BEETLE NET POS User Manual

Page 1
BEETLE /NetPOS
Modular POS System
User Guide
Edition August 2002
Page 2
Copyright© Wincor Nixdorf International GmbH, 2002
The reproduction, transmission or use of this document or its contents is not permitted without express authority.
Linux™ is a registered trademark of Linus Torvalds Pentium™ is a registered trademark of the Intel Corporation MS-DOS™, Windows 95™, Windows 98™, Windows NT™ and Windows CE™ are registered trademarks of the Microsoft Corporation BEETLE™ is a registered trademark of Wincor Nixdorf International GmbH
Page 3
Contents
Manufacturers Certification................1
Tested Safety ...............................1
FCC-Class A Declaration .........................1
Important notes ..............................2
Introduction ........................4
About this manual .............................5
Care of the BEETLE /NetPOS.......................5
Recycling the BEETLE /NetPOS .....................6
Warranty..................................7
BEETLE /NetPOS .....................8
Overview .................................8
BEETLE /NetPOS Peripherals .....................9
BEETLE /NetPOS in a network ....................10
Before switching on the System .....................11
Unpacking and checking the System .................11
Setting up the device .........................12
Cabling of the BEETLE /NetPOS ...................13
Disconnecting cables .........................13
Mounting the cable cover .......................14
Connecting to the mains power supply ................15
Basic settings .............................16
Adjusting the loudspeaker.......................16
Light emitting diode (LED) ......................16
Connecting peripherals .........................16
Keyboard (KYBD)...........................17
Scanners and scales (COM1 - COM4*)................18
Customer display (COM2* or COM4*) ................18
Cashier display (COM3*) .......................18
Monitor ................................19
TFT - LCD display...........................19
Connecting standard PC peripherals (COM1) ............20
Network ................................20
Modular printers ...........................20
Cash drawer (1,2)...........................21
USB (Universal Serial Bus) ......................21
Page 4
BEETLE /NetPOS - the components ..........22
Overview .................................22
Floppy disk drive .............................24
General ................................24
Inserting a disk ............................25
Removing a disk ...........................25
Power Supply ..............................25
Configuration variants ..................27
Submodules for the CPU.........................27
LAN Adapter 10/100 MBit/ LAN Controller 10/100 MBit .......27
CRT- or TFT-adapter .........................27
Installing the submodules when using a TFT/CRT adapter......28
Installing the submodules .......................29
Change of the hard disk .........................29
Retail Software ......................31
Wincor Nixdorf store solutions ......................31
Platforms and products .........................32
Microsoft ...............................32
Linux .................................33
Technology evaluation ........................33
Starting up the system..................34
Start and runup behaviour ........................34
Appendix .........................37
Technical data for the BEETLE /NetPOS ................37
Installation BA7x on BEETLE /NetPOS .................38
Supplement ..............................41
Glossary .................................42
Abbreviations...............................44
Page 5
Manufacturers Certification
The device complies with the requirements of the EEC directive 89/336/EEC with regard to ‘Electromagnetic compatibility" and 73/23/ECC “Low Voltage Directive”.
Therefore, you will find the CE mark on the device or packaging.
Tested Safety
The POS system has been provided with the symbol for “Tested Safety”.
In addition, the BEETLE has received the UL symbol and cUL symbol.
FCC-Class A Declaration
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Le présent appareil numérique ne génère pas de bruits radioélectriques dépassant les limites applicable aux appareils numériques de la “Class A” prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
1
TESTED SAFETY
geprüfte Sicherheit
Page 6
Important notes
The modular POS system BEETLE /NetPOS conforms to the current safety standards for data processing equipment.
n
If this device is taken from a cold environment into the operating room, moisture condensation may form. The device must be absolutely dry before being put into service; an acclimatization period of at least two hours must therefore be observed.
n
This device is equipped with a safety-tested power cable and may be connected only to a prescribed grounded-contact power socket.
n
When setting up the device, ensure that the power socket on the device and the grounded-contact power socket are easily accessible.
n
To disconnect the device from the supply voltage completely, switch off the device and disconnect the power plug.
n
Ensure that no foreign objects (c.g. office clips) find their way into the device, as this may lead to electric shocks or short-circuits.
n
Never plug in or unplug data communication lines during thunderstorms.
n
Protect devices from vibrations, dust, moisture and heat.
n
Always dispose of used parts, such as batteries, in an environmentally safe manner.
n
The lithium battery must be disposed of in accordance with local regulations for special waste.
n
In emergencies (e.g. damaged housing or damaged power cable, penetration by liquids or foreign bodies), the device must be switched off immediately, the power plug disconnected and the Customer Service of Wincor Nixdorf (WN) or your dealer must be notified.
n
The device may only be repaired by authorized qualified personnel. Unauthorized opening of the device and inexpertly carried-out repairs may not only seriously jeopardize the safety of the user, but also cancel all warranty and liability agreements.
