Belkin F1D108-OSD-1 User Manual

It
P73055 F1D108-OSD
The OmniView
PRO
User Manual
Guide de l’utilisateur de
PRO
OmniView
PRO
Benutzerhandbuch
OmniView™ PRO
Handleiding
Manuale utente
OmniView
PRO
Fr
De
Ne
En
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 1
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 2
En
Fr
De
Ne
It
Table of Contents
Français (Europe) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Deutsch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Nederlands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Italiano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 3
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 4
Thank you for purchasing the Belkin Components OmniView™PRO KVM switch. Controlling 8 PCs from one keyboard, mouse and monitor has never been easier!
The OmniView™PRO gives you the ultimate in control. Compatible with AT and PS/2 style computers, it is loaded with features such as On-Screen Display, Integrated Mouse Conversion Technology and separate DB25 daisy-chain ports. It has complete keyboard and mouse emulation for error-free boot-ups, plus Microsoft®IntelliMouse®support. The OmniView
PRO is also designed to handle the most demanding resolutions up to 1600 x 1200, without any noticeable degradation in image quality. Switching can be done through the advanced On-Screen Display Menu, convenient front-panel pushbutton, or keyboard "Hot" key commands. And if you wish to control a Macintosh®computer, simply add the Belkin MAC Adapter
for even more system control.
Introduction
• Allows a user to control eight computers from one keyboard, mouse and monitor
• On-Screen Display menu gives the user a visual interface to naming and selecting
computers
• Integrated Mouse Conversion Technology allows connection of AT-style computers that
have serial mouse ports while using a PS/2 mouse only at the console
• Keyboard and mouse emulation for error-free boot-ups
• Microsoft
®
IntelliMouse®support and emulation
• Up to 1600 x 1200 resolution support
• DB25 Daisy-Chain ports - allows control over as many as 128 computers through 16 banks
of OmniView™PRO units
• Supports both AT and PS/2 style keyboards (AT requires AT-PS/2 adapter)
• Supports VGA, SVGA and Multisync monitors
• Uses inexpensive and commonly found standard cables
• On-Screen Display, pushbutton or keyboard "Hot" key command switching
• AutoScan mode for even more convenience
• Audible feedback when switching
• Recalls CAPS LOCK, NUM LOCK and SCROLL LOCK keys' status for each
computer automatically
• Front-panel status LEDs
• Works with OmniView™PS/2 MAC Adapter
• No software required
• One year product warranty
Package Contents
OmniView™PRO 8-Port F1D108-OSD 12VDC, 1000mA power supply F1D108-PWR-UK This manual P73055 Registration card P72009 Two rackmount brackets Mounting screws
Features
En
1
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 1
2
Technical Specifications
Console Connectors:
Keyboard: 6 pin MiniDIN Mouse: 6 pin MiniDIN (for PS/2 mouse)
DB9 male (for spare serial mouse)
Monitor: HDDB15 female
Computer Port Connectors:
Keyboard: 6 pin MiniDIN Mouse: 6 pin MiniDIN (for PS/2 mouse)
DB9 male (for serial mouse)
Monitor: HDDB15 male
Dimensions:
Width: 444.5 mm Height: 63.5 mm Depth: 165.1 mm
Weight: 2.7 kg Operating Temp: 0~40 deg. C Storage Temp: -20 ~ 60 deg. C Humidity: 0~80% RH, non-condensing
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 2
En
Product Detail
FRONT PANEL
REAR PANEL
3
Current Active
Bank Display
Current Active
Port Displays
Bank Select/ Scan Button
Port Select Button
Power Switch
SLAVE INPUT DB25 Daisy-chain port
MASTER INPUT SLAVE OUTPUT
DB25 Daisy-chain port
DC power
jack
DIP
switches
Optional serial
mouse connector
CONSOLE
connectors
Keyboard connector
PS/2 mouse
connector
VGA monitor
connector
PC PORT connectors
Serial mouse
output
Keyboard output
PS/2 mouse output
VGA signal
output
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 3
4
Make sure you have the right cables!
