Beko Z4H194-07, Z4H194-09 Schematic

TV Service Manual
Service Manual
5. Ergänzung / Supplement 5
Chassis LE 37"
Netzteilplatten Power Supply Boards
Z4H.194-07 Z4H.195-09
Zusätzlich erforderliche Unterlagen für den Komplettservice Additionally required Service Documents for the Complete Service
Sicherheit
Safety
Materialnr./Part No.
720108000001
Materialnummer / Part Number 720100505500 Änderungen vorbehalten / Subject to alteration TCC 0508 HH • Prepared in Germany http://www.grundig.com
GRUNDIG Service Chassis LE 37"
Es gelten die Vorschriften und Sicherheitshinweise gemäß dem Service Manual "Sicherheit", Material­nummer 720108000001, sowie zusätzlich die eventu­ell abweichenden, landesspezifischen Vorschriften!
Inhaltsverzeichnis
Seite
Allgemeiner Teil ................................................ 2
Einführung ........................................................................................2
Allgemeine Hinweise
........................................................................2
Platinenabbildungen
und Schaltpläne ...........................................3…8
Netzteil Z4H.194-07..........................................................................3
Netzteil Z4H.195-09
..........................................................................6
Ersatzteillisten .................................................. 9
Allgemeiner Teil
The regulations and safety instructions shall be valid as provided by the "Safety" Service Manu­al, part number 720108000001, as well as the respective national deviations.
Table of Contents
Page
General Section ................................................ 2
Introduction .......................................................................................2
General Notes
..................................................................................2
Layout of the PCBs
and Circuit Diagrams ..................................3…8
Power Supply Z4H.194-07 ...............................................................3
Power Supply Z4H.195-09
...............................................................6
Spare Parts Lists .............................................. 9
General Section
Einführung
In dieser Service-Manual-Ergänzung ist die Netzteilplattenvariante Z4H.194-07/Z4H.195-09 dokumentiert. Diese Netzteile werden alter­nativ zu den Netzteilen UX7.195/UX7.194 verwendet.
Hinweis:
Grundlage für den Service sind folgende Service Manuals: – Service Manual Sicherheit, Materialnummer 720108000001 – Service Manual Chassis LE
sowie die gerätespezifischen Ergänzungen.
37", Materialnummer 720100505000
Allgemeine Hinweise
Vor dem Öffnen des Gehäuses den Netzstecker ziehen! Achtung: ESD-Vorschriften beachten Leitungsverlegung
Bevor Sie die Leitungen und insbesondere die Masseleitungen lösen, muss die Leitungsverlegung zu den einzelnen Baugruppen beachtet werden. Nach erfolgter Reparatur ist es notwendig, die Leitungsführung wieder in den werkseitigen Zustand zu versetzen um evtl. spätere Ausfälle oder Störungen zu vermeiden.
Durchführen von Messungen
Bei Messungen mit dem Oszilloskop an Halbleitern sollten Sie nur Tast­köpfe mit 10:1 - Teiler verwenden. Außerdem ist zu beachten, dass nach vorheriger Messung mit AC-Kopplung der Koppelkondensator des Oszilloskops aufgeladen sein kann. Durch die Entladung über das Messobjekt können Bauteile beschädigt werden.
Messwerte und Oszillogramme
Bei den in den Schaltplänen und Oszillogrammen angegebenen Messwerten handelt es sich um Näherungswerte!
Introduction
This Supplement of Service Manual describes the power supply variant Z4H.194-07/Z4H.195-09. These power supplies are alternately used instead of power supplies UX7.195/UX7.194.
Note:
Basic instructions for servicing are given in following Service Manuals: – Service Manual Safety, Part Number 720108000001 – Service Manual Chassis LE
well as the type specific supplements.
37", Part Number 720100505000 as
General Notes
Before opening the cabinet disconnect the mains plug! Attention: Observe the ESD safety regulations Wiring
Before disconnecting any leads and especially the earth connecting leads observe the way they are routed to the individual assemblies. On completion of the repairs the leads must be laid out as originally fitted at the factory to avoid later failures or disturbances.
Carrying out Measurements
When making measurements on semi-conductors with an oscilloscope, ensure that the test probe is set to 10:1 dividing factor. If the previous measurement was made on AC input, please note that the coupling capacitor in the oscilloscope will be charged. Discharge via the item being checked can damage the components.
Measured Values and Oscillograms
The measured values given in the circuit diagrams and oscillograms are approximates!
