Bellfires Topsham, Derby II, Jersey, View Bell, Topsham Tunnel Installation Instructions And Instructions For Use

...
INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE
Gas fires with closed combustion system
Bellfires wishes you many cosy evenings with your new Bellfires gas fire
This document is an essential part of your gas fire.
Read it carefully before installation and use of the
gas fire and keep it in a safe place!
Bellfires
English
Instructions for use and installation instructions
BELLFIRES GAS FIRES WITH CLOSED COMBUSTION SYSTEM:
Derby Derby II Jersey Flat Bell Topsham Topsham Tunnel York Kent
Retro Bell Large Retro Bell Intermediate Retro Bell Small Retro Bell Solo
View Bell Corner Bell Large Corner Bell Small
Horizon Bell XL Horizon Bell Large Horizon Bell Large Tunnel Horizon Bell Medium Horizon Bell Small Horizon Bell Small Tunnel
Vertical Bell Large Vertical Bell Large Tunnel Vertical Bell Small
Smart Bell
Bellfires
English
Instructions for use and installation instructions
Bellfires
English
Instructions for use and installation instructions
CONTENTS
1. WARRANTY TERMS .................................................................................
2. INSTRUCTIONS FOR USE .......................................................................
3. INSTALLATION INSTRUCTIONS ..............................................................
4. MAINTENANCE .........................................................................................
5. FAULTS ......................................................................................................
6. ELECTRICAL DIAGRAM ...........................................................................
7. DIMENSIONS ............................................................................................
8. TECHNICAL DETAILS/REGULATIONS ....................................................
9. REPLACEMENT PARTS LIST ..................................................................
10. DISPOSAL OF PACKAGING AND APPLIANCE .......................................
Page
7
9
19
67
68
69
70
83
97
99
Bellfires
English
Instructions for use and installation instructions
Bellfires
English
Instructions for use and installation instructions
Bellfires gas fire
Warranty
Bellfires guarantees the quality of the supplied hearth and the quality of the materials used.
This warranty runs for a period of twelve (12) months from first use of the hearth and covers defects which are a result of construction faults or the failure of component parts.
Bellfires has an obligation under the terms of this warranty (at its discretion) not to charge for the replacement of any component parts.
Note: The following aspects are not covered under the terms of the warranty:
- defects arising which are attributable in whole or in part to: a Not paying due heed to installation, operating and maintenance
instructions b Fitting/installation or repair by third parties (including the buyer) c Heat cracks arising in the jacket due to normal heating d Discolouration in the ironwork as a result of heat transfer
- the grate, the thermocouple and the glass of the product
Should you wish to claim under the warranty,
please contact your dealer.
Please carefully retain your invoice with this warranty!
Your Bellfires dealer: Date of installation:
Bellfires
Hallenstraat 17
NL-5531 AB Bladel
Tel. + 31 497 339200 Fax. + 31 497 339210
1. WARRANTY TERMS
Bellfires
English
Instructions for use and installation instructions
Bellfires
English
Instructions for use and installation instructions
2 INSTRUCTIONS FOR USE
2.1 INTRODUCTION
Congratulations on your purchase of this modern Bellfires gas fire. This quality product will provide you with many years of enjoyment due to the flame effect and warmth that it provides. Please read the instructions for use carefully before using the appliance for the first time. Keep this booklet in a safe place.
2.2 BUILT-IN PROTECTION OF THE APPLIANCE
The appliance is fully protected by means of a thermo-electric pilot light shut off in the event of a gas escape from the main burner.
2.2.1 Safety
Do not place embers, vermiculite granules, wood logs or pebbles against the pilot light burner. Make sure that the pilot flame can burn at all times freely over the main burner. Only in this way is proper ignition of the main burner ensured. Ignoring these directions could lead to a dangerous situation.
It is essential that the appliance, the complete concentric flue system and the outlet are cleaned and inspected annually by a recognised fitter/gas specialist. The safe operation of the appliance will thus remain guaranteed. See for additional instructions Chapter 4: Maintenance.
If the pilot flame goes out for any reason, wait for 5 minutes before attempting to re-light it.
The gas fire must never be used with the door open or the door glass removed.
Never place flammable material on the ceramic log set.
The filling of the main burner with embers, vermiculite granules, wood logs and pebbles may not under any circumstances be changed or added to.
Do not place easily-flammable materials, such as nylon clothing or flammable liquids, in the vicinity of the gas fire.
10
Bellfires
English
Instructions for use and installation instructions
Ensure at all times that children and other people who are not aware of the operation of the gas appliance are only in the vicinity of the appliance exclusively under supervision.
Use a fireguard to protect the people and children mentioned above against possible burns.
2.3 OPERATING YOUR GAS FIRE - GENERAL
Read these instructions carefully before lighting the fire! The gas fire can be operated with a pilot light that burns continuously. The ignition and
control knob is located at the bottom of the front of your gas fire or outside the gas fire in a special box (supplied). If the control knob is fitted to the front of the gas fire, the gas fire frame must be removed to access the knob.
The pilot light is situated in the front of the burner, behind a cowl. Should the pilot light
go out, you must wait five (5) minutes before attempting to re-ignite the fire.
Important
The burner is operated using the control knob. Select the required setting and the burner will then burn at this setting until it is changed.
2.4 HAND CONTROL
The burner is operated using the control knob. Select the required setting and the burner will then burn at this setting until it is changed.
“OFF” POSITION
IGNITION POSITION
CONTROL KNOB
BURNER CONTROL RANGE
Figure 1: Gas regulator block BM 733
11
Bellfires
English
Instructions for use and installation instructions
2.4.1 Igniting the fire
• Open the gas supply valve in the gas pipe to the appliance.
• Press in the control knob and turn it (clockwise) as far as possible. It is now in the “off” position.
• Press the control knob and turn it anti-clockwise to the “PILOT” ignition position. You will hear a click, which is the spark for the pilot light. You may have to “click” several times before the pilot light ignites.
• Once the pilot light is ignited, hold in the knob for another ten (10) seconds and then release it.
If the pilot flame goes out, then wait for at least 5 minutes before repeating the above procedure.
• The burner is ignited by turning the knob anti-clockwise to the desired setting.
2.4.2 Turning off the fire
Press the knob and turn it to “PILOT”. The burner will continue to burn for a few seconds before being extinguished.
2.4.3 Extinguishing the pilot light
You can extinguish the pilot light by pressing the control knob when it is in the “PILOT” position and turning it clockwise to the “OFF” position. If the gas fire is not going to be used for a long period of time, it is recommended to close the gas supply valve to the fire.
If the pilot flame goes out for any reason, wait for 5 minutes before attempting to re-light it.
If the pilot light frequently goes out, then please contact your installer.
2.5 REMOTE CONTROL
2.5.1 General
The appliance is opperated by radio remote control. This comprises a hand-held transmitter and a receiver. The receiver is part of the gas control block assembly.
The receiver and the gas control block are behind the (white) panel door (operating unit) next to the appliance. Press the door inwards to open; this will release the catch and the door will spring out. or:
The receiver and the gas control block are behind the operating flap at the bottom of the appliance. Pull the flap forward to open.
12
Bellfires
English
Instructions for use and installation instructions
2.5.2 Hand-held transmitter
The remote control works by radio signal. The signal code default setting is factory set, but may be modified if requierd.
Figure 2: Hand-held transmitter
Set the display
l Connect the batteries. By simultaneously pressing OFF and , can be
switched from °F (and 12 hour clock) to °C (and 24 hour clock), or vice versa.
l The display will automatically return to MAN mode after some time, but you
may immediately return to MAN by pressing the OFF button.
Set the current time
l By simultaneously pressing and , the display flashes. You are in SET mode. l Press to set the hour and to set the minute. l Wait or press OFF to return to MAN mode.
Programming the desired temperature
l Select the desired mode of operation or by pressing theSET button briefly. l Hold the SET button until the display flashes. l Set the temperature with or . l Wait or press the OFF button briefly to go to MAN mode.
l If the temperature control in should be off (lower battery consumption),
decrease the night temperature until appears on the display.
13
Bellfires
English
Instructions for use and installation instructions
Programming the timer: P1 and P2
l Select the desired mode of operation by pressing the SET button
briefly.
l Press the SET button until P1 (heating period 1) flashes. l Set the time for the beginning of the first heating period by pressing for hour and
for minute’setting.
l Press the SET button briefly; P1 appears on the display. Set the time
for the end of the first heating period.
l Press SET again to set the second heating period P2 (heat ON) and
P2 (heat OFF).
l If all 4 times are set, pressing the OFF button or waiting will complete
the programming.