The OmniView™SE requires cables to connect the eight computers you will be controlling. Below are the Belkin part numbers and their descriptions. We recommend purchasing Cable Kits based on the type of mouse port your computer uses. Cable kits have all the cables you need to connect one computer to the OmniView™SE:
PS/2 Cable Kit - A3X982
Includes:
2 x F2N036-06
1 x F2N025-06-T
AT Cable Kit - A3X939
Includes:
1 x F3A510-06
1 x F2N025-06-T
1 x F2N209-06-T
1 x F2N017
(see below for descriptions of each)
Individual Cables and Adapters:
• PS/2 cable for keyboard and mouse ports 6 pin MiniDIN male/male
Part# F2N036-XX
• Standard VGA cable for monitor port HDDB15 male/female with thumbscrews
Part# F2N025-XX-T
• Serial extension cable for serial mouse DB9 male/female with thumbscrews
Part# F2N209-XX-T
AT keyboard cable for AT-style keyboard port
5 pin DIN male/male
Part# F3A510-XX
• AT to PS/2 keyboard adapter 5 pin DIN female/6 pin MiniDIN male
Part# F2N017
Other Cables and Adapters:
• High-resolution/high-refresh rate VGA cable for monitor port HDDB15 male/female with thumbscrews
Part# A3H981-XX
• PS/2 to AT keyboard adapter - for use with a computer having an AT-style keyboard port 6 pin MiniDIN female/ 5 pin DIN male
Part# F2N018
NOTE: The "XX" in the part number represents the length in feet.
6 pin MiniDIN
6 pin MiniDIN Female 5 pin DIN Male
HDDB15
List of Parts Needed
5 pin DIN
HDDB15
DB9
Daisy-Chain Cable
• DB25 Male/Male, 61cm with ferrite Part # F1D108-CBL
Optional 19" (48.3cm) Rackmount Kit
• 48.3cm, 1.5u high Part # F1D103
5 pin DIN Female
6 pin MiniDIN Male
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 4
En
Hardware Installation
5
Single-unit operation or Daisy-chained operation
The OmniView™PRO has the capability to be daisy-chained to 15 more units (for a total of
16), giving the user control over a maximum of 128 computers! Each OmniView™PRO unit is defined as a BANK. See diagram above for more information.
BANK numbers range from 0 to F (hexadecimal), for a total of 16 BANKs. BANK 0 is the MASTER bank, while banks 1 through F are slave banks. The MASTER bank is the unit that connects to the console keyboard, mouse, and monitor.
The DIP switches must be set correctly for proper identification and usage. See the next section for the actual settings. If you are using the OmniView
PRO in a single-unit configuration, it must be set as the MASTER (BANK 0). If it is to be used as a slave unit, then it must be set to any unused unique bank number from 1 through F.
CONSOLE
Keyboard,
mouse and
monitor
Bank 0 (Master)
Bank 1 (slave)
Bank 2 (slave)
etc...
Bank F (slave)
12345678
9 10111213141516
17 18 19 20 21 22 23 24
121 122 123 124 125 126 127 128
etc...
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 5
NOTE: "ON" is down
1. Set the DIP switches. If you have only one OmniView
PRO, use the MASTER bank setting. If the OmniView™PRO you are using will be daisy-chained off another unit, use a unique slave setting. Please refer to the previous section for more information.
Hardware Installation (continued)
6
PLEASE FOLLOW THIS INSTALLATION PROCEDURE EXACTLY. NOT DOING SO MAY RESULT IN KEYBOARD AND/OR MOUSE ERRORS, OR FAULTY OPERATION.
WARNING: Before attempting to connect anything to the OmniView™PRO or the computers, make sure everything is powered off. Plugging and unplugging cables may cause irreversible damage to your computers and the OmniView
PRO. Belkin Components will not be held responsible for damage caused.
BANK ADDRESS
2. Find a convenient place to put your OmniView
PRO. Its 48.3cm form factor makes it ideal for 48.3cm racks. When mounting to a rack, attach the included brackets to the sides of the OmniView
PRO. Take note of the length of your cables so that your computers,
OmniView
PRO, keyboard, mouse, and monitor are distanced properly.
