Bell 500LX User Manual

WiringDiagramforDoorEntrySystems
500LX
with500LXseriesoftelephones
TelephoneModels:
500LX500PLX 500LXT500PLXT 500LXC500PLXC
System
DoorPanel
Flats
L V Z T
O
I
L
V
Z
T O R
I
Second
Telephone
First
Telephone
T O R
Speech
Unit
51/61
Morediagramscanbe foundonourwebsite:
www.bellsystem.co.uk/
DoorMonitor
Switch
203,204
LockRelease
ElectricalCupboard
M340
PowerSupply
-
13:44 56
+
CO NO NC
TS2000
TimeClock
PD-039ISSUE1
InstallationofDoorEntrySystems
ImportantSafetyInformation
Themustbeplacedinaprotectedindoorenvironmentsuchasan
PowerSupplyUnit
electricalcupboard,closetoa240VACelectricalsupplyandlocatednofurtherthan50 metresfromtheentrancepanel.Itmustbewall-mountedontoplasterboard,woodora similarnon-conductivematerial.
Connectionstothe240VACmainssupplymustbecarriedoutbyaqualifiedelectricianor similarcompetentperson,andmadeinaccordancewithacceptedsafetypractices.Atwo­poleswitch(asprovidedbyaConsumerUnitorSwitch-Fuse)mustbeincludedtoisolate bothLiveandNeutralduringInstallationorMaintenance.T hetransformerisprotectedby fuses;alwaysreplacethesewiththecorrecttypeandrating.
UseonlymainscabletoBS6004orequivalent,withinthefollowingspecifiedlimits:
ConductorDiameter:
CableDiameter:
Theisdesignedtobewall-mountedinaconvenientindoorlocation.
DoorEntryTelephone
The,containingthespeechunit,isavailablewitheitherasurfaceorflush-mountingback
Entrancepanel
box.Normallythiswouldbemountedonanoutsidewallnearthefrontdoor,andifpossibleinasheltered location.
Theisdesignedforuseonaninwardopeningdoorfittedwithasurface
Model203ElectricLockRelease
night-latchtypelock.Thisshouldbeinstalledwithasmallamountofplayonthedoorasoperationwillbe impairediftootight.
Tradesmanbutton(optional):
duringrestrictedhours.
Cablerequirements:
usingtwisted-pairtelephonecable(egtypeCW1308).UseoneofthepairsfortheR&Oconnections betweenthespeechunitandthetelephone.
Foroptimumspeechclarit y,itisstronglyrecommendedthatthissystemisinstalled
Thisisusedinconjunctionwithatime-clocktoallowtradesmenaccess
Min.1.0mm(0.8mm)
Min.4.0mm
2
Max.2.25mm(4mm)
Max.8.0mm
2
Installation:
telephonebeconnectedatatimeandfullytestedbeforeproceedingtothenext.
Speechadjustment:
Iffeedbackisexperienced(ahowlorwhistle)turnbothcontr olsto'off'andthenslowlyadjusteachupinturn untilasatisfactorylevelofspeechisattained.
Troubleshooting:
disconnectingalltelephonesandre-connectingasingletelephonewithashortlengthofcable(ROTonly); Reconnectthetelephonesoneatatimeuntilthefaultre-appears.Note:speechwillbeimpairedifoneor moretelephonesareleftoffthehook.
Connectallitemsbyfollowingthediagramoverleaf.Itisstronglyrecommendedthatasingle
Thespeechunithastwocontrolsattherearforadjustmentofspeechlevels: VolumeA:SpeechlevelattheEntrancePanel VolumeB:SpeechlevelattheTelephone
Nospeech/insufficientspeech:InitiallyestablishcorrectoperationoftheSpeechUnitby
Loading...