Belkin F6H500ukUNV, F6H350ukUNV, F6H650ukUNV User Manual

INTRODUCTION
Thank you for purchasing a SurgeMaster Battery Backup by Belkin. Each year, several natural and man-made occurrences put the power supplied to your electronics in your home or offi ce in jeopardy. At risk are your hardware, software, and data because of these power problems.
This product is designed to provide clean power to all computer systems and peripherals with maximum protection. It integrates quality surge protection and battery backup capabilities to provide complete power protection for your computer, modem, hard drive, and other related equipment. This product will safeguard against power disturbances of all kinds; blackouts, surges, spikes and line noise contamination.
IMPORTANT SAFETY INSTRUCTIONS
Please save this manual!
It contains important operating instructions and warranty information pertaining to your UPS.
NOTE:
During the installation of this equipment, it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA.
Please save or recycle the packaging materials !
The UPS packaging was designed with great care to provide protection during shipment and delivery. These materials are invaluable if you ever have to return the UPS for service. Damage sustained during transit is not covered under the warranty.
CONTENTS
You should have received the following: 1 – Battery Backup Product 1 – Shutdown Software CD w/Software Manual 1 – Users Manual (Multilanguage) CD 1 – USB Cable 1 – Serial Cable 1 – Phone Line Cable
UPS FEATURES AND FUNCTIONS
Before installation, please inspect the UPS upon receipt. Make sure that nothing is damaged.
Your UPS features 4 LED indicators that specify certain functions on your UPS. Please review this chart and it will assist you in the use of your battery backup.
ALARMS
Battery BACKUP (Slow Alarm)
When in the UPS is in battery backup mode, the On Battery (Yellow LED) illuminates and the UPS sounds an audible alarm every 10 seconds. The alarm stops when the UPS returns to normal ONLINE operation.
Low Battery (Rapid Alarm)
When the UPS is in battery backup mode and the battery energy begins to run low, the UPS will beep every 1 second until it shuts down from a depleted battery or returns to ONLINE normal operation.
USERS MANUAL
BELKIN SUPERIOR SERIES UPS
F6H350ukUNV F6H500ukUNV F6H650ukUNV
P74778uk
ALARMS ( cont.)
OVERLOAD (Continuous Alarm )
When the UPS is overloaded (the connected loads exceed the maximum rated capacity), the UPS emits a continuous alarm to warn of an overload condition. Disconnect nonessential equipment from the UPS to eliminate the overload.
REAR PANEL
INTERNET/PHONE/FAX/DSL/NETWORK PROTECTION
The Internet/phone/fax/DSL/network lines are surge­protected and provide complete safety for line connection.
ON/OFF Master Switch
(“I” means ON; “O” means OFF)
INTERFACE PORTS
The UPS provides both a USB and RS232 port for you use with your computer.
NOTE: Choose one port only.
BATTERY BACKUP OUTLETS
Only data-sensitive equipment such as a computer, monitor, and external drive should be plugged into these outlets. Battery power is automatically provided in case of a power outage. Power (AC or battery) is not supplied to these outlets when the UPS is switched off. (Do not plug surge protectors or power strips into the battery backup outlets).
SURGE-ONLY PROTECTED OUTLETS
Equipment such as a printer, fax machine, scanner, or a desk lamp can be plugged into these outlets. These outlets do not provide power during a power outage. These outlets are always on (when AC power is available) and are not controlled by the front panel switch.
AC INPUT BREAKER ( CIRCUIT BREAKER)
The 10-amp resettable circuit breaker button will be triggered if an overload condition forces the UPS to disconnect itself from utility power. If the black button sticks out, disconnect nonessential equipment and depress breaker.
SYSTEM REQUIREMENTS
The UPS can be used without the software and can be used with any computer using a monitor or a fl at-panel screen. Also, you do not have to have the software installed to utilize the battery backup outlets.
