Panelmeter 
 EX20xx, EX30xx 
Attention! Read this first! 
Read through the Instructions manual carefully. The guarantee becomes null and void if damage 
or injury results from non-compliance with these instructions. We cannot assume any liability for 
consequential damage or injury. 
Manual 

Dear Customer, 
Thank you for buying the EX-Panelmeter. Your EX-Panelmeter is a product which was 
manufactured with state-of-the-art technology. 
This product conforms to valid European and national safety guidelines. Conformity 
has been certified; the relevant documents are in the manufacturer's possession. 
To maintain this standard and ensure safe operation, you as user must comply with the 
Instructions manual. 
Our Internet site at www.bue.de will help you answer Frequently Asked Questions and 
provide tips and updated handbooks. 
This symbol indicates important instructions which must be followed. 
Imprint 
These Instructions for Use were published by Beckmann+Egle GmbH, Kernen. All rights reserved. Neither this publication nor any part of it 
may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, 
recording or otherwise, without the publisher's prior consent in writing. 
These Instructions for Use are based on the technology used at the time of printing. Changes in technology and equipment are reserved. 
Revision history 
Explanation for setting decimal point 
Added changes for EX32xx (voltage protection) 
Introduction ......................................................................................................................................... 2 
Safety Information ............................................................................................................................... 3 
Warranty ............................................................................................................................................. 3 
Description .......................................................................................................................................... 4 
Functions ............................................................................................................................................. 4 
Initial Operation ................................................................................................................................... 4 
Maintenance, proper disposal .............................................................................................................. 4 
Specifications ...................................................................................................................................... 4 
Dimensions ......................................................................................................................................... 5 
EX-Voltage Modules (Voltmeters) ....................................................................................................... 6 
EX-Current Modules (Currentmeters) .................................................................................................. 7 
Adaption and Adjustment .................................................................................................................... 9 
Technical Data .................................................................................................................................. 11 
Copyright BECKMANN+EGLE GmbH, All Rights Reserved.  Page 2  Internet: www.bue.de 

Please observe the following when using the product: 
 This Panelmeter left our factory in perfect technical condition. To preserve this state 
and ensure safe operation, the user must observe the safety instructions and 
warnings. 
 Electronic components and accessories do not belong into child hands. 
 Accident prevention regulations issued by the industrial trade associations and 
pertaining to the safe use of electrical appliances and equipment on registered 
commercial premises must be complied with. 
 A responsible person, trained in the use of electrical equipment, must be present 
when this product is used in schools, further education classes, DIY and self-help 
groups. 
 Turn power OFF before making any changes to the hardware-configuration. 
 Use in adverse environmental conditions is prohibited. 
Such adverse conditions may include: 
- areas exposed to moisture or high levels of humidity, 
- environments containing dust and combustible gases, vapours or solvents 
- during lightning or weather likely to induce strong electrical fields. 
 The user is obliged to ascertain whether the product is suitable for the purpose for 
which he intends to use it. 
 Parts leading high voltage (e.g. inverter for backlight) must be secured against 
unintentionally contact. 
 Electrostatic sensitive devices – observe precautions for handling. 
 The warranty covers the cost-free replacement or repair of faulty parts which can be 
proved to have resulted from the use of defective material or errors in production. 
Parts subject to normal wear and tear are specifically excluded from this guarantee. 
 We cannot accept any responsibility for any damage or injury resulting from the use 
of this product. 
 The customer accepts all costs for delivery and return of goods, and any charges 
which may apply in the event of machine failure or modifications to the device 
undertaken by us. 
 Additional claims are excluded. 
Copyright BECKMANN+EGLE GmbH, All Rights Reserved.  Page 3  Internet: www.bue.de 

Digital panel meters EX with and w/o illumination. The modules of the EX series were 
specially designed for build-in situations of housings and panels. Simple mounting and no 
need of galvanic separated support-voltage, those meters with high voltage and current 
precision are the real alternative for analog meters. They are useful in all areas where it is 
necessary to deliver reliable physical Data to operator.  
Measure and test engineering, solar technique and electronics, as well as machine- and 
apparatus engineering are typical area of application. 
The modules of the EX-Series offer following functions: 
digital snap-in instrument oft he EX-series are designed to measure directly 
electrical and non-electrical physical metrics. 
Digital-Instruments are used to avoid parallax error of analog instruments, to have 
a far higher resolution and ability to view the values from further distances. 
Please check the wiring before switching ON. 
Maintenance, proper disposal 
Please consider as well following advices: 
 For cleaning do not use carbon containing cleaners, nor benzine, alcohol or similar. 
 Damages caused by disregard of advices from instruction manual lapses warranty 
claims. 
The instruments do not need galvanic 
separated auxiliary voltage (common 
ground). 
(does not apply for EX2030 to EX2034!) 
The instruments display polarity 
automatically 
The position of the decimal point can be 
adjusted by option.. 
Exeedance of range are displayed by a 
single 1 or -1 (Overflow display). 
The modules of the series EX30xx have an 
built-in green-yellow LED-light(12V). 
Snap-In mounting for fixing and simple finish 
for housings and panels. 
The housing color is black. 
Copyright BECKMANN+EGLE GmbH, All Rights Reserved.  Page 4  Internet: www.bue.de 

