Vista & Vista Plus
VST & VST-PLUS
EAC H MODEL NUMBER CONSIST S OF THE F OLLOWING:
SERIES / OPERATION / LUMENS / WATTAGE / DISTRIBUTION /
VOLTAGE / WET LOCATION / WEIGHT
SERIES: VST & VST-PLUS
OPERATION: HT (AC ONLY)/0-10V DIMMING
LUMENS: VISTA (1730 - 6250), VISTA PLUS (11,200 - 38, 500)
WATTAGE: VISTA: 15W/30W/50W
VISTA PLUS: 80W/100W/120W/150W/200W/240W/
300W
DISTRIBUTION: TYPE III
VOLTAGE: 120-277V; 347V
WET LOCATION: IP65
WE IGH T: VISTA (1 - 3.5 LBS.), VISTA PLUS (12.5 - 23 LBS.)
INSTALLATION INSTRUCTIONS
VIS TA VISTA PLUS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
1. Do not let power cords touch hot surfaces.
2. Do not mount near gas or electric heaters.
3. Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering.
4. The use of accessory equipment not recommended by Beluce Canada Inc., may cause an unsafe condition, and will void the warranty.
5. Do not use this equipment for other than its intended purpose.
6. Servicing of this equipment should be performed by qualified service personnel.
7. Mounting options differ for different power ratings.
SAVE THESE INSTRUCTIONS!
CAUTION ! ALWAYS MAKE SURE THE POWER IS TURNED OFF before starting the installation
Wiring fixture to power supply shall be performed by a certified electrician and wired in a manner that complies with all local and national electrical
codes, as well as the manufacturer’s wiring diagram.
926000472
No user serviceable parts. Refer service to a qualified service
technici an. Read ins tructi ons prior to installin g and/or op erating
this devi ce. Insta llation sh ould be per formed by a li censed
electrician/installer in accordance with local codes.
1Beluce Canada Inc., 3900 14th Avenue, Markham, ON L3R 4R3 Tel: (905) 948-9500 Fax: (905) 948-8673

VISTA
Black/Brown: 120-277VAC
White/Blue: Neutral
Black/Brown: 120-277VAC
White/Blue: Neutral
TYPICAL INSTALLATION
Wiring Diagram for Vista Series
Knuckle Mounting (for 15, 30 & 50W)
1. Pass the three wires through the rubber mat; ( figure 1.1)
2. Match the hole of the rubber mat with the bracket, pass the wires through and fasten with screws (Take
care not to damage the wires); (figure 1.2)
3. Pass the wires through from the other bracket and fasten it with screws. (Take care not to damage the
wire); (figure 1.3)
Figure 1.1 Figure 1.2 Figure 1.3
4. Finish the wire connection (pay attention to the live, neutral and ground wires), and then put wire into
luminaire pole; (figure 1.5)
5. Loosen screws; Adjust luminaire angle as required and tighten the screws.
Hex screw
Black/Brown: 120-277 VAC
Green/Yellow: ground
White/Blue: neutral
2 Beluce Canada Inc., 3900 14th Avenue, Markham, ON L3R 4R3 Tel: (905) 948-9500 Fax: (905) 948-8673
Figure 1.4
Pole
Figure 1.5 Figure 1.6
926000472

VISTA
MOUNTING
U-Bracket Mounting
1. Pass the wires through the bracket hole;
2. Attach the luminaire and bracket together with screws;
(Take care not to damage the wires) (figure 2.2)
3. Attach the other bracket with screws (figure 2.3)
Figure 2.1
Figure 2.2 Figure 2.3
4. Finish the wire connection (pay attention to the live wire, neutral wire, and ground wire), and then put wires
into weatherproof j-box (by others).
5. Loosen screws; Adjust luminaire angle as required and tighten screws. (figure 2.5)
Figure 2.4 Figure 2.5
Bracket
Hex screw
Black/Brown: 120-277 VAC
Green/Yellow: ground
White/Blue: neutral
Yoke Mounting (for all Vista models)
1. Tighten the brackets and screws. (figure 3.2)
Figure 3.1 Figure 3.2
926000472
3Beluce Canada Inc., 3900 14th Avenue, Markham, ON L3R 4R3 Tel: (905) 948-9500 Fax: (905) 948-8673

VISTA & VISTA PLUS
As for the wire color of DIM+
and DIM-, always check the
labels.
MOUNTING
Yoke Mounting (con’t)
2. Finish the wire connection (pay attention to the live, neutral and ground wires), then put the wires into a
weatherproof j-box (by others). (figure 3.3)
3. Loosen screws; Adjust luminaire angles as required and tighten screws. (figure 3.4)
Figure 3.3 Figure 3.4
Bracket
Hex screw
Black/Brown: 120-277 VAC
Green/Yellow: ground
White/Blue: neutral
Wiring Diagram for Vista Plus Series
Black/Brown: 120-277 or
347VAC
Green/Yellow: ground
White/Blue: neutral
Green/Yellow: ground
White/Blue: neutral
Black/Brown:
120-277 or 347VAC
Slipfitter for pole mounting (for all Vista Plus models)
1. Separate the bracket with a screwdriver. (figure 4.1, A.)
2. Put input wire of the light through the bracket. (figure 4.2, A.)
3. Thread the input wire through the bracket (figure 4.1, B.) and reassemble the bracket (figure 4.3)
4. Adjust the luminaire as required and tighten screws.
A.
80.35mm
Figure 4.1 Figure 4.2 Figure 4.3
4 Beluce Canada Inc., 3900 14th Avenue, Markham, ON L3R 4R3 Tel: (905) 948-9500 Fax: (905) 948-8673
B.
64.50mm dia.
A.
A.
B.
926000472

VISTA PLUS
MOUNTING
U-Bracket Mounting (for Vista Plus models)
1. Put the input wire of the light through the bracket. (figure 5.1)
2. Set the bracket and tighten the screws. (figure 5.2)
Figure 5.1 Figure 5.2
Yoke Mounting (for Vista Plus models)
1. Remove the side; feed the input wire through the back housing (Option A) or the side cover (Option B) of
the light, then attach the side cover and tighten the screws. Attach the bracket to the fixture. (figure 6.1)
Figure 6.1
Side cover
Option A
Option B
SAVE THESE INSTRUCTIONS!
926000472
5Beluce Canada Inc., 3900 14th Avenue, Markham, ON L3R 4R3 Tel: (905) 948-9500 Fax: (905) 948-8673