To fully utilize the UPS and its software, your computer must be able to operate the following operating systems: Windows
®
95, 98, 98SE, ME, NT® 4, 2000, XP, or
Linux
®
and higher and have a serial or USB port.
INSTALLATION
Note!
Before installation, please inspect the UPS upon receipt. Make sure that the UPS is not damaged.
Connect to AC Utility Power
Connect the AC inlet to utility power via the power cord.
Charging the Battery
For best results, charge the battery for 6 hours prior to initial use. The UPS charges its battery whenever it is connected to the utility power. Should you see the yellow check battery light come on, the battery may need immediate replacement.
Plug-In Power Devices
Plug your devices into the AC outlets on the top of the UPS. To use the UPS as a master on/off switch, make sure all of the loads are switched on.
Caution: Never connect a laser printer or scanner to the backup outlets of the UPS with other computer equipment. A laser printer or scanner draws signifi cantly more power when in use than when idle. This may overload the UPS.
Turning on the UPS
The UPS will perform a self-test each time the UPS is switched on that determines whether the battery can support the connected loads.
Note! The UPS maintains the battery charge when in the off position and will respond to commands received through the computer interface port.
To Conduct a Self-Test
Use the self-test to verify both the operation of the UPS and the condition of the battery. In normal utility power, recycle the power switch On/Off. During the self-test, the UPS operates in backup mode.
Note! During the self-test, the UPS briefl y operates on-batter y backup power (the green Power LED comes on and the unit emits a beep every 10 seconds). If the UPS passes the self-test, it returns to online operation. If the UPS fails the self-test, it immediately returns to online operation. See details regarding the Check Battery Indicator below in the next section.
Check Battery Indicator
This indicator is lighted when the unit has detected a weak or worn-out battery during the self­test. Please follow the procedure below to bring the battery up to normal operating levels:
1. Allow unit to charge for at least 12 hours
2. Re-test the battery by recycling the power switch off/on. The unit will run a 2-second self-test again to determine the strength of the battery.
3. If the Check Battery Indicated is lighted again, contact Belkin to replace the battery.
To Silence Audible Alarm
While in battery backup mode, push On/Off/ Test button less than 2 seconds to silence the audible alarm. (This does not work if the UPS is under LOW BATTERY or OVERLOAD condition.)
All equipment must be turned off prior to hardware installation.
PHONE/FA X/MODEM PROTECTION
Connect a single Internet, phone or fax line into the surge­protected ports on the back of the UPS. This comes with a built-in line splitter to provide you with 2 output lines. The RJ11 modular sockets accept standard, single-line telephone connections. The connection will require another length of telephone cable, which is included FREE with your purchase.
Phone-Line Connection with Built-In Splitter:
Note! This connection is optional but highly suggested as Internet, phone, fax lines often carry dangerous surges and spikes and need to be protected. The UPS will still work properly without a phone/fax/modem connection.
Caution! The phone/fax/modem protection feature could be rendered inoperable if improperly installed. Make sure that the telephone line from the wall is plugged into the connector marked “IN”, and the device to be protected is plugged into the connector marked “OUT”.
Serial or USB Communication Port (Installation Optional)
To fully utilize the Shutdown Software; you will need to connect the UPS to your computer so they can communicate to each other.
The communication port will provide the following features:
1. Monitoring charger status
2. Monitoring UPS status
3. Monitoring battery status and condition
4. Monitoring the utility status
5. Use the ON/OFF/TEST UPS power switch function to schedule UPS for power saving
You may connect the UPS to your computer by choosing either the serial or USB ports with the selector.
Note: Choose one port only. Do not connect your computer through both ports.
Indicator Condition Meaning
POWER ON
(Green LED)
Solid Green AC Power is on
Flashing Green
every 10 seconds
Batter y Backup is on
CHECK
BATTERY
(Yellow LED)
Solid Yellow LED
with Audible
Alarm ( Beeping)
Indicator will test itself when unti turns on.