Changing the signal code:
l 15 different codes can be set by changing the position of one or more “DIP switches”
in the hand-held transmitter.
l The “DIP switches” are concealed behind the battery holder in the hand-held
transmitter.
l Press the reset button on the receiver until a signal is heard. l Then hold down button
on the hand-held transmitter for 20 seconds.
l The receiver will then read the new code.
Figure 3: “DIP-switches” in battery compartment hand-held transmitter
2.5.3 Operation (Remote Control)
Igniting the fire
l Open the gas supply valve in the gas pipe to the fire. l Press the “O I” switch on the gas control block to the “I” position. l Turn the operating knob on the gas control block to the ON position. l On the hand-held transmitter, press the
««
««
«- OFF and buttons simultaneously. A
short tone will signal the start. Short beeps (0.2 secs, 1Hz.) will then follow until the pilot light and main burner are ignited. Once the main burner has been ignited, the flame height will automatically rise to the maximum position.
14
Bellfires
English
Instructions for use and installation instructions
Figure 4: Gas regulating block; Operating Knob in ON-position
l Possible error messages:
* Long beeps (0.8 secs on, 0.2 secs off) during ignition:
Receiver batteries need changing soon (having heard this signal, the appliance can be ignited another ten times approximately).
* 5 second unbroken tone:
Error. For example, one of the cables may not be properly connected, the “O I” switch is not in the “I” position.
* 5 short beeps (0.2 secs on, 0.2 sec off):
Ignition of the pilot light and main burner failed. Possible cause: air in the pilot light pipe.
Important: If the pilot flame goes out, then wait for
at least 5 minutes before repeating the above procedure.
Setting the flame height/extinguishing the fire
l After ignition, the burner automatically sets the flames to the maximum height. l Press the button to lower the flames or turn off the burner. (To extinguish the fire
select “STAND BY”.) (Touch the button to lower the flames gradually.)
l Press the button to raise the flames. (Touch the button to raise the flames
gradually.)
Motor-Knob (in maximum position)
Microswitch
Operating Knob
Connection Piezo Igniter (only for MANual control)
ON/OFF Switch
8 Wire
Receiver Jack
15
Bellfires
English
Instructions for use and installation instructions
Switching off the appliance
l Press the button to lower the flames or to switch off the burner (“STAND BY”). l Then press the
««
««
«-OFF button to switch off the appliance, including the pilot light.
l Press the “O I” switch (on the gas control block) to the “O” position. This conserves
battery life.
l If the appliance is not to be used for some time, please close the gas supply valve in
the gas pipe.
Important: If the pilot flame goes out for any reason,
wait for 5 minutes before attempting to re-light it.
Faults
l If the signals from the hand-held transmitter do not seem to be reaching the receiver,
the cause may be: * Spent batteries: replace the batteries. * An electronic problem: press the “RESET” button on the receiver.
l If the appliance regularly switches itself off, please contact your installer.
Replacing the batteries
l The hand-held transmitter/receiver batteries have a service life of approx. one year.
We recommend you use alkaline batteries.
l The batteries must be replaced whenever:
1. Hand-held transmitter: BATT appears in the display screen.
2. Receiver: long beeps (0.8 secs on, 0.2 secs off) are heard
during ignition.
1. Hand-held transmitter: * Open the cover on the back of the transmitter. * Carefully remove the 9V battery and disconnect it from the contact.
Do not pull the wires!
* Connect the new battery and replace in the battery compartment. Close the cover.
2. Receiver: * Carefully pull the receiver assembly out of the compartment behind the (white)
panel door. * Open the cover. * Remove the batteries from the battery compartment. * Place four new 1.5V batteries (LR6 or AA type) as indicated in the battery
compartment. The negative end (-) of the battery must always be at the contact
spring end of the compartment. * Close the cover and place the receiver back in its holder.
l If the batteries are inserted incorrectly, the electronics or drive may be irreparably
damaged.
l Only replace the batteries when the appliance has been completely switched off.
16
Bellfires
English
Instructions for use and installation instructions
2.5.4 Operation (Hand control)
In an emergency it is possible to operate the appliance manually. To do so, the ignition (piezo) cable must first be removed and transferred carefully to the piezo connector on the gas control block.
Motor-Knob (in maximum position)
Microswitch
Operating Knob (in Position for Manual Ignition)
Metallic Core for Manual Ignition (recessed switch)
Connection Piezo Igniter (only for MANual control)
Piezo button (only for MANual control)
ON/OFF Switch
8 Wire
Receiver Jack
Figure 5: Gas regulating block; Operating Knob in MAN-position
Igniting the fire
l Open the gas supply valve in the gas pipe to the fire. l Switch the “O I” switch on the gas regulating block to the “I” position. l Turn the motor-knob on the gas regulating block as far as it will go in a clockwise
direction. The switch will audibly ‘click’.
l Turn the operating knob on the gas control block to the MAN position. A recessed
switch within the knob will become visible.
l Press the recessed switch. Use a pen or similar instrument to do this.
Gas will now flow to the pilot light.
l While holding down the recessed switch, press the (square) piezo button several
times (the piezo button is alongside the “O I” switch) to ignite the pilot light. Check whether the pilot light has been lit through the glass.
l Once the pilot light is lit, the recessed switch must be kept down for a further ten
seconds, after which it can be released.
Important: If the pilot flame goes out, then wait for
at least 5 minutes before repeating the above procedure.
17
Bellfires
English
Instructions for use and installation instructions
l Move the operating knob to the ON position. Depending on the position of the motor-
knob, the burner will either ignite or not.
l By turning the motor-knob anti-clockwise to the desired position, the burner will ignite
and the flame height can be controlled.
Extinguishing the fire
l Turn the motor-knob on the gas regulating block as far as it will go in a clockwise
direction. The knob will audibly ‘click’. The burner is now switched off. The pilot light will remain lit.
Switching off the appliance
l Press the “O I” switch on the gas regulating block to the “O” position.
The pilot light will be extinguished.
l If the gas fire is not going to be used for a long period of time, it is
recommended to close the gas supply valve to the fire.
Important: If the pilot flame goes out for any reason,
wait for 5 minutes before attempting to re-light it.
2.6 USING THE APPLIANCE FOR THE FIRST TIME
The gas fire is coated with a lacquer layer resistant to high temperature. During the first hours of operation, the burning in of the lacquer may result in an unpleasant smell. This is harmless, however. Operating the gas fire at full capacity for a few hours, while ventilating the room, will eliminate the smell. After using your gas fire for the first few times, you may be aware of a light deposit behind the glass. This is caused by the paint curing. Once your fireplace has cooled down, this deposit can be removed with glass cleaner or ceramic hob cleaner.
2.7 DAILY MAINTENANCE
l Ensure that as little dust, and as few particles of cigarette smoke, candles and oil
lamps as possible pollute the air in the room in which the appliance is used. Heating of these particles by the convection system of the appliance could lead to discoloration of the walls and ceiling. It is therefore very important to ensure that the room in which the appliance is located is sufficiently ventilated. Regularly remove any dust deposits from behind the control flap by means of a vacuum cleaner.
Important: If the glass is broken or cracked, it must be
immediately replaced before operating the gas fire again.
18
Bellfires
English
Instructions for use and installation instructions
l If anything is spilt on the fire, switch it off immediately and wait for it to cool
down sufficiently before cleaning. Never use scouring powder, aggressive cleaners or fire polish on the gas fire. Use only a dry lint free cloth.
l Heat resistant lacquer in aerosols can be obtained from your
distributor. During the yearly maintenance, the lacquer can be used to repair small areas of damage.
The installation must only be carried out by a
CORGI registered installation engineer.
IMPORTANT
19
Bellfires
English
Instructions for use and installation instructions
3 INSTALLATION INSTRUCTIONS
3.1 GENERAL
The gas fire must be positioned and connected as a “room sealed system” (balance flue) appliance by a CORGI registered gas installation engineer in accordance with the following installation instructions, nationally and locally applicable regulations (see “Technical Details/ Regulations” at the rear of this manual). If you have any queries regarding the installation, please consult your local gas company.
Important: Before beginning the installation, check that the details on the
rating plate correspond to the gas type and pressure to which the appliance will be connected.
The appliance is factory set to the correct tolerances. The pilot light is set to the correct level of consumption.
It is possible to install the gas fire with either a wall or roof outlet, using the Barbas or Ontop (US-System) concentric flue Ø100 mm (inner) - Ø150 mm (outer) system. The fumes are exhausted naturally to the outside environment through the inner Ø100 mm pipe whereas the combustion air supply passes between the Ø100 mm and Ø150 mm pipes.
The gas fire can be installed in a completely sealed or mechanically ventilated house without extra ventilation and/or fume extraction.
The gas fire can be installed as an insertion into an existing open fire place or as a built-in appliance in a new fire place. The exception to this rule is the Smart Bell. This appliance can also be wall-mounted. Chimney ventilation and a convection package is then not required.
