Beglec STAGE PAINTER 12 User Manual

TABLE OF CONTENTS
PRELIMINARY MANUAL
1. Safety Instruction
2. Technical Specification
4. How To Control The Unit
5. Troubleshooting
6. Fixture Cleaning
STAGE PAINTER 12
Preliminary User Guide
Official version will follow soon on:
WWW.BRITEQ-LIGHTING .COM
1-
1. Safety Instruction
PRELIMINARY MANUAL
Please read carefully the instruction, which includes important
WARNING
information about the installation, usage and maintenance.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer.
Please keep this User Guide for future consultation. If you sell the unit to another user, be
sure that they also receive this instruction booklet.
Unpack and check carefully there is no transportation damage before using the unit.Beforeoperating, ensurethat the voltage and frequencyof powersupply match the power
requirements of the unit.
It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
The unit is for indoor use only. Use only in a dry location.The unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
Disconnectmain power beforereplacement or servicing.Make sure there is no flammable materials close to the unit while operating as it is fire
hazard.
Use safety cable when fixes this unit.Maximum ambient temperature is TA: 40. Don’t operate it where the temperature is
higher than this.
In the event of serious operating problem, stop using the unit immediately. Never try to
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
Do not touch any wire during operation as high voltage might be causing electric shock.
Warning
For power supply,do not connectin series much more than 10 units, use another mains supply for next 10 units.
Installation
The unit should be mounted via its metal hole on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a 10 times weight of the unit.
2. Technical Specification
3/6/9/12/15 channels switchableAutomaticallyswitching between music trig and auto modeGreat built-in programs under Master/Slavemode trigged by musicIndividual control of each LED clusterSound sensitivity adjustable via the menuAuto-fading show with 3 different speedsSpecially designed stand for floor operationLCD display for easy addressingand setting
VoltageAC100-240V~50/ 60HzPower consumption: 40W
LED: 12 x 3W Tri-ColorBeam Angle:D30, D45, D60, D40x70Fuse: T 6.3ADimension: 387 x 207 x 95 mmWeight: 3.9 kgs
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
Do not open the unit within five minutes after switching off.The housing, the lenses must be replaced if they are visibly damaged.
2-
3-
3. How To Set The Unit
PRELIMINARY MANUAL
3.1 Control Panel
Display
To showthe various menus and the selected functions
LED
DMX On DMX input present MASTER On Master Mode SLAVE On Slave Mode SOUND Flashing Sound activation
Button
MENU To select the programmingfunctions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions
Microphone
Receive the sound to control the unit
Only for remote control
By connect to the 1/4’’ microphonejack to control the unit for Stand by, Function and Mode function.
Mains input
Connect to supply mains power.
Mains output
Connect to supply mains power for other units.
Fuse
For over current protection.
DMX input/output
For DMX512link, use 3/5-pin XLR plug cable to link the unit together.
Safety Ring
Keep the installation safe.
3.2 Main Function
To select any of the given functions, press the MENU button up to when the required one is showing on the display. Select the function by ENTER button and the display will blink. Use DOWN and UP button to change the mode. Once the required mode has been selected, Press ENTER button to store. Back to the main functions without any change press the MENU buttonor wait for 1 minute. Hold MENU button to exit menu mode, the unit will run the built-in program you selected At this time you can press UP and DOWN button to change show, the new show will effect immediately. If you change to show 1-8 or Auto Fade, you can press ENTER button to choose speed. The unit will run in the speed selected or it will run to the music.
The main functions are shown on the drawing:
DMX Address
Press the MENU button up to when the DMX Address is showing on the display. Press ENTER button and the display will blink. Use DOWN and UP buttonto change the DMX512 address. Once the address has been selected, press the ENTER button to store. Back to the main functions without any change press the MENU button (or wait for 1 minute to exit menu mode).
Channel Mode
Press the MENU button up to when the Channel Mode is showing on the display. Press ENTER button and the display will blink. Use DOWN and UP button to select
4-
5-
the 3 channels mode or 6 channels mode or 9 channels mode or 12 channels mode 15
PRELIMINARY MANUAL
channels mode. Once selected, press the ENTER button to store. Back to the main functions without any change press the MENU button (or wait for 1 minute to exit menu mode).
