INTRODUCTION
Thank you for purchasing a Belkin Uninterruptible Power Supply
(UPS). Each year, several natural and man made occurrences put
the power supplied to your electronics in your home or office in
jeopardy. At risk are your hardware, software and data because of
these power problems.
IMPORTANT SAFETY INSTRUCTIONS
Please save this manual!
It contains important operating instructions and warranty information
pertaining to your UPS.
Please save or recycle the packaging materials!
The UPS packaging was designed with great care to provide
protection during shipment and delivery. These materials are
invaluable if you ever have to return the UPS for service. Damage
sustained during transit is not covered under the warranty.
Federal Communications Commission Interference Statement
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. To assure continued
compliance, use only shielded interface cables when connecting to
computer or peripheral devices. Any changes or modifications not
expressly approved by the party responsible for compliance could
void the user’s authority to operate this equipment.
CONTENTS
You should have received the following:
1 – UPS unit
1 – Bulldog Plus Shutdown Software
1 – USB Cable
1 – Phone Line Cable
1 – Coaxial Cable (only F6B550-USB model).
SYSTEM REQUIREMENTS
The UPS can be used without the software and can be used with
any computer using up to a 17” CRT or LCD monitor. Also, you do
not have to have the software installed to utilize the battery backup
outlets.
To fully utilize the UPS and its software, your computer must be able
to operate the following operating systems: Windows98/ ME /NT4 /
2000 /2003 /XP and have a USB port.
UPS FEATURES AND FUNCTIONS
Before installation, please inspect the UPS upon receipt. Make sure
that nothing is damaged.
Your UPS features 3 LED indicators. Each is marked by a power icon;
please familiarize yourself with this chart, as it will assist you in the
use of your UPS. (See #4 on Diagram 1)
Indicator Condition Description
ON-LINE
*ON-BATTERY
*LOW-BATTERY
*REPLACE
BATTERY
*UPS Fault
SITE WIRING
FAULT
О Solid
Green
☼ Flashing
Yellow
О Solid
Yellow
О Solid
Red
The UPS is operating and
supplying the utility power to
connect loads.
When the UPS is operating from
battery:
1. The light is blinking every 10
seconds if the UPS is
operating on battery mode.
2. The light illuminates rapidly
every 1 second if the UPS’s
battery is very nearly
depleted.
When the UPS is operating and
supplying the utility power to
connect loads, the LED and
buzzer will flash and emit every
1minute if the UPS’s battery
needs to be replaced.
The LED will start continuously
and the buzzer will be beeping
for 10 seconds if UPS fault is
found.
The Site Wiring fault LED will
illuminate when one of the
following conditions exist:
1. Open or high resistance
ground
2. Hot and neutral polarities
reversal
○
R
F6H375-USB
F6H550-USB
F6B550-USB
TOP PANEL
#3
1.
SURGE Protected outlets (See #1 on Diagram 1)
These outlets do not provide power during a power outage.
Do not plug any surge protectors or power strips into the battery
back-up outlets (i.e. daisy chaining).
Equipment such as computer peripherals, printers, fax machine’s,
or a desk lamp may be plugged into these outlets. The On/Off
button does not control these outlets.
2. UPS Outlets (See #2 on Diagram 1)
These outlets are your battery back up outlets. We strongly
recommend that only sensitive equipment such as your computer
and monitor should be plugged into these outlets.
Caution ! Never connect a laser printer or scanner to the
backup outlets of UPS with other computer equipment. A
laser printer or scanner draws significantly more power when
in use than when sitting idle. This may overload the UPS.
Should a power outage occur, your battery backup would
automatically turn on Power (utility or battery) is not supplied to
these outlets when the UPS is switched off.
3. The On/Off button has 4 functions: (See #3 on Diagram 1)
1. Turns on the UPS. Depress button at least 2 seconds. The
green light will come on.
2. Cold start function. Assuming the battery is charged the UPS
will work without it being plugged into an outlet. Depress and
hold the key for at least 2 seconds to turn on the UPS.
3. Silence function. During “On Battery Mode”, the audible sound
can be turned “ON” or “OFF” by depressing the switch less than
1.5 seconds.
4. Battery test function. During “ON Line Mode”, depressing the
switch less than 1.5 seconds and the UPS performs a battery
test in back up mode.
SIDE PANEL
#4
Diagram 1
#2
#1
Surge Protection Only
Battery Back-up + Surge Protection
#1
OUT
Refer to Bottom for
Cautionary Marking
#4
Circuit Breaker
Push to Reset
#5
Diagram 2
1. AC Input Power Cord (See #1 on Diagram 2)
Provides power to your UPS.