2
Platinenabbildungen und Schaltpläne / Layout of PCBs and Circuit Diagrams
30.01.2008
C1004
1UF 400V
R1001
1M ½W
D1001 KBU8JR1084
NTC SCK150R78AMSY
1 23
4
5
678
IC1001
MC33262
R1003
470K
R1004
470K
C1005
1N
C1007
100N
C1009
1U
C1010
R1011
C1008
1N
R1006
22K
R1007
1K 1W
C1006
100P
R1010
4K
7
T1001
2SK3936
R1009
0.1R 2W
R1008
100R
R1012
470K
R1013
470K
PFC
C1012
10N 1.5KV
1
X1002 2317-7S
STBY_IN3V4
10
122
1
TR1001
ACTIVE PFC COIL
S_GND
T1007
BC848B
VCC
R1051
1R
R1052
4K7
STBY
1
X1001 MAINS
FS1001 T 4A H 250V
VR1001
3 4
1
2
LF1001
C1001
470N 275V
C1002
470N 275V
C1052
4N7 4KV Y1
C1053
4N7 4KV Y1
34
12
LF1004
2x10mH CM
3 4
1
2
LF1003 2x4mH CM
C1061
470N 275V
C1058
4N7 4KV Y1
C1059
4N7 4KV Y1
S_GND_2
C1062
470N 275V X2
C1055
10U 25V
D1003
RHRP1560
C1048 150U 450V
VR1002 VR1003
J1001
S_GND_2
IC1009
H11A817C
T1006
BC848B
R1046
470R
R1047
5K1
S_GND
C1044
10N
STBY
3V4'
STBY_IN
S_GND
C1054
100N
T1008
S_GND
R1055
STBY_IN
3V4'
R1053 R1054
0R
1
X1005 396G1-V03
1
X1006 2317-3S
PFC VCC STBY
C1013
33N 630V
R1061 10K 3W
R1018
120R
VCC
IC1004
H11A817C
C1016
22N
S_GND
R1019 4K7
L1001
4U7
C1020
10N
3V4
R1020 820R
R1021
10K
R1022
4K7 %1
R1024
2K7 %1
R1023
10K
C1021
33N
S_GND
3V
4'
+B
3V4'
ZD1008 1N4748
R1016 5K1
R1062 1M
C1015
22U 25V
C1017
3 x 1000U 16V
C1018
680U 16V
D1005
MUR160
D1006 MUR160
D1007
MBRP3010N
IC1005
TLV431CLP
R1017
3R9
D1025
MUR160
C1063
22U 25V
ZD1009 1N4748
VR1004
SR471K10DS
R1060
0R
R1015 33K
R1059 1M
3 4
1 2
LF1002
C1066 C1067
ZD1011
1N4746
D1027
IMBD4148
R1002 NTC SCK150R78AMSY
+B
D1026
MUR160
C1019
22U 400V
R1049 1K2
R1014 4K7
R1005
7K5
8
2
4
3
1 5
6
7
TR1002
SMT_16W_TF T Stand- By
X1003 2317-3S
3V4
S_GND
C1068
22U 35V
ZD1012
8.2V
R1063
390K
R1064
390K
R1077 91K
R1078 22K
T1016 BC848B
R1079 22K
R1081 1R SMD
C1076
1C SMD
FB
B
B
123
4
567
8
IC1002
FSDM0265RN
R1080 390K
R1082
270K
R1083 1K
VCC-STB
T1015 BC858B
VCC-STB
FB
C1069
1U
3
V4
R1085 2K2
C1077
1uF
T1017
BC548C
L1011 15uH
L1012 15uH
Z4H195-09
J1019
R1086 XXX
R1087 220R
R1088
220R
R1089
220R
R1090
220R
S_GND
3V4
J1022 J1021
C1078
10nF
3 4
12
LF1005
2x60mH
R1093
220R
ZD1010
BZX55C9V1
H1 DELIK
H2 DELIK
H4 DELIKH3DELIK
8V/12 V
2 6,7,8
1
3
Vref
Intern al
Bias
SQQ
R
OSC
Vcc Vcc
I
delay
I
FB
V
SD
TSD
Vovp
Vcc
Vocp
SQQ
R
R
2.5R
Vcc g ood
Vcc
Drain
V
FB
GND
AOCP
Gate
driver
5
Vstr
I
start
Vcc g ood
V
BURL/VBURH
LEB
PWM
Soft sta rt
?
?
4
I
pk
Freq.
Modula tion
V
BURH
Vcc
I
B_PEAK
Burst
Norma l
FSDM0265RN
Voltage Feedback Input
Multiplier,
Latch, PWM, Timer,
&
Logic
Error Amp
Multiplier
Undervoltage
Lockout
2.5V
Reference
Zero Current Detector
5
8
6
7
4
3
2
1
Drive Output
Gnd
Zero Current Detect Input
Multiplier
Input
Compensation
V
CC
Current Sense Input
Overvoltage Comparator
+
1.08 V
ref
+
V
ref
Quickstart
MC33262
42
40
41
=
+
Netzteil / Power Supply - Z4H.195-09
GRUNDIG Service Chassis LE 37"
3
Loading...
+ 6 hidden pages