In order to prevent the fireplace heating up excessively, it must be properly ventilated by installing vents at the top and bottom of the fireplace..
The appliance can be fitted with a convection package as an optional extra. This is a ‘convection jacket’ for the appliance, two flexible aluminium pipes and two built-in convection vents. This enables hot air to be circulated into the room.
When handling the frame, we advise you to use the special gloves supplied, and to leave them with the owner of the hearth after installation.
If an existing chimney is to be used, please consult your installer first. If the chimney was previously used for a wood or coal fire, then it should be cleaned by an expert.
20
Bellfires
English
Instructions for use and installation instructions
3.2 BARBAS AND ONTOP CONCENTRIC FLUE Ø100 MM - Ø150 MM SYSTEM
The appliance is in combination with the concentric flue system [Ø100 mm – Ø150 mm] (either rigid or flexible) of Barbas or Ontop (US system) compliant with the European CE norm for gas appliances, and may therefore only be used with these systems. The guarantee is invalidated if the appliance is (completely or partially) installed using a different system. The Barbas and Ontop concentric flue [Ø100 mm - Ø150 mm] systems can be used with either a newly-built or existing chimney.
3.3 PREPARATION FOR INSTALLA TION
The following preparation must be carried out before the gas fire can be installed.
3.3.1 Instructions for positioning the outlet
3.3.1.1 Positioning the outlet for correct operation:
Roof-mounted outlet:
Figure 6: Roof-mounted outlet
This must be positioned at least 0.5 m from the roof edge; the apex of the roof can be disregarded.
Wall-mounted outlet:
Figure 7: Wall-mounted outlet
This must be positioned at least 0.5 m from:
the corner of the building.
the roof overhang, the rain gutter.
balconies etc., unless the exhaust construction
extends to at least the face of the protruding section.
>0,5 m
>0,5 m
21
Bellfires
English
Instructions for use and installation instructions
3.3.1.2. Positioning the outlet to avoid affecting the surrounding area
All listed “distances” in this section are no more than guidelines. For the exact minimum “distances”, please consult your national and local directives.
Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to:
A. A ventilation opening serving an occupied room, a toilet or a bathroom. B. A heating air supply, when the supply flows through an occupied room. C. A window that can be opened and that is near an occupied room, a toilet or
a bathroom.
Roof-mounted outlet:
To avoid adverse effects Distance: outlet - A, B or C
At the same roof level. >3 m (*)
At a different roof level. >1 m (*)
At a lower positioned wall. >1 m
At a higher sloping surface. >3 m (**)
(*) If the required distance cannot be achieved, the outlet position rules take
precedence.
(**) If the required distance cannot be achieved, the position of the outlet must
be at least 1 m above the highest facade/roof.
22
Bellfires
English
Instructions for use and installation instructions
Wall-mounted outlet:
To avoid adverse effects Distance: outlet - A, B or C
At walls in buildings with staggered Not permitted if A, B, or C are located heights. above the outlet.
On a wall - general. (*) Above the outlet: >2 m
Below the outlet: >0.75 m Left and right of the outlet: >0.75 m
At <1 m from the roof overhang. >2 m
Beneath balconies, walkways etc. >2 m tot onderzijde van een
uitstekend balkon of galerij.
Beneath balconies, walkways >2 m etc. where the outlet extends to the front.
To the garden or on the terrace. >2 m to the outside space. (**)
With respect to a facing wall. >2 m (if the distance from the facing
wall is less, the criteria detailed for “On a wall - general” apply.
Enquire at your local gas company for the regulations relating to outlets
positioned opposite each other and outlet(s) in facade(s) that form an angle.
(*) These minimum distances do not apply if there is an obstruction
between the outlet and A, B and C that protrudes at least 0.5 m from the wall and has a length exceeding the distance.
(**) This distance is not required if the outlet is situated at least 1 m
higher than the intended area of the outside space.
If the outlet has a clearance of less than 0.5 m from the hard surface of a public area at a height of less than 2 m, it must be fitted with an effective protector. The mesh size of the guard must not affect the correct operation of the appliance.
23
Bellfires
English
Instructions for use and installation instructions
3.4 GENERAL SERVICES
3.4.1 The Fume Channel/Combustion Air Intake
The combined fume channel and combustion air intake requires one of the following Barbas or Ontop concentric flue system configurations.
Important: Due to the high temperature of the outer walls
(approx. 150°C), no flammable materials may be located or used in the vicinity of the flue system. The complete flue system, must therefore be sleeved with a heat resistant material after assembly.
Ventilate the covered concentric flue by fitting a grid near the floor and ceiling (on each floor).
Do not insulate the concentric flue.
Use the universal wall/floor support Ø150 mm to attach the covering of the concentric flue system [Ø100 mm - Ø150 mm], see 3.4.2, drawing number 36.
Figure 8: Application universal wall/floor support Ø150 mm
36
36
Use as a wall support Use as a floor support
24
Bellfires
English
Instructions for use and installation instructions
19
Appliance: Distance X Distance Y
(min.-max.) (min.-max.)
All appliances,
0 - 0,6 m 0,5 - 1,0 m -
except…
0 - 3,0 m 1,0 - 3,0 m -
... Derby
Derby II
0 - 0,6 m 1,0 - 2,0 m -
Jersey
0 - 3,6 m 2,0 - 3,0 m -
Horizon Bell Medium
... Horizon Bell Small (tunnel) /
0 - 3,0 m 1,5 - 3,0 m -
Large (tunnel) / XL
... Vertical Bell Small
0 - 0,6 m 0,5 - 1,0 m ­0 - 3,0 m 1,0 - 3,0 m -
... Vertical Bell Tunnel
0 - 1,6 m 0,0 - 1,0 m ­0 - 3,0 m 1,0 - 3,0 m -
1
4
23
10, 11, 12, 13
23
X
Y
28
Wall Termination Position
Item descriptions:
see 3.4.2
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
0,16 m
Figure 9: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Assemble
restriction plate
25
Bellfires
English
Instructions for use and installation instructions
Figure 10: Vertical roof-mounted outlet without bend
Appliance: Distance Y
(min.-max.)
All appliances, except… 2,0 - 1 1,0 m ­... Jersey
... Vertical Bell Small
2,0 - 1 1,0 m Width: B = 30 mm
... Vertical Bell Tunnel ... Horizon Bell Medium
18
10, 11, 12, 13
1
4
Y
28
16
17
16
24
23
24
23
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 3.4.2
Assemble
restriction plate
26
Bellfires
English
Instructions for use and installation instructions
Figure 11: Vertical roof-mounted outlet with bend
Appliance: Distance X (*) Distance Y1 (*) Distance Y1 + Y2 (*)
(min.-max.) (min.-max.) (min.-max.)
All appliances 0 - 3,0 m 1,0 - 10,0 m 1,0 - 10,0 m -
16
23
Y
2
X
10, 11, 12, 13
14, 15
Y
1
4
1
28
23
23
17
24
(*) : (Y1 + Y2) : X > 2 : 1 (vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 3.4.2
Assemble
restriction plate
27
Bellfires
English
Instructions for use and installation instructions
Appliance: Distance Y
(min.-max.)
All appliances, except… 2,0 - 1 1,0 m ­... Jersey
... Vertical Bell Small
2,0 - 1 1,0 m Width: B = 30 mm
... Vertical Bell Tunnel ... Horizon Bell Medium
FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
Figure 12: Vertical chimney outlet using an existing lined chimney
(Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
1
4
28
32
18
23
25
26
29
7
5
29
30
10, 11, 12, 13
Y
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 3.4.2
Assemble
restriction plate
28
Bellfires
English
Instructions for use and installation instructions
Figure 13: Vertical chimney outlet using a lined chimney with a bend > 45°
(Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
(*) : (Y1 + Y2 + Y3) : X > 2 : 1 (vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
Y
2
Y
1
10, 11, 12, 13
> 45°
X
Y
3
32 18 30
29
5
7
29 26
25
23
28
4
1
Appliance: Distance X (*) Distance Y1 (*) Distance Y1 + Y2+ Y3 (*)
(min.-max.) (min.-max.) (min.-max.)
All appliances 0 - 3,0 m 1,0 - 10,0 m 1,0 - 10,0 m -
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 3.4.2
Assemble
restriction plate
29
Bellfires
English
Instructions for use and installation instructions
Figure 14: Vertical chimney outlet using an existing unsound lined
chimney or when no chimney liners are present
(Flexible Ø100 mm / Ø150 mm)
Appliance: Distance Y
(min.-max.)