DIP SWITCH #
3
45
6
ON
ON
ON
ON
OFF
ON ON
ON
ON
OFF ON
ON
OFF
OFF ON
ON
ON
ON OFF
ON
OFF
ON OFF
ON
ON
OFF OFF
ON
OFF
OFF OFF
ON
ON
ON ON
OFF
OFF
ON ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
BANK 0 MASTE R BANK 1 slave BANK 2 slave
BANK 3 slave BANK 4 slave BANK 5 slave
BANK 6 slave BANK 7 slave BANK 8 slave BANK 9 slave
BANK A slave BANK B slave BANK C slave
BANK D slave BANK E slave BANK F slave
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 6
En
Hardware Installation (continued)
7
4. Connect the keyboard and mouse to the OmniView
PRO. If you have an AT-style
keyboard, you will need an AT-PS/2 adapter (Belkin Part# F2N017).
5. Connect the first computer's VGA cable to the OmniView
PRO. Using the VGA cable (Belkin Part# F2N025-XX-T or A3H981-XX), connect the male end of the cable to the VGA port on the computer, and the female end on the PC1 VGA port at the back of OmniView™PRO.
PS/2 Style Keyboard
F2N025-XX-T
Back of OmniView
PRO
Back of OmniView
PRO
Back of PC
PS/2 Mouse
3. Connect the monitor to the OmniView
PRO. Using the attached cable, or the one included with your monitor, connect it to the HDDB15 female port on the back of the OmniView™PRO labeled with the monitor symbol at the CONSOLE section.
Back of OmniView™PRO
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 7
8
Hardware Installation (continued)
6. Connect the first computer's mouse cable to the OmniView
PRO. If using a PS/2 cable (Belkin Part# F2N036-XX), connect one end to the PS/2 mouse port on the computer, and the other end to the PC1 PS/2 mouse port on the back of the OmniView™. If using a serial mouse cable (Belkin Part# F2N209-XX-T), connect one end to a DB9 serial port on the computer, and the other end to the PC1 DB9 serial mouse port on the back of the OmniView™PRO.
F2N036-XX for PS/2 mouse
OR
F2N209-XX-T for serial mouse
Back of OmniView
PRO
Back of PC
7. Connect the first computer's keyboard cable to the OmniCube
. Using another PS/2 cable (Belkin Part# F2N036-XX), connect one end to the PS/2 keyboard port on the computer, and the other end to the PC1 keyboard port on the back of the OmniCube™. If your computer has an AT-style keyboard port, you will need a PS/2-AT keyboard adapter (Belkin Part# F2N018).
F2N036-XX
Back of OmniCube
Back of PC
8. Double check all of the connections. Make sure the keyboard and mouse cables go to the
correct ports.
9. Repeat steps 5-7 for the remainder of the computers.
10.Attach the power supply to the power supply connector at the back of the OmniView
PRO. Plug this into any available AC outlet. Flip the power switch on the front of the OmniView™PRO. You should see the LED for Port 1 on the front panel blink, and hear a beep. Power up your monitor.
11.You can now power up all your computers simultaneously. The first computer will show up
on the monitor. Check to see if the keyboard, mouse and monitor work.If this is okay, press the “SELECT” button and check the functionality of the other computers. If you find any errors, double-check all of the cable connections.
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 8
Hardware Installation (continued)
En
9
NOTE: Avoid pressing any keys on the keyboard or moving the mouse if the currently
selected port has a computer that is in the process of booting up. This may cause the computer to not detect, or initialize the keyboard or mouse drivers properly.
Daisy-Chaining the OmniView™PRO:
The OmniView™PRO can be daisy-chained with additional OmniView™PRO units through the DB25 daisy-chain ports. The F1D108-CBL daisy-chain cable is required (not included) for proper operation. Please refer to the example below. Here, four OmniView
PRO units are
cascaded together for control over 32 computers. Recall that a maximum of 16 OmniView
PRO units can be cascaded together for control over 128 computers. Recall that the DIP switches on the MASTER unit must be set to BANK 0, and the slave units set to a unique BANK (any from 1 through F). See the beginning of this section for more information on the DIP switch settings.
Cable 1
Cable 2
Cable 3
MASTER
(Bank 0)
slave
(Bank 1)
slave
(Bank 2)
slave
(Bank 3)
• After setting the DIP switches on the slave unit, connect the computers using the same procedure outlined in steps 5 to 9 in the previous section. DO NOT POWER UP THE COMPUTERS YET.
