B.E.G. Brück LUXOMAT® LC-Mini 120, LUXOMAT® LC-Mini 180 Operating Instructions

LUXOMAT® LC-Mini 120 / 180
7 m
4 m
10 m
180°
2,50 m
7 m
4 m
10 m
120°
2,50 m
GB
Installation and Operation Instruction motion detector
1
2
1) Caution: have all work involving the
230V mains supply carried out by a qualified electrician! Before starting disconnect the mains! Please be aware, that the LUXOMAT® LC-Mini 120/180 is not suitable as an intrusion detector, since it is not equipped with a tamper contact.
2) Socket base corner mounting
Important: The LUXOMAT 120/180 has to be mounted in such a way, that the adjusting elements / rotary regulators are always pointed downward.
®
LC-Mini
2. Mounting types
1
1) Wall mounting
3. Plug-in socket
N
L
L N L’
Mount the plug-in socket with two screws and the enclosed seal rings on a firm base. (Pay attention to inserting of the connection cable, see point 4)
L’
B.E.G.LUXOMAT® LC-Mini 120 and LC-Mini 180
4.
Inserting of the connection cable
N
L’
L
1) Connection cable from top down
2) Terminal markings
5. Sensor head optics
By swinging the sensor head horizontally (ca. ±45°) and vertically (ca. ±15°) the detection area can be changed.
6. Connection
7.
Exclude sources of interference
Cover
If necessary, the lens segment(s) corresponds to unwanted detection zones may be masked with
the enclosed covers to reduce the fi eld of vision.
8. Putting into operation / Settings
Self test cycle
After mounting and connecting the 230 VAC supply voltage, the detector pass a self-test. Afterwards the settings can be made manually.
1.2
50
20
4 sec
6
10 min
10. Mounting place
1
1) If possible mount unit on a safe place (wall or ceiling mount)
50
20
4 sec
40
2000
260
20
Lux
2
260
2000
2
2) Influence of weather reduces the lifetime of the unit. Please take care to mount correctly.
9. Range of Coverage
1.2
6
Follow-up time
4 sec. ...10min.
10 min
40
Lux value
20
Night operation...Dusk...Day operation (Day operation: light sensor inactive, switching
Lux
2
at any brightness value)
walking towards
1
walking across
2
2
1
3
> 1m
1
4
3) Minimum distance to switched lighting, frontally or laterally to device: 1m
4) Never mount the connected lights below the motion detector!
2
walking towards
1
walking across
2
11. Wiring diagrams
Standard mode with 1-channel motion detector
L
N
Standard mode with 1-channel motion detector with permanent light function
L
N
Standard mode with 1-channel motion detector with NC pushbutton
L
N
E1
N L L‘
C1
Parallel connection with 1-channel motion detectors
L
N
E1
N
L‘
L L
N
C1
L‘
C1
E1 S1
N L L‘
optional:
C1
RC
S1 = switch for permanent light RC = RC-suppression kit if required
Standard mode with 1-channel motion detector (e.g. stairs)
L
N
T2
E1
L
N
L‘
T1
N
30 s -
10min.
4
E1T7
T 1 = NC button
Manual switching addition­ally possible (press opener approx. 2 sec.).
L
N
L
3
L‘
C1
12. Dimensions (mm)
58
N
L’
L
41
7
22
7
48
22
10
38
13.
Trouble Shooting-Practical hints
1. Lamp does not light up Cause - Action
Lamp is defective
- Replace light bulb.
No mains connection
- Check mains fuse. Switching threshold of the twilight switch is not correct
- Accordingly adjust sensitivity of twilight
switch via the setting dial.
Detection area not set correctly Set detection area correctly. Unit mounted too high
- Mount at recommended height (2.50m)
PIR detector lens obstructed by dirt or other objects
- Clean lens or remove objects
2. Delayed lamp activation
Mounted too high
- Mount at height stated in specication
(2.5 m)
Only direct in-line approach of detector is possible
- Mount detector in such a way that a
sideways approach is also detected.
3. Lamp stays on continuously
Continuous thermal movement within detection area
- Remove the heat source out of the detection
area.
Check the correct functioning of the detector in fully covering the lens (lights should go out after a certain time-delay).
Motion detector is switched parallel to a switch that enables direct manual switching on
- Mind the correct connection of the switch.
4. Light source remains on for long periods when no persons are present
Permanent inuence from heat sources within
detection area (trees, shrubs when blown by the wind, presence of animals like cats and dogs in the detection area)
- Reduce detection area of the detector in turning the detector head downward or cover parts using the enclosed covers.
Direct sunlight radiation into detector lens
- Shelter lens from direct sunlight.
Detector mounted above extractor fan
- Change mounting place of the detector.
5. Limitation of range (not up to the minimum
specication)
Mounting height is not optimal
- Accordingly change mounting height (2.50 m).Persons only move directly towards
the detector
- Mount detector in such a way that a sideways approach is also detected.
Steep terrains
- Adjust spherical head accordingly.
6. No reaction to vehicles
Vehicle not warmed up Vehicle is well insulated (by silencing equip­ment)
14. Technical data
Power supply Detection area
120° LC-Mini 180 180°
Range of coverage in m: max. 10m when walking across (tangential
Degree of protection/class: IP 44 / II /
Dimension:
: 230 V~ ±10 %
: LC-Mini 120
)
L 80 x B 55 x H 70 mm
Ambiente temperature: -25°C to +50°C
Package:
Housing UV- and
shock-resistant Polycarbonate
Chanel 1 for light control Contact load: Time-settings:
1000W, cosφ = 1
4 s - 10min.
Brightness value: 2 - 2000 Lux
Declaration of Conformity:
The product complies with the low voltage recommendation 2006/95/EC/ and the EMV recommendation 2004/108/EC.
15.
Article / Part nr. / Accessory
Typ Colour Part nr.
LC-Mini 120 white 91051
LC-Mini 120 black 91071
LC-Mini 180 white 91052
LC-Mini 180 black 91072
Accessory:
RC-Suppressor 10880
MAN 6936 – 181113 - 3