All appliances, except… 2,0 - 1 1,0 m ­... Jersey
... Vertical Bell Small
2,0 - 1 1,0 m Width: B = 30 mm
... Vertical Bell Tunnel ... Horizon Bell Medium
Y
7
6 8
1832
31
29
30 29
26
29
27
28 29
4
1
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 3.4.2
Assemble
restriction plate
30
Bellfires
English
Instructions for use and installation instructions
Y
3
Y
2
Y
1
X
> 45°
6
8
7
31 29
32 18
30 29
26
29
27
28 29
4
1
Figure 15: Vertical chimney outlet using an existing unsound lined
chimney or when the chimney is unlined; with a bend >45
o
(Flexible Ø100 mm / Ø150 mm)
(*) : (Y1 + Y2 + Y3) : X > 2 : 1 (vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
Appliance: Distance X (*) Distance Y1 (*) Dist ance Y1 + Y2 + Y3 (*)
(min.-max.) (min.-max.) (min.-max.)
All appliances 0 - 3,0 m 1,0 - 10,0 m 1,0 - 10,0 m -
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 3.4.2
Assemble
restriction plate
31
Bellfires
English
Instructions for use and installation instructions
SMART - BELL
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
REAR CONNECTION
Figure 16: Horizontal wall termination
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
4
2
28
10, 12, 13
14, 15
23
19
X
1
Y
X
2
23
10, 11, 12, 13
Appliance: Distance X
1
Distance X
2
Y
(min.-max.) (min.-max.)
Smart Bell 0 - 0,5 m 0 - 0,6 m 1,0 - 3,0 m -
Item descriptions:
see 3.4.2
Wall
T ermination Position
Assemble
restriction plate
32
Bellfires
English
Instructions for use and installation instructions
SMART - BELL
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
Appliance: Distance X Distance Y
(min.-max.) (min.-max.)
Smart Bell 0 - 0,5 m 2,0 - 12,0 m -
REAR CONNECTION
2
4
28
10, 12, 13
14, 15
23
10, 11, 12, 13
17
16 18
23
24
24
16
X
Y
Figure 17: Vertical roof-mounted outlet without bend
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 3.4.2
Assemble
restriction plate
33
Bellfires
English
Instructions for use and installation instructions
(**) : ( Y1 + Y2 ) : ( X 1 + X 2 ) > 2 : 1 (vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1))
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Figure 18: Vertical roof-mounted outlet with bend
SMART - BELL
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
REAR CONNECTION
Appliance: Distance X1 (**) Distance X2 (**) Distance Y1 + Y2 (**)
(min.-max.) (min.-max.) (min.-max.)
Smart Bell 0 - 0,5 m 0 - 2,0 m 1,0 - 1 1,0 m -
16
17
24
23
10, 11, 12, 13
23
23
2
14, 15
4
28
14, 15
Y
2
Y
1
X
2
X
1
Item descriptions:
see 3.4.2
Assemble
restriction plate
34
Bellfires
English
Instructions for use and installation instructions
Figure 19: Vertical chimney outlet using an existing unsound lined
chimney or when no chimney liners are present
(Flexible Ø100 mm - Ø150 mm and/or rigid Ø100 mm - Ø150 mm)
32
31
29
29
30
18
4
2
28
10, 12, 13
14, 15
6 8
7
26
29
29
28
27
Y
X
SMART - BELL
FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
REAR CONNECTION
Appliance: Distance X Distance Y
(min.-max.) (min.-max.)
Smart Bell 0 - 0,5 m 2,0 - 12,0 m -
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Item descriptions:
see 3.4.2
Assemble
restriction plate
35
Bellfires
English
Instructions for use and installation instructions
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
SMART - BELL
FLEXIBLE CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES
REAR CONNECTION
(**) : (Y1 + Y2 + Y3) : (X 1 + X 2) > 2 : 1 (vertical to horizontal ratio (or 45° upwards) is always at least 2 to 1)
Figure 20: Vertical chimney outlet using an existing unsound lined
chimney or when the chimney is unlined; with a bend >45
o
(Flexible Ø100 mm - Ø150 mm and/or rigid Ø100 mm - Ø150 mm)
2
4
28
5 7
32 30
29
18
> 45°
Y
1
X
1
Y
2
Y
3
X
2
Appliance: Distance X1 (**) Distance X2 (**) Distance Y1+Y2+Y3 (**)
(min.-max.) (min.-max.) (min.-max.)
Smart Bell 0 - 0,5 m 0 - 2,0 m 1,0 - 11,0 m -
Item descriptions:
see 3.4.2
Assemble
restriction plate
36
Bellfires
English
Instructions for use and installation instructions
SMART - BELL
RIGID CONCENTRIC FLUE Ø100 mm - Ø150 mm SYSTEM CONNECTION POSSIBILITIES AND “SNORKEL”
REAR CONNECTION
ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION
Figure 21: Horizontal wall outlet “Snorkel”
Appliance: Distance X
(min.-max.)
Smart Bell 0 - 0,5 m -
X
37
2
Item descriptions:
see 3.4.2
Assemble
restriction plate
37
Bellfires
English
Instructions for use and installation instructions
FIG. NO. DESCRIPTION
1 Gas fire 2 Wall-mounted gas fire; Smart Bell 3 ­4 Restriction plate; Jersey, Vertical Bell Small, Vertical Bell T unnel, Horizon Bell Medium 5 Chimney, min. Ø150 mm internal, totally gas tight 6 Chimney or fireproof sleeving. Min. Ø160 mm internal 7 Ø100 mm internal flexible stainless steel gas vent chimney liner AISI 316TI 8 Ø150 mm internal flexible stainless steel gas vent chimney liner AISI 316TI 9 -
FIG. NO.
10 11 12
13
14 15 16
17
18 19
20 21 22 23 24
DESCRIPTION
Twin-wall balanced flue pipe, l=500 mm, incl. , and Twin-wall balanced flue pipe, l=1000 mm, incl. , and Telescopic twin-wall balanced flue pipe, length =
min. 325 mm / max. 440 mm, incl. , and Adjustable length twin-wall balanced flue pipe,
length = 500 mm, incl. , and Twin-wall balanced flue elbow
90o, incl. , and
Twin-wall balanced flue elbow
45o, incl. , and
Vertical (roof) termination kit, length = 1360 mm (vertical), incl. , and
Adjustable roof flashing. Roof pitch 20o-45o (**), with lead flashing
Roof flashing for existing chimney or flat roof. Horizontal (wall) termination kit, l=600 mm (horizontally
adjustable)), incl. , and one set of wall spacer plates
: Stainless steel locking band Ø150 mm, quick-fastening : Silicone seal Ø150 mm : Silicone ring, red, Ø100 mm : Wall strap
Set of ceiling finishing plates / fire stops
ART. /
ORDER
NO.
302289 302290 302291
302292
302297 302298 302295
302212
302213 302296
302293 302210 302294 302215 302214
Color(*)
Application
RVS antr RIGID FLEX
l
l
l
l
l
l
l
l
l
l
l
l
l
AVAILABLE COMPONENTS FOR THE BARBAS CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm
3.4.2 Item descriptions for figures 9 t/m 21.
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
38
Bellfires
English
Instructions for use and installation instructions
FIG. NO.
25
26
27
28
29
30 31 32
33 34
35 36 37
DESCRIPTION
Ceiling plate for transition Ø100 mm / Ø150 mm rigid ­Ø100 mm (flex.).
Stainless steel adapter piece (100) from fire to flexible, Ø100 mm external (rigid) x Ø107 mm internal (flex.). [appliance ­Ø100 mm flex.] and [Ø100 mm rigid - Ø100 mm flex.].
Stainless steel adapter piece (150) fire to flexible, Ø148 mm external (rigid) x Ø148 mm internal (flex.) [appliance - Ø150 mm flex.].
Stainless steel locking band Ø150 mm. For adapter 150 [appliance - Ø150 mm flex.] Screw-fastening
Stainless steel screws Ø3.5 mm x Ø9.5 mm. For securing the flexible concentric flue. (Minimum 3 screws per connection)
Hose clamp Ø100 mm. (Minimum 2 per connection) Hose clamp Ø150 mm. (Minimum 2 per connection) Vertical (roof) termination kit, L = 610 mm (vertical), incl.
and . For the flexible flue system. Concentric T -piece with gauging orifice, incl. , and Concentric pipe with gauging orifice, L=165 mm, incl. ,
and 90° concentric bend with inspection panel incl. , and Universal wall / floor support Ø150 mm “Snorkel” wall outlet set for Smart Bell
ART. /
ORDER
NO.
302189
302278
302279
302217
303776
304041 304042 302307
302301 302302
302303 310192 319862
Color(*)
Application
RVS antr RIGID FLEX
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
If the appliance has been ordered with the BARBAS concentric flue/chimney system, a concentric Bellfires adapter will be supplied free of charge.
(*) : Color: RVS: Stainless steel self-colour, polished
antr.: Anthracite colour lacquer, matt
(**) : Adjustable roof flashing for a slope > 45° can be supplied on request. When installing a balanced-flue “closed” gas fire in an existing chimney, ensure
stainless steel flexible liners conforming with BS 316 are used to conduct the spent gases.
