Belkin F6H350-USB, F6H650-USB User Manual

F6H350-USB F6H500-USB F6H650-USB
○○○○
R
ALARMS
Back Up (Slow Alarm)
When in “BACK UP” on bat tery mode, the RED LED illuminates and the UPS sounds an audible alarm. The alarm stops when the UPS returns to LINE NORMAL operation.
Low Battery (Rapid Alarm)
In “BACK UP” mode, when the battery energy runs low, the UPS beeps rapidly until the UPS shut s from a depleted battery or returns to LINE NORMAL operation.
Fault (10 Seconds Continuously)
When the output is shorted, the UPS emi ts a 10 seconds continuous l y alarm to warn of a short conditi on. Disconnect the equipment prior t o checking the equipment .
FRONT PANEL
INTRODUCTION
Thank you for purchasing a Belki n Uni nterruptible Power Supply (UPS). Each year, several natural and man made occurrences put the power supplied to your electronics i n your home or office in jeopardy. At risk are your hardware, software and data because of these power problems.
Please save this manual!
It contains important operating instructions and warranty information pertaining to your UPS.
Please save or recycle the packaging materials!
The UPS packaging was designed with great care t o provi de protection during shipment and delivery. These materials are invaluable if you ever have to return the UPS for service. Damage sustained during transit i s not covered under the warranty.
Federal Communications Commission In terference S tatem ent This equipment has been tes ted and found to comply with the limits for a Class B digital device, pursuant to Part 15 of t he FCC Rul es. These limits are desi gned to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radi o frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference t o radi o communications . To assure continued compliance, use onl y shielded interface cables when connec ting to computer or peripheral devices . Any changes or modific a t i ons not expressly approved by the party responsible for c ompliance could void the user’s authorit y to operate this equipment.
CONTENTS
You should have received the following: 1 – UPS unit 1 – Sentry Bulldog Shutdown Software 1 – USB Cable 1 – Phone Line Cable
UPS Outlets (See #1 on Diagram 1)
1. These outlets are your battery back up outlets. We strongly recommend that only sensitive equipment such as your computer and monitor should be plugged into t hese outlets. Caution: Never
connect a laser printer or scanner to the backup outlets of UPS with other computer equipment. A laser printer or scanner draws significantly more power when in use than when sitting idle. This may overload the UPS.
Should a power outage occur, your battery backup would automatically turn on. Power (utility or battery) is not supplied to these outlets when the UPS is switc hed off .
Do not plug any surge protectors or power stri ps into the battery back-up outlets (i.e. dai sy chaining).
SURGE Protected outlets (See #2 on Diagram 1)
2. These outlets do not provide power during a power outage.
Equipment such as computer peripherals, print ers, fax machine’s, or a desk lamp may be plugged into these outlets. The On/Off button does not control these outl et s.
3. The On/Off button has 3 functions:
1. Turns on the UPS. Depress button at l east 2
2. Cold Start function. Assuming the battery is
UPS FEATURES AND FUNCTIONS
Before installation, please inspect the UPS upon receipt. Make sure that nothing is damaged.
3. Silence function. During “On Battery Mode”, the
Your UPS features 3 LED indicators. Each is marked by a power icon; please familiar iz e y o u r self with this chart, as it will assist you in the use of your UPS.
Side Panel A
Indicator Condition Description
- Solid green
AC power is on
ON-LINE
ON-BATTER Y and LOW-BATTERY
SITE WIRING
FAULT
- Flashing Red
LED with Audible
Alarm (Beeping)
- Solid Red
Chart 1
This condition for the On-Battery and Low-Battery LED can indicate 1 of 3 problems:
1. The UPS i s on battery backup and an intermittent audibl e alarm is on. The UPS will begin shutdown procedure.
2. Battery is low. The UPS will start shutdown . The buzzer sounds an audible alarm.
3. There is a probl em with the UPS. The LED will be lit continuously and the buzzer will sound audible alarm for 10 sec.
The Site Wiring fault LED can indicate 1 of 2 possibl e conditions:
1. Open or high res i stance on the ground line
2. Hot or neutral polarity
circuit
*Note in order for your UPS to work properly, you must have a properly grounded AC circuit. If your Site Wiring Fault LED i s lit, please contact an electrician to properly wire this circuit.
4. AC Input Power Cord (See #1 on Diagram 2) Provides power to your UPS.
5. Phone/ Fax/ Modem Surge Protection (S ee #2 on Di agram 2) The Phone/ Fax/Modem lines are surge protected. There is one input jack and two output jacks. This allows you to split one t el ephone connection to two separate devices.
6. AC Breaker (Circuit Breaker; See #3 on Diagram 2) Should a power overload occur, the circuit breaker would trigger the UPS to turn off AC power. In order to restore the power, depress the circuit breaker button t o reset, then depress the Power button.