IMPORTANT NOTES
2
Page 7
n
You should connect your BEETLE or other IT-devices only to poer supply systems with serarately guided protective earth conductor (PE). This kind of electricity system is known as TN-S network. Do not use PEN conductors!
n
Please also observe the recommendations of the norm DIN VDE 0100, Part 540, Appendix C2 as well as EN50174-2, §5.4.3. Thus you can help to avoid possible malfunctions.
3
IMPORTANT NOTES
Page 8
Introduction
The BEETLE /NetPOS is the compact, powerful and economical basis for your POS system.
The BEETLE conforms to the PC industry standard. Powerful processors ensure a quick processing of all operations.
You can connect a variety of different peripheral devices to your BEETLE and even the choice of the software is not limited to a certain product.
Optional the BEETLE /NetPOS can be equipped with a floppy disk drive or a memorycard adapter, a hard disk or a compact flash.
This provides you with a considerable degree of flexibility when arranging the configuration of your POS system.
The BEETLE can also be connected to a network once an appropriate network card has been installed.
In the event of a mains voltage failure, the version with battery and corresponding software enables you to save the data by means of a controlled program shutdown.
Whatever configuration you need: Wincor Nixdorf offers the right solution. So, whenever you want to expand your BEETLE /NetPOS, please contact your Wincor Nixdorf International GmbH branch office or your dealer.
INTRODUCTION
4
Page 9
About this manual
This manual describes the modular POS system BEETLE /NetPOS. This documentation is intended to help you work with the POS system and
to serve as a reference work. The detailed table of contents help you find the desired information quickly and easily.
The first section describes
n
everything you need to do before switching on the POS system and
n
how to connect peripherals to the BEETLE /NetPOS.
The second section contains
n
a brief overview of the components of your BEETLE POS system. Here, you will also find a detailed description of recurring actions, for example, how to use the disks.
The third selection provides
n
a brief overview of the Wincor Nixdorf Retail Software.
The Appendix
n
contains the most important technical data, a glossary and a list of
abbreviations. Notes in the manual are marked by this symbol. This symbol is used for warnings.
The type and scope of application programs depend on the customer’s own selection; therefore, software will not be discussed further in this manual.
Separate manuals are included in the scope of the connectable peripherals. For this reason, a more detailed description of these devices will not be provided here. For more information, see the relevant manuals.
Care of the BEETLE /NetPOS
Clean your BEETLE /NetPOS at regular intervals with a suitable plastic-surface cleaner. Make sure that the power plug is disconnected, connector cables are unplugged and that no liquid finds its way into the device.
5
ABOUT THIS MANUAL
Page 10
Recycling the BEETLE /NetPOS
Environmental protection does not begin when it comes time to dispose of the BEETLE; it begins with the manufacturer. This product was designed according to our internal norm “Environmental conscious product design and development”
The modular BEETLE /NetPOS System is manufactured without the use of CFCs and CCHS and is produced mainly from reusable components and materials.
The processed plastics can, for the most part, be recycled. Even the precious metals can be recovered, thus saving energy and costly raw materials.
Please do not stick labels onto plastic case parts. This would help us to re-use components and material.
You can protect our environment by only switching on your equipment when it is actually needed. If possible, even avoid the stand-by-mode as this wastes energy, too. Also switch your equipment off when you take a longer break or finish your work.
At this time, there are still some parts that are not reusable. Wincor Nlxdorf guarantees the environmentally safe disposal of these parts in the Recycling Center, which is certified pursuant to ISO 9001 and ISO 14001.
So don’t simply throw your BEETLE POS system on the scrap heap when it has served its time, but take advantage of the environmentally smart, up-to-date recycling methods!
Please contact your competent branch or the department environmental protection for information on how to return and re-use devices and disposable materials under the following fax number:
Fax: +49 (0) 5251 826309 We look forward to your fax.
RECYCLING THE BEETLE /NETPOS
6
Page 11
Warranty
Wincor Nixdorf guarantees a limited warranty engagement for 12 months beginning with the date of delivery. This warranty engagement covers all those damages which occur despite a normal use of the product.
Damages because of
n
Improper or insufficient maintenance,
n
Improper use of the product or unauthorized modifications of the
product,
n
Inadequate location or surroundings will not be covered by the warranty. All parts of the product which are subject to wear and tear are not included
in the warranty engagement. Please order spare parts at the Wincor Nixdorf customer service.