The room-sealed gas appliances have been approved in combination with the BARBAS or ONTOP (RIGID and FLEXIBLE) CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm according to the European CE norm for gas appliances and may therefore be used only in combination with this flue system.
39
Bellfires
English
Instructions for use and installation instructions
3.4.3 Gas connection
Operation (gas regulating block (and receiver)) within the appliance: The gas connection Ø12 mm (3/8”) is located on the right-hand side of the appliance.
Operation (gas regulating block (and receiver)) outside the appliance (in the operating unit):
The gas connection is situated where the operating unit is built in near to the appliance.
Use only gas piping with a minimum diameter of 1/2” and a shut-off valve.
3.4.4 Operating unit
If the appliance is fitted with a operating unit comprising gas control block and receiver, this will be located, once it has been built in, at a maximum of 50 cm from the left or right hand side of the appliance.
3.4.5 Convection package connections
When fitting a convection package, consideration should be given to the openings at approximately 1 meter above the appliance for the warm air exiting grids. If a convection package is to be fitted, the metal “insulation” shield at the top of the appliance, must also be removed.
3.5 POSITIONING THE APPLIANCE Important: The fire and fireplace must be mounted on a concrete floor.
If there is no concrete floor, it is essential to re­enforce the floor boards from beneath with concrete.
Never place the appliance directly on the floor, but always make sure that there is a clearence of at least 5 cm between the appliance and the floor.
Min. 5 cm
Min. 5 cm
Figure 22: A clearence of at least 5 cm must be maintained between the
appliance and the floor.
40
Bellfires
English
Instructions for use and installation instructions
Never use combustible materials during the installation.
Ventilate the fireplace, by allowing vents above and below the fireplace.
During installation of the gas fire, a clearance of 3 mm should be maintained on all sides of the appliance to allow for expansion of the appliance during operation.
Do not insulate the appliance! Only the top and sides may be fitted with a strip of white, loose insulation wool (heat-resistant to 1000°C), width 15 cm max. to protect the wall.
Do not use fibreglass or Rockwool, or any other sort of insulating material. These emit a pungent odour. This is considered extremely unpleasant. They may also cause discolouring of the column.
Flammable materials, such as curtains, should not be placed in the vicinity of the gas fire. Minimum safe distance: 100 cm
If desired, fit a convection package to the appliance. (See chapter 3.1)
Figure 23: Use of convection package and ventilation of fireplace
41
Bellfires
English
Instructions for use and installation instructions
When fitting the appliance, it can be levelled with the adjustable feet. Position the gas supply pipe such that it can be easily mounted after installation.
If the appliance has a operating unit, the gas pipe must lead to where the operating unit (built in), the gas regulating block (and the receiver) assembly are fitted.
The appliance must not make contact with a flammable rear wall.
3.5.1 Connecting the gas Important: During gas connection, take care not to twist the gas
regulating block. Make sure that both the gas regulating block and the supply pipes are not subjected to stresses.
Appliance with operation in the separate operating unit (built in or otherwise):
• The control unit and piping are supplied separately (flat packed) Remove the decorative edging and door of the operating unit. Fit the separate
operating unit with the gas control block and receiver max. 50 cm from the appliance.
Figure 24: Operating unit
Connect the supplied Ø8 mm copper gas pipe to the underside of the burner plate on the fire using the compression coupling.
ATTENTION !!! BLOW THE INSIDE OF THE COPPER PIPE WELL CLEAN AFTER BENDING
The connections for the main burner (Ø8 mm copper), pilot light (Ø4 mm copper or aluminium), thermocouple (thermocouple interrupter) and piezo cable can now be made at the gas regulating block in the operating unit. If the system has remote control, the piezo cable must be connected to the receiver (see figure 25).
Operating unit
Frame with door (white)
42
Bellfires
English
Instructions for use and installation instructions
Important: Using the hand, screw the thermocouple connection (and
thermocouple interrupter) into the back of the gas regulating unit. Carefully tighten another half of a turn using a number 9 fork spanner. See figure 25, 26 and Chapter 6.
Remote control Gas regulating block and receiver in operating unit
Figure 25: Remote control: Gas regulating block and receiver in operating unit
1 Gas regulating block 2 Gas supply connection 3/8” - Ø12 / Ø15 mm insertion 3 Burner piping connection Ø8 mm insertion 4 Thermocouple connection M 9x1 mm insertion 5 Pilot light piping connection Ø4 mm insertion 6 Receiver 7 Piezo cable connection
43
Bellfires
English
Instructions for use and installation instructions
Remote control The photo below shows how the piping for a remote control gas regulating block must
be fitted.
Figure 26: Gas regulating block Remote control
(Tab 2,8 x 0,8 mm) Connection piezo cable (Hand Control)
Side-inlet
Inlet Pressure Tap
Thermo Unit Connection Minimum Rate Adjustment Screw
Motor-Knob
Operating-Knob
Pilot Gas Adjustment (with Screwdriver)
Maximum Rate Adjustment Screw
Side-outlet
Outlet Pressure Tap
Bottom Outlet
Bottom Inlet
44
Bellfires
English
Instructions for use and installation instructions
Figure 27: Gas regulating block Remote control
Hand control Gas regulating block in operating unit
The photo below shows how the piping for a hand control gas regulating block must be fitted
Microswitch
Motor-Knob
Operating-Knob
(Remote control Hand control)
Connection
Piezo Igniter
(Hand control)
Piezo Igniter
(Hand control)
O I” Switch
8-Wire Receiver Jack
Connection
Pilot Gas
45
Bellfires
English
Instructions for use and installation instructions
General: Route all piping and cables from the operating unit to the appliance through an easily
accessible hollow cavity or a heat-resistant pipe of minimum Ø50 mm. During subsequent installation of the operating unit, protect the gas regulating block
and piping against encasement by cement etc.
Important: Cement and chalk can damage the piping
and can, in turn, lead to gas leaks.
3.5.2 Connecting the concentric flue
The concentric flue system can now be connected to the appliance. Make sure that all connections are completely gas tight.
3.5.3 Building in the appliance
Remove the front of the casing.
Decide on positions of the vents (grilles above and below the fireplace) and, if
applicable, the hot air grids of the convection package. The brickwork must be built up around the hearth. In connection with the hearth
expanding during burning: there must be at least 3 mm clearance on either side of the appliance. Do not build up the brickwork farther than the angle irons/brackets (keep in mind the thickness of any plastering!).
Appliance with operation in the separate operating unit (built in or otherwise):
• Gas control block and piping supplied as an pre-assembly. First detach the bracket with the gas control block from the appliance.
Fit the separate control unit max. 50 cm from the appliance. Fit the receiver in the top of the control unit. Connect the piezo cable and the 8-terminal cable to the receiver.
Carefully move the bracket with the gas regulating block and piping towards the control unit. Fit the bracket to the bottom of the control unit. Make sure that you do not damage any of the piping or detach any compression couplings while doing this. After you have done this, check the compression couplings for leaks.
46
Bellfires
English
Instructions for use and installation instructions
Connect up the convection package, if applicable.
The optional mantle iron is intended for supporting the brickwork above the hearth. The mantle iron must rest on the brickwork on both sides so that upward building is possible. The brickwork therefore must not rest on the fireplace; there must be approx. 2 cm clearance in connection with the weight.
If using other materials, such as stone or heat-resistant plating, you should follow the supplier’s instructions.
Once the fireplace has been finished, you can now, for appliances with an operating unit, fit the frame with the small door to the operating unit.
After installation in a new fireplace and/or applying new cement work, the appliance cannot be used for at least four weeks.
3.5.4 Checking the gas connection
After connection of the gas supply, check that all connections are completely gas tight using soapy water or a leak tester.
3.5.5 Positioning the ceramic log set, marble pebbles and ceramic stones
The appliance can be supplied with:
• Ceramic log set + embers
• Ceramic stones
• Marble pebbles
Important: • Do not place any embers, logs, marble pebbles or stones
against the pilot light burner. For that reason, the main burner has a protective pilot-light cowl. Never remove this cowl! Make sure that the pilot flame can burn at all times freely over the main burner. Only in this way is proper ignition of the main burner ensured. Ignoring these directions could lead to a dangerous situation.
• The burner bed (with embers) and the positioning of the logs, marble pebbles or stones must not be changed.
• Only use those items supplied! Thesebeen rigorously checked and the quantities adapted to the appliance.
• Replacement parts, including the ceramic mat are available from your dealer.
• Fitting may only be carried out by a qualified person.
47
Bellfires
English
Instructions for use and installation instructions
3.5.5.1 Ceramic log set + embers
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Remove the embers (2x 100 gram) carefully from their packaging and spread them
evenly over the burner mat and the grate around the burner.