Please consider the following table for frontplate opening : 
S = frontplate thickness 
X = frontplate opening width 
Y = frontplate opening height 
All dimensions in Millimeter. 
Copyright BECKMANN+EGLE GmbH, All Rights Reserved.  Page 5  Internet: www.bue.de 

EX-Voltage Modules (Voltmeters) 
Modules of the EX Series were specially designed for use in front panels and housings. 
Due to ease of mounting and no need of a galvanic separated auxiliary voltage, these 
exceedingly precise meters are a true alternative to conventional analog meters.  
Thus they are very useful in all applications where it is important to obtain reliable physical 
data to users. 
For EX2068, EX2069, EX2070, EX2071 and EX3068, EX3069, EX3070, EX3071: 
Für EX2020, EX2021, EX2022, EX2023: 
Copyright BECKMANN+EGLE GmbH, All Rights Reserved.  Page 6  Internet: www.bue.de 

Specialities (sample schematic) 
Current measuring with voltmeters (only with EX2068 / EX3068) 
Basically current measure is as well possible with voltage meter modules. For such, a 
so called „shunt-resistor“ is necessary. This option is already integrated in the current 
meter modules. To use Voltmeter modules use below schematic to avoid damage tot 
he modules. 
Important: The Measure-resistor (Shunt) has to be connected in the ground wire of 
the load! 
Voltage measuring (only with EX2068 / EX3068) 
 Measuring with separated ground wire! The voltage drop in the measure wire can be 
up to 300µV, depending the length. This is resulting in a displacement of the zeropoint. With below schematic this effect can be avoided. 
EX-Current Modules (Currentmeters) 
Modules of the EX Series were specially designed for use in front panels and housings. 
Due to ease of mounting and no need of a galvanic separated auxiliary voltage, these 
exceedingly precise meters are a true alternative to conventional analog meters.  
Thus they are very useful in all applications where it is important to obtain reliable physical 
data to users. 
Copyright BECKMANN+EGLE GmbH, All Rights Reserved.  Page 7  Internet: www.bue.de 

For EX2072, EX2073, EX2074, EX2075, EX2076 and  
EX3072, EX3073, EX3074, EX3075, EX3076: 
For EX2030, EX2031, EX2032, EX2033, EX2034: 
Connection Sample 
(Supply Voltage has to be separated from Measure Voltage) 
The modules EX2077 and EX3077 are not equipped with an integrated Shunt. Thus 
is valid the same schematic as for „Current Measuring with external shunt“  
(Specialities page 7). 
Copyright BECKMANN+EGLE GmbH, All Rights Reserved.  Page 8  Internet: www.bue.de 

Vehicle and Vessel Installation 
The maximum input voltage of the modules is up to 30V. Whereas in vehicles with 
12V on-board voltage occasionally higher voltages appear (mostly short term), but 
may result in damage of the module. 
The use of a so called VDR (voltage depending resistor) parallel to the supply voltage 
at the module will avoid damage.  
Those components are available at standard electronic distributors, sample type: 
EPCOS Type S05K17. 
 The EX30xx from production >01/2015 already include a overvoltage and reverse 
voltage protection circuit ! 
Supply Voltage for the Illumination of the 30xx 
 The illumination supply voltage of the modules EX 30xx is designed for 12V; the 
current consumption is about 7mA. Shall the modules be used with other supply 
voltage (i.e. 24V), a series-resistor need to be applied. 
Rv = Uv / Ib with Uv = (applied supply voltage - 12V) and Ib = current consumption 
illumination = 7mA, thus at a supply voltage of 24V the series-resistor shall be 
1,7kOhm. Whereas the used value can be between 1 und 2 kOhm, depending the 
desired brightness). 
 Module Revision 2009 and later 
Copyright BECKMANN+EGLE GmbH, All Rights Reserved.  Page 9  Internet: www.bue.de 

For EX2020, EX2021, EX2022, EX2023 and EX2030, EX2031, EX2032, EX2033, 
EX2024: 
For EX2068, EX2069, EX2070, EX2071 and EX2072, EX2073, EX2074, EX2075, 
EX2076: 
For EX3068, EX3069, EX3070, EX3071 and EX3072, EX3073, EX3074, EX3075,  
EX3076: 
Copyright BECKMANN+EGLE GmbH, All Rights Reserved.  Page 10  Internet: www.bue.de 

automatic negative signal 
configuration via soldering bridges 
14mW from Prod.Lot > 
01/2015 
Reverse/overvoltage 
protection 
Included 
from Prod.Lot > 01/2015 
Copyright BECKMANN+EGLE GmbH, All Rights Reserved.  Page 11  Internet: www.bue.de