•Using the F1D108-CBL daisy-chain cable, connect one end to the "Master Input/ Slave Output" of the unit. Refer to the diagram above.
• If the previous unit is the MASTER, then the other end of the cable connects to the "Master Input/Slave Output" port of the MASTER (such as cable 1 in the diagram above).
• If the previous unit is a slave, then the other end goes to the "Slave Input" port of the previous slave unit (such as cables 2 and 3 in the diagram above).
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 9
10
• Upon connecting the daisy-chain cable to the previous unit, it should automatically power up if the previous unit is powered up. However, it is still recommended that the power supply be used with the slave unit. You will see the LED display on the front panel show the units bank address setting.
• RESET the MASTER unit by pressing the BANK/SCAN and CHANNEL buttons simultaneously. This is necessary for the MASTER unit to detect the newly added slave unit.
• Verify that the MASTER unit has detected the new slave by pressing the BANK/SCAN button. If it detected the new slave properly, the LED display on the MASTER will register the slave units bank address. If you have many slave units, you may have to press the BANK/SCAN button many times to cycle through all of the preexisting slave units before reaching the newly added unit.
• Now you can power up the computers connected to the newly added slave unit. After all the computers have booted up, you may need to RESET the MASTER unit again to detect the presence of powered computers on the new slave unit.
NOTE: The OmniView
PRO can also be daisy-chained to OmniView™SE units (F1D102 and F1D104 only). This gives the user more selection and flexibility. When doing this, it is desirable to have the OmniView™PRO as the MASTER unit because of the On-Screen Display (OSD) menu feature. Thus, all the units will benefit from the OSD control, even if the OmniView™SE does not have the OSD feature.
Hardware Installation (continued)
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 10
En
Usage
11
Keyboard Hot-Key commands:
You can also conveniently command the OmniView™PRO to switch ports through simple keyboard key sequences. To send commands to the OmniView™PRO, the SCROLL LOCK key must be pressed twice within 2 seconds. You will hear a beep for confirmation. Below are the different commands:
Switch to PREVIOUS ACTIVE port
(on the same BANK)
Switch to NEXT ACTIVE port
(on the same BANK)
Switch to the PREVIOUS BANK
(by default, selects first active port on that BANK)
Switch to the NEXT BANK
(by default, selects first active port on that BANK)
Directly switches to port Y on BANK X
X = {0 to F} hexadecimal, Y = {1 to 8}
You can switch directly to any port by giving the OmniView
PRO the BANK and PORT numbers. For instance, if you press SCROLL LOCK SCROLL LOCK [2] [5], the computer on PORT 5 of the OmniView™PRO set to BANK 2 will be selected. In the following diagram, that is PC # 21. Hence, if you only have one OmniView™PRO, the first key (X) must be "0".
Selecting which computer to operate can be done either by On-Screen Display, the CHANNEL button, or through keyboard hot-key commands. You will notice that after the OmniView™PRO switches to another computer, the mouse will be inoperative for about 1-2 seconds. This is normal operation and ensures that proper mouse synchronization is established.
The CHANNEL Button:
12345678
Pressing the CHANNEL button cycles you through all the ports, including inactive ports.
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 11
12
Usage (continued)
Enable AutoScan mode
In AutoScan mode, the OmniView
PRO remains on one port for a number of seconds, before
switching to the next. This time interval is set in the On-Screen Display menu.
NOTE: There is no mouse or keyboard control in this mode. This is necessary to prevent errors.
Otherwise, if the user is moving the mouse or using the keyboard when the OmniView
PRO switches to the next port, data flow is interrupted and will cause erratic mouse movement and/or the wrong characters to show up when using the keyboard.
To get out of AutoScan mode, press the SPACEBAR.
CONSOLE
Keyboard,
mouse and
monitor
Bank 0 (Master)
Bank 1 (slave)
Bank 2 (slave)
etc...
