Operating and mounting instructions for motion detector LUXOMAT® RC-plus next
GB
1. Mounting preparations 2. Mounting types
1
2
1) Caution: have all work involving the 230 V
mains supply carried out by a qualified
electrician! Before starting disconnect the
mains! Please be aware, that the LUXOMAT
RC-plus next is not suitable as an intrusion
detector, since it is not equipped with a
tamper contact.
2) Socket base corner mounting
3) In the case of mounting over the previous
socket “RC-plus” use the extra cover that is
provided.
3
®
1) Wall mounting
2) Ceiling mounting
3) Outside corner mountable with plug-in
socket (included with the RC-plus next 280,
see point 20)
3. Plug-in socket
32
1
4. Inserting of the connection cable
4
1
1
2
10°
2
3
3
3
1) Press here for separation of terminal case
and plug-in socket
2) Mount the plug-in socket with two screws
and the enclosed seal rings on a firm base
(Pay attention to inserting of the connection
cable, see point 4)
3) Imprint the terminal case on plug-in socket.
The terminal case on the plug-in socket is
rotatable upto 10° for fine adjustment of the
motion detector.
2
1) Connection cable from top down
2) Connection cable from below
3) Connection cable from behind
4) Terminal markings
(Wiring diagrams see point 17)
4
5. Putting into operation / Settings
5
Self test cycle
After mounting and connecting the 230 VAC supply
voltage, the LED flashed for 1min. to show a self testing
unit. Then the unit is ready for operation and the settings can be made manually or with remote control
(see point 11).
1
1) Remove the coverring with slightly pressure
2) Adjust Range, follow-up accommodation and Lux value with screwdriver
7. Sensor head optics
7
2
8. Sensitivity adjustment (mounting height 2.50 m);
10°
2
+
TEST
8 9
mounting height min. = 2.00 m
(Sensor head justified horizontally, see point 7)
130°
1
180°
21m
1
45°
1) Change range or sensitivity adjustments
by swivelling of the sensor head vertically
or horizontally (Sensor head horizontally =
max. range)
2) Fine adjustment of sensor axis
10
10. Mounting place
1 2
1) If possible mount unit on a safe place
(wall or ceiling mount).
2
1) Range walking across: approx. 21m
2) Range walking towards: approx. 7 - 8m
3) Anti-creep: approx. 1 - 3m
2) Influence of weather reduces the lifetime of
the unit. Please take care to mount correctly.
1m 3m
3
8m
Mechanical range adjustment
+: e.g. 21m, –: e.g. 5m (mounting height 2.50 m)
-
mounting height min. = 2.00m
(RC-plus next 130: 1 zone; RC-plus next 230:
2 zones; RC-plus next 280: 3 zones, see point 8)
Follow-up time
Test operation, 15sec. ... 16min., Pulse operation
(Test operation: range testing, detector switches
on/off the lighting at any recognized movement)
Lux value
Night operation...Dusk...Day operation
(Day operation: light sensor inactive, switching at
any brightness value)
LED Functional display
Display of movements and operating states
(Switchable with remote control LUXOMAT
see point 11)
230°
21m
1m 3m
8m
21m
max min
Mechanical range adjustment possible
for every zone separately (see point 5)
3) Minimum distance to switched lighting,
4) Never mount the connected lights below the
4
frontally or laterally to device: 1m
motion detector!
21m
3
> 1m
280°
1m 3m
®
IR-RC,
8m
6. Factory settings
6
& “TEST”
On delivery the potentiometers are adjusted in
position “TEST” and “SUN” symbol (daytime
operation). With this adjustments the following
regular values are active:
Follow-up accommodation: 3min.
Lux value: approx. 20Lux
Reset: The adjusting into “Factory settings” from
any other position causes a “Reset” of the device.
That means all parameters are resetted into factory
settings (fast LED-flashing).
