IMPORTANT SAFEGUARDS AND PRECAUTIONS
A properly installed Bellfires®BM or BMR fireplace and its associated components form a safety tested system. This manual serves as a guide for the proper and safe instal­lation of a Bellfires®fireplace. It does not serve as a substitute for the necessary profes­sional judgment and skills of a trained installer. Instead, it should be used in conjunction with standard safety considerations including, but not limited to, applicable state or provincial and local fire codes, the National Fire Protection Association Standard NFPA 211 or Canadian Standard B365, building and inspection codes, and the trained installer’s professional judgment and skills to provide the owner with a safe installation. Please save these instructions for any future repairs or use.
Safe and efficient operation of the Bellfires® BM or BMR fireplace and its associated components mandates installation of this unit in accordance with this installation guide. Proper installation requires an installer skilled in standard construction tech­niques. The installer must read and understand the contents of this manual before starting the installation.
WARNING:
DO NOT PACK REQUIRED AIR SPACES
WITH INSULATION OR OTHER MATERIALS.!!!!
Consult the local and state or provincial building and fire safety code officials and
investigate the requirements for installing a factory-built fireplace in the homeowner’s community. It is the responsibility of the installer to (1) obtain a building permit for installation of a Bellfires®BSV fireplace before construction begins and, (2) assure the installation meets or surpasses all minimum requirements of the homeowner’s jurisdiction.
It is highly recommended the homeowner install a smoke detector.
Failure to use components provided or specified by Sleepy Hollow Chimney Supply, Ltd., manufacturers of Bellfires®, in accordance with this installation guide may create a fire hazard. Use of other components or misuse of Bellfires® components voids the Bellfires® warranty.
2
Page 3
Bellfires® BM & BMR
Table of Contents
Important Safeguards and Precautions 2 Introduction 4 Bellfires® Firebox Sizing Chart 5 BM Parts 6 BMR Parts 7 BM,BMR Exploded Views 8-10 BSV Spider Damper Parts 12 Safety Guidelines 13 BM, BMR Steps to Installation 14-28 BMR Specific Installation Steps 29-32 Bellfires® Spider Damper 33-34 Build the Best Fire in the World 35 Operation & Maintenance 36 Warranty 37
3
Page 4
Bellfires® BM & BR
Introduction
Early fireplaces were very inefficient, drawing a good deal of the heat up the chimney while admitting an unbearable amount of smoke into the room. In the late 1700’s, Benjamin Thompson, Count of Rumford, recognizing that a fireplace heats an area by radiation, began a series of experiments aimed at improving its performance.
He discovered through observations and various constructions that the exaggerated width of the chimney of his time, necessi­tated by the need for room for a chimney sweep to climb through the throat area into the flue, was a primary cause of inefficiency and smokiness. He attributed the problem not only to the chimney, but the width of the throat and also specific fireplace dimensions and configurations. Using the knowledge gained from his studies, Rumford modified the traditional fire­place design into one that burned cleaner and hotter and, most importantly, did not smoke. His efforts greatly improved the performance of the fireplace.
Later, in the 1900’s, a series of scientific experiments were conducted by Professor Peter O. Rosin, Dr. Ing., under the auspices of the British Coal Utilisation Research Association. The results are documented in his report, “The Aerodynamics of Domestic Open Fires”. Through the use of laboratory equip­ment, Dr. Rosin was able to observe air and smoke flow pat­terns and thus developed the ideal firebox and chimney shape for maximum efficiency. While expanding on Rumford’s work, some of Dr. Rosin’s findings varied dramatically from Rumford’s earlier theories; perhaps the most notable being the smoke shelf theory, shown diagrammatically at the left.
to improve the design.
Sleepy Hollow Chimney Supply has optimized the Bellfires® designs, and produced a superior radiant firebox combining advanced casting techniques and high temperature, high alu­mina ladle cast refractory. We feel confident that our Bellfires® units are the finest heat- producing open fireplaces to be found, whether used to upgrade old metal or masonry fireboxes or in new construction.
The Super Vent is the Repair Unit with the addition of a cor­rectly proportioned Smoke Chamber design, constructed of type 316 stainless steel for lifetime durability.
The Smoke Chamber is connected to a properly sized round or oval Super Flex® flexible flue liner. Cera-Foil® space age insulating blanket insulates the entire Super Vent™ system, stopping heat transfer to combustibles–the cause of home fires. In homes where the fireplace is in question for whatever reason, the Bellfire Super Vent has established itself as a safe, state-of-the-art, non smoking super radiant fireplace retrofit system.
