B.E.G. LUXOMAT LC-Click-N 140, LUXOMAT LC-Click-N 200 Installation And Operation Instruction Manual

Page 1
10 m
4 m
12 m
140°
2,50 m
2 m
10 m
4 m
200°
2,50 m
2 m
LUXOMAT® LC-Click-N 140 / 200
GB
Installation and Operation Instruction motion detector B.E.G.LUXOMAT® LC-Click-N 140 and LC-Click-N 200
6. Mounting types
1) Wall mounting
3.
Inserting of the connection cable
1) Cable entry points
2) Terminal markings
7. Putting into operation / Settings
Self test cycle
After mounting and connecting the 230 VAC supply volta­ge, the LC-Click-N 140/200 runs a self testing unit. Then the unit is ready for operation and the settings can be made manually or with remote control.
2. Wall mounting
Mount the plug-in socket with two screws and the enclosed seal rings on a firm base. (Pay attention to inserting of the connection cable, see point 3)
4. Sensor head optics
By swinging the sensor head horizontally (ca. 90°) and vertically (ca. 85°) detection area can be changed.
5.
Exclude sources of interference
8. Range of Coverage
Walking Towards
Walking across
Anti-creep
1
Walking Towards
Walking across
Anti-creep
1) If possible mount unit on a safe place (wall or ceiling mount)
2) Influence of weather reduces the lifetime of the unit. Please take care to mount correctly.
3) Minimum distance to switched lighting, frontally or laterally to device: 1m
4) Never mount the connected lights below the motion detector!
If necessary, the lens segment(s) corresponds to unwanted detection zones may be masked
with the enclosed covers to reduce the eld
of vision.
1
2
1
2
1
3
3
3
3
Follow-up time
4sec. ... 10Min.
Lux value
Night operation...Dusk...Day operation (Day operation: light sensor inactive, switching at any brightness value)
1. Mounting preparations
1) Caution: have all work involving the
230V mains supply carried out by a qualified electrician! Before starting disconnect the mains! Please be aware, that the LUXOMAT
®
LC-Click-N 140/200 is not suitable as an intrusion detector, since it is not equipped with a tamper contact.
2) Socket base corner mounting
The device is not suited for safe disconnection of the mains supply.
Important: The LUXOMAT
®
LC-Click-N 140/200 has to be mounted in such a way, that the adjusting elements / rotary regulators are always pointed downward.
Caution: Do not connect more than2 LUXOMAT® LC-Click-N in one circuit, to avoid any erroneous switching.
1
2
2
1:4
1.
0.5
0.25 Futura Book 24Pt
> 1m
1000
40
10
130
2 Lux
4 sec
20
1.2
10 min
6
50
1000
40
10
130
2 Lux
4 sec
20
1.2
10 min
6
50
1
2
1
2
Page 2
Article Colour Part.-nr.
LC-Click-N 140 white 91001
LC-Click-N 140 black 91021
LC-Click-N 140 brown 91011
LC-Click-N 200 white 9100 2
LC-Click-N 200 black 91022
LC-Click-N 200 brown 91012
Accessory: RC-Suppressor 10880
13.
Article / Part nr. / Accessory
12. Technical data
Power supply
: 230 V~ ±10 %
Detection area
: LC-Click-N 140
140° LC-Click-N 200 200° and 360° anti-creep protection
Range of coverage in m: max. 12m when walking across (tangential
)
Degree of protection/class: IP 44 / Class II /
Dimension:
L 103 x B78 x H 80mm
Ambiente temperature: -25°C to + 50°C
Package:
Housing UV- and shock-resistant Polycar­bonate
Chanel 1 for light control Contact load:
1000W, cosφ = 1 ,
µ-Contact
Time-settings:
4 s - 10min.
Brightness value: 2 - 2000 Lux
Declaration of Conformity:
The product complies with the low voltage recommendation 2006/95/EC/ and the EMV recommendation 2004/108/EC.
10. Dimensions (mm)
MAN 7023 – 111012- 6
9. Wiring diagrams
N
L
N L L‘
C1
E1
L
N
E1 S1
RC
N L L‘
C1
N
N
L
L
L‘
C1
E1T7
L
L L
C1
C1
L‘
L‘
N
N
N
E1
L
L
L
L‘
N
N
N
E1
T1
T2
30 s -
10min.
4
3
Standard mode with 1-channel motion detector
Standard mode with 1-channel motion detector with permanent light function
Standard mode with 1-channel motion detector with NC pushbutton
Parallel connection with 1-channel motion detectors max. 2 parallel
Standard mode with 1-channel motion detector (e.g. stairs)
optional:
S1 = switch for permanent light RC = RC-suppression kit if required
T 1 = NC button
Manual switching additionally possible (press opener approx. 2 sec.).
11.
Trouble Shooting-Practical hints
1. Lamp does not light up Cause - Action
Lamp is defective
- Replace light bulb.
No mains connection
- Check mains fuse.
Switching threshold of the twilight switch is not correct
- Accordingly adjust sensitivity of twilight switch via the setting dial.
Detection area not set correctly Set detection area correctly. Unit mounted too high
- Mount at recommended height (2.50m)
PIR detector lens obstructed by dirt or other objects
- Clean lens or remove objects
2. Delayed lamp activation
Mounted too high
- Mount at height stated in specication (2.5 m)
Only direct in-line approach of detector is possible
- Mount detector in such a way that a sideways approach is also detected.
3. Lamp stays on continuously
Continuous thermal movement within detec­tion area
- Remove the heat source out of the detec­tion area.
Check the correct functioning of the detector in fully covering the lens (lights should go out after a certain time-delay). Motion detector is switched parallel to a switch that enables direct manual switching on
- Mind the correct connection of the switch.
4. Light source remains on for long periods when no persons are present
Permanent inuence from heat sources within
detection area (trees, shrubs when blown by the wind, presence of animals like cats and dogs in the detection area)
- Reduce detection area of the detector in turning the detector head downward or cover parts using the enclosed covers.
Direct sunlight radiation into detector lens
- Shelter lens from direct sunlight.
Detector mounted above extractor fan
- Change mounting place of the detector.
5. Limitation of range (not up to the minimum
specication)
Mounting height is not optimal
- Accordingly change mounting height (2.50 m).Persons only move directly towards
the detector
- Mount detector in such a way that a sideways
approach is also detected.
Steep terrains
- Adjust spherical head accordingly.
6. No reaction to vehicles
Vehicle not warmed up Vehicle is well insulated (by silencing equipment)
78
78
60
36
67
80
Loading...