9. Exclude sources of interference
21m
1
1) Push in cover-up clips on marked place
(blind out distant range/close-up range/
both)
2) Cover-up stickers
11. Settings of remote control
11
1
®
1) LUXOMAT
2) LUXOMAT® IR-RC-Mini (accessory, see
point 20)
Caution: Settings with remote control subscribe
the settings by courtesy of potentiometers (see
point 5 ) (for description see point 12).
IR-RC (accessory, see point 20)
2
2

12. Functions of LUXOMAT® IR-RC
Unlocking device
Lux value: Day operation
light sensor inactive, switching
at any brightness value
Lux value: approx. 100Lux
Onset of dusk
Lux value: approx. 25 Lux
Advanced dusk
Lux value: approx. 2 Lux
Darkness
Automatic reading in the
current light value
Individual light value
2 - 2500Lux
Follow-up time
15 sec. upto 16 min.
Impulsfunction
1sec. ON, 9 sec. OFF
Anti-creep protection
Switching ON/OFF
Walk test
Switching ON/OFF
Alarm function
Switching ON/OFF,
(ON for 30sec., OFF for
1sec., then normal operation)
Vacation- and comfort function
Switching ON/OFF
On: By achieving the Lux value
1 hour daylight independent
of mouvements, then normal
operation (switching time
changeable, see point 15)
Sensitivity adjustment
~ +15%, ~ – 30 %
Reset
Erasing of all of the values set
using the remote control.
(Then potentiometer-settings
activ, see point 5.)
Lock device (by pressing the button
shortly)
Double lock devise (sabotage protection)
Keep the button pressed while LEDs
flash. As soon as the LEDs are on permanently, the double-locking is active.
Test operation
Switches the light ON/OFF when
movement is detected.
Light ON for 12h / Light OFF for 12 h
By pressing once the party button, the
light is switched on for a period of 12
hours. By pressing the party button
twice, the light remains switche off until
the next evening (see point 14).
Light OFF
Switches the light ON again when
movement is detected.
Reset
Light OFF, then automatic mode
Caution: The infrared receiver of the
RC-plus next is positioned in the anticreep protection. For best reception
target anti-creep with remote control.
13. Functions of LUXOMAT
IR-RC-Mini
Light ON for 12h / Light OFF for 12 h
By pressing once the party button, the
light is switched on for a period of 12
hours. By pressing the party button
twice, the light remains switched off
until the next evening (see point 14).
Reset
Light OFF, then automatic mode
1)
14. Activation “Light OFF”
Because of the sabotage protection the function
“Light off” is deactivated in the factory. When
required it must be activated again:
1. Mains to be disconnected
2. Mains to be connected - a self test cycle
of 60sec. starts (the LED is flashing, see
point 5).
Activation/deactivation of the function “Light
3.
Off” can be done only during the self testing
cycle
For a
ctivation of the function “Light OFF”
the button “Light OFF” must be pressed
during the self testing cycle (the LED will
flash quickly).
For deactivation “Light OFF” the button
“Reset” must be pressed during the self
testing cycle (the LED will flash slowly).
Caution: The implementation of “Reset” with potentiometers (see point 6) or with remote control
(see point 12) does not influence the activation/
deactivation of the function “Light OFF”
15. Vacation- and comfort function
The duration of the on-period can be adjusted:
1. “Unlock” unit with remote control
2. The button “Co“ to be operated. The LED
flashes for 10sec.
3. During these 10 seconds the duration of the
light-on period can be selected: from e.g.
15sec. = 15min. up to 16 min. = 16 hrs
4. The unit to be locked with the button “Lock”.
5. “Vacancy/Comfort” is activ now (deactivation see point 12)
Caution: If the “Vacation- and comfort function”
is active or with lower deviation of the Lux value
the RC-plus next turns on the light again after a
time delay of 60sec.
18. Wiring diagrams
Standard operation
(with optional arc extinctions kit)
Optional extension for switching of parallel
inductors, rocker switches, fluorescent lamps etc.
N L’
RC
N L’
L
N L’
L
Terminal connection for parallel operation
We recommend max. 5 motion detectors.
N L’
L
Permanent light operation with external push
button
Additionally manuel switching is possible. The
NC-contact is to press for approx. 0.5 - 2sec.