Show Mode Press the MENU button up to when the Show Mode is showing on the display. Press ENTER button, the display will blink. Press DOWN and UP button to select Show 0 (Auto
show), Show 1 or … or Show 8 or Auto Fade, once selected, press MENU button to store and back to the last menu, then the unit will run to music. If you choose Show 1-8 or Auto Fade, press the ENTER button to confirm, then you can press DOWN and UP button to select Speed 1 (slow speed) or Speed 2 (middle speed) or Speed 3 (fast speed), press ENTER button to store, the unit will run in the speed that selected. Back to the main
functions without any change press the MENU button or wait for 8 seconds.
Color Mode Press the MENU button up to when the Color Mode is showing on the display. Press ENTER button, the display will blink. Press DOWN and UP button to select Manu (manual
setting), Color 1 or … or Color 32, once selected, press MENU button to store. If you choose Maun, press the ENTER button to confirm, you can press DOWN and UP button to select Red or Green or Blue, press ENTER button to confirm and press DOWN and UP button to adjust the value, then press ENTER button to store. Back to the main functions
without any change press the MENU button or wait for 8 seconds.
Slave Mode Press the MENU button up to when the Slave Mode is showing on the display. Press ENTER button and the display will blink. Use DOWN and UP button to select the slave 1 or
slave 2 mode. Once selected, press the ENTER button to store. Back to the main functions without any change press the MENU button (or wait for 1 minute to exit menu mode).
Sound State Press the MENU button up to when the Sound State is showing on the display. Press ENTER button and the display will blink. Use DOWN and UP button to select the on (sound
control on) or off (sound controloff) mode. Once selected, press the ENTER button to store. Back to the main functions without any change press the MENU button (or wait for 1 minute
to exit menu mode).
Sound Sense Press the MENU button up to when the Sound Sense is showing on the display. Press ENTER button and the display will blink. Use DOWN and UP button to adjust the sound
6-
sensitively (1-100) of the unit. Once the value has been selected, press the ENTER button to store. Back to the main functions without any change press the MENU button (or wait for 1 minute to exit menu mode).
Black Out Press the MENU button up to when the Black Out is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to select the yes (yes
blackout) or no (no blackout)mode. Once selected, press the ENTER button to store. Back to the main functionswithoutany change press the MENU button (or wait for 1 minute to exit menu mode).
Back Light Press the MENU button up to when the Back Light is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to select the on (back
light on) or off (back light off 1 minute after auto show) mode. Once selected, press the ENTER button to store. Back to the main functions without any change press the MENU
button (or wait for 1 minute to exit menu mode).
Auto Test Press the MENU button up to when the Auto Test is showing on the display. Pressing ENTER button and the display will show Test… and the unit will run self-test by built-in program. To go back to the functions press the MENU button.
Manual Test Press the MENU button up to when the Manual Test is showing on the display. Press ENTER button and Red 1 will blink, use UP and DOWN button to choose Green 1 or Blue 1
or Red2 or or Blue 4 or Dimmer or Strobe, press ENTER button to enter, then press UP and Down button to adjustthe valueand press ENTER button to choosenext optional. Back to the main functions without any change pleasepress the MENU button.
White Balance Press the MENU button up to when the White Balance is showing on the display. Press ENTER button andthe r 255 will blink, press UP and Down button to adjust the value, press ENTER button to store and g 255 will blink on the display,press UP and Down button to
adjust the value, press ENTER button to store and b 255 will blink on the display, press UP and Down button to adjust the value, and press ENTER button to store. Back to the main functions without any change please press the MENU button.
Fan Speed Press the MENU button up to when the Fan Speed is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to select Auto Speed
7-
(When the temperature of the unit under 40℃, FAN stops; between 45℃~55℃, FAN runs at
PRELIMINARY MANUAL
half speed; above 60℃, FAN runs at full speed. The LEDs will be off if the temperature higher than 75) or High Speed, press ENTER button to store. To go back to the functions press theMENU button.
