Beglec IR-5B, IR-6SD, IR-7B, IR-6S, IR-6B User Manual

...
Technical Specifications
IR-7S/IR-7B/IR-5C
Power AC 120V~60Hz or AC 230/240/250V~50/60Hz
Fuse 20mm Glass 10A Fast Blow
Lamp MSD 250/2
Dimension
Weight
IR-6S/IR-6B/IR-6SD/IR-6BD/IR-5S/IR-5B/IR-4C
Power AC 120V~60Hz AC 230/240/250V~50/60Hz
Fuse 20mm Glass 6.3A Fast Blow 20mm Glass 5A Fast Blow
Lamp
Dimension
Weight
IS-6S/IS-6B/IS-4/IS-3
Power AC 120V~60Hz AC 230/240/250V~50/60Hz
695 x 340 x 250 mm (IR-7S/IR-7B) 360 x 340 x 250 mm (IR-5C)
15 kg (IR-7S/IR-7B)
9.2kg (IR-5C)
ELC 24V 250W CDM 150W (IR-6SD/IR-6BD)
695 x 340 x 250 mm (IR-6S/6B/6SD/6BD/5S/5B) 360 x 340 x 250 mm (IR-4C)
10.6 kg (IR-6S/IR-6B/IR-5S/IR-5B)
10.7 kg (IR-6SD/IR-6BD) 8 kg (IR-4C)
Fuse 20mm Glass 6.3A Fast Blow 20mm Glass 5A Fast Blow
Lamp ELC 24V 250W
Dimension
Weight
685 x 380 x 200 mm (IS-6S/IS-6B) 375 x 380 x 200 mm (IS-4/IS-3)
9.4 kg (IS-6S/IS-6B)
7.5 kg (IS-4/IS-3)
Innovation , Quality , Performance
User Guide
WWW.BEGLEC.COM
.
TABLE OF CONTENTS
1. Safety Instruction
2. Technical Specification
2.1 Inserting/Exchanging rotating gobos
2.2 Beam Angel
3. Lamp
4. How To Set The Unit
4.1 Control Panel
4.2 Main Function
5. How To Control The Unit
5.1 Master/Slave Built-In Preprogrammed Function.
5.2 Easy Controller
5.3 iSolution Operation / Universal DMX Controller
5.4 Universal DMX Controller
5.5 DMX512 Configuration
5.6 DMX512 Connection
6. Troubleshooting
7. Fixture Cleaning
7. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in which
the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
y Clean with soft cloth using normal glass cleaning fluid.
y Always dry the parts carefully.
y Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
2A
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55014-1: 1993, EN61000-3-2: 1995, EN61000-3-3:1995 EN55014-2: 1997 CATEGORY II EN61000-4-2: 1995, EN61000-4-3: 1995, EN61000-4-4:1995 EN61000-4-5: 1995, EN61000-4-6: 1995, EN61000-4-11: 1994
&
Harmonized Standard
EN60598-1: 1993 Safety of household and similar electrical appliances Part 1 : General requirements
Following the provisions of the Low Voltage Directive 73/23/EEC and 93/68/EEC.
We declare that our products (remote controller) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55015: 1993 EN50082-1: 1997 EN61000-3-2: 1995 EN61000-3-3: 1995
EC Declaration of Conformity
6. Troubleshooting
Following are a few common problems that may occur during operation. Here are some
suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connect power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of
the unit or the previous one.
4. Try to use another DMX controller.
5. Check in the DMX cables run near or run alongside to high voltage cables that may
cause damage or interference to DMX interface circuit.
C. Some units don’t respond to the easy controller
1. You may have a break in the DMX cabling. Check the LED for the response of the
master/ slave mode signal.
2. Wrong DMX address in the unit. Set the proper address.
D. No response to the sound
1. Make sure the unit that does not receive DMX signal.
2. Check microphone to see if it is good by tapping the microphone
E. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
F. The lamp is cutting out intermittently
1. The lamp is not working well. Check the main voltage either too high or too low.
2. Internal temperature may be too high. Check and if necessary replace the fan on the
head.
1. Safety Instruction
Please read carefully the instruction, which includes important
WARNING
Please keep this User Guide for future consultation. If you sell the unit to another
user, be sure that they also receive this user guide.
Unpack and check carefully there is no transportation damage before using the unit.
Before operating, ensure that the voltage and frequency of power supply match the
power requirements of the unit.
It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
The unit is for indoor use only. Use only in a dry location.
The unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
Disconnect main power before fuse/lamp replacement or servicing.
Replace fuse/lamp only with the same type. Do not use any other type of lamp.
Make sure there is no flammable materials close to the unit while operating as it is
3A
fire hazard.
Use safety cable when fixes this unit. Don’t handle the unit by taking its head only,
but always by taking its base.
Maximum ambient temperature is TA: 40℃. Don’t operate it where the temperature
is higher than this.
Unit surface temperature may reach up to 85C. Don’t touch the housing bare-hand
during its operation. Turn off the power and allow about 15 minutes for the unit to
cool down before replacing bulb or serving as the unit could be very hot.
In the event of serious operating problem, stop using the unit immediately. Never try
to repair the unit by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance
center. Always use the same type spare parts.
Don’t connect the device to any dimmer pack.
Do not touch any wire during operation as high voltage might be causing electric
shock.
information about installation, operation and maintenance.
.
Warning
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
Never touch bulb with bare fingers as it is very hot after using.
Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.
Do not start on the unit without bulb enclosure or housing are damaged.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
Do not look directly at the light while the bulb is on.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt
any repairs yourself. In the unlikely event your unit may require service, please contact
your nearest dealer.
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is
firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to
which you are attaching the unit is secure and is able to support a weight of 20 kgs for each
unit
5.5 DMX512 Connection
The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels.
1.If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable.
4A
2.At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W
resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the
DMX-output of the last unit.
3.Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the
input of the next unit. The cable can not branched or split to a `Y` cable. DMX512 is a very
high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors
can easily distort the signal and shut down the system.
4.The DMX output and input connectors are pass-through to maintain the DMX circuit, when
power is disconnected to the unit.
5.Each lighting unit needs to have an address set to receive the data sent by the controller.
The address number is between 0-511 (usually 0 & 1 are equal to 1).
6.The end of the DMX512 system should be terminated to reduce signal errors.
7.3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
Loading...
+ 9 hidden pages