BEI Sensors Serial to Parallel Converter Module User Manual

Electronic Modules
Electronic Modules
Divide-By Module
Serial to Parallel Converter for Absolute Encoders
BEI Sensors
BEI Sensors
Features:
• SSI OR RS422 SELECTABLE ON BOARD
• TWO TRANSMISSION RATES TO ACCOMMODATE LONG
CABLE RUNS
• HIGH NOISE IMMUNITY
• CAN BE USED FOR SYSTEM TROUBLESHOOTING
• SAVES INSTALLATION COSTS
• COMPACT PACKAGE
BEI’
s serial-to-parallel converter module takes serial data from any it to a parallel output. This eliminates the high cost and noise susceptibility of long, parallel cable runs, enabling the simplicity of a serial output encoder and a low cost twisted pair cable to interface with a standard troubleshooting.
Serial input, either
SSI
or
RS-422
is easily selectable by a Format Select terminal directly on the board. In to signal the encoder to provide data. Data is received serially and converted to a parallel format. Clock frequency is selectable by a Speed Select terminal, again directly on the board. For
In
RS-422
mode, data is received asynchronously from the encoder and converted to a parallel format. Speed Select input is used to set the baud rate:
kBaud for most applications, up to
See the
BEI
specications for Serial Synchronous Interface (S3) and
The module accepts inputs from 5 to package is
105
mm wide, 78 mm high and only
100
feet or less, the
500
feet;
28 VDC
1.25 MH
115.2 kB
aud for shorter runs below
and provides three output options: V out = V in; V out =
45
mm high and mounts to standard
BEI
Serial Synchronous Interface (S3) or RS-
PLC
or controller. The bright
LED
indicators give visual status for deserialization, testing and
SSI
z mode can be used and for longer distances, up to
100
feet.
RS-422
for additional specications, data format information and timing diagrams.
5 V
; and V out = Open Collector. The compact
DIN
Rail,
EN 50 022, 35
mm X
422
Interface (S1) encoders and converts
mode, the on-board clock generates pulses
500
feet, a
200 kH
z rate is available.
19.2
DIN
rail
7.5
mm, included with the module.
Ordering Information:
Output BEI Model Number BEI Part Number
5 - 28 Volts EM-DR3-SP-5-TB-28V/V 60007-001
5 Volts EM-DR3-SP-5-TB-28V/5 60007-002
Open Collector EM-DR3-SP-5-TB-28V/OC 60007-003
Controller Side: Encoder Side:
Pin Description Notes
D14 thru
DVD Dat a Valid
FMT Format Select
SPD Speed Select
NOTE: On Format, Enable and Speed selects, internal 10KΩ pull-ups to Vs provide default
Logic HI
Parallel Data
D0
EN Output Enable
0V
Outputs
Supply
Common
For the SSI selection under pin FMT, data
is MSB justied.
For the RS422 selection under pin FMT,
data is LSB justied.
Logic LO = Data Valid
Logic HI = Data not valid (transitioning)
Logic HI (N/C) = SSI
Logic LO (0V) = RS422 (Asynchronous)
Logic HI (N/C) = Output active
Logic LO (0V) = Inactive (High Impedance)
SSI: Logic HI (N/C) = 1.25 MHz
Logic LO (0V) = 200kHz
RS422: Logic HI (N/C) = 19.2 kBaud
Logic LO (0V) = 115.2 kBaud
Logic LO available for format and speed selections
Pin Description Notes
0V
0V
Vs Supply Voltage Provide 5 to 28 volts supply.
D - Data minus Connect to Data – line from encoder
D + Data plus Connect to Data + line from encoder
CL - Clock minus
CL + Clock plus
DIR N/C Leave this disconnected
NOTE: LED indicators on key data and control lines (Logic HI = Red, Logic Lo = Green)
Supply
Common
Supply
Common
7230 Hollister Avenue Goleta, CA 93117
www.beisensors.com
Connect either 0V pin to power supply
common. This should be the same supply common as used on the encoder.
Connected internally – see note above
Connect to Clock - line from encoder (SSI
only). If using RS422, then N/C
Connect to Clock + line from encoder (SSI
only). If using RS422, then N/C