Fixture Temp Press the MENU button up to when the Fixture Temp is blinking on the display. Pressing ENTER button and the display will show the temperature of the unit. To go back to the
functions press the MENU button. Fixture Time Press the MENU button up to when the Fixture Time is blinking on the display. Pressing ENTER button and the display will show the number of working hours of the unit. Togo back to the functions press the MENU button. Firmware Version
Press the MENU button up to when the Firmware Version is blinking on the display. Pressing ENTER button and the display will show the version of software of the unit. To go back to the functions press the MENU button.
4. How To Control The Unit
You can operate the unit in three ways:
1. By master/slave built-in preprogramfunction
2. By easy controller
3. By universal DMXcontroller
4.2 Easy Controller
The easy remote control is used onlyin master/slavemode. By connecting to the 1/4” microphone jack of the first unit, you will find that the remote controller on the first unit will control all the other units for Standby, Function and Mode selection
Stand By Blackout the unit Function 1. Sync. Strobe
2. Async strobe
3. Sound Strobe
Mode Sound(LED OFF) LED On Slow blinking Fast blinking
Select Manua Color or color 1-32
Select show 1-8 or Auto fade
Select Speed
1. Slow
2. middle
3. Fast
4.3 DMX Controller
Use universal DMX controller to control the units, you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal. Press the MENU button up to when the DMX Address is showing on the display. Press ENTER button and the display will blink. Use DOWN and UP button to change the DMX512 address. Once the address has been selected, press and keep ENTER button to store. To go back to the functions without any change press the MENU button or wait for 1 minute to exit menu mode. Please refer to the following diagram to addressyour DMX512 channel for the first 4 units:
4.1 Master/Slave Built In Preprogrammed Function
By linking the units in master/slave connection, the first unit will control the other units to give an automatic, sound activated, synchronized light show. This functionis good when you want an instant show.
2-light show
In slavemode, slave 1means the unit run as the master unit and slave 2 means 2-light show. In order to create a great light show, you can set slave 2 on the second unit to get contrast movement to each other, even if you have two units only.
8-
Channel Mode Unit 1 Unit 2 Unit 3 Unit 4
3 channels 1 4 7 10 6 channels 1 7 13 19
9 channels 1 10 19 28 12 channels 1 13 25 37 15 channels 1 16 31 46
9-
4.4 DMX 512 Configuration
PRELIMINARY MANUAL
Front View:
DMX Configuration:
10-
11-
4.5 DMX512 Connection
PRELIMINARY MANUAL
1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable.
2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
3. Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the input of the next unit. The cable can not branched or split to a `Y` cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system.
4. The DMX output and input connectors are pass-through to maintain the DMX circuit, when power is disconnected to the unit.
5. Each lighting unit needs to have an address set to receive the data sent by the controller.The address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX 512 system should be terminated to reduce signal errors.
7. 3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
Pin 4/5: Not used.
12- 13-
5. Troubleshooting
PRELIMINARY MANUAL
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interfacecircuit.
C. Some units don’t respond to the easy controller
1. You may have a break in the DMX cabling.
2. Check the LED for the response of the master/ slavemode signal.
6. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics.
Clean with soft cloth using normal glass cleaning fluid.Always dry the partscarefully.Clean the external optics at least every 20 days. Clean the internal optics at least
every 30/60 days.
EC Declaration of Conformity
We declarethat our products (lighting equipments) comply with the following
specification and bears CEmark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55103-1:199601-2; EN55103-2:1996;
EN61000-3-2:2000+A2:2005;
EN61000-3-3:1995+A1:2001+A2:2005.
D. No response to the sound
1. Make sure the unit does not receive DMX signal.
2. Check if the sound sensitively is too low.
E. One of the channels is not working well
1. The cable connected to the PCB may broken.
Following the provisions of the low voltage directive 73/23/EEC and 93/68/EEC
14-
Harmonized Standard
EN 60598-1: 2004
IEC 60598-1:2003+ corrigendum 2004
Part 1:General requirements and test
15-
&
Loading...