7
WARRANTY
Page 12
BEETLE /NetPOS
Overview
You can connect a variety of peripherals to your modular POS system BEETLE /NetPOS and thus implement a wide range of expansion stages. You can connect a two or four-line alphanumeric customer display and a four line cashier display. Alternatively you can connect Flat screens, such as BA69 (VGA/4), BA70 (b/w) or BA71 and BA72 (color), use various types of scanners such as distance, touch or stationary scanners, use scales and scanner scales (please take into account the official certification regulations), connect various printers, use POS keyboards with or without a swipecard reader, use different types of cash drawers, connect a monitor, install the POS workplace SNIkey, integrate the BEETLE /NetPOS in a network.
This means that the BEETLE /NetPOS can meet your requirements at all times, without having to exchange the complete system for a new one, thus saving you time and money.
The illustration below show you how your modular POS system can grow ­from a scanner to integration in a network.
8
Page 13
BEETLE /NetPOS Peripherals
9
OVERVIEW
PrinterScanner
Cash drawer
Scales
Monitor
Flatscreen display
Keyboard
BA69
Customer or cashier display
SNIkey
Page 14
BEETLE /NetPOS in a network
OVERVIEW
10
Ethernet 10/100 Base T
Server
BEETLE /NetPOS
Page 15
Before switching on the System
Unpacking and checking the System
Unpack the parts and check to see whether the delivery matches the information on the delivery note.
The cardboard box contains the basic unit and a country-specific package. In addition, the basic unit may be equipped with the components network card, diskette drive, hard disk and VGA–card, LCD adapter, AT-COM board, PCMCIA adapter or a combination of these components.
Should you notice
n
any transport damages or
n
discrepancies between package contents and delivery ticket or
n
functional defects, please inform your contracting parties or the marketing outlet of Wincor
Nixdorf International GmbH immediately. Please indicate the number of your delivery ticket and delivery ticket position and serial number of the respective device. The serial number can be found on the label illustrated below which is located at the rear of the housing; it may be necessary to remove the cable cover.
The serial number is located on the label below the bar code.
It is absolutely necessary to check the function of the original equipment before you perform any changes (e.g. by installing an expansion card). Only then is it possible to accept a functional defect as a claim.Transport the device only in its original packaging (to protect it against impact and shock).
We recommend saving the original packaging for transport at a later time (protection from impact and shock).
11
BEFORE SWITCHING ON THESYSTEM
Wincor Nixdorf
Made in Singapore
WN0199901107
BEETLE NetPOS 017500 000000
100-120V / 200-240V 50/60 Hz 5/3 A
Page 16
Setting up the device
Set up the BEETLE /NetPOS POS system where it will not be exposed to extreme environmental conditions. Protect the device from vibrations, dust, moisture, heat and strong magnetic fields.
Make sure that the side ventilation slots on the BEETLE /NetPOS and the external power supply are not obstructed in order to ensure that the device has sufficient ventilation.
The fitting depth may be equal to the overall depth of the equipment including the cable cover, that is, 350 mm.
The minimum distances at the left and the right side of the external power supply are 50 mm.
If the equipment is to be fitted, you must ensure that the specified minimum distances are maintained and constant ventilation is provided. The imme­diate ambient temperature of the system must not exceed 40° C/104 °F. These requirements are met, for example, if the equipment is not built into an enclosed piece of furniture.
Under extreme ambiente conditions a temperature of 60° C / 140° F can develop on the left side of the housing of the BEETLE /NetPOS. This is
BEFORE SWITCHING ON THESYSTEM
12
50 mm
50 mm
50 mm
50 mm
0
Page 17
inoffensive and does’t provoke any limitation of the functionality of your BEETLE /NetPOS.
Cabling of the BEETLE /NetPOS
Follow the steps below in the order given when installing devices:
n
The cable cover must be removed, if present.
n
Plug one end of the power cable into the external power supply and
connect the other end to the main power supply.
n
Plug one end of the other power cable into a grounded-contact power
socket of the external power supply and the other into the socket of the
BEETLE /NetPOS.
n
Plug in and secure the data cable. Always make sure that the system is switched off when you do cabling
works.
Disconnecting cables
Never unplug a cable by pulling on the cable itself; always take hold of the actual plug. Follow the procedure below when disconnecting cables:
n
Turn off all power and equipment switches.
n
Remove the cable cover.
n
Unplug all data communication cables from the sockets of the data
networks.
n
Unplug all power plugs from the grounded-contact power sockets.
n
Unplug all cables from the devices.
With MINI-DIN plugs, the plug remains inserted until released.
Pull the plastic covering from the connecting socket with your thumb. The lock is released. The metal of the plug is visible.
RJ12 plugs lock in when you insert them. To release them push the latch under the plug to the top.
13
BEFORE SWITCHING ON THESYSTEM
Page 18
The D-sub typ connector or CRT (VGA) connector is used for parallel or serial interfaces. Release the connector by loosen the two screws.