2. Audio/ Video surge protection port (see #2 on Diagram 2)
(Only F6B550-USB model)
The Audio/ Video cable is surge protected. There is one input port
and one output port.
3. Phone/ Fax/ Modem Surge Protection (See #3 on Diagram 2)
The Phone/ Fax/Modem lines are surge protected. There is one
input jack and two output jacks. This allows you to split one
telephone connection to two separate devices.
4. AC Breaker (Circuit Breaker; See #4 on Diagram 2)
Should a power overload occur, the circuit breaker would trigger
IN
AC Input
Phone/Fax/Modem Protection
OUT OUTIN
#2
#3
the UPS to turn off AC power. In order to restore the power,
Chart 1
depress the circuit breaker button to reset, then depress the
Power button.
BATTERY REPLACEMENT PROCEDURE
Replacement requires removing the battery cover plate on the back or bottom of the UPS. No tools are needed. To replace the batteries:
1. Remove the battery cover plate on the back of the UPS (Fig.1).
2. Disconnect the insulated connectors from the battery terminals (Fig.2) then put the battery wire into indentations.
3. Remove the battery then insert a new battery pack, and push the connectors onto the battery terminals (Fig. 3)
NOTE: There may be a small spark at the battery terminals when reconnecting the connectors. This is normal and will not harm you or the UPS.
Fig. 1 Fig. 2 Fig. 3 Fig. 4
5. USB communication port (see #5 on Diagram 2)
Your UPS features a USB communication port. Installation of the
cable and software is optional. This allows the UPS to connect to
your computer. The Bulldog Software will not work if the UPS is
not connected to you computer. This does not mean the battery
backup feature will not work without the software and cable
installed. The UPS will still provide backup power but you will be
unable to utilize the data management capabilities of the software.
4. Close the battery cover (Fig. 4).
ALARMS
BACK UP (Slow Alarm)
When in “BACK UP” on battery mode, the YELLOW LED
illuminates and the UPS emits an audible alarm. The alarm
stops when the UPS returns to ONLINE normal operation.
LOW BATTERY (Rapid Alarm)
In “BACK UP” mode, when the battery energy runs low, the
UPS beeps rapidly until the UPS shuts from a depleted battery
or returns to LINE NORMAL operation.
FAULT (10 Seconds Continuously)
When the UPS occur fault, the UPS emits an audible alarm for
10 seconds continuously to warn of a fault condition.
Disconnect the equipment prior to checking the equipment.
INSTALLATION
Note!
Before installation, please inspect the UPS Upon
receipt. Make sure that everything inside the package
is not damaged.
A) Connect to AC Utility Power
1. Connect the AC inlet to utility power via the
power cord. Please make sure there are no
devices plugged into the UPS unit. Check to
see if the “Site Wiring Fault” indicator is lit or
not. If it is lit, please have the utility wiring
inspected by an electrician.
B) Charge the Battery
1. For best results, charge the battery for 8 hours prior to initial
use. The UPS charges its battery whenever it is connected to
the utility power.
C) Turn on the UPS
1. Turn on your UPS by depressing the On/Off button for
approximately 2 seconds. You will see the green indicator light
come on.
D) Plug in Power Devices
1. Plug your devices into the AC outlets on the UPS. To use the
UPS as a master on/off switch, make sure all of the loads are
switched on.
Caution: Never connect a laser printer
or scanner to the backup outlets of UPS
with other computer equipment. A laser
printer or scanner draws significantly
more power when in use than when
idles. This may overload the UPS.
Laser Printer
E) Connect the phone/ fax/ modem lines
1. Connect a single phone / fax/ modem line into the surge
protected sockets on the side of the UPS. The RJ-11 modular
sockets accept standard single line telephone connections.
2. Plug one end of the phone cable you received into your
telephone wall jack and plug the other end into the jack marked
IN. You may now plug a phone, fax or modem into the two
jacks marked OUT. (See Diagram 3)
Phone/Fax/Modem Protection
OUT OUTIN
Modem/ Fax
To Telephone Socket
Phone
Diagram 3
Note: This connection is optional but highly suggested as phone/
fax/ modem lines often carry dangerous surges and spikes. The
UPS works properly without a phone/ fax/ modem connection.
Caution: The phone/fax/modem protection feature could be rendered
inoperable if improperly installed. Make sure that the telephone line
from the wall is plugged into the connector marked “IN”, and the
devices to be protected (phone/ fax/ modem) are plugged into the
connector marked “ OUT”.