Note ! : Small embers and their residue should not be scattered on
the burner. This can cause a blockage on the burner orifices.
Embers must not be placed next to the pilot light burner.
Ensure that the rear logs are approximately 3 cm from the rear
If the burner runs on propane, make sure that all burner openings remain free!!!
The positioning of ceramic log set varies per model. Position the log set in one of the groupings shown below.
48
Bellfires
English
Instructions for use and installation instructions
Group B:
Retro Bell Large, Retro Bell Intermediate, Flat Bell
Group C:
Derby, Derby II, Horizon Bell Large, Horizon Bell Small, Horizon Bell Large Tunnel, Corner Bell Large
Group A: York, Topsham (incl. Sandur), Kent, Corner Bell Small, Vertical Bell Large, View Bell (incl. Sandur Panorama), Retro Bell Small, Retro Bell Solo
Embers must not be placed next to the pilot light burner
Embers must not be placed next to the pilot light burner
Embers must not be placed next to the pilot light burner
49
Bellfires
English
Instructions for use and installation instructions
Group D:
Horizon Bell Extra Large
Embers must not be placed next to the pilot light burner
50
Bellfires
English
Instructions for use and installation instructions
Group F:
Horizon Bell Small Tunnel
• Position the logs as shown below.
Group E:
Topsham Tunnel
Position the logs as shown below. The photos show the situation from either side.
Embers must not be placed next to the pilot light burner
Embers must not be placed next to the pilot light burner
51
Bellfires
English
Instructions for use and installation instructions
Group G (a):
Jersey: Natural gas
Group G (b):
Jersey: Propane
Embers must not be placed next to the pilot light burner
Embers must not be placed next to the pilot light burner
Keep the burner orifices unblocked
52
Bellfires
English
Instructions for use and installation instructions
Group H (a):
Vertical Bell Small: Natural gas
Embers must not be placed next to the pilot light burner
53
Bellfires
English
Instructions for use and installation instructions
Group H (b):
Vertical Bell Small: Propane
Embers must not be placed next to the pilot light burner
Keep the burner orifices unblocked
54
Bellfires
English
Instructions for use and installation instructions
Group I:
Vertical Bell Tunnel
Embers must not be placed next to the pilot light burner
55
Bellfires
English
Instructions for use and installation instructions
Group J:
Smart Bell
Logs must not be placed next to the pilot light burner
56
Bellfires
English
Instructions for use and installation instructions
Group K (a):
Horizon Bell Medium: Natural gas
Embers must not be placed next to the pilot light burner
57
Bellfires
English
Instructions for use and installation instructions
Group K (b):
Horizon Bell Medium: Propane
Keep the burner orifices unblocked
Embers must not be placed next to the pilot light burner
58
Bellfires
English
Instructions for use and installation instructions
Group A: Jersey
3.5.5.2 Ceramic stones
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Spread out the stones evenly on the bed of the burner. Do not block the burner
openings! See separate notes for how to arrange the stones for the Jersey, Vertical Bell Small, Vertical Bell Tunnel and Horizon Bell Medium. Make sure that the pilot light remains free at all times.
Figure 28: Positioning stones
Stones must not be placed next to the pilot light burner
Stones must not be placed next to the pilot light burner
59
Bellfires
English
Instructions for use and installation instructions
Group B (a): Vertical Bell Small: Natural gas
Stones must not be placed next to the pilot light burner
60
Bellfires
English
Instructions for use and installation instructions
Group B (b): Vertical Bell Small: Propane
Stones must not be placed next to the pilot light burner
61
Bellfires
English
Instructions for use and installation instructions
Group C (a): Vertical Bell Tunnel: Natural gas
Group C (b): Vertical Bell Tunnel: Propane
Stones must not be placed next to the pilot light burner
Stones must not be placed next to the pilot light burner
62
Bellfires
English
Instructions for use and installation instructions
Group D (a):
Horizon Bell Medium: Natural gas
Stones must not be placed next to the pilot light burner
63
Bellfires
English
Instructions for use and installation instructions
Group D (b):
Horizon Bell Medium: Propane
Stones must not be placed next to the pilot light burner
64
Bellfires
English
Instructions for use and installation instructions
3.5.5.3 Marble pebbles
1 Place the ceramic mat on the burner in such a way that the holes in the mat are in
line with the burner openings.
2 Spread the pebbles over the whole burner bed (burner and grid around the burner).
Make sure that the pilot light remains free.
Figure 29: Marble pebbles-set NATURAL GAS
IMPORTANT: Open area, in order to ensure free
accessibility of the pilot flame to the burner.
Figure 30: Marble pebbles-set PROPANE
IMPORTANT: Open area, in order to ensure free
accessibility of the pilot flame to the burner.
Keep the burner orifices unblocked
65
Bellfires
English
Instructions for use and installation instructions
Important:
ll
ll
l Do not place any marble pebbles in front of the pilot light.
Make sure that the pilot light can burn freely over the main burner.
ll
ll
l Keep the burner orifices unblocked
Only this way a proper ignition of the main burner is ensured.
Once the logs/stones/marble pebbles have been positioned, the door must be closed again or the glass must be replaced. FINGER-TIGHTEN any bolts and/or screws used. Do not over-tighten them as this may break the glass!
The frame can now be replaced. Note: Do not fit the frame until the wall has been
finished. Use the protective items supplied (gloves or cloth). Do not use masking tape!
3.5.6 Mounting flue gas restriction plate
Depending on the length and shape of the concentric flue system and the chimney construction, you should, if indicated, fit a restriction plate with a certain width (B), or with a certain diameter (D) into the ceiling of the combustion chamber. To do this, see the set-up options as listed in figure 9 through 21.
Important: Ensure that the correct flue gas restriction plate is mounted.
Use of the correct flue gas restriction plate will provide optimum efficiency, flame effect and combustion. Mounting an incorrect flue gas restriction plate can result in damage to the gas fire.
Figure 31: Positioning restriction plate
Assembly restriction plate
66
Bellfires
English
Instructions for use and installation instructions
The following restriction plate is supplied:
l Jersey l Vertical Bell Small l Vertical Bell Tunnel l Horizon Bell Medium
3.5.7 Checking the appliance following installation
After installation, visually check the gas flame. When the fire is ignited, the flames should be short and blue/yellow in colour. These flames should gradually increase in height and become more yellow. When all flames are yellow, the gas fire has reached the correct temperature.
THE GAS FIRE IS NOW READY FOR USE
Restriction plate: Width: B = 30 mm
67
Bellfires
English
Instructions for use and installation instructions
4 MAINTENANCE
4.1 ANNUAL MAINTENANCE
It is essential that the appliance, the complete concentric flue system and the outlet are cleaned and inspected annually by a recognised fitter/gas specialist. The safe operation of the appliance will thus remain guaranteed.
Maintenance consists of the following:
l Remove first the embers and/or vermiculite granules, set of logs and/or pebbles from
the main burner and carefully clean these with a soft brush.
l Clean and inspect (visually) the main burner, pilot light, combustion chamber,
flue system and combustion air intake. Dust can be removed using a vacuum cleaner.
l After cleaning;
Carefully replace the embers and/or vermiculite granules, set of logs and/or pebbles on and around the main burner according to the installation directions in this instruction booklet.
Do not place any embers, vermiculite granules, logs or pebbles against the pilot light burner. Make sure that the pilot flame can burn at all times freely over the main burner. Only in this way is proper ignition of the main burner ensured. Ignoring these directions could lead to a dangerous situation.
l Check the gas supply, flue system, and combustion air supply route for leaks. l Check the correct operation of the gas regulating block, thermocouple
circuit and the ignition of the main burner.
l Check the gas inlet-pressure (both when the appliance is off and when it burns
at maximum) and the burner pressure.
l Check the complete concentric flue system including the outlet construction. l Check the operation of the thermostatically controlled convection fans.
(If present.)
68
Bellfires
English
Instructions for use and installation instructions
5 FAULTS
Possible reasons for the gas fire going out are:
l The concentric flue system is not installed according to one of the methods detailed
in Paragraph 3.4
l An incorrect “flue gas restriction plate” is fitted. l The pilot light extinguishes if fumes are not exhausted or are insufficiently
exhausted.
l The pilot light is either dirty or defective. l Insufficient gas pressure. l Thermocouple voltage is too low. This is usually caused by insufficient heating of the
thermocouple by the pilot light.
l Dirty electrical contacts in the thermo-electrical system; for example, the
thermocouple connection.
