B.E.G. LUXOMAT TRV2-ZW Installation And Operating Instructions Manual

1. Part / Part No. / Accessories
LUXOMAT® Thermostat
TRV2-ZW: 92046
For accessories, refer to www.luxomat.com/en-92046
1 TRV2-ZW energy saving radiator thermostat 1 User manual 1 Connector 3 Adapters
Application as directed
With the TRV2-ZW energy-saving control, you have acquired a wirelessly connected radiator control designed to control tem­peratures in enclosed rooms and thus reduce heating energy consumption.
Please use the thermostat only for this purpose.
The TRV2-ZW programming port is intended ONLY for our USB­TRV2 (Accessory: 92054). Never connect other devices with the
programming port!
2. Display and control elements
1 Heating times 2 Child lock
active
3 Battery
low
4.a Travel function
active
4.b Wireless connection
active
4.c Comfort temperature
active
4.d Economy temperature
active
4.e Window/freeze protection
function active
5 AUTO or MANU mode active
6.a Button
MENU
– leads to the main menu (starting from regular display); within the menu one keypress leads to the previous level
6.b Button
OK
– conrmation of setting
6.c Button
– timer function
7 Selector wheel
3. Set up menu
By pressing
MENU
you will arrive at the set up menu. Please
choose one of the items with the selector wheel. With
OK
you can select one menu item and with the selection wheel they can be adjusted. The button
OK
conrms the setting. The button
MENU
leads to the previous level.
to select the mode
AUTO = automatic mode MANU = manual mode PRAE = PRESENCE mode APRA = Automatic mode + additional presence
detection setting of time programme setting of comfort and economy temperature
setting of date and time
window function
reset of the device to factory preset
starting of a new adaptation
to adjust the valve travel function
installation function
adaptation of temperature to the room situation
4. Inserting / replacing batteries
Remove the battery cover where indicated using a screwdriver and pulling the cover off.
Then insert the batteries as shown in the illustration.

f Do not use rechargeable batteries! Ensure that the
polarity is correct!
Attention:
Never recharge batteries, danger of explosion!
Do not short-circuit batteries!
Do not disassemble batteries!
Take low batteries out of the device immediately.
Keep batteries away from extreme warming – danger of
leakage!
Do not apply used and new batteries together. If needed, clean the battery and the contacts before using them.
Keep the batteries away from children.
When getting in touch with battery acid instantly irrigate the
affected parts with clear water and call a doctor.
5. Setting date and time
After inserting the batteries for the rst time the date will ash
on the display. Now, date and time can be set.
Set date with the selector wheel. Conrm with
OK
.
Set month with the selector wheel. Conrm with
OK
.
Set day with the selector wheel. Conrm with
OK
.
Set hour with the selector wheel. Conrm with
OK
.
Set minute with the selector wheel. Conrm with
OK
Th at´s it . On the display
will be shown. Now, the motor will com­pletely move to the installation position in order to make the installation easier. As soon as TRV2-ZW is ready for installation
will be shown on the display.
You can also set date and time via the menu item
later on. But in case of that, TRV2-ZW does not move to the installation position.
f In case of replacing batteries, the stored time
programme will remain active. You should check the
specied time to ensure that.
6. Creating the wireless connection
1. Initialise the device before it logs in for the rst time. The
menus may be navigated by using the adjusting wheel and function keys. You can navigate to the menu item with
MENU
f f OK f and conrming with OK
2.
The login procedure may now commence. To commence the login procedure, switch the MyControl to learning mode:
f f The learning procedure for the TRV2-ZW is also started in the next step.
MENU
f f OK f f OK A symbol representing the radiator control will be shown in the MyControl display when the learning procedure has been concluded.
3. Only the time for the repeater‘s cyclical query now needs to be set. This time also automatically determines the maximum period before the heating is switched on af ter movement has been detected. The options are: 3, 4 or 5 minutes. You may navigate to these settings via
MENU
f
OK
f f
Example
..... f OK
7. Installation
TRV2-ZW can be quickly and easily mounted on all common valves (see adapter table). It can be installed without grime and water spots because the heating circuit is not interrupted.
1. Turn the manual thermostat head up completely, loosen the fastening and pull the thermostat off of the valve.
2. Use an appropriate adapter, if required, and push it onto the valve.
3. Screw the connector on the valve or the adapter.
4. Now, you put TRV2-ZW on the connector until it noticeably clicks into place.
f In case of a later installation please switch in the
menu to before you install the device. Herewith the installation is facilitated.
8. Dismounting
f In order to dismount TRV2-ZW press the releasing
device to loosen the locking device. Now, pull the TRV2­ZW off of the valve.