1. In a low-battery scenario, the check battery LED will stay lighted until the battery is charged to acceptable level.
2. If while under battery backup mode the battery becomes too low, the Power On LED will start fl ashing every 1 second, and the audible alarm will sound ever y 1 second.
FAULT/
*OVERLOAD
(Red LED)
Solid Red LED
with Audible
Alarm ( Beeping)
Illuminates when the AC load exceeds the normal range. During this condition, the LED will be lit continuously, and the unit will sound an audible alarm intermittently until condition is restored to normal.
PROTECTED
(Green LED)
Solid Green
Indicates that surge protection is working properly. If this indicator is not lit, you have lost your surge protection. Please consult your warranty information and contact Belkin Corporation.
P74778uk_F6H350_500_650.indd 1 7/7/05 3:44:37 pm
Using the Serial or USB cable (included with purchase), connect the desired cable to your UPS then connect the other end to the Serial or USB port on your computer.
Caution: Use only the Belkin-supplied UPS monitoring cables.
USB: HID Windows Setup Procedure
*For installation on other operating systems, please consult the software’s manual
Hardware Installation
1. Connect the Serial/USB cable to the bat tery backup’s communication port.
2. Connect the Serial /USB cable to the PC’s communication port.
3. Make sure the communication port selector on the back
of the batter y backup is either on “USB” or RS-232 (Ser ial). Only one communication port can be used. Do not connect both USB and Serial at the same time.
Soft ware Installation
1. Insert the Belkin Power Management Software CD to the CD-ROM. The software will display the installation menu, or your can select ‘run’ from windows start menu and execute ‘setup.exe’. Belkin Power Management Software fi les will be copied into the directory you appointed. When the software has been launched, the operating system will select the local language in the software for displaying. If there is no preferred language, the Software will default to use English inter face.
(Default:C:\Program Files\Belkin Power Management Software\)
2. After installation. For Windows 95/98, check if there is a ‘Rupsmon Daemon’ icon in task bar. For Windows NT, go to ‘control panel->service’ and check if ‘Rupsmon’ service has started
3. Click ‘Belkin Power Management Software’ for parameter settings.
4. Click ‘Select UPS’ to monitor local or remote UPS.
5. Click ‘Settings’ to set ‘Communication Type’ and ‘Select Comm Port’. If you see ‘Communication with UPS’ on the main screen, this means you have connected with UPS.
Uninstall Belkin Power Management Software
To uninstall the shutdown software and remove it from the system, please go to Windows start menu \ “Belkin Power Management Software Uninstall.”
TECHNICAL SPECIFICATIONS
All specifi cations are subject to change without prior notice.
STORAGE
Storage Conditions
Store the UPS covered and upright in a cool, dry location with its batter y fully charged. Before storing, charge the UPS for at least four hours. Disconnect any cables connected to the computer interface port to avoid unnecessary drainage of the battery.
Extended Storage
During extended storage in environments where the ambient temperature is +5 o F to +86 o F, charge the UPS batter y every six months. During extended storage in environments where the ambient temperature is +86 o F to +113 o F, charge the UPS battery every three months.
Note:
Away from sunlight Away from heat Away from water
Belkin Corporation User License Agreement
Belkin Corporation ( “Belkin”) thanks you for choosing one of our products. This User License Agreement (“Agreement”) contains the terms and conditions under which limited use of the product is licensed to you.
PLEASE READ THIS NOTICE CAREFULLY. DO NOT USE THE SOFTWARE OR PRODUCT UNTIL YOU HAVE READ AND AGREED TO THIS AGREEMENT. IF YOU USE THE SOFTWARE AND PRODUCT, YOU ARE AGREEING TO THE TERMS AND CONDITIONS SET OUT IN
THIS AGREEMENT. IF YOU DO NOT ACCEPT THESE TERMS AND CONDITIONS, YOU MUST RETURN THE UNOPENED PRODUCT WITH THE DISKS INSIDE TO THE PARTY FROM WHOM YOU RECEIVED IT.