69
Bellfires
English
Instructions for use and installation instructions
6 ELECTRICAL DIAGRAM
6.1 MODELS WITH REMOTE CONTROL
Thermo­ couple
Ignition cable
Antenna
Button “Reset”
Motor­knob
Operating-Knob
O I” Switch
Gas regulating block
RECEIVER
Battery
Compartment
panel
4 AA Batteries
cable 2
cable 1
“red”
“black”
SPARK
SPARK
SW TC
SW TC
GR
SW
MA
MO
Pilot
ON/OFF Switch
Thermocurrent interrupter Block
“red”
“yellow”
Thermo ­current Interrupter Block
8 Wire Connecting Cable
70
Bellfires
English
Instructions for use and installation instructions
7.1 DERBY / DERBY II (**)
7 DIMENSIONS
(*) Available with control unit in appliance (bottom) or in separate operating unit, see page 82 (**) Control unit in separate operating unit, see page 82 (***) Control unit in appliance (bottom)
7.2 JERSEY (**)
71
Bellfires
English
Instructions for use and installation instructions
7.3 FLAT BELL (*)
7.4 TOPSHAM (*)
72
Bellfires
English
Instructions for use and installation instructions
7.6 YORK (*)
7.5 TOPSHAM TUNNEL (*)
73
Bellfires
English
Instructions for use and installation instructions
7.7 KENT (*)
7.8 RETRO BELL LARGE (***)
74
Bellfires
English
Instructions for use and installation instructions
7.10 RETRO BELL SMALL (***)
7.9 RETRO BELL INTERMEDIATE (***)
75
Bellfires
English
Instructions for use and installation instructions
7.11 RETRO BELL SOLO (***)
7.12 VIEW BELL (**)
76
Bellfires
English
Instructions for use and installation instructions
7.14 CORNER BELL SMALL (**)
7.13 CORNER BELL LARGE (**)
77
Bellfires
English
Instructions for use and installation instructions
7.15 HORIZON BELL EXTRA LARGE (**)
7.16 HORIZON BELL LARGE (**)
78
Bellfires
English
Instructions for use and installation instructions
7.18 HORIZON BELL MEDIUM (**)
7.17 HORIZON BELL LARGE TUNNEL (**)
79
Bellfires
English
Instructions for use and installation instructions
7.19 HORIZON BELL SMALL (**)
7.20 HORIZON BELL SMALL TUNNEL (**)
80
Bellfires
English
Instructions for use and installation instructions
7.22 VERTICAL BELL LARGE TUNNEL (**)
7.21 VERTICAL BELL LARGE (**)
81
Bellfires
English
Instructions for use and installation instructions
7.23 VERTICAL BELL SMALL (**)
7.24 SMART BELL (***)
82
Bellfires
English
Instructions for use and installation instructions
OPERATING UNIT
83
Bellfires
English
Instructions for use and installation instructions
8 TECHNICAL DET AILS/REGULA TIONS
National installation regulations: Gas safety installation and use regulations 1984 plus all relevant safety and building regulations concerning fire installation
Model : DERBY
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 12.5 kW : 9.5 kW
Nominal heat output : 8.4 kW : 6.4 kW Efficiency class : 2 (75%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 1.19 m
3
s
/hr. : 690 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 13.0 mbar(*) : 29.2 mbar Burner pressure (max.) Cold : 1 1.9 mbar(**) : 29.2 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø15.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 1200 : no 18 / 280
(= 7x Ø1.262 mm) (= 7x Ø0.612 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
84
Bellfires
English
Instructions for use and installation instructions
Model : DERBY II
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 11.5 kW : 9.5 kW
Nominal heat output : 7.8 kW : 6.4 kW Efficiency class : 2 (75%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 1.10 m
3
s
/hr. : 690 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 13.0 mbar(*) : 29.2 mbar Burner pressure (max.) Cold : 1 1.9 mbar(**) : 29.2 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø18.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 1200 : no 18 / 280
(= 7x Ø1.262 mm) (= 7x Ø0.612 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
85
Bellfires
English
Instructions for use and installation instructions
Model : JERSEY
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 9.5 kW : 6.8 kW
Nominal heat output : 6.8 kW : 4.6 kW Efficiency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.91 m
3
s
/hr. : 510 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 18.1 mbar(*) : 29.7 mbar Burner pressure (max.) Cold : 17.1 mbar(**) : 29.7 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 700 : no 18 / 220
(= 7x Ø0.984 mm) (= 7x Ø0.549 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
86
Bellfires
English
Instructions for use and installation instructions
Model : YORK
TOPSHAM KENT VIEW BELL TOPSHAM TUNNEL SANDUR SANDUR P ANORAMA
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 8.3 kW : 8.5 kW
Nominal heat output : 6.0 kW : 5.7 kW Efficiency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.79 m
3
s
/hr. : 640 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Operation Burner pressure (max.) : 16.0 mbar (*) : 29.4 mbar
in Hot appliance
Burner pressure (max.) : 15.0 mbar (**) : 29.4 mbar Cold
Operation Burner pressure (max.) : 17.0 mbar (*) : 29.4 mbar in external Hot operating unit Burner pressure (max.) : 16.0 mbar (**) : 29.4 mbar
Cold Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 560 : no 18 / 260
(= 7x Ø0.891 mm) (= 7x Ø0.592 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
87
Bellfires
English
Instructions for use and installation instructions
Model : FLAT BELL
RETRO BELL LARGE RETRO BELL INTERMEDIATE
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 10.0 kW : 9.5 kW
Nominal heat output : 6.8 kW : 6.4 kW Efficiency class : 2 (75%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.95 m
3
s
/hr. : 720 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Operation Burner pressure (max.) : 6.0 mbar (*) : 29.2 mbar
in Hot appliance
Burner pressure (max.) : 5.0 mbar (**) : 29.2 mbar Cold
Operation Burner pressure (max.) : 9.0 mbar (*) : 29.2 mbar in external Hot operating unit Burner pressure (max.) : 8.0 mbar (**) : 29.2 mbar
Cold Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 1200 : no 18 / 280
(= 7x Ø1.262 mm) (= 7x Ø0.612 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
88
Bellfires
English
Instructions for use and installation instructions
Model : RETRO BELL SMALL
RETRO BELL SOLO
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 8.0 kW : 7.5 kW
Nominal heat output : 5.8 kW : 5.1 kW Efficiency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.76 m
3
s
/hr. : 570 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 17.0 mbar(*) : 29.2 mbar Burner pressure (max.) Cold : 16.2 mbar(**) : 29.2 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø15.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 560 : no 18 / 220
(= 7x Ø0.891 mm) (= 7x Ø0.549 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
89
Bellfires
English
Instructions for use and installation instructions
Model : CORNER BELL SMALL
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 8.3 kW : 8.5 kW
Nominal heat output : 6.0 kW : 5.7 kW Efficiency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.79 m
3
s
/hr. : 640 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 17.0 mbar(*) : 29.2 mbar Burner pressure (max.) Cold : 16.0 mbar(**) : 29.2 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 560 : no 18 / 260
(= 7x Ø0.891 mm) (= 7x Ø0.592 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
90
Bellfires
English
Instructions for use and installation instructions
Model : HORIZON BELL EXTRA LARGE
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 14.0 kW : 12.0 kW
Nominal heat output : 9.8 kW : 8.2 kW Efficiency class : 2 (78%) : 2 (76%) NOx-class : 5 : 5
Gas rate (max.) : 1.33 m
3
s
/hr. : 910 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 15.0 mbar(*) : 29.0 mbar Burner pressure (max.) Cold : 14.3 mbar(**) : 29.0 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 1200 : no 18 / 380
(= 7x Ø1.262 mm) (= 7x Ø0.705 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
91
Bellfires
English
Instructions for use and installation instructions
Model : HORIZON BELL LARGE
HORIZON BELL LARGE TUNNEL CORNER BELL LARGE
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 11.5 kW : 10.5 kW
Nominal heat output : 8.3 kW : 7.3 kW Efficiency class : 2 (80%) : 2 (77%) NOx-class : 5 : 5
Gas rate (max.) : 1.10 m
3
s
/hr. : 790 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 10.6 mbar(*) : 29.1 mbar Burner pressure (max.) Cold : 9.6 mbar(**) : 29.1 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 1200 : no 18 / 320
(= 7x Ø1.262 mm) (= 7x Ø0.651 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
92
Bellfires
English
Instructions for use and installation instructions
Model : HORIZON BELL MEDIUM
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3+ Butane/Propane G30/G31 Nominal heat input (Gross calorific value) : 10.5 kW : 8.0 kW
Nominal heat output : 7.5 kW : 5.6 kW Efficiency class : 2 (80%) : 2 (78%) NOx-class : 5 : 5
Gas rate (max.) : 1.00 m
3
s
/hr. : 560 gr/hr.