A top mounted round damper with a control key at the firebox level helps to prevent cold air from draining into an unused fireplace and help ensure a warm flue for instant draft. Super radiant heat output and thorough combustion provide ample warmth and fuel efficiency that sets new standards for the open hearth. The refractory firebox stores heat and warms the house long after the flames have died out.
The important point of Dr. Rosin’s work is that it was per­formed in a scientific manner and pointed the way to a much more efficient and functional fireplace. Bell of England took this information and applied it to develop the Bellfire Fireplace, providing the ideal firebox and throat shape to guar­antee a smoke-free efficient fireplace capable of producing maximum radiant heat with minimum fuel. It was commonly used to heat the complete home until the second World War. Since then it has been further developed by using more mod­ern aerodynamic concepts and thermal insulation techniques
4
Page 5
Bellfires® Firebox Dimension Sizing Chart
Bellfires® Quick Reference Chart
Models 21, 25, and 28 (includes tall)
Bellfires® BM & BMR
Use this chart to determine which Bellfires® size firebox to install.
5
Page 6
Bellfires® BM & BR
Essential Components of a BM Installation
BM 21 BM 25 BM 28
A 16” 20 20 ”
B 9 12 12 ”
C 10” 9” 9”
D 11” 13 ” 14”
E 23 ” 26 ” 29 ”
F 25 ” 28 ” 28 ”
F tall 30 ” 33 ” 33 ”
G 8 ” 8 ” 8 ”
H 17” 21” 19
I 23” 27 ” 31 ”
J 41 ” 49” 49”
J tall 46 ” 54” 54”
K 20 ” 25 29”
L 31 ” – 42”
M 7” 7” – 8” 8”
N 7” 7” – 8” 8”
O 1” 1” 1”
Q 4 ” 4 ” 4 ”
The Bellfires® cutaway diagram at the left shows compo­nents necessary for a complete BM installation.
The key above shows specifications for individual models.
6
Page 7
Essential Components of a BMR Installation
BM 21R BM 25R BM 28R
A 7” – 8”
B 12” – 14”
C 10” 14” 14”
D 7” 7” 7”
E 16” 18 ” 18 ”
F 32 ” 39 ” 39 ”
G 25 ” 28 ” 28 ”
G tall 30 ” 33 ” 33 ”
H 9 ” 9 ” 9 ”
I 17” 21” 19 ”
J 23” 27 ” 31 ”
K 47 ” – 56 ”
K tall 52 ” – 61 ”
L 20 ” 25” 29”
M 31 ” – 42”
N 7” 7” – 8” 8”
O 7” 7” – 8” 8”
P 1” 1” 1”
Q 4 ” 4 ” 4 ”
Bellfires® BM & BMR
The Bellfires® cutaway diagram at the left shows compo­nents necessary for a complete BMR installation.
The key above shows specifications for individual models.
7
Page 8
Bellfires® BM & BR
BM 21 Tall 46 ”
41 ”
BM 21 Tall 30 ”
16”
25 ”
9 ”
17”
8 ”
10”
23 ”
23”
11”
BM 25 Tall 54”
49”
BM 25 Tall 33 ”
9”
12 ”
13 ”
20 ”
26 ”
28 ”
27 ”
8 ”
21”
BM 21 Tall & Standard
4 ”
Two Piece Hearth One Piece Hearth
31 ”
4 ”
31 ”
4 ”
20 ”
BM 25 Tall & Standard
4 ”
25”
One Piece Hearth
8
Page 9
BM 28 Tall 54”
12 ”
9”
14”
BM 21R Tall 52 ”
Bellfires® BM & BR
7”
7”
16”
20 ”
29 ”
49”
28 ”
BM 28 Tall 33 ”
8 ”
19 ”
31 ”
BM 28 Tall & Standard
12”
10”
47 ”
BM 21R Tall 30 ”
25 ”
17”
9 ”
32 ”
23”
BM 21R Tall & Standard
4 ”
Two Piece Hearth
31 ”
4 ”
31 ”
One Piece Hearth
4 ”
20 ”
31 ”
4 ”
Two Piece Hearth
4 ”
20 ”
One Piece Hearth
9
Page 10
Bellfires® BM & BR
8”
BM 25R Tall 33 ”
14”
28 ”
21”
9 ”
7”
18 ”
39 ”
27 ”
BM 28R Tall 61 ”
14”
14”
56 ”
28 ”
BM 28R Tall 33 ”
19 ”
7”
18 ”
39 ”
31 ”
9 ”
BM 25R Tall & Standard
4 ”
25”
One Piece Hearth
BM 28R Tall & Standard
31 ”
4 ”
Two Piece Hearth
10
4 ”
One Piece Hearth
20 ”
Page 11
Bellfires® BM & BR
11
Page 12
BSV Spider Damper Parts
For use with BMR Bellfires; add to order
1- Drop In Damper
28' Stainless Steel Cable
1 -Bracket
2 -Hammer Drive Pins
1- Stainless Steel Sash Chain
1 -Stainless Steel Ring (attach to chain)
1 -Stainless Steel Clamp (attach to cable)
You need....