Take hold of the USB connector housing and release the connection.
Loosen the plug of the USB powered connector by pressing the plastic latch.
Release the TFT connector by pressing the latches on the left and right inwards.
Mounting the cable cover
The scope of supply of your BEETLE /NetPOS includes a cable cover. Before mounting the device, you should first remove the cable openings where necessary. Tools are not required as the plastic parts can be removed by hand.
BEFORE SWITCHING ON THESYSTEM
14
Page 19
In order to mount the cable cover, insert it in the guide and turn it to the BEETLE box. Press from the inside against the exterior and pull it to the rear side until it is fixed in the second pin on the back of the BEETLE box.
In doing so, ensure that the cable cover does not fit askew.
Connecting to the mains power supply
All devices belonging to the modular BEETLE /NetPOS system that have a separate power cable must be connected to the same electric circuit.
n
Make sure that all data cables on the system unit and peripherals are
connected correctly.
n
Make sure that the DC cable is connected to power supply and to
system unit.
n
Plug all power cables belonging to the BEETLE and the peripherals into
the grounded-contact power sockets.
You can now switch on the BEETLE /NetPOS by means of the switch on the external power supply. Push the ON/OFF button at the front of the box.
The power supply can be connected to all standard power supply networks. The unit adjusts automatically to the respective voltage. The maximum output of the power pack is 150 W.
15
BEFORE SWITCHING ON THESYSTEM
ON/OFF button
ON/OFF switch
Page 20
Basic settings
Ex works, the BEETLE /NetPOS is configured to your order. Your configuration must be subsequently adapted to support supplementary devices such as scanners. For more information, contact the WN branch office responsible for your area.
Adjusting the loudspeaker
You can set the volume as desired by means of a menu described in the manual “BEETLEPOS Motherboard”, chapter “BIOS Setup”.
Light emitting diode (LED)
The left LED green (POWER) lights when the BEETLE /NetPOS is switched on.
The right, yellow LED (HDD) lights up while the hard disk is being accessed.
Connecting peripherals
The peripherals mentioned here are available as options and are not part of the basic configuration. A separate manual is provided for each of the connectable components. For more detailed information, please consult the relevant documentation.
The figure shows the back panel of the BEETLE /NetPOS with the locations of the connecting sockets and connecting plugs. If you wish to connect a monitor to an onboard video controller, however, you must also have an adapter.
CRT and TFT interfaces are used alternatively. Connecting peripherals with the system switched on is not allowed.
CONNECTING PERIPHERALS
16
Page 21
Rear panel of the BEETLE /NetPOS (optional USB plus)
Rear panel of the power supply
Keyboard (KYBD)
The BEETLE /NetPOS has a 6-pin mini-DIN jack for connecting a keyboard. Make sure that the connector is plugged firmly into the socket to prevent malfunctioning. Power is supplied to the keyboard via this socket. If you wish to connect a standard PC keyboard with DIN connector, you must use a special adapter cable, obtainable from the WN branch office responsible for your area.
When removing cables with locks, please grip the cable at the connector housing.
17
CONNECTING PERIPHERALS
KYBD
COM1
VGA
COM4*
COM3*
COM2*
USB
LAN/ASYN
LPT1
SPK
MIC
DC IN
Power Connector
Subconnector Mains
0
I
DC 24V
100-120V~2Amax. 200-240V~1Amax.
12 cashdr only
ON/OFF Cash Drawer 1, 2
POS Printer Power
Mains Socket
USBplus (3 x 12V)
Page 22
Scanners and scales (COM1 - COM4*)
Depending on the systems configuration, scanners without an independent power supply are connected to the COM2*, COM3* or COM4* serial interface (standard setting COM3*). Connect scales with their own power supply to the COM1 interface. COM1 is designed as a 9-pin D-sub plug, whereas COM2* - COM4* are 9-pin D-sub jacks. Make sure that the scanner connector is plugged securely into the socket to prevent possible malfunctioning.
If you connect scales to the BEETLE /NetPOS which are not supplied by Wincor Nixdorf, you must obtain a licence for the driver software.
The COM2 interface is without effect if the onboard TFT adapter with touch screen function is installed.
Customer display (COM2* or COM4*)
With the BEETLE /NetPOS, and depending on the system´s configuration, the customer display is connected to either the COM2* or COM4* serial interface. The interface connection is a 9-pin D-sub jack. Make sure that the connector for the customer display is screwed firmly to the socket to prevent possible malfunctioning. Power is supplied via this jack.
Cashier display (COM3*)
Connect the cashier display to the serial interface COM3*. This port is a 9-pin D-sub jack.
Make sure that the connector for the cashier display is screwed firmly to the socket to prevent possible malfunctioning.