SCOPE OF USE: In this Agreement, software means all machine-readable software programs and associated fi les in this package. All modifi ed versions of and upgrades or improvements to such programs and all copies of such programs and fi les. You, a single user opening this envelope ( You or Your), may use the software on a single central processing unit. You may not rent it, loan it out, or lease it, nor use it on a multi-user system.
LICENSE: You have the non-exclusive right to use the software. You are not permitted to copy, modify or transfer the software or documentation. You may not compile, disassemble or otherwise reverse engineer, breakdown, analyze or modify the software.
USE AND RESTRICTIONS: You are permitted to make backup copies of all the software disks for archival purposes only. You must reproduce the proprietary notice set forth on the disks and affi x them to all backup copies. You are not permitted to use these programs in connection with a computer service, or to use the backup copies other than as a replacement for the original copy.
TERM: This license is effective upon acceptance by opening this envelope or in any other way using the enclosed software, which will constitute your acceptance of, and agreement to, this Agreement, and is effective until terminated. The limited license in this Agreement will be automatically terminated if you fail to comply with any of the Terms and conditions in this Agreement. You agree that upon such termination you will immediately destroy all programs and documentation, including all copies made or obtained by you.
SOFTWARE, PROGRAM, DOCUMENTATION, AND ANY RELATED INFORMATION, GOODS OR SERVICES ARE PROVIDED WITH NO WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER. BELKIN HEREBY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The entire risk of the use, results and performance of the software, program and documentation is borne by you. Should any or all of the product, software, program, documentation, or related information, goods or services be defective, misused, unsuitable or cause or give rise to any harm or liability whatsoever, you, not Belkin or its associates, dealers or agents, assume the entire liability, cost of repair, correction or any payment or other remedy whatsoever. Furthermore, no warranty or guarantee is made regarding the use or results of the product, software, program, documentation, or any related information, goods or services in terms of correctness, accuracy, reliability, timeliness or otherwise. You use and rely on the program at your own risk. The following is the only and exclusive warranty and remedy of any kind: Belkin does warrant that the program disks are free from physical defects in materials and workmanship under normal use for a period of one (1) year from the date of purchase, as evidenced by a copy of the sales receipt. Return the defective disk or documentation with your receipt directly to Belkin for a replacement.
DISCLAIMER: Belkin or its associates will in no event be liable (i) in any amount for lost profi ts or special, incidental, punitive or consequential damages, or (ii) for any claim or damage of any nature, or under any theory, whatsoever, in any amount in excess of the purchase price you paid for the product. The warranties and remedies here set forth are exclusive, and in lieu of all others oral or written, express or implied. Some jurisdictions do not allow exclusion or limitation of implied warranties or of liability for incidental damages, so the foregoing limitations or exclusion may not apply to you. This warranty gives you specifi c legal rights, which vary from jurisdiction to jurisdiction.
HOWEVER, YOU WAIVE SUCH RIGHTS, EXCEPT AS EXPRESSLY PROVIDED UNDER THE TERMS AND CONDITIONS OF THIS AGREEMENT, TO THE MAXIMUM EXTENT ALLOWED BY LAW.
The license is governed by the laws prevailing in the State of New York, without regard to its confl icts of laws principles.
ACKNOWLEDGMENT:
By opening the package on which this Agreement is printed, or through which it is visible, you acknowledge that you have read this Agreement, understand it, and agree that this Agreement is the complete and exclusive statement of agreement between yourself and Belkin and supersedes any prior agreements, oral or written, and any other communications
relating to the subject matter of this Agreement.
SEVERABILITY:
Any term or provision of this Agreement or any application thereof, which may be prohibited or unenforceable by law in a particular jurisdiction, shall be interpreted and enforced to the maximum extent allowed in such jurisdiction (which the parties acknowledge could mean severing the provision from this Agreement or, if allowed, enforcing it in a narrower form), without affecting the remainder of this Agreement, or any other application of such term or provision in such jurisdiction, or application of such term or provision in any jurisdiction.
