BEI Sensors Electronic Modules Data Sheet

Electronic Modules
Electronic Modules
Divide-By Module
Divide-By Module
The Divide-By Module option provides a method to divide the effective resolution and signal frequency of a quardrature output incremental encoder. The Divide By option is available with the BEI Optical Isolator and Broadcaster. The module receives quardrature counts from an incremental encoder and divides them by a predetermined integer value. The index
signal is passed through without modication. When combined with the Optical Isolator a
single encoder can be used to feed different control devices, synchronizing their outputs at different ratios. This can lower parts count and reduce overall system costs.
This module accepts single ended or differential inputs and divides the signal by a factory set number from 2 to 256. The resulting output signal is a reduced resolution of the input signal.
Ideal for use in machine retrotting and for applications where a different resolution output is needed from the same encoder source. When ordering, make sure to specify the divide-by
Specications
Power:
The optical isolator can accommodate standard operating voltages from 5 to 28 VDC. It should never be connected directly to AC power mains. The module draws approximately 75 mA and a green LED indicates the unit is powered. The optical isolator module does not provide power to the encoder. Any encoders used in conjunction with this module must be connected to their own power.
Signal:
Specifying an optical isolator module requires knowledge of three system parameters: the DC
supply voltage available in the system; the encoder output type (logic levels and driver type); and
the input signal specications of the receiving electronics.
Output Code Format From Encoders
Dual Channel in quadrature plus index and complements. Data lines are designated A, B, Z, A/, B/, Z/ at the module
Output Signal Type From Encoder
Differential line driver (Use Connection Instructions #1) Single ended line driver (Use Connection Instructions #2) Single ended open collector with pull-up resistors internal to encoder (Use Connection Instructions #3) Single ended, open collector (Use Connection Instructions #3)
Output Signal Voltage Level From Encoder
5 VDC (TTL, RS422 compatible, line driver) 12-15 VDC
24VDC
Frequency Response of Optical Isolator
1 MHz, maximum
Power Requirements For Optical Isolator
5-28 VDC ±5%, 75mA plus load current
Optical Isolator Output Options
28V/V Line Driver, 100mA source/sink, Vout = Vin 28V/5 Line Driver, 100mA source/sink, Vout = 5V (Derate output current to 50mA with supply
voltage > 12VDC)
28V/OC NPN Open Collector, 80mA sink
Protection Level
Supply lines protected against over voltage to 60 volts and reverse voltage
Tristate Outputs
Available as –S Special Feature
amount in the model number (see ordering options below).
BEI Sensors
BEI Sensors
Mechanical
Package dimensions are 114.4 mm high by 99 mm wide by 22.5 mm thick. The package
mounts to a DIN rail type EN 50 022 (35mm X 7.5mm). A length of DIN rail is supplied with each module. The module simply snaps directly to the DIN rail and is ready to use.
Divide By Module Ordering information FOR ASSISTANCE CALL 800-350-2727
SAMPLE: EM - DR1 - DB2 - 5 - 28V/V
EM DR1
TYPE:
EM = Electronic Module,
DIN Rail mount
PACKAGE STYLE:
DR1 = 114.5 mm x 99mm x 22.5 mm
DB TB
FUNCTION
DB = Divide By
DIVIDE BY FACTOR:
Integer Value from 2 to 256
5
OUTPUT VOLTAGE FROM
ENCODER
3=2.5-3.7 V Logic
5=3.7-6.8 V Logic 15 = 11-19V Logic = 24 = 19-29V Logic =
7230 Hollister Avenue Goleta, CA 93117
www.beisensors.com
OUTPUT TERMINATION:
TB = Terminal Block
VOLTAGE/OUTPUT:
28V/V:28 V maximum, Vout=Vin 28V/5:28V maximum, Vout=5V 28V/OC:28V maximum, Vout=Open Collector
Tel: 800-350-2727 Fax: 805-968-3154
Rev 3-18-14
Electronic Modules
Divide-By Module
Connection Instructions #1
Differential Line Driver
Encoder signals from 5 VDC to 24 VDC (must specify the voltage when ordering)
This is the preferred type of encoder output as it has the best noise immunity. Connect each encoder signal to its like optical isolator input (A to A, A/ to A/, etc).
BEI Sensors
Connection Instructions #2
Single Ended Line Driver
Encoder signals from 5 VDC to 24 VDC (must specify the voltage when ordering)
This is the preferred type of encoder output as it has the best noise immunity. Connect each encoder signal to its like optical isolator input (A to A, A/ to A/, etc).
7230 Hollister Avenue Goleta, CA 93117
www.beisensors.com
Tel: 800-350-2727 Fax: 805-968-3154
Rev 3-18-14
Loading...