CONNECTING PERIPHERALS
18
Page 23
Monitor
If a CRT adapter is installed, you can connect a monitor to the system via the 15-pin D-sub jack on the CRT adapter. The power supply of the monitor is done by the rubber socket of the external power pack. The socket is situated at the front of the power pack.
A LCD screen can be connected alternatively if a TFT adapter is installed.
TFT - LCD display
If a TFT adapter is installed you can connect a SNIkeyTFT/ BA71/ BA72/ BA73 to the BEETLE /NetPOS without using an ISA slot. Connect the 50-pin data cable of the LCD to the system. The signals for the touch screen function and the power supply are also made via this cable. To implement the touch screen functionality for the COM2 interface also for the COM1 interface by using a D2 CPU, you have to change some system settings ( see manual “BEETLE POS Motherboard”, chapter “Technical data”).
If the display is equipped with a keyboard cable connect this with the KYBD terminal. You can only connect one keyboard cable to the BEETLE /NetPOS
at a time - either that of the LCD or that of the free standing
keyboard (e.g. PC keyboard, TA57, TA61) To find out how to connect a second keyboard, refer to the user guide of the
display.
19
CONNECTING PERIPHERALS
Page 24
Connecting standard PC peripherals (COM1)
You can connect supplementary standard peripherals to the BEETLE /NetPOS via the COM1 serial interface.
Make sure that all supplementary devices have been tested for RFI suppression pursuant to the legal requirements of your country.
Network
If a network board is installed, the system can be connected to a network (LAN) from the POS terminal back panel.
Modular printers
The standard parallel interface LPT1 is intended for connecting a printer.
Appropriate POS printers can also be connected via the low-voltage jack 24V, max. 2A at the external power supply. A connecting cable with a HOSIDEN plug is required for this.
Do not connect the HOSIDEN plug when the system is turned on, this can lead to an automatic reboot of the system.
CONNECTING PERIPHERALS
20
Page 25
Connect only cable to the 24V connector which are marked with DP-1 or DP-2.
Cash drawer (1,2)
The BEETLE /NetPOS has two RJ12 sockets at the external power supply for connecting cash drawers. Make sure that the connector is plugged firmly into the socket to prevent malfunctioning. RJ12 plugs lock in when you insert them. Power is supplied to the cash drawer via this socket, +24V +5% / -10%.
Connecting daisy chained cash drawers and 12V OEM-drawers is prohibited!
USB (Universal Serial Bus)
To this USB interface you can connect a variety of USB-peripherals, e.g. scanners and scales.
Only connect devices equipped with a shielded cable to the USB-interface.
21
CONNECTING PERIPHERALS
Page 26
BEETLE /NetPOS - the components
Overview
The following figure shows the outside of the BEETLE /NetPOS.
OVERVIEW
22
LEDs (POWER, HDD)
ON/OFF
Floppy Disk
Page 27
The figure below shows the inside of the BEETLE /NetPOS.
23
OVERVIEW
Floppy Disk
TFT Adapter
Hard Disk
SD RAM
Carrier for Hard Disk Drive, Floppy Disk Drive, CD ROM Drive
Page 28
Floppy disk drive
General
The BEETLE /NetPOS is equipped with a floppy disk drive for 3.5" disks. The LED at the drive lights up whenever the system accesses the drive.
The disks can be used for a variety of applications, such as:
n
Loading programs
n
Saving data (e.g. daily sales figures)
n
Access control (electronic key)
The disk can be write protected to protect your data from accidentally being overwritten. The slide is located at the bottom left of the diskette.
FLOPPY DISK DRIVE
24
Writing is possible
Writing is not possible
Page 29
Inserting a disk
Hold the disk so that the arrow symbol is at the top and points away from you. Now insert the disk in the drive slot provided. The disk has been correctly inserted when the grey ejection button has popped out.
Removing a disk
Press the ejection button next to the drive slot. You can now remove the disk.
Never remove the disk while the drive is being accessed, i.e. when the LED indicator for the drive is illuminated. Otherwise, you could damage the drive and the disk.
Power Supply
The power supply automatically adjusts itself to the particular voltage. The power output of the power supply is maximum 150 W.
The power cord receptacle and the ON/OFF switch are located on the back of the power supply. At the front side of the BEETLE /NetPOS you will find the ON/OFF button which will turn on the system if the ON/OFF switch at the rear side of the external power supply is in the position ON. Pushing the ON/OFF button again (push at least 4 sec.) will turn the system into the Stand by mode.
25
POWER SUPPLY
ejection button
Page 30
Rear panel of the power supply
POWER SUPPLY
26
0
I
DC 24V
100-120V~2Amax. 200-240V~1Amax.
