BEI Sensors SAS
Espace Européen de l’Entreprise
9, rue de Copenhague
CAMX
B.P. 70044 Schiltigheim
F 67013 Strasbourg Cedex
Tél : +33 (0)3 88 20 80 80
Fax : +33 (0)3 88 20 87 87
Mail : info@beisensors.com
www.beisensors.com
Web :
ATEX ABSOLUTE SINGLE TURN PARALLEL ENCODER, CAMX RANGE
ATEX certified Explosion-proof encoders according to Directive 94/9/CE
Explosion-proof rotary encoders for
Robust design for heavy-duty applications
Application fields: explosive atmospheres except for firedamp mines
EC type examination certificate
Download from our website www.beisensors.com
LCIE 03 ATEX 6235
CE0081
II 2 G/D
Ex d IIC T6, T5 or T4
Ex tD A21 IP6X T80°C T95°C T100°C
hazardous environments gas & dust
CAMX_12 T3A connection (axial cable gland)
Material
Stainless steel option
Cover : aluminium
Body: aluminium
Shaft Stainless steel CEM EN 50081-1, EN 61000-6-2
Bearings 6001 serie Isolation 1 000 V eff
Maxiamal load
Axial : 50 N
Radial : 100 N
Shaft inertia
Torque
16.10-6 kg.m2
15.10-3 N.m
Permissible max.speed 9 000 min-1 Protection(EN 60529) IP 65
Continuous max. speed 6 000 min-1 Theoretical mechanical lifetime 109 turns (F
Shaft seal Viton 20 N / 30 N : 360 50 N / 100 N : 18 100 N / 200 N : 2,2
T
Temperature class for gas atmosphere Temperature class for dust atmosphere
amb
-20°C ≤ Ta ≤ +40°C T6 T80°C
-20°C ≤ Ta ≤ +55°C T5 T95°C
-20°C ≤ Ta ≤ +60°C T4 T100°C
Changes possible without further notice - Version 091118
Shock (EN60068-2-27) 500 m.s-2 (during 6ms)
Vibration (EN60068-2-6) 200 m.s-2 (10 … 1 000 Hz)
Weight
3,5kg aluminium body and cover
7,2kg stainless steel body and cover
Operating temperature Cf here-under table (encoder T°)
Storage temperature - 30... + 85 °C
axial
/ F
radial
)
BEI Sensors SAS
Espace Européen de l’Entreprise
CAMX
9, rue de Copenhague
B.P. 70044 Schiltigheim
F 67013 Strasbourg Cedex
Tél : +33 (0)3 88 20 80 80
Fax : +33 (0)3 88 20 87 87
Mail : info@beisensors.com
Web :
www.beisensors.com
ATEX ABSOLUTE SINGLE TURN PARALLEL ENCODER, CAMX RANGE
RACCORDEMENT
20 GN green
21 YE yellow
22 GY grey
23 OG orange
24 BU blue
25 RD red
26 BK black
27 VT violet
28 WH/BN white/brown
29 WH/GN white/green
210 WH/YE white/yellow
211 WH/BK white/black
212 WH/OG white/orange
- WH white
+ BN brown
Ground/body General shield
DIRECTION WH/RD blanc/rouge
10 bits encoder example : only MSB (D3 to D12) will be connected
DIRECTION entry :
- Code direction CW : connect White/Red with Brown
- Code direction CCW : connect White/Red with White
ORDERING CODE
Shaft
Parallel output :
POWER SUPPLY/ OUTPUT STAGES
5C5 ele
ctronic : Push-pull 11/30Vdc
er supply : 11 to 30Vdc
Pow
Consumption without load : 100mA max
Intensity per channel : Is = 20mA max
0 max (Is=20mA): V
1 min (Is=20mA): V
= 0,5Vdc
ol
= Vcc-3Vdc
oh
Protection against short circuits
Protection against inversion of polarity
5CN ele
ctronic : NPN CO 11 to 30Vdc
Power supply: 11 to 30Vdc
Consumption without load : 100mA max
Intensity per channel : Is = 20mA max
0 max (Is=20mA): V
= 1,25Vdc
ol
Protection against inversion of polarity
5C5, 5CN
Code Resolution Connection
Orientation
connection
CAMX
(aluminium)
CEMX
12 :12mm 5: 11 – 30Vdc
C5: Push-Pull 11-30Vdc
CN: NPNCO 11-30Vdc
(stainless steel)
Ex: CEMX _ 12 // 5 C5 G //
B : binaire
G : Gray
13
…
1
13 //
T3 : cable gland +
PVC cable
T3 A030
ASSEMBLY CAUTION
NEVER OPEN THE ENCODER
NEVER CONNECT/DISCONNECT UNDER POWER SUPPLY/IN PRESENCE OF DUSTS ATMOSPHERE
The customer obliges to take up and to use our products, according to our specifications and to the manners of the profession. Our
company would not be responsible for any defect resulting from a defective or erroneous assembly. From a use superior to the
standard, or in abnormal conditions. The breakdowns resultant of shocks, bad electric supply, put in low capacity or overcapacity of
the product, the environment of bad conditions (humidity, projection, dust, etc) cannot be imputed to us. The converter doesn’t
require any maintenance. Any encoder presenting a dysfunction will have to be the object of immediate return for control in our
facilities. The encoder mustn’t be open in any case (cable gland and/or cover)
An earth situated on the cover must be linked with the ground of the installation
Made in FRANCE
Changes possible without further notice - Version 091118
Ex. cable :
A030 : cable
3m axial