Bank F (slave)
12345678
9 10111213141516
17 18 19 20 21 22 23 24
121 122 123 124 125 126 127 128
AutoScan Mode:
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 12
En
Usage (continued)
13
On-Screen Display Menu Control:
Enable the On-Screen Display Menu
To get into the On-Screen Display (OSD) menu, press SCROLL LOCK, SCROLL LOCK, SPACEBAR. Immediately, the OSD overlay screen appears. This screen is generated by the OmniView™PRO, and does not affect your computers or running software in any way.
• You can navigate through the active ports by using the arrow keys. The OSD menu will
only allow you to move to active ports.
NOTE: If a computer is connected and is powered up, but the OSD menu does not display
a "", you will have to RESET the OmniView
PRO to re-detect the powered computers. This is done by simultaneously pressing the BANK/SCAN and CHANNEL buttons on the front panel.
• Pressing the INSERT key allows you to rename the port. Press ENTER to complete.
NOTE: Inadvertently pressing the SCROLL LOCK, SCROLL LOCK, DELETE keys will erase
any given names on the OSD menu.
• Pressing the ESC key exits the current screen.
• To view a different BANK, pressing the PAGE UP key goes to a previous BANK, while the PAGE DOWN key brings you to the next BANK.
• Once you have selected a computer on the menu, press ENTER to switch to that port.
• Pressing the TAB key opens up the Function menu. In this menu, you can select the SCAN TIME and the DISPLAY TIME.
The main OSD screen menu is shown on the right. It shows the currently selected BANK. If you have only one OmniView™PRO, it will say "BANK 0".
The current selected port is shown in RED.
A "" indicates that the computer connected to that port is powered up.
Belkin: F1D108-OSD
(TAB): FUNCTION / HELP
:PgUp :PgDn
1. WIN98
2. NT SERVER
3. MAC OS8
4. NET SRVR
5. UNIX SRVR
6. CHANNEL 6
7. CHANNEL 7
8. CHANNEL 8 BANK 0
Currently selected Port is in RED
Currently selected Bank Address
” indicates
PC is powered
NOTE: Pressing will reset the keyboard ports of the OmniView™Pro.
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 13
14
Usage (continued)
NOTE: If there are slave units present, the SCAN TIME and DISPLAY TIME settings are set on
the MASTER unit only, and need not be set on the slave units.
The BANK/SCAN Button:
Pressing the BANK/SCAN button cycles you through all the active BANKS (if there are slave units present) and then puts the unit in AutoScan mode. If the unit is a single MASTER unit, pressing the button immediately invokes AutoScan mode. This is evident by a long BEEP, followed by two short beeps.
SCAN TIME:
Amount of time the OmniView
PRO stays on one port before switching to the next port when in Scan Mode.
DISPLAY TIME:
Amount of time the OSD Menu or Port Name remains displayed on-screen after making a port selection.
[]: SELECT (INS): RENAME (Enter):COMPLETE (Esc): Exit
SCAN TIME:
7sec ■ 15sec 30sec 60sec
DISPLAY TIME:
7sec 15sec 30sec 60sec
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 14
En
Troubleshooting
15
General Problems:
Q: The OSD menu does not display a "" on a port where a computer is connected
and powered up. What do I do?
A: • RESET the OmniView™PRO by simultaneously pressing the “BANK/SCAN” and
CHANNEL buttons on the front panel. Access the OSD menu again and it should have re-detected all the active ports.
Q: When cascading, the MASTER unit does not see the slave unit(s). A: • Refer to the Hardware Installation section for information on how to properly connect
the daisy-chain cable.
• Make sure that the daisy-chain cable that you are using is the F1D108-CBL. Using any other cable will not guarantee proper operation or video quality.
• RESET the MASTER OmniView™PRO.
• Although a power supply is not necessary to make the slave unit work, try adding a power supply.
Monitor/Video Problems:
Q: I am getting ghosting, shadowing or fuzzy images on my monitor. What do I do? A: • Check the cables and make sure they are inserted properly.
• Your resolution and/or refresh rate is extremely high, or your cable is too long. Replace your VGA cables with coaxial, double-shielded cables such as Belkin A3H981-XX.
• Check to make sure that the power adapter is plugged in and is working properly. It must be 12VDC, 1000mA minimum. Make sure the power switch is on.
• Lower you refresh rate and/or screen resolution settings.