12 cashdr only
ON/OFF Cash Drawer 1, 2
POS Printer Power
Subconnector Mains
Mains Socket
ON/OFF button ON/OFF switch
Page 31
Configuration variants
Submodules for the CPU
Various controllers can be plugged in on the CPU. The following is a brief description of the available options:
LAN Adapter 10/100 MBit/ LAN Controller 10/100MBit
Ex works the BEETLE /NetPOS is equipped with the LAN adapter 10/100 Mbit for the incorporation in an Ethernet Network. Alternatively a
LAN-Controller 10/100 MBit can be plugged.
CRT- or TFT-adapter
Both adapters must be installed alternatively. You can connect either a CRT monitor or a TFT-LCD module with optional touch screen functionality. When installing a TFT adapter with touch screen functionality make sure that the internal loudspeaker will be taken off to activate the loudspeaker in the screen display (see chapter installation in the manual of the screen display) and the touch functionality will be activated via BIOS Setup (see the manual “BEETLE POS Motherboard”). The according COM interface is no longer valid for external use. If the BEETLE system is pre-installed ex works, the COM interface will be delivered with a cover. If a D2 CPU is installed, the COM1 interface is usable.
27
SUBMODULES FOR THE CPU
Page 32
Installing the submodules when using a TFT/CRTadapter
First ensure that the system is switched off and that the power connector is disconnected. Loosen the screws at the rear side (see arrows).
Then lift off the top cover. When using a TFT or CRT adapter, loosen the screws on the rear side of
the adapter (see arrows).
Loosen the connector of the adapter from the motherboard, loosen the screws andshift the adapter through the open slot . Remove the metal cover of the LAN/ASYNC interface .
SUBMODULES FOR THE CPU
28
Page 33
Plug in the submodule (see drawing).
Fix the submodule (here LAN controller) with two screws at the rear side of the BEETLE system and push the TFT adapter or CRT adapter through the slide back in the right position . After connecting it with the motherboard fix the adapter with the two screws.
Installing the submodules
Proceed according to the description in the section before, however without installation of the TFT or CRT adapter.
Change of the hard disk
To change the hard disk open your BEETLE /NetPOS as described on the pages before.
29
CHANGE OF THE HARDDISK
LAN Controller
Page 34
Pull out the connectors, lift up the hard disk/ floppy disk.
Lift the clamp (1) and push the hard disk out of the carrier (2).
Loosen the screws and change the hard disk. Tighten the screws again.
Plug in the connectors again and close the cover. Plug the power cable (external power supply) and switch on the system.
CHANGE OF THE HARDDISK
30
Page 35
Retail Software
The market for retail store solutions presents a broad array of requirements for the functions in these solutions as well as for the software technologies used. Moreover, the software and hardware is used internationally, and must meet a wide range of regional requirements. This means, for example, that solutions that fulfill the regional requirements of Central Europe may turn out to be inadequate for Asia or Latin America. Wincor Nixdorf provides customers worldwide with standard products appropriate to the commercial and technical complexity of their organizations. In keeping with this strategy, Wincor Nixdorf has defined a portfolio of in-store solutions that accommodates this variety of requirements. The portfolio offers in-store solutions for the different operating system platforms that are prominently used worldwide (Microsoft and Linux), and also offers varying degrees of solution complexity. Besides demanding products that will remain viable in the future, today’s retail customers also require that a solution provider offer other services, such as project management, customization and integration services, as well as advice in the selection of basic core technologies.
Wincor Nixdorf store solutions
As an international product provider, we are oriented to market developments and standards that are available worldwide, allowing us to offer our customers open solutions and services with guaranteed viability into the future.
Software must of course meet the customers’ needs, and these can often vary greatly. But for the software to be a long-term success, its design and implementation must also take into account the fundamental trends and standards that are emerging in the market. Only if you stay open to the dynamics of retail, it can be ensured that new commercial trends will be reflected within the scope of the solutions provided. To accommodate these dynamics, Wincor Nixdorf must have the appropriate technical expertise. When working on product development, projects or consulting, this expertise is essential to effectively meet current as well as future requirements.
31
WINCOR NIXDORF STORE SOLUTIONS
Page 36
Platforms and products
Solution platforms today are expected to utilize state-of-the-art, standardized operating systems. Some of the decisive factors in selecting an operating system in the retail trade include:
n
An operating system should provide software administration mechanisms to help minimize the total cost of ownership
n
The flexibility of an operating system for use with different hardware and peripherals
n
Global availability to ensure complete coverage, as well as
n
Scalability with regard to user requirements.
In light of these criteria, the Microsoft operating systems have established themselves in the market, and the Microsoft Windows NT platform is now positioned as an important technological factor.