SAFETY INFORMATION
CAUTION!
• Internal battery voltage is 12V DC.
• The unit is intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants).
• All batteries used are sealed lead batteries. Batteries must be recycled.
Please visit belkin.com for battery replacement information.
Recycling Information
Your UPS contains a non-spillable, sealed lead battery. On the battery, you will fi nd the battery name. Please take the time to properly recycle the battery in a proper manor.
CONTACT BELKIN
To contact Belkin for any reason, please fi nd our international offi ce contact information below.
Belkin Corporation
501 West Walnut Street Compton, CA, 90220-5221, USA +1 310 898 1100 +1 310 898 1111 fax
Belkin Ltd.
Express Business Park Shipton Way, Rushden, NN10 6GL, United Kingdom +44 (0) 1933 35 2000 +44 (0) 1933 31 2000 fax
Belkin B.V.
Boeing Avenue 333 1119 PH Schiphol-Rijk, The Netherlands +31 (0) 20 654 7300 +31 (0) 20 654 7349 fax
Belkin GmbH
Hanebergstrasse 2 80637 Munich, Germany +49 (0) 89 143405 0 +49 (0) 89 143405 100 fax
Belkin SAS
5 Rue du Petit Robinson, 3ème étage 78350 Jouy en Josas, France +33 (0) 1 34 58 14 00 +33 (0) 1 39 46 62 89 fax
Belkin Nordic
Knarrarnäsgatan 7 164 40 Kista, Sweden +46 (0) 8 5229 1870 +46 (0) 8 5229 1874 fax
Belkin Ltd.
7 Bowen Cresent, West Gosford NSW 2250, Australia +61 (0) 2 4372 8600 +61 (0) 2 4372 8603 fax
Belkin Tech Support
Europe: 00 800 223 55 460 US: 877 736 5771
www.belkin.com
TROUBLE SHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
UPS not on,
LED not lit
On/Off/Test button not pushed or pushed less than 3 seconds
Press the On/Off /Test button for more than 3 seconds
Batter y voltage is too low
Recharge the UPS at least 12 hours
UPS fault
Contact Belkin Technical Support
UPS always on
battery mode
Power cord loose
Re-plug the power cord
AC breaker is burned out or tripped
Replace or reset the breaker
AC utility voltage is too high or too low, or blackout
Normal condition
Backup time
too short
Batter y not fully charged
Recharge the UPS at least 12 hours
UPS is overloaded
Check wattage of connected equipment and remove some unnecessary loads
Charger fault or other reason
Replace battery. Contact Belkin Technical Support
The UPS
continuously
beeps
Overload
Remove the non-critical loads
MODEL
F6H350ukUNV F6H500ukUNV F6H650ukUNV
INPUT
Capacity 350VA / 210W 500VA / 300W 650VA / 390W
Voltage
Range
220-250 VCA/ 10 A
Freque ncy 50 Hz (± 3 Hz)
OUTPUT
Voltage 230 VCA +/ - 6 %
Freque ncy
(on battery )
50 Hz (±1 Hz)
BATTERY
Backup
time
5-10 min. 7-12 m in. 10-15 min.
Under /Over
Voltage
Transfer to
Batte ry
165~276 VCA +/- 6 %
Typical
Recha rge
Time
12 hr. (charg e prior to u se)
SURGE
PROTECTION
Max. Spike
Amps /
Joule s
Max. Spike Ampe rage: 4 5,000 A mps / 1620 Joul es
Confo rman ce
Safet y Compl ies to Brit ish Safety Standards
PHYSICAL
Dimen sions (L X W X H )
363x141x90 mm 363x141x107 mm
Net Weig ht 4.89 kg 5.94 kg 6.16 kg