Installation and Operating Instruction for B.E.G. - Occupancy detector PD4-M-DALI/DSI-SM/FC
1. Product information
Occupancy detector for daylight-dependent lighting control
DALI / DSI interface for controlling digitally dimmable electronic ballasts as a group
Switching between DSI and DALI program by remote control or DIP switch
Extension of the detection area by slave devices is possible
Other functions adjustable by remote control (optional)
Manual switching and dimming via pushbutton possible
Orientation light function
2. Operation
The presence detector controls the light automatically according to people present (movements) and the ambient brightness.
The integrated light sensor constantly measures the ambient light and compares it with the set value brightness on the detector. If the ambient light is sufficient, lighting will not be switched. If the ambient light level is below the set value brightness, a movement activates the lighting in the room.
The detector switches the light off despite of a person being pres­ent if there is enough natural light for 5 min or if no movement is detected for one follow-up time.
5a. Position DIP switches, LEDs and
Potentiometer SM
5b. Position DIP switches, LEDs and
Potentiometer FC
PD4-M-DALI/DSI
Light measurement
I II III
CBA
PD4-Surface
mounting
C B
A
DIP
1
2
3
I II III
DIP switch functions
DIP 1 Full automatic mode
(VA)
DIP 2 LED ON
DIP 3 Operation mode DALI Operation mode DSI
Potentiometer A Brightness (constant light control) Potentiometer B Follow-up time light Potentiometer C Follow-up time (orientation light)
LED I green LED II red LED III white
®
LED OFF
3. Safety information
Work on the 110-240V mains supply may only be carried out by qualified professionals or by
!
instructed persons under the direction and super­vision of qualified skilled electrical personnel in accordance with electrotechnical regulations.
!
Disconnect supply before installing!
This device is not suitable for disconnection.
!
Mounting the cover ring after introduction of the
!
power cable (FC version).
4. Mounting
In master/slave mode, the master device must always
!
be installed at the location with least daylight.
The light sensor must be positioned facing away from
!
the window.
4a. Mounting
open
close
4b. Mounting
68 mm
Figure 2
SM
The detector has to be mounted on a plane and solid surface. Before mounting, the lense has to be removed. To do so, twist the lense anticlockwise through approx. 5° and lift off.
Having connected up the cables in accordance with regulations, put on the lense by turning in a clockwise direction (see fig. 1). Apply mains voltage.
Figure 1
FC
A circular opening of diameter 68mm must be produced in the ceiling. Having connected up the cables in accordance with regula­tions, the detector is inserted into the opening and fixed into position with the assistance of the spring clips (see figure 2).
Light
PD4-
False ceiling
mounting
3
1
2
measurement
DIP
6. Self test cycle/Startup behavior
The product enters an initial 60-second self-test cycle, when the supply is first connected. During this time the device does not respond to movement and stays on.
7. Putting into operation/Settings
Brightness value for constant light control (Potentiometer A)
The brightness set value can be defined between 10 and 2000Lux. The potentiometer enables a free selection of the brightness value.
Symbol
:
Symbol :
Follow-up time “Light” (Potentiometer B)
The follow-up time can be set to 1 to 30 minutes. Symbol TEST: test mode
Irrespective of the brightness, every movement switch­es the light on for 1sec., then off again for 2 sec.
Follow-up time orientation light (Potentiometer C)
Manually switching the orientation light on/off. “ON” for permanent orientation light “OFF” for switching off the orientation light
Night-time operation Daytime operation (light evaluation inactive)
8. Wiring diagram
Standard mode with Master/Slave device(s)
L
L
L
N
N
T1
M1
S
N
LN RS + -
Master-Gerät
Connected Slave devices must have the same phase as the
!
Master device.
DA1
L
N
N
E1 DALI/DSI
E1 DALI /DSI
DA
DA DA
DA
T2
+L‘
RL
-
DA1
N LR
Slave-Gerät
LR
N
9. Manual switching and dimming (see section 23)
By pressing the push button, the phase can be given to the S terminal.
To turn on or off the light, press the push button briefly. The light will remain on or off, as long as people are detected plus the follow-up time.
With a long press of the push button the light will be dimmed manually. When releasing the button, the current brightness value is retained. With renewed long press of the push button, the dimming direction is reversed.
10. Range
quer zum Melder gehen frontal zum Melder gehen Unterkriechschutz
2.50 m
24 m
360°
1
Walking across Walking towards
2
Seated activity
1
6.40 m 8 m
24 m
11. Exclude sources of interference
SM
14. LED function indicators
LED function indicators
Process Standard mode Double-locked
Initialisation time unprogrammed
Initialisation time programmed
Motion detection
2
Too bright detected
Too bright / too dark / undefined in opened state
Switching DALI/DSI DSI active
Switching DALI/DSI DALI active
Switching HA/VA Semi-automatic mode (HA) active
Switching Preset/User Preset active
Switching Preset/User User active
IR signal valid received
IR signal invalid received
100 h function active
Light measurement in progress
Red flashes
Red flashes quickly
Red flashes on each detected movement
Red flashes 2x per second
Green flashes very quickly
Red shines 3 sec.