9. Adaptation
Initial installation: Press the button OK until appears on the display so that TRV2-ZW will be able to start its adaptation. The device will adapt itself to the stroke of your valve body. To do this the valve will now be opened and closed several times to store the end points. In some cases this process can take a few minutes. After success­ful adaptation it returns to normal mode.
f Should adaptation become necessary again, e.g. if
your radiator does not cool down in the position, please press in the menu the button until adapta­tion starts again.
f If the mistake
is shown on the display place TRV2-ZW onto the radiator valve and then take the batteries out for a short time in order to execute a reset.
10. Basic operating modes
MANU-mode
In the MANU-mode TRV2-ZW adjusts to the manually specied
temperature.
AUTO-mode
In AUTO mode, he TRV2-ZW operates as a standalone unit (without motion detection) and switches between t wo tempe ­ratures depending on the settings made in the timer program:
comfort temperature (factory preset 21°C)
economy temperature (factory preset 16°C)
PRESENCE MODE
In presence mode, the TRV2-ZW will switch the heater to the set comfort temperature when it detects motion. Otherwise the tem­perature will remain at the previously set economy temperature.
AUTO-PRESENCE MODE
Auto-presence mode combines automatic mode with presence
mode, i.e. xed heating times may set during which the economy control switches the heating to the specied comfort temperature.
When economy temperature is active, the unit will adjust the heating depending on its presence-detection, i.e. it will activa­te the heating if it senses any movement.
The heating and economy times can be specied via the ad­justable time programme. It is possible to set 8 switch points (4 heating and 4 economy times) per day at the most. TRV2-ZW has the following factor y preset:
B.E.G.
Installation and operating instructions for
B.E.G. – programmable energy-saving radiator thermostat LUXOMAT® TRV2-ZW
LUXOMAT
®
TRV2-ZW
GB
i
i
i
i
i
USB-TRV2 (Accessory optional)
TRV2-ZW
1
4
2 3
5
7
6
Heating time:
Heating with comfort temperature (factory preset: 1st heating time at 07:00)
Economy time:
lowering to economy temperature (factory preset: 1st economy time at 22:00)
11. Setting heating and economy times
With TRV2-ZW it is possible to set 4 heating and 4 economy times per day – one for each day or one for a block of several days. TAG1 to TAG7 represent the weekdays from Monday to Sunday. Additionally, the corresponding days are shown as ab­breviation below the menu bar on the display.
Block construction:
T 1–5 = same programme from Monday to Friday T 1–6 = same programme from Monday to Saturday T 1–7 = same programme from Monday to Sunday
f For non-programmed days the factory preset
remains active.
Setting of an individual programme:
Press
MENU
. Select the menu item with the selector wheel. Press
OK
.
for Monday is shown on the display.
Select day/block with the selector wheel. Conrm with
OK
.
Set the beginning of the 1st heating time (symbol
) with the
selector wheel. Conrm with
OK
.
Set the beginning of the 1st economy time (symbol
) with the
selector wheel. Conrm with
OK
.
Now, if desired, a 2nd, 3rd or 4th heating/economy time can be entered.
f If you do not want to set a further heating/economy
time conrm “
“ with OK.
The next day for programming is shown on the display.
f If you do not want to enter a further day, leave the
menu with
MENU
. If the temperature is shown on the
display the programming is finished.
f Within the blocks you can also over write single days
with differing times.
12. Setting comfort and economy temperature
Press
MENU
. Select the menu item with the selector
wheel. Confirm with
OK
. Set comfort temperature with the
selector wheel. Conrm with
OK
. Set the economy tempera-
ture with the selector wheel. Conrm with
OK
.
Area
: 8°C, freeze protection function is active
Area
: valve is completely open
f By the way: Maximum energy saving can be
obtained with an economy temperature which is about
5˚C below the comfort temperature.
13. Manual operation
With the selector wheel an adaptation of the room temperature is possible at any time. In the AUTO - mode it remains active un­til the next switch point is reached. Now, the usual programme becomes active again.
14. Further functions
Timer function
The timer function is selected with the timer-but ton
.
With
this function a user-dened temperature for a programmable
period can be entered. This can be very useful in case of a party, for example. Press
. First, the time for which the
time
programme has been deactivated is shown. Conrm with
OK
. Now, the desired temperature can be set. Conrm with
OK
.
Offset
If the perceived temperature signicantly differs from the set
thermostat temperature a temperature set up can be executed. Press
MENU
. Select the menu item with the selector
wheel. Confirm with
OK
. The degree setting
will flash on the display. Now, set up the desired adaptation for the temperature (from -5 up to +5°C) with the selector wheel. Confirm your entry with
OK
. The temperature
display does not change!
Window function If you open a window and consequently the temperature drops
signicantly, TRV2-ZW will automatically close the heating valve in order to save energy. The display will show
. Af­terwards, TRV2-ZW will resume normal operation. For the set up select
in the menu. Confirm with
OK
. First, the sensibility is selected with the selector wheel ( = high sensibilit y, = medium sensibility (factory preset), = low sensibility).