Supply pressure : 20.0 mbar : G30: 28.0 mbar
G31: 37.0 mbar Burner pressure (max.) Hot : 1 1.8 mbar(*) : 28.5 mbar Burner pressure (max.) Cold : 10.9 mbar(**) : 28.5 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø20.0 mm : 2x Ø20.0 mm Main burner injector : no 18 / 1200 : no 18 / 220
(= 7x Ø1.262 mm) (= 7x Ø0.549 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
93
Bellfires
English
Instructions for use and installation instructions
Model : HORIZON BELL SMALL
HORIZON BELL SMALL TUNNEL
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 9.5 kW : 9.5 kW
Nominal heat output : 6.8 kW : 6.4 kW Efficiency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.90 m
3
s
/hr. : 720 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 16.8 mbar(*) : 29.3 mbar Burner pressure (max.) Cold : 15.9 mbar(**) : 29.3 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 650 : no 18 / 280
(= 7x Ø0.951 mm) (= 7x Ø0.612 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
94
Bellfires
English
Instructions for use and installation instructions
Model : VERTICAL BELL LARGE
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 10.0 kW : 9.5 kW
Nominal heat output : 6.7 kW : 6.3 kW Efficiency class : 2 (74%) : 2 (74%) NOx-class : 5 : 5
Gas rate (max.) : 0.95 m
3
s
/hr. : 720 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 18.0 mbar(*) : 29.3 mbar Burner pressure (max.) Cold : 17.0 mbar(**) : 29.3 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 700 : no 18 / 280
(= 7x Ø0.984 mm) (= 7x Ø0.612 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
95
Bellfires
English
Instructions for use and installation instructions
Model : VERTICAL BELL LARGE TUNNEL
VERTICAL BELL SMALL
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 9.5 kW : 6.8 kW
Nominal heat output : 6.8 kW : 4.6 kW Efficiency class : 2 (80%) : 2 (75%) NOx-class : 5 : 5
Gas rate (max.) : 0.91 m
3
s
/hr. : 510 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 17.0 mbar(*) : 29.5 mbar Burner pressure (max.) Cold : 16.0 mbar(**) : 29.5 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : 1x Ø12.0 mm : 2x Ø25.0 mm Main burner injector : no 18 / 700 : no 18 / 220
(= 7x Ø0.984 mm) (= 7x Ø0.549 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
96
Bellfires
English
Instructions for use and installation instructions
Model : SMART BELL
Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identification no : 0063BL5625 : 0063BL5625
Type of appliance under CE-norm : C11 / C
31
: C11 / C
31
Category of appliance : I2H Natural gas G20 : I3P Propane G31 Nominal heat input (Gross calorific value) : 6.5 kW : 4.5 kW
Nominal heat output : 4.7 kW : 3.2 kW Efficiency class : 2 (80%) : 2 (80%) NOx-class : 5 : 5
Gas rate (max.) : 0.62 m
3
s
/hr. : 340 gr/hr. Supply pressure : 20.0 mbar : 37.0 mbar Burner pressure (max.) Hot : 16.3 mbar(*) : 29.4 mbar Burner pressure (max.) Cold : 15.3 mbar(**) : 29.4 mbar Burner pressure (min.) : 2.0 mbar : 5.0 mbar Gas regulator block (hand control) : BM 733-234484 : BM 733-234484
Gas regulator block (remote control) : Mertik GV 34 / GV 60 : Mertik GV 34 / GV 60 Main burner : IGP : IGP
Primary air inlet main burner : ê min. (= 3 mm) : ê max. (= 14 mm) Main burner injector : no 18 / 400 : no 18 / 140
(= 7x Ø0.723 mm) (= 7x Ø0.452 mm) Pilot light burner : SIT 0.145.019 : SIT 0.145.019 Pilot light burner injector : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150) Gas connection : 3/8" G / Ø12 mm : 3/8" G / Ø12 mm Concentric flue system : Ø100 mm - Ø150 mm : Ø100 mm - Ø150 mm
Batteries remote control
- Receiver : 4x 1.5V AA : 4x 1.5V AA
- Hand-transmitter : 1x 9V block : 1x 9V block (*) : When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold. Flue gas exhaust and combustion air supply:
BARBAS or ONTOP concentric flue system Ø100 mm-Ø150 mm. Rigid and/or flexible. Heat changing surface: Entire front of the appliance.
97
Bellfires
English
Instructions for use and installation instructions
9 REPLACEMENT PARTS LIST
When requesting service or ordering replacement parts, please quote the model type and serial number. All parts listed in this manual may be ordered from a Bellfires dealer.
No. Article no. Description
1 310995 Gas regulator block, BM 733 - 234484 (M9 Thermocouple connection) 2 301983 Nut Ø4 mm BM for pilot light pipe 3 301989 Olive Ø4 mm BM for pilot light pipe 4 301985 Nut Ø8 mm BM for burner pipe 5 301984 Olive Ø8 mm BM for burner pipe
6 310984 Gas regulator block and remote control set; GV 60 (M9 Thermocouple connection) 7 302083 Plug 3/8 GV 34 / GV 60 8 302084 Nut Ø8 mm for burner supply GV 34 / GV 60 9 302089 Olive Ø8 mm for burner supply GV 34 / GV 60 10 302085 Nut Ø12 mm for gas supply GV 34 / GV 60 11 302090 Olive Ø12 mm for gas supply GV 34 / GV 60 12 302086 Cut-off nipple Ø4 mm GV 34 / GV 60 13 302067 Cable (sw): Receiver - Thermocouple interrupter, L = 500 mm 14 302150 Switch with short length of cable to thermocouple interrupter and long length of
cable (tc), L= 500 mm, to receiver
15 310991 Hand-held transmitter: Display screen: Temperature and two programmes, receiver
and 8 wire connecting cable L = 500 mm 16 302424 Hand-held transmitter: Display screen: Temperature and two programmes 17 302420 Receiver GV 60 18 302068 8 Wire connecting cable L = 500 mm 19 302421 Ignition cable 2x (2,8 x 0,5 mm) L = 1500 mm
20 312478 Thermocouple M9 - 400 mm
21 311808 Thermocouple M9 - 1500 mm 22 302015 Thermocouple interrupter M9
23 310908 Pilot light set outer casing, Double flame 24 310909 Packing pilot light set outer casing 25 310910 Pilot light injector; natural gas; no 36 26 310912 Pilot light injector; propane; no 23 27 310907 Piezo electrode for pilot light; 2,8 x 0,5 mm 28 302062 Nut piezo electrode
29 ............ Pilot light olive; Ø4 mm
30 ............ Pilot light nut; Ø4 mm
31 ............ Pilot light pipe; Ø4 mm, L=….mm
32 ............ Burner pipe; Ø8 mm, L= …mm
98
Bellfires
English
Instructions for use and installation instructions
Logs - Embers - Stones - Marble pebbles
Log set consists of:
Log set Log Log set Log set Log set Embers Large, 5-piece Large Small, 5-piece Large, 7-piece Branches, 7-piece 2 bags à Inc. 2 bags 1x (Extension set) Inc. 2 bags Inc. 2 bags 100 gram embers à 100 embers à 100 embers à 100 gram gram gram
Stones
Marble pebbles
Set of large stones Color: white ± 20 pieces
Marble pebbles Color: white 2,5 kg.
Log set
Article no: 311011 311012 311003 321633 312914 311002 311008 310937
311880 2 1 3 311880 2 1 3 311883 1 1 2 2 311883 1 1 1 2 311879 1 1 2 311884 2 1 3 311879 1 1 2 311879 1 1 2 311883 1 1 1 2 311883 1 1 1 2 311879 1 1 2 311879 1 1 2 311879 1 1 2 311880 2 2 4 311879 1 1 2 311881 3 3 5 311880 2 2 4 311881 3 2 4 311880 2 2 3 311880 2 2 3 311880 2 2 3 319345 1 1 2 321634 1 2 2 319345 1 1 2 312913 1 nvt 1
Derby Derby II Jersey Flat Bell Topsham Topsham Tunnel York Kent Retro Bell Large Retro Bell Intermediate Retro Bell Small Retro Bell Solo View Bell Corner Bell Large Corner Bell Small Horizon Bell XL Horizon Bell Large Horizon Bell Large Tunnel Horizon Bell Medium Horizon Bell Small Horizon Bell Small Tunnel Vertical Bell Large Vertical Bell Large Tunnel Vertical Bell Small Smart Bell
Appliance
99
Bellfires
English
Instructions for use and installation instructions
10. DISPOSING OF PACKAGING AND APPLIANCE
The appliance comes in recyclable packaging. This can include:
Cardboard
Wood
Plastic
Paper Such materials must be disposed of responsibly, in line with local regulations. Batteries should be disposed of as chemical waste. Batteries must be disposed of
responsibly, in line with local regulations. The authorities or fitter can provide you with information on responsible disposal of
obsolete appliances.
01 - 010307 - 31 1813