Green shines 3 sec.
White shines permanently
Red shines 3 sec.
Green shines 3 sec.
Red and white shine 3 s
Red shines 0,5 sec.
Red / Green flash alternately
Green flashes 1x in 10 sec.
Green flashes
Green flashes quickly
Green flashes on each detected movement
Green flashes 2x per second
Green flashes very quickly
Red / Green flash alternately
Green flashes 1x in 10 sec.
FC
If the detection zone is too large, or areas are covered that should not be monitored, use the blinds to reduce or limit those areas.
12. Technical data
Power supply: 110-240VAC, 50/60Hz Power consumption: approx. 1W Ambient temperature: Degree of protection/class: IP20 / II Max. no. of series-connected electronic ballasts: up to 50 (Broadcast) Range of coverage Ø H 2,5 m /T =18°C:
Area of coverage: Recommended height for mounting: Dimensions H x Ø [mm]
63 x 98 103 x 97mm
Declaration of Conformity:
2 - 3 m
This product respects the directives concerning
-25°C to +50°C
seated 6.4m / tangential 24m / frontal 8m circular 360°
SM FC
1. electromagnetic compatibility (2004/108/EU)
2. low voltage (2006/95/EU)
3. restriction of the use of certain hazardous substances in electrical and electronic equipment (2011/65/EU)
13. Article / Part nr. / Accessory
Type SM FC
PD4-M-DALI/DSI 92279 922 75
®
LUXOMAT
Remote control:
IR-PD-DALI-E (incl. wall bracket) - General remote control 92122 IR-PD-DALI (incl. wall bracket) 92094 IR-PD-DALI-Mini 92112 IR-PD-DALI-LD (incl. wall bracket) 92652 IR-Adapter with Smartphone-App 92726
Accessory:
BSK Wire basket 9219 9 Wall bracket for remote control as replacement 92100 SM-Socket IP54 92161
15. Settings with remote control (optional)
max
50
Lux
1500
Lux
ON
max
50
Lux
1500
Lux
1500
Lux
1500
Lux
1500
Lux
(see also section 24)
Settings with remote control override the potentiometer
!
and DIP settings.
The DIP settings are reactivated by
setting the potentiometers to „TEST“ and „SUN“ (see
section 24), or
pressing the RESET button on the remote control in open state
Infrared remote control LUXOMAT® IR-PD-DALI-E
1. Check Battery:
Open battery compartment by pressing the plastic springs together and remo­ving the battery-holder.
2. Note
Using the remote control, the occupancy detector can only be operated brightness-depending. The setting „SUN“ can only be chosen with potentiometer A.
When using the remote control IR-PD-DALI-E, we recommand to set potentiometer A to „SUN“. Pressing the RESET button on the remote control then resets the detector to brightness-independant mode (SUN).
IR-PD-DALI-E
Wall bracket for remote control IR-PD-DALI-E
16. S ettings by remote control when open
Unlock device – Activation of the programming mode
Switching between DSI Resetting when open:
Deletes all values set with the remote control, light OFF.
DSI/
DALI
or
or
+
and DALI program
The Factory setting
is DALI
Dimming of the
lighting to the
desired brightness
value
Automatic reading
in the current light
value as new lumi-
nance set value
Stepwise adjusting the
set value brightness
from 50 to 1500 lux:
+/– step 5 Lux
+/– step 10 Lux
step 20Lux
+/–
Follow-up time
30
min
light
Orientation light
OFF
on/off
Follow-up time
10
orientation light
min
Preset/User-mode (see section 23)
Full automatic /semi-
automatic mode (se.18)
Start light measure­ment by long press of the button (see section 17)
Exit programming mode
If there is no entry for about 3 min. the programming mode is ended automatically.
optionaloptionaloptionaloptional
min
ON
min
1
1
to
to
optional
t < 5 s
Red LED ashes
Double lock
17. Light regulation
The detector has two different integrated light control algorithms.
The set value for the rst algorithm is adjusted by potentiometer
(LUX) on the device. Very small light amounts, which shine directly to the detector, have as result that the set value bright­ness is exceeded.
The second algorithm has an integrated daylight compensation. Therefore, it is necessary that the detector analyses the switched light quantity. This algorithm can only be used by remote control. The programming of the set value and the measurement of the light quantity is carried out in two steps:
In the open state
• The set value is adjusted without daylight (please darken the room) by using the remote control.
• Measuring the light quantity will be initiated by a long press (> 3 sec) of the test button. The detector turns the light on for 5 min. at 100%. Then the light will turn on and off for a short time and stays on after that. This measuring pro-
cess is shown by a ashing green LED (10 sec off/ 1 sec
on). This measuring process is required for each change of the set value. If the setting “permant orientation light” is chosen, the function only will be active after the measuring process is done.