L
Permanent light operation with external switch
Switching is manually possible (permanent light
operation). Caution: Light has to switched off
manually.
16. Follow-up time savings
The energy saving and comfort by courtesy of
follow-up accommodation of the motion detector
RC-plus next is unique. That means: If the last
detected movement is located in the anti-creep
zone (for instance mounting over a doorway),
the follow-up accomodation will be reduced to
1/4 of the original time = energy saving.
f.ex.: adjusted follow-up accommodation = 16min.
a) Walking towards unit: effective follow-up
accommodation = 4min.
b) Removing from unit: effective follow-up
accommodation = 16min.
Caution: The “dynamic follow-up accommodation“ will be activeted or deactivated on following conditions:
Follow-up accommodation “active”:
> Unit is located in “factory settings“
(see point 6)
> Settings of follow-up accommodation with
remote control values 15sec. - 16 min.
(see point 12)
Follow-up accommodation “inactive”:
> Settings of follow-up accommodation with
potentiometers values 15sec. - 16 min.
(see point 5)
17. Measurement of daylight
The RC plus next constantly measures the
ambient luminosity and compares the measured
value with the set value. In case the lights are
switched on by the RC plus next, they will be
switched off after 90 minutes for a short time
to allow for evaluation of the current ambient
luminosity. If the measured value of ambient
luminosity still is below the set value, the lights
are switched on again.
®
19. Dimensions (mm)
120
RC-plus next 230°
46
63
120
57 27
63
20. Technical data
Power supply: 230V~ ±10 %
Rated capacity: 16A relay
Switching power: 33000W, cosϕ =1
1500VA,
Range: approx. 20m
Time settings: Impuls, 15sec. – 16min.
Follow-up accommodation:
Photo electric switch: approx. 2 - 2000Lux
Factory settings:
Detection area: 130° / 230° / 280°,
Degree of protection/class: IP54 / II
Dimensions:
Material: UV-stabilised Polycarbonate
Colours: white / black / brown /
Mounting types: wall and ceiling mounting,
Inserting of the connection cable:
once or twice from top
Range adjustment: > selective mechanical ad-
> swivelling of the sensor
> electronic +15% up to
> With blank out clips
Electrical adjustments: in traditional manner
LED-Display: one LED per detection
active with factory settings
and with programming of
remote control LUXOMAT®
IR-RC (15 sec. - 16min.)
follow-up accommodation
3 min., photo electric switch
approx. 20Lux
360° anti-creep protection
L 121 x W 71 x H 85mm
silver (only RC-plus next
230)
RC-plus next 280: outside
corner mountable with
inclused plug-in socket
down, from below and
from behind
justment for every zone in
the 130°, 230° and 280°
unit
head: vertically –10 upto
+45°, horizontally + –90°,
laterally ±10°
30% with remote control
LUXOMAT® IR-RC
(included)
with potentiometers valid
for time and Lux value
only, with infrared remote
control.
zone
21. Article / Part nr. / Accessory
®
LUXOMAT
RC-plus next 130 white: 97001
brown: 97011
black: 97021
RC-plus next 230 white: 97002
brown: 97012
27
black: 97022
silver: 97042
RC-plus next 280 white: 97003
57
brown: 97013
black: 97023
LUXOMAT
IR-RC (incl. wall bracket) 92000
IR-RC-Mini 92090
LUXOMAT
63
RC-plus next ES white: 97004
RC-plus next ES brown: 97014
RC-plus next ES black: 97024
RC-plus next ES silver: 97043
Motion detector:
®
Remote control:
®
Socket base for corner mounting:
(With LUXOMAT® RC-plus next 280 included)
Accessory:
Arc extinction kit 10880
Wall bracket for IR-RC as replacement 92100
1)
As soon as the function “Chime/Impulse”
is activated, the following functions will
be blocked: Alarm function, Light ON for
12hrs / Light OFF for 12hrs, Vacation-
and comfort function
cosϕ = 0.5