
pebbles
Set of
large
stones
Color: white
± 20 pieces
Marble
pebbles
Color: white
2.5 kg.
Article no: 311011 311012 311003 321633 312914 311002 311008 310937
311879 1x - - - - - 1x (*) 1x (**)
Free Bell
Appliance
54
Bellfi res
English
Instructions for use and installation instructions
11 DISPOSING OF PACKAGING AND APPLIANCE
The appliance comes in recyclable packaging. This can include:
• Cardboard
• Wood
• Plastic
• Paper
Such materials must be disposed of responsibly, in line with local regulations.
Batteries should be disposed of as chemical waste. Batteries must be disposed of responsibly, in line with local regulations.
The authorities or fi tter can provide you with information on responsible disposal of obsolete appliances.
55
Bellfi res
English
Instructions for use and installation instructions
03 - 151110 - 323010
INTERFOCOS B.V. HALLENSTRAAT 17 5531 AB BLADEL NEDERLAND E-mail: info@interfocos.nl Internet: www.interfocos.com
Loading...