If the measuring process is not performed, the detector performs it automatically when the ambient light is less than 50 lux for 1h.
18. Full / Semi-automatic mode
Full automatic operation
In this operating mode, the lighting switches automatically on and off for increased comfort, depending on presence and brightness.
Semi-automatic operation
In this operating mode, the light turns on only after a manual switching, for an increased savings success (see section 22). Switching off is automatically or manually The semi-automatic mode basically behaves like the full automatic mode. The only difference is that the switching on has to be done by hand. In case motion is detected within the 10s after elapse of the follow-up time, the detector switches the light on again and the follow-up time starts again. If there is no motion detected within the 10 s after elapse of the follow-up time, the light has to be turned on manually.
(
see section 22
).
19. Settings during the Self-test cycle
In the rst 60 seconds after connecting the AC voltage, the
following functions can be set:
INI-OFF/O
Turn off or turn on the light during the self-test cycle of 60 sec. The last state is active. Factory setting is that the light is on during initialisation.
When INI OFF is chosen, the detector does not switch on the light after voltage supply. Even upon detected
!
movement the light is switched on only after 60 s.
Startup behavior
The set value can be reached in two ways after switching on. The detector switches the lights on at 10% and then adjusts upwards (min button) or it switches the light on at 100% and regulates down (max button). This is confirmed by a short flashing of the red and white LED as well as the lighting. Factory setting is that the detector switches the light on at 100%.
Reset of electronic ballasts
If required the connected EB can be reset and preset parameter can be deleted. Press the button “Reset” for 3 seconds in initialisation mode.
N mode:
:
20. Test mode/Reset
Test mode
Use „Test“ button for activating the test mode and the „Reset“ button to deactivate it.
Reset in closed state
The lighting is switched off, and the follow-up times are reset.
Reset in open state
Pressing the button for >3s deletes all settings (except of INI ON/OFF) and the detector is reset to factory state.
21. 100h function (
long press
(> 3 s)
when closed
Before the lamp can be dimmed, the dimming function has
!
to be suppressed for a certain time in order to burn in the lamps.
T5 uorescent lamps: 80h T8 uorescent lamps: 100h
For activating the function, press button state. During this time, the detector only switches the light ON or OFF. A dimming to the set value does not take place. After having
activated the function, the red and green LED ash alternately. By
pressing the button vate the function before the time has elapsed.
Failure to comply to the burn-in would lead to reducing the life of the lamp. A further disadvantage could be unwanted random variations in light intensity.
„Light ON/OFF“
)
„Light ON/OFF“
again, it is possible to deacti-
in closed
22. Manual Switching
short press when closed)
(
You can switch the lighting on and off manually by pressing the pushbutton or the remote control button „Light ON/OFF“ for a short time. It will stay on or off as long as people are detected
plus the congured follow up time.
23. Manual Dimming - Preset/ User
(long press when closed)
You can dim manually by pressing the external push button or the remote control buttons "min/max" – for a long time (> 2sec.). When the button is released, the current dimming value is retained. Upon renewed dimming, the dimming direction is reversed.
Two different operating modes are selected
in the opened state.
Changing the mode is done by pressing the "double lock" button. Each time the button is pressed, the current operating mode is indicated: Red shines for 3sec. = Preset Green shines for 3sec. = User
PRESET –
the set value brightness is set during start-up operation by
the installer and remains unchanged. The set value brightness con-
gured through manual dimming is only applied for the time being.
The constant light regulation is now deactivated! The current set
articial light is retained independent of the ambient/daylight
brightness! After switching off and then back on, the original set
set value brightness
activated.
USER can only be activated via the remote control
The
set value brightness and re-adjusted by the user. The constant light regulation remains activated!
is reset = constant light regulation is
is changed upon each manual dimming
24. Reset the detector
If the double lock is activated, the detector can be opened again as follows:
Disconnect operating voltage
Connect operating voltage for 31s to 59s
Disconnect operating voltage again
Connect operating voltage again and wait for the self testing
Open detector With this procedure, the remote control programmed values are not
deleted (before activation of the double lock). If the setting is not changed by remote control after deactivation of the double lock, the detector changes in the double locked mode again after a period of 30 minutes. This way the detector cannot be unlocked during an accidental power failure.
Alternatively, the detector can be reset in this way: Set potentiometer A to “Sun” and potentiometer B to “Test”. The de­tector now is in test mode and the potentiometer settings are active. All operating LEDs are flashing for three seconds.
Except of the INI ON/OFF setting, the detector is reset to factory setting or the setting of the potentionmeter.
Pushing the „RESET“ button on the remote control, in opened mode, will delete all of the values which were set by the remote control (beside of INI ON/OFF) and set the detector back to its factory settings.
Factory settings The detector is delivered with the following factory settings: lux value: 500 Lux, follow-up time: 10 minutes Starting the detector in the factory program the initialisation mode starts with a constant ashing of the three operating LEDs.