Ladder
Hammer Drill
1/4 inch Masonry Drill Bit
Safety glasses
Wire Cutters
Marker
Flat Gasket or Silicone Caulk
12
Page 13
Bellfires® BM & BMR
Safety Guidelines
A. Bellfires® fireplaces are not approved for use in mobile homes. B. There must be an air space clearance between the outermost portion of any section of the chimney system and
any combustible surface. Although two inches is a typical clearance, adhere to the requirements set forth by the chim­ney manufacturer. Combustible surfaces include: ceilings, joists, flooring, walls, electrical wiring, insulation and roof structures.
C. Never fill any required air space with insulation or other material. D. The chimney system must be vented to the outside. E. The chimney must extend at least three feet (900mm) above the roof and at least two feet (600mm) above any
portion of the roof within 10 feet (3m). F. Maximum chimney height from the top of the firebox to the top of the chimney should not exceed 40 feet when
supported solely by the fireplace, or 90 feet when resupported at or above 40 feet according to the chimney manufac­turer's resupport specifications.
G. Minimum chimney height from the top of the firebox to the top of the chimney must be 10 feet. H. The chimney must not be inclined more than 30 degrees from vertical. Greater angles result in hazardous
deposits of soot and ash in flue. I. A maximum of two offsets (4 elbows total) is allowed in a chimney. J. Firestops and joist shields must be used at each floor level through which the chimney rises. K. There should not be any forced air furnace registers in the room within ten feet of the fireplace. They can cause
negative pressure and create chimney down-drafts. L. Never mix parts of one chimney system with those of a different manufacturer. Do not install damaged chimney
parts. Remember, more fires are caused by chimneys than by solid-fuel appliances. M. Practice good workmanship. Sloppy work could jeopardize the safety of the installation.
Less than 10 feet
3 feet minimum
2 feet minimum
Ridge
10 feet or more
2 feet minimum
3 feet minimum
Chimney Height Requirements
13
Page 14
Bellfires® BM & BR
Materials List
BLOCK AND BRICK SHELL NOT LISTED. Wing walls: 12-10" X 8" X 16" Block
4- 4" X 8" X 16" Block 2- 4' X8" X 56" Precast concrete lintels 4- Bags perlite for unit only
Brick ties 8" I.D. round flue liners or thimbles.
2- bags light masonry cement. BM 28 with two piece hearth. 1- masonry pipe adaptor. 1" X 24" X 25’ 8 lb. density CERAFOIL. 1/4" CERAFOIL gasket and hearth pad. 1- ROLL CERAFOIL tape. 1- 2 gallon pail SUPER CEMENT.
14
Page 15
Bellfires® BM & BR
READ INSTRUCTIONS CAREFULLY BEFORE BEGINNING.
Thank you for purchasing the Bellfire masonry unit, BM 28 TALL. These instructions are specified for a 36” finished opening. But dimensions can be altered to accommodate Models BM 21, BM 25, and the smaller height units.
After determining the fireplace location, check with municipal codes to assure proper depth for footing requirements. Pour footer base minimum 4’ wide X 8’ Long X 12" thick using a 5 bag footer mix.
Construct block base minimum 32" X 64" O.D., finished size, up to desired height of fireplace floor. Allow 4" ledge at ground level for veneer material, brick or stone. Block width walls should be laid inside of base for support.