F) Connect the CATV cable (see #2 on Diagram 2)
(Only F6B550-USB model)
1. Connect a single CATV cable into the surge protect port on
the left of the UPS. The Audio/ Video modular port can
accept the standard single cable of CATV connects.
2. Plug one end of the CATV cable you received into your CATV
wall port and plug the other end into the port marked IN. You
can plug television into the one port marked OUT.
Note: The UPS works properly without the Audio/ Video connection.
G) Connect the USB (Universal Serial Port) Communication
port (see #5 on Diagram 2)
A USB port is provided to relay the signal to support Windows. To
fully utilize the Bulldog Shutdown Software; you will need to
connect the UPS to your computer. Connect the USB cable to
your UPS then connect the other end to the USB port on your
computer.
H) Install the Software (Optional)
a) To fully utilize the UPS and its software, your computer must be
able to operate the following operating systems: Windows98/
ME / NT4/ 2000/ 2003/ XP and have a USB port.
b) Your UPS features the Bulldog Plus Shutdown Software. This
allows you to protect and save your data should a power
outage occur, as well as safely shutdown your computer in your
absence. Please be sure to close out of all applications prior to
installing the software.
1. To install the software, please place the CD into the CD drive of
your computer.
2. Your computer should autorun the CD. If this does not occur, go
to the Run feature on your Start icon (lower left corner) on your
screen. Please enter the CD drive, it may be D: Upon entering
the drive run setup.exe. to execute the software. Should you
continue to have a problem, please refer to your computer’s
owner’s manual for the correct drive.
3. The “Welcome to the Belkin Bulldog Plus Product Installation
Browser” will appear. Please click Install and select the
Windows version.
4. The Bulldog Plus Installation window will appear. Please
choose the appropriate software to install
5. Install Shield Wizard will appear onscreen, click Next.
6. Please read the License Agreement and click Yes.
7 On Setup Type, ALL (Standalone) is the default. Standalone is
for UPS management for your computer only. Networking
management is for administrators who need to manage several
UPSes in a workstation environment. You should not install the
networking files unless you are technically qualified to use
these features. For more information on networking, please
refer to the software user’s manual.
8. On Choose Destination Folder, you have the option to choose
the location of where you would like the Software located on
your computer. We recommend using the default option as
shown on screen. To use the default option, click Next.
9. On Select Program Folder, you have the option to choose the
program folder for your Software. We recommend using the
default option as shown on screen. To use the default option,
click Next.
10. On the Select Language screen, please select your language
choice.
11. The software will now be installed. Once completed, please
click Finish.
Note!
Please refer to the help feature found on the Belkin On-line Screen.
To access this screen, please click the Belkin shield found in the
lower right corner on your task bar of your screen.
Once the Belkin On-line screen appears, choose help. The Bulldog
Online Help screen will appear. You may use the Contents, Index or
Search tabs to assist you with your help issues and to get more
information on the specific features and functions of the software.
I) User Manual Installation
You will need Adobe Acrobat Reader to review the User’s Manuals. If
you do not have the reader, please goto www.adobe.com to
download a free version of the software.
1. From the “Welcome to the Belkin Bulldog Plus Product
Installation Browser” window, locate and choose User Manual’s.
2. The “Bulldog Plus User Manuals” window will appear. Please
move your pointer to the manual you wish to open and click.
3. An Adobe PDF file will be opened. To save a copy to your hard
drive, you will need to goto “File” on your menu bar and choose
“Save a copy”.
4. On the Save a Copy window, please choose a destination folder
for the manual.
J) Uninstall for Windows 98/ Me/ NT4/ 2000/ 2003/ XP
There are two options to uninstall the Belkin Shutdown Software.
Option 1
1. Click the Start icon in the lower left hand corner of your screen
and goto the Programs folder. Scroll to the Belkin Bulldog Plus
folder and choose setup. Install Wizard will appear.
2. Choose Remove and click Next.
3. The Program Files and Audio Files will be checked. If they are
not, please check them. Click Next. The uninstall procedure
will begin.
4. Click Finish when complete.
Option 2
(Note: Windows2000/ 2003/ XP users choose the Control
panel function from your Start icon and then goto to step 2.)
1. Click the Start icon in the lower left hand corner of your screen
and goto the Settings icon. Goto and choose the Control Panel
folder. The Control Panel window will appear.
2. Locate and click the Add/Remove Programs icon. The
Add/Remove Programs window will appear.
3. Locate and choose the Belkin Bulldog Plus software. Click the
Change/Remove button on the right. Install Wizard will appear.