Side Panel B
7. Your UPS features a USB communication port . Installation of the cable and software is optional. This allows the UPS to connect to you computer. The Sentry Bulldog Software will not work if the UPS is not connected to you comput er. This does not mean the battery backup feature will not work without the software and cable installed. The UPS will still provide backup power but you will be unable to utilize the data management capabilit ies of the software.
2222
1111
Diagram 1
seconds. The green light will come on.
charged the UPS will work without it being plugged into an outlet. Depress and hold the key for at least 2 seconds to turn on the UPS. The
audible sound can be turned “ON” or “OFF” by depressing the switch.
Circuit Breaker Push to Reset
3
Refer to Bottom for Cautionary Markings
Diagram 2
Diagram 3
AC Input
OUT
Phone/Fax
Modem
OUT
Protection
IN
USB Communication Port
3333
Battery Light
1
2
INSTALLATION
Note!
Before installation, pl ease inspect the UPS Upon receipt. Make sure that everyt hi ng i nside the package is not damaged.
Connect to AC Utility Power
Connect the AC inlet to utility power via the power cord. Please make sure there are no devices plugged into the UPS unit. Chec k to see if the “Site Wiring Fault” indicator is lit or not. If it is lit, please have the utility wiring inspected by an electrician.
Charging the Battery
For best results, charge the battery for 6 hours prior to initial use. The UPS charges its battery whenever it is connected to the utility power. Should you see the red battery light com e on, the battery may need
Battery Light
immediate charging.
Turning on the UPS
Turn on your UPS by depressing the On/Off button for approximately 2 seconds. You w ill see the green indicator light co me on.
Plug in Power Devices
Plug your devices into the AC out l ets on the top of the UPS. To use the UPS as a master on/off switch, make sure al l of the loads are switched on.
Caution: Never connect a laser printer or scanner to the backup outlets of UPS with other computer equipment. A laser printer or scanner draws significantly more power when in use than when idles. This m ay overload the UPS.
Laser Printer
Connect the phone/ fax/ modem lines
Connect a single phone / fax/ modem line into the surge protect ed sockets on the right of the UPS. The RJ-11 modular sockets accept standard single line telephone connections.
Plug one end of the phone cable you received into your telephone wall jack and plug the other end into the j ack marked IN. You may now plug a phone, fax or modem into the two jacks marked OUT. (See Diagram 4)
Phone
Modem
To Telephone Socket
Note: This connection is optional but highly suggested as phone / fax / modem lines often carry dangerous surges and spikes. The UPS works properly without a phone / fax/ modem connection.
Caution: The phone/fax/modem protection feature could be rendered inoperable if improperly installed. Make sure that the telephone line from the wall is plugged into the connector marked “IN”, and the devices to be protected (phone/ fax/ modem) are plugged into the connector marked “ OUT”.
USB (Universal Serial Bus) Communication P o rt
A USB port is provided to relay the signal to support DOS, WINDOWS, and the other operating system.
Communication port
(Optional) To fully utilize the Sentry Bulldog Shutdown Software; you will need to connect the UPS to your com puter. Connect the USB cable to your UPS then connect the other end to the USB port on your computer.
Software Installation (Optional) Compatible with any comput er runni ng the following: 95/98/ME/NT4/2000/XP & Novell 3.X & Higher
1. Your UPS features the Sentry Bulldog Shutdown Software.
This allows you to protect and save your dat a should a power outage occur, as well as safely shutdown your computer in your absence. This software is compatible with Wi ndows 95/98/ME/NT4/2000/XP and Novell 3.X & higher.
2. To install the software, please place the CD into the CD drive of
your computer.
3. Your computer should automatically run (AutoPla y) t he CD. If
this does not occur, go to the Run feature on your Start icon (lower left corner) on your screen. Pleas e enter the CD drive, it may be D: Should you continue t o have a probl em, please refer to your computer ’s owner’s manual for the correct dri ve. Upon entering the drive Run setup.exe. to execute the s of tware.
4. Once uploaded, please click the Bulldog icon on the screen.
5. Click Install Belkin Sentry Bulldog for Win
95/98/ME/NT4/2000/XP
6. InstallShield Wizard will appear onscreen, c lick Next.
7. Please read the License Agreement and click Yes.
8. On Setup Type, click ALL (Standalone). You should not install
the networking files unless you are technically qualified to use these features. For more i nformation on networking, please refer to the software user ’s manual. The software user’s manual can be downloaded from the user’s manual icon.
/ Fax
Diagram 4
9. On Choose Destination, you have the opt i on to choose the location of where you would like the Sentry Sof tware located on your computer. W e recommend using the defaul t option as shown on screen. To use the default option, c l i ck Next.
