LUXOMAT® LC-Mini 120 / 180
GB
Installation and Operation Instruction motion detector
1. Mounting preparations
1
2
1) Caution: have all work involving the
230V mains supply carried out by a
qualified electrician! Before starting
disconnect the mains! Please be aware,
that the LUXOMAT® LC-Mini 120/180 is
not suitable as an intrusion detector, since
it is not equipped with a tamper contact.
2) Socket base corner mounting
Important: The LUXOMAT
120/180 has to be mounted in such a way,
that the adjusting elements / rotary regulators
are always pointed downward.
®
LC-Mini
2. Mounting types
1
1) Wall mounting
3. Plug-in socket
N
L
L
N
L’
Mount the plug-in socket with two screws and
the enclosed seal rings on a firm base.
(Pay attention to inserting of the connection
cable, see point 4)
L’
B.E.G. – LUXOMAT® LC-Mini 120 and LC-Mini 180
4.
Inserting of the connection cable
N
L’
L
1) Connection cable from top down
2) Terminal markings
5. Sensor head optics
By swinging the sensor head horizontally
(ca. ±45°) and vertically (ca. ±15°) the
detection area can be changed.
6. Connection
7.
Exclude sources of interference
Cover
If necessary, the lens segment(s) corresponds to
unwanted detection zones may be masked with
the enclosed covers to reduce the fi eld of vision.
8. Putting into operation / Settings
Self test cycle
After mounting and connecting the 230 VAC supply
voltage, the detector pass a self-test. Afterwards the
settings can be made manually.
1.2
50
20
4
sec
6
10
min
10. Mounting place
1
1) If possible mount unit on a safe place
(wall or ceiling mount)
50
20
4
sec
40
2000
260
20
Lux
2
260
2000
2
2) Influence of weather reduces the lifetime of
the unit. Please take care to mount correctly.
9. Range of Coverage
1.2
6
Follow-up time
4 sec. ...10min.
10
min
40
Lux value
20
Night operation...Dusk...Day operation
(Day operation: light sensor inactive, switching
Lux
2
at any brightness value)
walking towards
1
walking across
2
2
1
3
> 1m
1
4
3) Minimum distance to switched lighting,
frontally or laterally to device: 1m
4) Never mount the connected lights below the
motion detector!
2
walking towards
1
walking across
2
11. Wiring diagrams
Standard mode with 1-channel motion detector
L
N
Standard mode with 1-channel motion detector with
permanent light function
L
N
Standard mode with 1-channel motion
detector with NC pushbutton
L
N
E1
N L L‘
C1
Parallel connection with 1-channel motion detectors
L
N
E1
N
L‘
L L
N
C1
L‘
C1
E1 S1
N L L‘
optional:
C1
RC
S1 = switch for permanent light
RC = RC-suppression kit if required
Standard mode with 1-channel motion detector
(e.g. stairs)
L
N
T2
E1
L
N
L‘
T1
N
30 s -
10min.
4
E1T7
T 1 = NC button
Manual switching additionally possible (press opener
approx. 2 sec.).
L
N
L
3
L‘
C1
12. Dimensions (mm)
58
N
L’
L
41
7
22
7
48
22
10
38
13.
Trouble Shooting-Practical hints
1. Lamp does not light up
Cause - Action
Lamp is defective
- Replace light bulb.
No mains connection
- Check mains fuse.
Switching threshold of the twilight switch is not
correct
- Accordingly adjust sensitivity of twilight
switch via the setting dial.
Detection area not set correctly
Set detection area correctly.
Unit mounted too high
- Mount at recommended height (2.50m)
PIR detector lens obstructed by dirt or other
objects
- Clean lens or remove objects
2. Delayed lamp activation
Mounted too high
- Mount at height stated in specication
(2.5 m)
Only direct in-line approach of detector is
possible
- Mount detector in such a way that a
sideways approach is also detected.
3. Lamp stays on continuously
Continuous thermal movement within detection
area
- Remove the heat source out of the detection
area.
Check the correct functioning of the detector
in fully covering the lens (lights should go out
after a certain time-delay).
Motion detector is switched parallel to a switch
that enables direct manual switching on
- Mind the correct connection of the switch.
4. Light source remains on for long periods
when no persons are present
Permanent inuence from heat sources within
detection area (trees, shrubs when blown by
the wind, presence of animals like cats and
dogs in the detection area)
- Reduce detection area of the detector in
turning the detector head downward or
cover parts using the enclosed covers.
Direct sunlight radiation into detector lens
- Shelter lens from direct sunlight.
Detector mounted above extractor fan
- Change mounting place of the detector.
5. Limitation of range (not up to the minimum
specication)
Mounting height is not optimal
- Accordingly change mounting height
(2.50 m).Persons only move directly towards
the detector
- Mount detector in such a way that a
sideways approach is also detected.
Steep terrains
- Adjust spherical head accordingly.
6. No reaction to vehicles
Vehicle not warmed up
Vehicle is well insulated (by silencing equipment)
14. Technical data
Power supply
Detection area
120°
LC-Mini 180
180°
Range of coverage in m:
max. 10m when walking across (tangential
Degree of protection/class:
IP 44 / II /
Dimension:
: 230 V~ ±10 %
: LC-Mini 120
)
L 80 x B 55 x H 70 mm
Ambiente temperature: -25°C to +50°C
Package:
Housing UV- and
shock-resistant Polycarbonate
Chanel 1 for light control
Contact load:
Time-settings:
1000W, cosφ = 1
4 s - 10min.
Brightness value: 2 - 2000 Lux
Declaration of Conformity:
The product complies with the low voltage
recommendation 2006/95/EC/ and the EMV
recommendation 2004/108/EC.
15.
Article / Part nr. / Accessory
Typ Colour Part nr.
LC-Mini 120 white 91051
LC-Mini 120 black 91071
LC-Mini 180 white 91052
LC-Mini 180 black 91072
Accessory:
RC-Suppressor 10880
MAN 6936 – 181113 - 3