15
Page 16
Bellfires® BM & BR
Cut the house wall rough opening at 56”
wide X 60”high. (FIG.2A) Pour a con­crete pad on block base 4”-6” thick and level off. If additional flue cham­ber is needed at lower level, build along with block base to a point higher than finished concrete pad. (FIG.2A 2B) The concrete pad must cantilever into formed floor joists, 24" for hearth. The BELL­FIRE performs best at floor level although a raised hearth may be used.
At this point the brick or stone veneer and 4” block back wall is built to a height of 56" above concrete pad. Use brick ties for fastening wing walls. (FIG.2, 2A)
16
Page 17
Bellfires® BM & BR
Straight edge a pencil line off interior finished walls. This line is the back of interior veneer material and also the extension of the BELLFIRE flares.(FIG 2B)
17
Page 18
Bellfires® BM & BR
With 10" block, build two wing walls against rough opening, flush with interior wall and pencil line. Use brick ties. (FIG.3) Stop wing walls at nearest block height above fire box, 40" on BM 28 TALL (FIG.3A)
18
Page 19
Using a sheet rock knife, measure and cut three 33” tall sec­tions of 1” Cera-Foil ceramic fibre high temperature insulating blanket. Allow 6” addi­tional width on each side to insulate firebox extension flares. Cut foil side and stand in place between wing wall. (Fig. 4, 4A).
Bellfires® BM & BR
Place 1” thick sections of Cera-Foil in place between wing walls. This technique accomplishes the follow­ing. The ceramic fibre insulating hot face forces the refactory firebox to store more heat, creating a cleaner and hotter burn­ing firebox. It also allows for a thermal expansion cushion with a built-in foil faced moisture barrier when the fireplace is exposed to the outside. (Fig 4A).
19
Page 20
Bellfires® BM & BR
Install the refractory fire box between wing walls and position flare exten­sions for proper centering. Remove side flares after firebox is properly centered. (FIG.5)
20
Cut 1/4” CERAFOIL insulating blanket to shape of the two piece hearth, installing foil face down. (FIG.6) With masonry saw blade cut outer piece evenly on both ends for proper rib alignment. Install two piece hearth. (FIG.6A,6B)
Page 21
Note on 6-A the pre­ferred method of installa­tion of side flare panels and front stretcher brick would be to rest flares on pad and cut stretcher to matching angles. 7-A shows a straight cut stretcher brick with cut shorter panels on top.
Bellfires® BM & BR
21
Page 22
Bellfires® BM & BR
Cut bottom of flare extension to angle of hearth. Make sure the top is level with fire box. (FIG. 7,7B) With SUPER CEMENT, butter the flare groove, the edge of block wing wall. and bottom of flare. Secure flares in place. (FIG.7A) Cut off excessive cement. Flares should be flush with block wing walls.
22
Page 23
Bellfires® BM & BR
Mix coarse pea size per­lite with light masonry cement at a ratio of 7:1 (7 perlite, 1-masonry cement). No sand is needed. (FIG.8) Before adding water, mix ingre­dients thoroughly. Slowly add water, bringing mix­ture to a potting soil con­sistency. (FIG.8A)
23
Page 24
Bellfires® BM & BR
Before pouring mixture, make sure the 1" CER­AFOIL is snugged against back of fire box. Pour mixture behind fire box tamping lightly in between pours. Fill open cores in block wing walls also. (FIG.8B, 8C)
Note CERA-FOIL used as a gasket/expansion joint at top of firebox 2­3”. Peel off foil backing.
24
Page 25
Cut 1" CERAFOIL pieces for masonry canopy, over lapping outside edges. (Fig. 9) with CERAFOIL tape. Adhere insulation to masonry canopy. (FIG.9A Make sure the CERA­FOIL pieces are 1” larger than the outside of the masonry canopy so that you can overlap the cor­ners. Use CERA-FOIL tape to adhere CERA­FOIL to the canopy.
Bellfires® BM & BR
BM specific directions
Cut 1/4" CERAFOIL in 2" wide strips, making a gas­ket in between firebox and masonry canopy. Remove foil from insula­tion. Install canopy on top of firebox, aligning inside back walls on both units. (FIG. 10)
With 1" CERAFOIL, insu­late around top round pipe adaptor. Use 1/4" insulation gasket between both units and secure in place (FIG. l0A)
25
Page 26
Bellfires® BM & BR
Lay another coarse of 10" block on wing walls leaving 4" open on out­side edge. Span across outer edge of wing walls with one 4" x 8" x 56" pre-cast concrete lintel (FIG. 11) Pour the void between lintel and masonry dome with per­lite mixture. Lay the sec­ond 4" X 8"X 56" pre­cast lintel in place, off­setting the first one by 4".