Conrm with
OK
. Now, you enter the time (10 min. (factory
preset) - 60 min.) for which the valve should remain closed.
Conrm with
OK
.
Travel function
For the time you are absent you can select an individual tem-
perature. After this period the originally dened programme
becomes active again. Press
MENU
. Select the menu item . Conrm with OK
(suitcase
appears on the display). Select with the selector
wheel the end of the travel function (= date of the recommence-
ment of the regular heating times). Conrm with
OK
. Set the
time and conrm with the button
OK
. The signal appears
on the display. Now set the temperature and conrm with
OK
.
appears on the display. With
MENU
the function can
be deactivated.
Child lock
You can lock TRV2-ZW to protect the device from unauthorized activation. Press the buttons
OK
+
at the same time for about 2
seconds until the signal
appears on the display in order to
lock the device. By using this button combination again the symbol disappears and you release the lock.
Heating pause – Closing the TRV2-ZW
Press
MENU
. Select the menu item with the selector wheel.
Conrm with
OK
. Select and conrm with
OK
. Set the temperature on the display to . The valve is now closed and will work withou t a tim e programme. The calcicati on pro­tection function remains active once a week. After the heating pause you switch in the menu to the AUTO-mode and the per­sonally set programme will be executed again.
Going back to factory preset/All reset
Press
MENU
. Select the menu item with the selector wheel.
Conrm with
OK
. ashes, conrm with OK. TRV2-ZW is reset again. Now, proceed as described for the initial ope ­ration.
Freeze protection and calcication protection function are active automatically:
Freeze protection function
If the temperature drops below 6°C, TRV2-ZW opens the valve until the temperature again rises above 8°C. This prevents the radiators from freezing.
Calcication protection function
To prevent radiator valves from calcifying TRV2-ZW is submit-
ted to a calcication protection programme once a week on
Friday mornings.
LCD-Display Standby
Press
MENU
. Choose menue point “STBY” with the selector
wheel. Conrm with
OK
and choose “ON/OFF“ with the
selector wheel. After a period of 30 seconds the LCD display switches into standby mode. By pressing any button the dis­play will be reactivated (reset of standby mode by removing the battery). This will prolong bat tery life.
15. Logging the unit out of the system
Start MyControl unlearning mo de
f f
The TRV2-ZW‘s unlearning mode will be activated.
MENU
f f OK f f OK
Alternatively, the unit may also be unlearned using
X in
the MyControl‘s submenu.
16. Cleaning and used devices
Cleaning
To clean the TRV2-ZW use only a dry or lightly wet cloth. Avoid chemical solvent – it will probably damage the device.
Used devices
Do not throw old devices and packaging into the household waste. They can be recycled. You receive further information at your local government or at WEEE directive coverage.
17. Adapters
Heimeier, Junkers Landys+Gyr, MNG, Honeywell, Braukmann thread-measure dimension of M 30x1,5
no adapter required
Danfoss R AV (accompanying pin must be plugged on the valve tapped)
Danfoss RA
Danfoss RAVL
18. Help
Problem Cause Solution
Batteries do not have enough power.
Replace batteries.
ashing.
Wireless connection not working
Please check whether all wireless subscribers have been correctly connected.
Heating element does not warm up.
Is the boiler water temperature O.K.?
Valve does not open,
is it calcied after
the summer pause / heating pause?
Adjust the temperature of the boiler water.
Remove the TRV2-ZW, move the valve system back and forth per hand or with a tool.
Heating element does not cool down.
Valve does not close completely. It may be that the closing point of your valve seat has shifted.
Adapt again (see
“Adapting”) Move the
valve stem several times by hand, it may be that adaptation is impossible because your valve is
calcied or the seat
no longer performs its function.
Pressure piece drops out.
The pressure piece which is located on the bottom, can drop out due to a continu­ous thread.
Insert pressure piece. Press
MENU
. Choose
in the menu items with the help of the adjusting wheel. Conrm with
OK
. Now the continuous thread rotates and fastens the pressure piece again.
No adaptation possible.
Is the installation OK?
TRV2-ZW is not ins­talled to the heater.
Valve stroke is too short.
Install TRV2-ZW to the heater.
Open and close the valve several times manually or replace the batteries.
Motor movement is not possible.
Does the valve stem move freely?
19. Technical data
Power supply: Battery 2 x AA 1,5V Nominal voltage: 2,1 - 3,6V Transmission and
reception frequency: 868,42 MHz Transmission power: <10mW Transmission and
reception range (open area): max. 100m
Number of subscribers: up to 80 (recommended) Sensibility:
Variable adjustable: 0,5°C, 1,0°C, 1,5°C and 2,0°C
Child lock included Dimensions
Housing: L 82 x W 55 x D 65mm Display: W 29 x H 21mm Ambient temperature: +5°C – +45°C
i
i
i
i
+ accompanyin g pin, only for RAV!
MAN 7408 – 280612–1
Loading...