Keyboard Problems:
Q: The keyboard is not detected, or a keyboard error is reported during boot-up. A: • Check the cables and make sure they are inserted properly in the correct ports.
• Check to make sure that the power adapter is plugged in and is working properly. It must be 12VDC, 1000mA minimum. Make sure the power switch is on.
• RESET the OmniView™PRO by simultaneously pressing the “BANK/SCAN” and CHANNEL buttons on the front panel. Access the OSD menu again and it should have re-detected all the active ports.
• Do not press any keys on the keyboard while the selected computer is booting up. This is true for any PC, whether stand-alone or connected to a KVM switch.
Q: The computers boot up fine, but the keyboard does not work. A: • Check the cables and make sure they are inserted properly in the correct ports.
• Make sure the keyboard works when directly plugged into the computers.
• Try a different keyboard, but use only 101, 102 or 104-key keyboards.
• Make sure that the keyboard driver is for 101, 102 or 104-key keyboards, and not old XT keyboards.
• Check to make sure that the power adapter is plugged in and is working properly. It must be 12VDC, 1000mA minimum. Make sure the power switch is on.
• RESET the OmniView
PRO by simultaneously pressing the BANK/SCAN and CHANNEL buttons on the front panel. Access the OSD menu again and it should have re-detected all the active ports.
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 15
16
Troubleshooting (continued)
PS/2 Mouse Problems at the console or computers:
Q: The mouse is not detected during boot-up. A: • Check the cables and make sure they are inserted properly in the correct ports.
• Check your computer/motherboard documentation making sure that the PS/2 mouse port (or IRQ) is enabled.
• Make sure the mouse is directly plugged into the computer. Rebooting is necessary when trying this. If the computer still does not detect the mouse, then your computer’s PS/2 mouse port has a problem.
• RESET the OmniView
PRO by simultaneously pressing the BANK/SCAN and CHANNEL buttons on the front panel. Access the OSD menu again and it should have re-detected all the active ports.
Q: The computers boot up fine, but the mouse does not work. A: • Check the cables and make sure they are inserted properly in the correct ports.
• Make sure the mouse works when directly plugged into the computer. Rebooting is necessary when trying this. If the mouse pointer still does not move, then either your PS/2 mouse port or the mouse itself has a problem.
• Try a different mouse.
• Make sure the mouse is a true PS/2 mouse. A combo mouse will work just as long as it is set for PS/2 mode with the correct adapter. A serial-only mouse with a combo mouse adapter WILL NOT work.
• Check to make sure that the power adapter is plugged in and is working properly. It must be 12VDC, 1000mA minimum. Make sure the power switch is on.
• RESET the OmniView
PRO by simultaneously pressing the BANK/SCAN and CHANNEL buttons on the front panel. Access the OSD menu again and it should have re-detected all the active ports.
Q: When I switch from one port to another, mouse movement is completely erratic.
What do I do?
A: • RESET the OmniView™PRO by simultaneously pressing the BANK/SCAN and CHANNEL
buttons on the front panel. Access the OSD menu again and it should have re-detected all the active ports.
• Make sure you do not have more than one mouse driver. Make sure that the driver is either for a Standard PS/2 or Microsoft®-compatible PS/2 mouse. Try to obtain the latest version from your hardware manufacturer.
• If you are using a specialized mouse such as a cordless mouse, scrolling mouse or mice with more than 2 operational buttons, use generic PS/2 mouse drivers. Non-standard mice often use non-PS/2 proprietary mouse protocol.
• Make sure you do not have any mouse drivers loaded in your config.sys or autoexec.bat files.
• Avoid moving the mouse or pressing the mouse buttons when switching ports.
• Reset the mouse to resume proper mouse movement simply by unplugging the mouse from the front of the OmniView™PRO for about 2-3 seconds, and plugging it in again.
Problems with computers using the serial mouse output:
Note: The OmniView™PRO has Integrated Mouse Conversion Technology. This technology
converts the PS/2 mouse signals at the console to serial mouse signals. Windows®9x Control Panel System applet may not display that it has detected a mouse, but the Modem applet will show a serial mouse at a certain serial port.
Q: The computers boot up fine, but the mouse does not work. A: • Check the cables and make sure they are inserted properly in the correct ports.