10. On Select Program Folder, you have the option to choose t he program folder for you Sentry Software. We recommend using the default option as shown on screen. To use the default option, click Next.
11. The software will now upload. Once completed, please click Finish.
12. We recomm end t hat you download the user’s manual you’re your reference. To do this, please cli ck the appropriate user’s manual listed on the screen.
13. Click X on the Bulldog setup screen to leave the software setup.
14. Please refer to the user’s manual for software setup and information on soft ware spec i f i c features and functions .
Uninstall for Windows 95/98/Me/NT4/2000/XP
There are two options to uninstall the Sentry Belkin Shutdown Software.
1. Select the Setup from the BELKIN SE NTRY BULLDOG program folder and select the remove option to begin the uninstall procedure.
2. Select Add/Remove Programs from the Control Panel and click on the BELKIN SENTRY BULLDOG item then press the Add/Remove button.
TECHNICAL SPECIFICATIONS
MODEL
INPUT
OUTPUT
BATTER Y
ENVIRONMENT
F6H350
-USB
RATED
CAPACITY
350VA /190W
RATED VOL TAGE
PHASE /
FREQUENCY
VOL TAGE
FREQUENCY
Desktop
BACK UP TIME
RECHARGE
TIME
computer
+15”
monitor
10mm
TEMPERA TURE
HUMIDITY 10~90%
F6H500
F6H650
-USB
500VA /300W
105-135Vac
Single phase 60HZ
Step wave
60HZ
Desktop
computer
+17”
monitor
13mm
Desktop
computer monitor
8hours to 90%
0~35
-USB
650VA /360W
+17”
17mm
SAFETY UL1778 / C-UL
SAFETY
REGULATION
APPEARANCE
EMI FCC CLASS B
EMS IEEE C62.41 CATEGORY A
DIMENSION
NET WEIGHT
3.14 X 9.84 X 6.6 inches
4.0KGS/
8.82LBS
4.6KGS/
10.14LBS
5.6KGS/
12.35LBS
All specificat i ons are subject to change without prior not i ce.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Press the On/Off button more than 2 second
Recharge the UPS at least 5 hours
Contact Belkin T echnical support at
Power LED is not lit
UPS will not power on
On/ Off button not pushed or pushed less than 1 second
Battery voltage less than 10V
UPS fault
techsupp@belkin.com Re-plug the power
cord
Reset the breaker
Normal operations
UPS always on battery mode
Power cord loose
AC breaker is tripped
Power disturbances have occurred
Back up time is very short
Battery is not full y charged
UPS is overloaded
UPS fault
Recharge the UPS for a minimum of 6 hours
Remove un-necessary power loads (devices)
Contact Belkin T echnical support at techsupp@belkin.com
STORAGE
Storage Conditions
Store the UPS covered and upright in a cool, dry location with its battery fully charged. Before storing, charge the UPS for at l east 6 hours.
Extended Storage
During extended storage in environments where the am bi ent temperature
o
is +5
F to +86 oF, charge the UPS battery every 6 months. During
extended storage in environments where the ambi ent temperature is +86
o
F to +113 oF, charge the UPS battery every 3 months.
Note:
Away from sunlight Away from heat Away from water
BELKIN COMPONENTS USER LICENSE AGREEMENT
Belkin Components (B el kin”) thanks you for choosing one of our products for your use. This User License Agreement (Agreement”) contains the terms and conditions under which l i mited use of the product i s licensed to you. PLEASE READ THIS NOTICE CAREFULLY DO NOT USE THE SOFTWARE OR PRODUCT UNTIL YOU HAVE READ AND AGREED TO THIS AGREEMENT. IF YOU USE THE SOFTWARE AND PRODUCT, YOU ARE AGREEING TO THE TERMS AND CONDITIONS SET OUT IN THIS AGREEMENT. IF YOU DO NOT ACCEPT THESE TERMS AND CONDITIONS, YOU MUST RETURN THE UNOPENED PRODUCT WITH THE DISKS INSIDE TO THE PARTY FROM WHOM YOU RECEIVED IT. SCOPE OF USE: In this Agreement, soft ware m eans all machine-readable software programs and associated files in this package, All modified versions of and upgrades or improvement s to such programs and all copies of such programs and files. You, a single user opening this envelope (You or our), may use the software on a single central processing unit. You may not rent it, loan it out, or lease it , nor use it on a multi-user system. LICENSE: You have the non-exclusive right to use the sof tware. You are not permitted to copy, modify or transfer the software or documentation. You may not compile, di sassemble or otherwise reverse engineer, break down, analyze or modify the software. USE AND RESTRICTIONS: You are permitted to make backup copies of all the software disks for archival purposes only. You must reproduce the proprietary notice set forth on the disks and affix them to all backup copies. You are not permitted to use these programs in connection with a computer service, or to use the backup copies other than as a replacement for the original copy. TERM: This license is effective upon acceptance by opening this envelope or in any other way using the enclosed software, which will constitute your acceptance of, and agreem ent to, this Agreement , and i s effective until