26
Page 27
Bellfires® BM & BR
Lay one block on each wing wall, filling the gap (FIG.11) on top of offset. Lay a coarse of 4" block leveling off the top. Don't forget brick ties for the veneer work. (FIG. 11B, 11C)
27
Page 28
Bellfires® BM & BR
Using SUPER CEMENT, butter the bottom of the flue liner and secure to top of unit. (FIG.12) Fill the remaining void with perlite mixture. (FIG.12A, 12B)
From this point up the chimney is built in a nor­mal fashion, although the void between the filler block and the liners should be filled with per­lite mix. This assures expansion capabilities and insulating proper­ties. After chimney is completed, return to the inside for the veneer of your choice.
28
Page 29
Install refractory dome on top of firebox aligning inside back walls flush on both units. (Fig 9). Make sure the CREA-FOIL pieces are 1” larger than the outside walls of the masonry dome, so you can overlap the corners. (Fig. 10).
Bellfires® BM & BR
BR specific directions
29
Page 30
Bellfires® BM & BR
Using SUPER CEMENT refractory mortar, butter top of refractory dome. (Fig ). Place refractory turbo transition on top of refractory smoke dome, aligning inside back walls flush on both units. (Fig ). With 1” CERA­FOIL, insulate around refractory turbo transi­tion. (Fig ).
30
Page 31
Using SUPER CEMENT refractory mortar lay another coarse of 10” block on wing walls leav­ing 4” open on outside edge. Span across outer edge of wing walls with one 4” x 8” x 56” precast concrete lintel. (Fig ). Pour the void between lintel and masonry dome with perlite mixture. Lay the second 4” x 8” x 56” precast lintel in place, off­setting the first by 4”. (Fig. ).
Bellfires® BM & BR
31
Page 32
Bellfires® BM & BR
Using SUPER CEMENT, butter the bottom of the flue liner and secure to top of unit. (FIG.12) Fill the remaining void with perlite mixture. (FIG.12A, 12B)
From this point up the
chimney is built in a nor­mal fashion, although the void between the filler
block and the liners should be filled with per­lite mix. This assures expansion capabilities and insulating properties. After chimney is complet-
ed, return to the inside for
the veneer of your
choice.
32
Page 33
Bellfires® BMR Spider Damper
25-1
25-3
Round chimney liner
25-4
25-2
25-5
PLEASE
NOTE!!!
The Spider Damper® may only be used with the Bellfires® BMR model. The Bellfires® BM is usually installed with rectangular tile and the Spider Damper is only usable with round liners. We recommend using a rectangular top mounted damper such as the Lyemance Locktop.
After the chimney liner has been installed, but before the chimney cap is placed, the top mounted Spider Damper must be installed. The Spider Damper is placed in the top section of the chimney liner.
The Spider Drop-in Damper (25-1) (Part #21) installs typically like other top mounted dampers. The bottom hook-up is also typical. Attach the ring on the 28’ stainless cable (Part #22) to the underside ring of the Spider Damper. (25-2) The installer must go to the roof and place the Spider Drop-in Damper inside the top section of the chimney liner until handles of damper don't go any further down. (25-3, 25-4) Unroll cable, dropping it all the way down the flue until cable reaches the firebox. The important installation step to be observed is as fol­lows: check for tightness in between flue walls and outside damper. Any air clearance should be sealed with flat gasket or silicone caulk. (25-5) Check damper plate to be sure it moves freely. Because blade is counterweight, damper should always be in the opening position.
33
Page 34
Bellfires® Spider Damper
26-1
3”
20”
26-2
Stainless steel clamp
26-5
26-3
26-4
Hearth
Now, go back inside to the BMR firebox. Take the "L" bracket (Part #23) and place it at wall of firebox (26-1) about 20" from hearth and no less than 3" from outside opening. With a marker, mark the two openings of the “L” bracket onto the side of the firebox. (26-1) Be sure to wear your
safety glasses. Using a masonry drill bit, drill two 4” inch holes into fire­box on the marks you made. Attach "L" bracket with hammer driver. (Part #24) (26-2). Close damper by pulling cable until slight tension is felt. (26-3).