• Check the cable and make sure that it is a straight-through DB9 male/female cable such as Belkin P/N F2N209-XX-T (XX is the length in feet).
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 16
• Check your computer/motherboard documentation making sure that the serial ports are enabled, and that there are no IRQ or base address conflicts with other serial ports or modems.
• Plug in a serial mouse directly to your computer, and reboot. If the mouse pointer still does not move, then there may be no serial mouse drivers installed, or the serial port on your computer may have other conflicts or problems.
• Try a different PS/2 mouse at the console.
• Make sure the mouse (at the console) is a true PS/2 mouse. A combo mouse will work just as long as it is set for PS/2 mode with the correct adapter. A serial-only mouse with a combo mouse adapter WILL NOT work.
• Check to make sure that the power adapter is plugged in and is working properly. It must be 12VDC, 1000mA minimum. Make sure the power switch is on.
• RESET the OmniView
PRO by simultaneously pressing the BANK/SCAN and CHANNEL buttons on the front panel. Access the OSD menu again and it should have re-detected all the active ports.
Q: When I switch from one port to another, mouse movement is completely erratic.
What do I do?
A: • RESET the OmniView™PRO by simultaneously pressing the BANK/SCAN and
CHANNEL buttons on the front panel. Access the OSD menu again and it should have re-detected all the active ports.
• Make sure you do not have more than one serial mouse driver loaded. Make sure that the driver is either for a Standard Serial or Microsoft®-compatible serial mouse.
• Avoid using a specialized mouse at the console such as a cordless mouse, scrolling mouse or mice with more than 2 operational buttons. Non-standard mice often use non-PS/2 proprietary mouse protocol.
• Make sure you do not have any other mouse drivers loaded in your config.sys or autoexec.bat files.
• Avoid moving the mouse or pressing the mouse buttons when switching ports.
• Reset the mouse to resume proper mouse movement simply by unplugging the mouse from the OmniView
PRO for about 2-3 seconds, and plugging it in again.
Q: The wheel on the IntelliMouse®does not work on my computer. Why? A: • The Integrated Mouse Conversion Technology converts only the standard PS/2 signals
which are the buttons and the x and y coordinate movement, but not the wheel movement or wheel button. This is because the wheel and wheel button data use non-PS/2 protocol.
Notea bout the Optional Serial Mouse port at the console: If you have tried all possible troubleshooting methods, you can plug in a serial mouse (as a second mouse) at the optional serial mouse input port. See the Product Detail Section for the diagram. This mouse will be directly connected to the serial mouse ports on the OmniView
PRO. Note that the serial mouse signals will not be converted to PS/2 mouse signals, so if you have other PCs using PS/2 mouse ports, you must keep the PS/2 mouse at the console. This serial mouse is a second mouse, and is active only when on a computer that uses the serial mouse output.
17
Troubleshooting (continued)
En
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 17
FCC Statement
DECLARATION OF CONFORMITY WITH FCC RULES FOR ELECTROMAGNETIC COMPATIBILITY
We, Belkin Components, of 501 West Walnut Street, Compton CA 90220, declare under our sole responsibility that the product:
F1D108-OSD to which this declaration relates: Complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CE Declaration of Conformity
We, Belkin Components, declare under our sole responsibility that the F1D108-OSD, to which this declaration relates, is in conformity with Generic Emissions Standard EN50081-1 and with Generic Immunity Standard EN50082-1 1992.
Belkin Components One Year Product Warranty
Belkin Components warrants this product against defects in materials and workmanship for one year. If a defect is discovered, Belkin will, at its option, repair or replace the product at no charge provided it is returned during the warranty period, with transportation charges prepaid, to the authorized Belkin dealer from whom you purchased the product. Proof of purchase may be required.
This warranty does not apply if the product has been damaged by accident, abuse, misuse, or misapplication; if the product has been modified without the written permission of Belkin; or if any Belkin serial number has been removed or defaced.
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE IN LIEU OF ALL OTHERS, WHETHER ORAL OR WRITTEN, EXPRESSED OR IMPLIED. BELKIN SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
No Belkin dealer, agent, or employee is authorized to make any modification, extension, or addition to this warranty. BELKIN IS NOT RESPONSIBLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM
ANY BREACH OF WARRANTY, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPROGRAMMING, OR REPRODUCING ANY PROGRAM OR DATA STORED IN OR USED WITH BELKIN PRODUCTS.