However, the growing discussion of operating system scalability, as well as the demand for continued reduction of the total cost of ownership, have led to the emergence of other operating systems. The strongest trend has been to Linux. Regardless of the industry involved, Linux offers itself as an interesting supplemement to the world of Microsoft.
In view of this trend, Wincor Nixdorf has defined a software strategy that accommodates both Linux and the popular Microsoft platform:
Microsoft
Wincor Nixdorf currently offers two products for retail customers based on the Microsoft platform - the successful POSition store solution and the next-generation Trading Post software.
With POSition, Wincor Nixdorf offers an optimized solution for use in the self-service food and self-service non-food market segments. It is a flexible and highly integrative solution. Meeting the needs of its international clientele, it is based on a client/server architecture with MS-DOS at the POS terminals and a Windows NT-based server.
Trading Post presents itself as an object-based POS solution which uses the Microsoft Windows NT operating system throughout. With standardization concepts for interfacing POS peripherals (OPOS), an
PLATFORMS AND PRODUCTS
32
Page 37
innovative, modular customizing concept and a graphical user interface at the POS terminal, Trading Post is positioned in markets with demanding requirements for system architecture and application versatility.
Linux
With CALYPSO, Wincor Nixdorf provides an international, high-performance sales system for the control and administration of sales activities in the self-service food and self-service non-food market segments. It is based on a Linux server and MS-DOS or Linux clients. The system architecture and platform guarantee optimal security and performance. CALYPSO is one of the first retail solutions with a homogenous Linux platform throughout.
Technology evaluation
The further development of Wincor Nixdorf retail solutions takes place in dialog with its customers. Before being included in existing products, new trends and technologies are carefully examined with regard to their readiness for the market. To ensure market acceptance and market orientation in the selection of technologies, Wincor Nixdorf conducts technology evaluation projects with its customers and partners. This significantly reduces technological risks.
33
PLATFORMS AND PRODUCTS
Page 38
Starting up the system
The configuration label shows you the equipment included in your modular BEETLE /NetPOS system. The label is located at the underside of the BEETLE /NetPOS. The data specified there are required for entering the setup parameters (see section Setup in the manual “BEETLE POS Motherboard”).
Start and runup behaviour
After installing the BEETLE /NetPOS, switch on the POS system using the ON/OFF button on the front panel and the power switch on the power supply.
The system first performs an automatic self-test to test its basic functions. For example, you may see the following message (irrespective of processor
type) on the four-line cashier display or on the monitor:
xx/xx is the place holder of the BIOS version number The system then determines the medium from which the operating system
and POS application are to be booted. Each medium is assigned a logical drive according to the configuration of your BEETLE /NetPOS.
The following media can be assigned a drive:
n
Disk
n
Network
n
Hard disk
n
Memory card
n
CD-ROM (not for BEETLE /NetPOS)
The logical drives are designated A:, B:, C: and D:.
START AND RUNUP BEHAVIOUR
34
WN POS xx/xx Date
Page 39
If the system is to be booted from disk, this medium must always be assigned drive A:. The network is always assigned to the C: drive during the runup procedure. The hard disk can be assigned to the C: or D: drive. The system can only be started from the hard disk if the disk has been configured as the C: drive.
Corresponding to the Setup configuration the modular BEETLE /NetPOS POS system can be booted from the following drives:
n
Floppy disk in drive A:
n
Hard disk in drive C:
n
CDROM in EL TORITO format
n
Network adapter with BOOTPROM Please mind that the storage medium must be system-boot-capable. The following priorities are adjusted:
Floppy disk (A:) High priority Network (C:) Medium priority Hard disk (C:) Low priority
As standard the POS system always attempts to boot from a disk first if it is inserted in the respective drive.
If the POS system does not find a disk resp. a CD-ROM in drive A:, it automatically continues the loading process from drive C:.
If drive A: contains a disk on which no operating system is stored, the POS system cannot be booted. In this case, either replace the disk with one that is system-boot-capable or remove the disk altogether.
The operating system responds with additional messages on the cashier display or monitor, as shown in the illustration below.
35
START AND RUNUP BEHAVIOUR
C >P:
Page 40
If the operating system has started up without error, the POS application software is automatically booted if necessary.
A message is displayed as soon as the BEETLE /NetPOS is ready for operation. For more detailed information, see the description of your application program.