Cut stainless steel wire about 12 inch lower than the horizontal bar of bracket. (26-4).
1 ”
Take opposite end to ring of stainless steel chain and slide it through bracket from bottom to top. Slide end of cable through first link of sash chain (Part # 25)(26-5) and through clamp (Part #26). Attach to cable by squeezing with pliers. At this time damper should remain closed.
Position clamp and be sure that first link of chain is 12 inches over the horizontal of bracket. After the attach clamp is secure against cable your Spider Drop-in Damper is ready to be used.
34
Page 35
Build the World’s Best Fire
Top Down Burn
Handy Items to Have
A Fireplace Screen A Kindling Ax (Be careful) Stove Gloves An Ash Rake
Think of your fuel load as three component parts: The Base Course (can be unsplit if proper diameter) The Middle Course (split) The Top Courses (split finer)
THIS TYPE OF FIRE IS NOT RECOMMENDED FOR THE FIRST EIGHT TO TEN FIRES. BELLFIRES® MUST BE GRADUALLY BROKEN IN AND CURED WITH SMALL FIRES FOR THE FIRST EIGHT TO TEN FIRES.
DO NOT OVERFIRE YOUR BCC!! A fireplace grate is not necessary with the BCC 28. A
grate increases your critical burn rate allowing logs to burn faster than normal. Logs burn best in contact with hot firebrick in a bed of wood ashes.
Helpful Hints & Precautions before you start:
Make sure your fireplace and flue have been inspected for fire worthiness and are cleaned if found dirty (full of flammable cresosote), by a reputable Chimney Sweep. Make sure the damper is open. The damper is controlled from the keyed stainless cable and ring installed to either side of the firebox sidewall. Pull down and unhook to release the tension of the stain­less steel cable. Pull down and rehook the cable to close the damper. There are no other settings than completely open or completely closed. If your fire­place and flue are located on an outside wall or, when the damper is open, you feel a flow of frigid air rush­ing down into the room, pre-heat the flue with a sheet of lit newspaper. Hold the lit newspaper high into the damper area, wearing a pair of stove gloves for protec­tion. This will reverse the cold air plug present in the flue, creating a strong updraft with no smoke into your room. As soon as the newspaper is burned up, light your newspaper on top of your fuel load. Approximately 3-4 hours later when you have a nice bed of hardwood coals, use a fireplace rake to push the coals against the rear wall of the firebox. Next, lay your new logs, minimum of four, on top of the hot coals, lay the bottom two horizontally. The top two, a little short­er in length, place front to back approximately 3 inch­es apart creating a throat.
The greatest volume of smoke and particulate pollu­tion from a wood fire occurs during a cold start up.
Wood fires lit from the bottom, in a conventional man­ner, promote a dirty burn and waste a large amount of potential heat in the form of unburned gases.
A clean and efficient method for kindling a fire is a top burn. This almost forgotten ancient European tech­nique places the largest wood at the bottom in a criss cross crib fashion. As each tier is laid, the criss cross­ing becomes smaller. Kindling and a small amount of paper are placed on top and lit.
When the top burn fire is lit, the flames are always above the fuel load. The smoke and flammable gas from each tier of wood will always travel up through the flame and burn, thereby reducing particulate pol­lution and unburned fuel.
A top kindling fire also produces large and less com­pacted glowing coals, providing excellent long-lasting radiant heat.
A top burn fire laid with seasoned hardwood to a height of eighteen to twenty-four inches will burn approximately four hours without adding additional wood. The fire will be mesmerizing as each tier slowly ignites and burns its way down.
TOP BURN RECIPE
Always start with dry, well-seasoned, split firewood and kindling. (Ideally seasoned firewood will have a 20% moisture content. The wood will show radial cracks at the ends and sound like bowling pins when beaten together.)
Bottom layer: Three good sized pieces of split hardwood five to six
inches thick, laid front to back. Second layer:
Three slightly smaller pieces of split firewood three to five inches thick, laid side to side.
Third layer: Four to five smaller pieces of split firewood two to three inches thick, laid front to back. Keep afternating and decreasing in size with split hardwood until they are about one inch thick.
Now alternate two rows with split softwood (pine, spruce, etc.) until pencil thick. Place a small piece of newspaper on top and light.