4. Choose Remove and click Next.
5. The Program Files & Audio Files will be checked. If they are
not, please check them. Click Next. The uninstall procedure
will begin.
6. Click Finish when complete.
STORAGE
Storage Conditions
Store the UPS covered and upright in a cool, dry location with its
battery fully charged. Before storing, charge the UPS for at least 6
hours.
Extended Storage
During extended storage in environments where the ambient
temperature is +5
months. During extended storage in environments where the
ambient temperature is +86
o
F to +86 oF, charge the UPS battery every 6
o
F to +113 oF, charge the UPS battery
every 3 months.
Note:
Away from sunlight Away from heat Away from water
TECHNICAL SPECIFICATIONS
Input
Output
Model
Rated capacity
F6H375
-USB
375VA
/200W
Rated voltage 105-136Vac
Phase /
frequency
Voltage Step wave
Frequency 60Hz
F6H550
-USB
550VA/300W
Single phase 60Hz
F6B550
-USB
Desktop
Battery
Back up time
computer
+15” monitor
Desktop computer +17”
monitor≧13min
≧10min
Recharge time ≦ 16 hours to 90%
Environment
Temperature 0~35℃
Humidity 10~90%
Safety UL1778 / c-UL
Safety
Regulation
Appearance
EMI FCC Class B
EMS
Dimension
(W * H * D)
Net weight
IEEE C62.41 category A/ IEC1000-4-5
Level2
4.69 x 3.54 x 14.33 inches
(119 x 90 x 364mm)
4.3kgs/
9.47lbs
5kgs/ 11.01lbs
All specifications are subject to change without prior notice.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
• Power LED is
On/ Off button not
pushed or pushed
less than 2 second
Press the On/Off button
more than 2 second
not lit
Battery voltage is too
low
Recharge the UPS at
least 8 hours
• UPS will not
power on
UPS fault
Contact Belkin
Technical support at
techsupp@belkin.com
Power cord loose Re-plug the power cord
• UPS always
on battery
mode
• Back up time
is very short
AC breaker is tripped Reset the breaker
Power disturbances
have occurred
Battery is not fully
charged
UPS is overloaded
Normal operations
Recharge the UPS for a
minimum of 8 hours
Remove un-necessary
power loads (devices)
Contact Belkin
UPS fault
Technical support at
techsupp@belkin.com
BELKIN COMPONENTS USER LICENSE AGREEMENT
Belkin Components (Belkin”) thanks you for choosing one of our
products for your use. This User License Agreement (Agreement”)
contains the terms and conditions under which limited use of the
product is licensed to you.
PLEASE READ THIS NOTICE CAREFULLY
DO NOT USE THE SOFTWARE OR PRODUCT UNTIL YOU HAVE
READ AND AGREED TO THIS AGREEMENT. IF YOU USE THE
SOFTWARE AND PRODUCT, YOU ARE AGREEING TO THE TERMS
AND CONDITIONS SET OUT IN
THIS AGREEMENT. IF YOU DO NOT ACCEPT THESE TERMS AND
CONDITIONS, YOU MUST RETURN THE UNOPENED PRODUCT
WITH THE DISKS INSIDE TO THE PARTY FROM WHOM YOU
RECEIVED IT.
SCOPE OF USE: In this Agreement, software means all
machine-readable software programs and associated files in this
package,
All modified versions of and upgrades or improvements to such
programs and all copies of such programs and files. You, a single
user opening this envelope (You or our), may use the software on a
single central processing unit. You may not rent it, loan it out, or lease it,
nor use it on a multi-user system.
LICENSE: You have the non-exclusive right to use the software.
You are not permitted to copy, modify or transfer the software or
documentation. You may not compile, disassemble or otherwise
reverse engineer, break down, analyze or modify the software.
USE AND RESTRICTIONS: You are permitted to make backup copies
of all the software disks for archival purposes only. You must reproduce
the proprietary notice set forth on the disks and affix them to all backup
copies. You are not permitted to use these programs in connection with
a computer service, or to use the backup copies other than as a
replacement for the original copy.
TERM: This license is effective upon acceptance by opening this
envelope or in any other way using the enclosed software, which will
constitute your acceptance of, and agreement to, this Agreement, and
is effective until terminated. The limited license in this Agreement will be
automatically terminated if you fail to comply with any of the Terms and
conditions in this Agreement. You agree that upon such termination you
will immediately destroy all programs and documentation, including all
copies made or obtained by you.