Some states do not allow the exclusion or limitation of incidental or consequential damages or exclusions of implied warranties, so the above limitations of exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
Information
Belkin Components B.V.
Diamantlaan 8 • 2132 WV
Hoofddorp • The Netherlands
Tel: +31 (0) 235698765
Fax: +31 (0) 235612694
Belkin Components, Ltd.
Unit 13 • Gatelodge Close • Round Spinney
Northampton • Northants • NN3 8RX • UK
Tel: +44 (0) 1604678300
Fax: +44 (0) 1604678330
belkin.com
Belkin Components
501 West Walnut Street
Compton • CA • 90220 • USA
Tel: 310.898.1100
Fax: 310.898.1111
© 2000 Belkin Components. All rights reserved. All trade names are registered trademarks of the respective manufacturers listed.
P73055/F1D108-OSD/EU/man.qxd 4/21/00 2:25 PM Page 18
Nous vous remercions d’avoir choisi le commutateur OmniView™PRO KVM de Belkin Components. Il n’a jamais été aussi facile de commander huit PC à partir d´un seul clavier, d´une seule souris et d´un seul moniteur !
L’OmniView
PRO constitue le fin du fin en matière de commande de PC. Compatible avec les ordinateurs AT et PS/2, il possède de nombreuses caractéristiques telles que le paramétrage à l’écran OSD (On-Screen Display), la technologie de conversion de souris intégrée et des ports DB25 de mise en cascade séparés. Il est doté d´une émulation souris et clavier complète pour des démarrages sans erreur et il supporte la souris Microsoft
®
IntelliMouse®. L´OmniView™PRO est également conçu pour gérer les résolutions les plus exigeantes allant jusqu’à 1600 x 1200, et ce sans dégradation visible de la qualité de l´image. La commutation peut s´effectuer grâce au menu évolué de paramétrage à l’écran, au bouton poussoir situé à l’avant de l´appareil, ou encore grâce aux raccourcis clavier. En outre, si vous souhaitez commander un ordinateur Macintosh
®
, il vous suffit d´ajouter
l´adaptateur MAC Adapter
de Belkin pour maîtriser encore mieux le système.
Introduction
• Permet à un utilisateur de commander huit ordinateurs à partir d´un seul clavier, d´une
seule souris et d´un seul moniteur
• Le menu de paramétrage à l’écran (OSD) donne à l’utilisateur une interface visuelle pour
nommer et sélectionner les ordinateurs
• La technologie de conversion de souris intégrée permet de raccorder des ordinateurs AT
dotés de ports souris à connexion série en n’utilisant une souris PS/2 qu’au niveau de la console
• Emulation souris et clavier pour des démarrages sans erreur
• Support de la souris Microsoft®IntelliMouse®et émulation
• Supporte des résolutions allant jusqu´à 1600 x 1200
• Ports DB25 de mise en cascade. Ils permettent de commander jusqu’à 128 ordinateurs par
le biais de 16 bancs d’OmniView
PRO
• Supporte tant les claviers AT que les claviers PS/2 (AT nécessite un adaptateur AT-PS/2)
• Supporte les moniteurs VGA, SVGA et Multisync
• Utilise des câbles standard bon marché et faciles à trouver
• Commutation par paramétrage à l’écran, bouton poussoir ou raccourci clavier
• Mode de balayage automatique garantissant une commodité accrue
• Signal sonore indiquant la commutation
• Rappelle automatiquement, pour chaque ordinateur, le statut des touches CAPS LOCK
(Verrouillage des majuscules), NUM LOCK (Verr Num) et SCROLL LOCK (Arrêt défil)
• Voyants DEL d’état (à l’avant de l’appareil)
• Fonctionne avec l’adaptateur MAC Adapter
pour OmniView™PS/2
• Aucun logiciel n’est requis
• Garantie produit un an
Caractéristiques
19
Fr
P73055/F1D108-OSD/f/man.qxd 4/21/00 2:31 PM Page 19
Loading...
+ 53 hidden pages