35
Page 36
Operating Instructions & Maintenance
BM, BMR Operating Instructions & Fireplace & Chimney Maintenance
Keep These Instructions
for Future Use
NEVER USE GASOLINE, GASOLINE-TYPE
LANTERN FUEL, KEROSENE, CHARCOAL-
LIGHTER FLUID, OR SIMILAR LIQUIDS TO
START OR “FRESHEN UP” A FIRE IN THIS FIRE-
PLACE. KEEP ALL SUCH LIQUIDS WELL AWAY
FROM THE FIREPLACEWHILE IT IS IN USE.
Use solid wood or processed
solid fuel firelogs only.
Do not poke or stir logs while they are burning.
Use only firelogs that have been evaluated for
the application in fireplace and refer to firelog
warnings and caution markings on packaging
prior to use.
Beware of burning certain materials in your fireplace.
These items include plastic, poison ivy , and chemically
treated woods such as pressure-treated lumber, discarded
telephone poles, or railroad ties. These not only create air
pollution, they can induce extreme illness or irritation for
some individuals. Do not burn driftwood that has been in
the ocean or in salt water as the salt will corrode the chim-
ney. Do not abuse the fireplace by overfiring by burning
paper, cardboard, or construction materials such as
pressed wood, plywood, or lumber. Some fuels, such as
charcoal, natural gas, etc., give off carbon monoxide when
they burn. As this is a toxic gas you should insure that the
fireplace does not spill flue gas into the house.
Disposal of Ashes
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground well away from all combustible materials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Ashes should never be placed in a container with combustible materials.
Chimney Maintenance
CREOSOTE–Formation and Need for Removal
When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow burning fire. As a result creosote residue accumulates on the flue lin­ing. When ignited this creosote makes an extremely hot fire.
The chimney should be inspected at least twice a year during the season to determine if creosote buildup has occurred.
If creosote has accumulated it should be removed to reduce the risk of a chimney fire.
Check the specific chimney manufacturer’s instruc­tions on removal of the chimney cap for chimney cleaning.
When the fireplace is first placed in use inspect the chimney frequently and clean the chimney anytime an accumulation of 8 ” thick or more is observed on the flue walls. The frequency of these inspections can be increased or reduced appropriately after a pattern of accumulation has been established. Please note how­ever that changes in the outside environmental condi­tions such as temperature and humidity, or changes in the operation of the fireplace can lead to rapid buildup of soot and/or creosote.
To clean the chimney obtain the services of a qualified and reputable chimney sweep or remove the accumula­tion with brushes on wooden, poly, or fiberglass poles. Do not use metal pipes, chains, wires, etc., to clean the chimney because such items can scratch the surface of the stainless steel flue which can shorten the life of the flue and provide a rough surface for soot particles to attach to.
In addition to checking and cleaning the chimney on a regular basis, be sure to inspect the chimney before starting a fire at the beginning of each heating season. Make sure the chimney is clear from any accumula­tion of soot, creosote, or any other debris and that all chimney joints are intact.
36
Page 37
Bellfires® BM, BMR
CONDITIONS OF WARRANTY
LIFETIME WARRANTY
Bellfires® Manufacturing Company extends the following warranty on the BM or BMR, subject to the conditions of guarantee thereon. The fireplace is warranted for the lifetime of the original owner from the date of installation. If examination by the Bellfires® representative proves to our satisfaction that any part or portion of the fireplace is defective in material or workmanship, under normal use and ser­vice, such part or portion shall be replaced or repaired at no cost to you.
(A) Warranty may not be altered or extended by any of our dealers or agents, and except as provided herein, there are no other warranties. (B) Warranty does not cover damage resulting from misuse, abuse or accident. (C) Warranty shall be void if your unit is not operated in accordance with the oper­ation instructions provided at time of purchase and outlined below, or if the unit has been removed from the place in which it was originally installed. (D) Hairline cracking on the surface of refracto­ry components, a normal condition of use for refractory products, and/or cracking are expressly excluded from this warranty.
Important Instructions For Curing Refractory Fireplaces: (1) If the firebox has gotten wet, it must be dried slowly with a hair dryer or heat lamp before any fire is started. (2) The first eight fires must be built very small and well forward on the hearth so as not to contact the firebox. This will allow the unit to cure slowly by removing excess moisture in the refractory cavity behind the firebox, caused by the environment during storage or transportation, and mortar and materials used for installation. Proper curing eliminates the possibility of fracturing the firebox.