Capacity 350 500 650
Max Load 190 W 300 W 360 W
Voltage Range
Frequency
Voltage (On battery)
Voltage Regulation (AVR)
Transfer Time
Spike Protection
EMI/RFI Filter
Overload Protection
Unit Input
Telecommunication
Protection
Short Circuit
Voltage / Amps 12V / 5Ah 12V / 5Ah 12V / 7Ah
Type
Typical Recharge Time
Protection
Battery Run Time Upto 15 minutes Upto 28 minutes Upto 35 minutes
Battery Backup
Battery Low
Overload
Fault
Battery Test
Ambient Operation
Audible Noise
Weight (lbs) 8.81 10.14 12.34
Dimension W x D x H
AC Power On
Power Off
Cold Start (Turns DC
Power On)
Buzzer Silence (On Battery
Mode)
Front Panel
Switch
105 ~ 135 Vac
60Hz ±1Hz
60Hz ±1Hz
Simulated Sine Wave, 120Vac ±10%
Breaker for overload and short circuit protection
1 In, 2 Out Single Line (2 Wire, RJ11) jacks
No AVR
N/A
510 Joules
UPS shuts down
Sealed, maintenance free lead acid
<8 Hours
Model
Input
Protection and
Filtering
Output
Battery
Meets FCC Class B
UPS Low voltage switch to high voltage switch to battery: 105 ~ 135 ±3 Vac
Automatic self discharge protection, replace battery indicator LED
Flashing Red LED and Audible Alarm 10 second continuous
Solid Red LED Light
Slow beeping sound (about 15 second intervals)
UL/cUL, EMI, IEC 1000-4-2 Level 3, IEC 1000-4-4 Level 2, IEC 1000-4-5 Level 3, FCC Part 68, CS-03, USB models are Microsoft XP Certified.
9.84" x 6.61" x 3.15"
0 ~ 85% Relative Humidity (Non-condensing); 0 ~ 35º C Operation Temperature
<40dBA at 1 meter
Alarm
Environment
Communication Port
Press less than 1.5 sec.
Press and hold longer than 2 sec.
Press and hold longer than 2 sec.
Press and hold longer than 2 sec.
Compliance
Physical