terminated. The limited license in this Agreement will be automatically terminated if you fail to comply with any of the Terms and conditions in this Agreement. You agree that upon such termination you will immediately destroy all programs and documentation, including all copies made or obtained by you. SOFTWARE, PROGRAM, DOCUMENTATION, AND ANY RELATED INFORMATION, GOODS OR SERVICES ARE PROVIDED WITH NO WARRANTY OR REPRESENTATION OF ANY KIND WHAT SO EVER. BELKIN HEREBY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The entire risk of the use, results and performance of t he software, program and documentation i s borne by you. S houl d any or al l of the product, software, program, documentation, or related information, goods or services be defective, misused, unsuitable or cause or give rise to any harm or liability whatsoever, you, not Belkin or its associates, dealers or agents, assume the entire liability, cost of repair , correction or any payment or other remedy whatsoever. Furthermore, no warranty or guarantee is made regarding the use or results of the product, software, program , documentation, or any relat ed i nformation, goods or services in terms of correctness, accurac y, reliability, timeliness or otherwise. You use and rely on the program at your own risk. The foll owing is the only and exclusive warranty and remedy of any kind: Bel kin does warrant that the program disks are free from physical defects in materials and workmanship under normal use f or a peri od of one (1) year from the date of purchase, as evidenced by a c opy of the sales receipt. Return the defective disk or documentation with your receipt directly to Belkin for a replacement. DISCLAIMER: Belkin or its associates will in no event be liable (i) in any amount for lost profi ts or special, incidental, punitive or consequential damages, or (ii) for any cl ai m or damage of any nature, or under any theory, whatsoever, in any amount in excess of the purchase price you paid for the product. The warranties and remedies here set forth are exclusive, and in lieu of all others oral or written, express or implied. Some jurisdictions do not allow exclusion or limitation of implied warranties or of liability for incidental damages, s o the foregoing limitations or exclusion may not apply to you. This warranty gives you specific legal rights, which vary from juri sdiction to jurisdiction. HOWEVER, YOU WAIVE SUCH RIGHTS, EXCEPT AS EXPRESSLY PROVIDED UNDER THE TERMS A ND CONDI T IONS OF THIS AGREEMENT, TO THE MAXIMUM EXTENT ALLOWED BY LAW.
The license is governed by the laws prevailing in the State of New York, without regard to its conflicts of laws principles.
ACKNOWLEDGMENT:
By opening the package on which this Agreement is printed, or through which it is visible, you ac knowledge that you have read this Agreement, understand it, and agree that this agreement is the complete and exclusive statement of agreement between yourself and Belkin and supersedes any prior agreements, oral or written, and any other communications relating to the subject matter of this Agreement.
SEVERABILITY:
Any term or provision of t hi s Agreement or any applicati on thereof, which may be prohibited or unenforceable by law in a parti cular jurisdiction, shall be interpreted and enforced to the maximum extent allowed in such jurisdiction (which the parties acknowledge could mean severing the provision f rom this Agreement or, if allowed, enforcing it in a narrower form), without affecting the remainder of this Agreement, or any other application of such term or provision in such jurisdiction, or application of such term or provision in any other jurisdiction.
SAFETY INFORMATION
CAUTION!
! Internal battery voltage is 12V DC. ! The unit is intended for instal l ation in a controlled
environment (temperature controlled, indoor area free of conductive contami nants).
! All batteries used are Sealed Lead Batteries. Batteries must
be recycled.
RECYCLING INFORMATION
Your UPS contains a Non-spill Sealed Lead Battery. On the battery, you will find the battery name. Please reference the chart below for recycling informati on.
Battery Name Recycling Inside the
USA
BB Battery (800) 278-8599 N/A CSB Battery (800) 738-7372 1 (817) 244-4415 VISION Battery (973) 726-5323 N/A
CONTACT US
Belkin Components 501 West Walnut St. Compton • CA • 90220-5221 • USA Tel: 310.898.1100 • Fax: 310.898.1111
Belkin Components, Ltd Unit 13 • Gatelodge Close • Round Spinney Northampton • NN3 8RX • UK Tel: +44 (0) 1604678300 • Fax: +44 (0) 1604678330
Belkin Components B.V. Starparc Building Boeing Avenue 333 1119 PH Schiphol-Rijk The Netherlands Tel: +31 (0) 20 654 73 00 • Fax: +31 (0) 20 654 73 49
Belkin Australia Ltd 7 Bowen Cresent West Gosford, NSW 2250 Tel: +61 (02) 4325 4666 Fax: +61 (02) 4325 4277
Recycling Outside the USA
Loading...