SOFTWARE, PROGRAM, DOCUMENTATION, AND ANY RELATED
INFORMATION, GOODS OR SERVICES ARE PROVIDED WITH NO
WARRANTY OR REPRESENTATION OF ANY KIND WHAT SO EVER.
BELKIN HEREBY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
The entire risk of the use, results and performance of the software,
program and documentation is borne by you. Should any or all of the
product, software, program, documentation, or related information,
goods or services be defective, misused, unsuitable or cause or give
rise to any harm or liability whatsoever, you, not Belkin or its associates,
dealers or agents, assume the entire liability, cost of repair,
correction or any payment or other remedy whatsoever.
Furthermore, no warranty or guarantee is made regarding the use or
results of the product, software, program, documentation, or any
related information, goods or services in terms of correctness,
accuracy, reliability, timeliness or otherwise. You use and rely on
the program at your own risk. The following is the only and exclusive
warranty and remedy of any kind: Belkin does warrant that the
program disks are free from physical defects in materials and
workmanship under normal use for a period of one (1) year from the
date of purchase, as evidenced by a copy of the sales receipt.
Return the defective disk or documentation with your receipt directly
to Belkin for a replacement.
DISCLAIMER: Belkin or its associates will in no event be liable (i)
in any amount for lost profits or special, incidental, punitive or
consequential damages, or (ii) for any claim or damage of any
nature, or under any theory, whatsoever, in any amount in excess of
the purchase price you paid for the product. The warranties and
remedies here set forth are exclusive, and in lieu of all others oral or
written, express or implied. Some jurisdictions do not allow
exclusion or limitation of implied warranties or of liability for
incidental damages, so the foregoing limitations or exclusion may
not apply to you. This warranty gives you specific legal rights,
which vary from jurisdiction to jurisdiction.
HOWEVER, YOU WAIVE SUCH RIGHTS, EXCEPT AS
EXPRESSLY PROVIDED UNDER THE TERMS AND
CONDITIONS HAVE THIS AGREEMENT, TO THE MAXIMUM
EXTENT ALLOWED BY LAW.
The license is governed by the laws prevailing in the State of New
York, without regard to its conflicts of laws principles.
ACKNOWLEDGMENT:
By opening the package on which this Agreement is printed, or
through which it is visible, you acknowledge that you have read this
Agreement, understand it, and agree that this agreement is the
complete and exclusive statement of agreement between yourself
and Belkin and supersedes any prior agreements, oral or written,
and any other communications relating to the subject matter of this
Agreement.
SEVERABILITY:
Any term or provision of this Agreement or any application thereof,
which may be prohibited or unenforceable by law in a particular
jurisdiction, shall be interpreted and enforced to the maximum
extent allowed in such jurisdiction (which the parties acknowledge
could mean severing the provision from this Agreement or, if
allowed, enforcing it in a narrower form), without affecting the
remainder of this Agreement, or any other application of such term
or provision in such jurisdiction, or application of such term or
provision in any other jurisdiction.
SAFETY INFORMATION
CAUTION!
Internal battery voltage is 12V DC.
The unit is intended for installation in a controlled
environment (temperature controlled, indoor area free of
conductive contaminants).
All batteries used are Sealed Lead Batteries. Batteries must
be recycled.
RECYCLING INFORMATION
Your UPS contains a Non-spill Sealed Lead Battery. On the battery,
you will find the battery name. Please reference the chart below for
recycling information.
Battery Name Recycling Inside the
USA
Recycling
Outside the USA
BB Battery (800) 278-8599 N/A
CSB Battery (800) 738-7372 1 (817) 244-4415
VISION Battery (973) 726-5323 N/A
RITAR Battery (888) 841-5179 N/A
CONTACT US
Belkin Components
501 West Walnut St.
Compton • CA • 90220-5221 •
USA
Tel:310.898.1100
Fax: 310.898.1111
Belkin Components B.V.
Starparc Building
Boeing Avenue 333
1119 PH Schiphol-Rijk
The Netherlands
Tel: +31 (0) 20 654 73 00
Belkin Components, Ltd
Unit 13 • Gatelodge Close •
Round Spinney
Northampton • NN3 8RX • UK
Tel: +44 (0) 1604678300
Fax: +44 (0) 1604678330
Belkin Australia Ltd
7 Bowen Cresent
West Gosford, NSW 2250
Tel: +61 (02) 4325 4666
Fax: +61 (02) 4325 4277
Fax: +31 (0) 20 654 73 49
© 2003 Belkin Components. All rights reserved. All trade names are registered trademarks of respective manufacturers listed.
P/N: 5011320400