TECHNICAL DATA FOR THEBEETLE /NETPOS
36
Page 41
Appendix
Technical data for the BEETLE /NetPOS
37
TECHNICAL DATA FOR THEBEETLE /NETPOS
Box
Width 288 mm 11.34 in Depth 255 mm 10.04 in Height 58 mm 2.24 in Cable cover 80 mm 3.15 in
Power Supply
Width 162 mm 6.38 in Depth 223 mm 8.87 in Height 80 mm 3.15 in
Weight
Box approx. 3.5 kg Power supply approx. 2.5 kg
Climatic category
Operating IEC 721-3-3 Class 3K3 +5°C to +40°C Transport IEC 721-3-2 Class 2K2 -25°Cto+60° C Storage IEC 721-3-1 Class 1K2 +5°Cto+40° C
Input voltage 100 - 120 VAC
200 - 240 VAC
Max. power consumption 3A: 200- 240V
5A: 100- 120V
Frequency of system voltage 50-60Hz
Page 42
Installation BA7x on BEETLE /NetPOS
Loosen the screws , slightly lift up the cover of the BEETLE /NetPOS and pull out forward .
Take the pre-mounted cover, put it on the BEETLE /NetPOS and push it to the rear. Fasten the screws.
INSTALLATION BA7X ON BEETLE/NETPOS
38

Page 43
Open the cable cover of the display (see arrow) on the rear side and remove it. You see the cable connection.
Put the grey connection part into the display swivel joint and fix it with the screw .
Add the swivel joint into the mounting foot. Press your finger on the screw , so that the grey connection part is in the back. Shift the display into the mounting foot until A fits in B.
39
INSTALLATION BA7X ON BEETLE/NETPOS
A
B
Page 44
Fasten the swivel joint at the display (see figure). Plug the cable connection and reinsert the cable cover.
Tilt the display backwards. Set the locking noses of the impact-blind into the support angles of the swivel joint and press the impact-blind until it is locked .
Install the impact-blind to avoid injuries.
INSTALLATION BA7X ON BEETLE/NETPOS
40
Page 45
Supplement
It is possible to lay an additional cable into the mounting foot beside the display cable . Minimum distances are depending upon type of cable ( cable of swipe card reader, cable of smartcard reader, values±5mm apply to BA70, BA71 and BA72).
41
INSTALLATION BA7X ON BEETLE/NETPOS
150 mm
140 mm
150 mm
320 mm
Page 46
Glossary
Bit
A bit is a binary digit (0 or 1). It is the smallest unit used in data processing.
BPP
Bits per Pixel, depth of colour.
Controller
Serves to control data input and output in a data processing system or between a computer and the connected peripherals.
CPU
Abbreviation of central processing unit. It includes the main components of a data processing system. The CPU monitors all operations and provides data and programs. It comprises the control unit for input and output, the computer and the main memory, divided into ROM and immediate access storage.
Interface
Designates the transition point between different hardware units and software units or between hardware and software units of computers or their peripherals.
JEIDA
Abbreviation of Japan Electronic Industry Development Association. Industry standard for memory cards.
Operating system
Refers to all programs that are a component of a computer and are required for operating the system and executing application programs.
PCMCIA
Abbreviation for Personal Computer Memory Card International Association. Industry standard for memory cards.
Plug and PLay (PnP)
PnP means the automatic recognition of hardware components by the system. Thus the installation, integration and configuration of new components is made substantially easier.
GLOSSARY
42
Page 47
Peripherals
Devices serving as an input/output device or storage for a computer. This includes, for example, document readers, keyboards, printers and disk storage.
Server
This is a computer connected to a local network and whose services are available to all of the network subscribers, e.g. a print server for printing the data from all of the network subscribers on the printer connected to the server.
VGA
Stands for Video Graphics Array and is the interface for connecting colour monitors.
43
GLOSSARY
Page 48
Abbreviations
AT Advanced Technology ATA AT-Attachment BIOS Basic Input Output System COM Communication Port CPU Central Processing Unit CRT Cathode Ray Tube cUL canada Underwriters Laboratories DIMM Dual Inline Memory Module ECP Extended Capability Port EPP Enhanced Parallel Port EPROM Erasable Programmable Read Only Memory FD Floppy Disk GS “Geprüfte Sicherheit” (Tested Safety) HDD HardDisk Drive HFT High Frequency Table HSF Hash File Access Method IDE Integrated Drive Electronic ISA Industrial Standard Architecture ISO International Standardization Organization JEIDA Japan Electronic Industry Development Association LAN Local Area Network LBA Logical Block Addressing LED Light Emitting Diode LPT Line Printer OEM Original Equipment Manufactures PCI Peripheral Component Interconnect PCMCIA Personal Computer Memory Card Intern. Association PnP Plug and Play RAM Random Access Memory ROM Read Only Memory SCSI Small Computer SystemsInterface SD RAM Synchronous Dynamic Random Access Memory SIMM Single In LineMemory Module SRAM Static Random Access Memory SVGA Super Video GraphicsArray TFT Thin Film Transistor UPS Unbreakable Power Supply UL Underwriters Laboratories USB Universal Serial Bus XMS ExtendedMemory Specification
ABBREVIATIONS
44
Loading...