![](/html/4e/4e05/4e05e80b89770ac6303af880f40f93b8552be0ead7428871add54e21bb8096a6/bg1.png)
Technical Specifications
IM-8S
Power AC 120V~60Hz or AC 230/240/250V 50/60Hz
Fuse 20mm Glass 10A Fast Blow
Lamp MSD 250/2
Dimension 360mm x 397mm x 503mm
Weight 26 kg
IM-7S
Power AC 120V~60Hz or AC 230/240/250V 50/60Hz
Fuse 20mm Glass 7A Fast Blow
Lamp HTI 150W
Dimension 373mm x 295mm x 451 mm
Weight 13 kg
IM-8S IM-7S
User Guide
Innovation , Quality , Performance
WWW.BEGLEC.COM
![](/html/4e/4e05/4e05e80b89770ac6303af880f40f93b8552be0ead7428871add54e21bb8096a6/bg2.png)
7. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in which
the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60
days.
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
EN61000-4-11: 1994.
&
Harmonized Standard
EN60598-1: 2000+ALL:2000+A12:2002
Safety of household and similar electrical appliances
Part 1 : General requirements
TABLE OF CONTENTS
1. Safety Instruction
2. Technical Specification
2.1 Inserting/Exchanging rotating gobos
2.2 Beam angel
3. Lamp
4. How To Set The Unit
4.1 Control Panel
4.2 Main Function
5. How To Control The Unit
5.1 Master/Slave Built-In Preprogrammed Function.
5.2 Easy Controller
5.3 iSolution Operation / Universal DMX Controller
5.4 DMX512 Configuration
5.5 DMX512 Connection
6. Troubleshooting
7. Fixture Cleaning
![](/html/4e/4e05/4e05e80b89770ac6303af880f40f93b8552be0ead7428871add54e21bb8096a6/bg3.png)
1. Safety Instruction
Please read carefully the instruction,
information about the installation, usage and maintenance.
WARNING
♦ Please keep this User Guide for future consultation. If you sell the unit to another
user, be sure that they also receive this instruction booklet.
♦ Unpack and check carefully there is no transportation damage before using the unit.
♦ Before operating, ensure that the voltage and frequency of power supply match the
power requirements of the unit.
♦ The unit is designed for use with the MSD 250/2 ( IM-8S ) or HTI 150 ( IM-7S ). Do
not use any other type of lamp.
♦ It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
♦ The unit is for indoor use only. Use only in a dry location.
♦ The unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
♦ Disconnect main power before fuse/lamp replacement or servicing.
♦ Replace fuse/lamp only with the same type.
♦ Make sure there are no flammable materials close to the unit while operating, as it
is fire hazard.
♦ Use safety cable when fixes this unit. Don’t handle the unit by taking its head only,
but always by taking its base.
♦ Maximum ambient temperature is Ta : 40℃. Don’t operate it where the temperature
is higher than this.
♦ Unit surface temperature may reach up to 85℃. Don’t touch the housing bare-hand
during its operation. Turn off the power and allow about 15 minutes for the unit to
cool down before replacing bulb or serving.
♦ In the event of serious operating problem, stop using the unit immediately. Never try
to repair the unit by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance
center. Always use the same type spare parts.
♦ Don’t connect the device to any dimmer pack or power pack.
♦ Do not touch any wire during operation as high voltage might be causing electric
shock.
H. If The IM-7S pan belt is broken
1. Turn off the main power.
2. Unscrew all the screws (A) and open the base-housing cover (B).
3. Unplug all the connect wires (C) that from the arm to PC board and igniter.
4. Unscrew the screws (D) that fix the bridge (E).
5. Unscrew the screws (F) that fix the axis gear (G).
6. Change a new belt (H) by going through all connecting wires that from the arm to base,
and through the bridge for correct position.
7. Set up the gear axis to the bridge and screwed it. Note: do not press the belt.
8. Put the belt around the axis gear and motor gear.
9. Plug all the connect wires (C) that form the arm to PC board and igniter.
10. Adjust the pan home position.
11.Screw the base-housing cover (B).
G
H
D
A
B
A
D
E
C
F
A
B
![](/html/4e/4e05/4e05e80b89770ac6303af880f40f93b8552be0ead7428871add54e21bb8096a6/bg4.png)
Pay attention to the belt tension when install the belt.
Please refer to the photos below: ( For IM-8S )
Photo 1
Photo 2
.
Warning
♦ To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
♦ Never touch bulb with bare fingers as it is very hot after using.
♦ Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.
♦ Do not start on the unit without bulb enclosure or housing are damaged.
♦ The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
♦ Do not look directly at the light while the bulb is on.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt
any repairs yourself. In the unlikely event your unit may require service, please contact
your nearest dealer.
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit
is firmly fixed to avoid vibration and slipping while operating. Always ensure that the
structure to which you are attaching the unit is secure and is able to support a weight of 30
kgs for each unit ( Below drawing is for IM-8S only ).