Attention! Read this first!
Read through the Instructions manual carefully. The guarantee becomes null and void if damage or injury results from non-compliance with these instructions. We cannot assume any liability for consequential damage or injury.
Manual
EX20xx, EX30xx
Content
Introduction
Dear Customer, Thank you for buying the EX-Panelmeter. Your EX-Panelmeter is a product which was manufactured with state-of-the-art technology.
This product conforms to valid European and national safety guidelines. Conformity has been certified; the relevant documents are in the manufacturer's possession.
To maintain this standard and ensure safe operation, you as user must comply with the Instructions manual.
Our Internet site at www.bue.de will help you answer Frequently Asked Questions and provide tips and updated handbooks.
This symbol indicates important instructions which must be followed. Imprint
These Instructions for Use were published by Beckmann+Egle GmbH, Kernen. All rights reserved. Neither this publication nor any part of it may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the publisher's prior consent in writing.
These Instructions for Use are based on the technology used at the time of printing. Changes in technology and equipment are reserved.
Revision history
Date
Rev
Reason
30.06.05
0
first release
03.05.10
1
Explanation for setting decimal point
09.01.15
2
Added changes for EX32xx (voltage protection)
Introduction ......................................................................................................................................... 2
Safety Information ............................................................................................................................... 3
Warranty ............................................................................................................................................. 3
Description .......................................................................................................................................... 4
Functions ............................................................................................................................................. 4
Initial Operation ................................................................................................................................... 4
Maintenance, proper disposal .............................................................................................................. 4
Specifications ...................................................................................................................................... 4
Dimensions ......................................................................................................................................... 5
EX-Voltage Modules (Voltmeters) ....................................................................................................... 6
EX-Current Modules (Currentmeters) .................................................................................................. 7
Adaption and Adjustment .................................................................................................................... 9
Technical Data .................................................................................................................................. 11
Copyright BECKMANN+EGLE GmbH, All Rights Reserved. Page 2 Internet: www.bue.de
EX20xx, EX30xx
Safety Information
Please observe the following when using the product:
This Panelmeter left our factory in perfect technical condition. To preserve this state
and ensure safe operation, the user must observe the safety instructions and warnings.
Electronic components and accessories do not belong into child hands.
Accident prevention regulations issued by the industrial trade associations and
pertaining to the safe use of electrical appliances and equipment on registered commercial premises must be complied with.
A responsible person, trained in the use of electrical equipment, must be present
when this product is used in schools, further education classes, DIY and self-help groups.
Turn power OFF before making any changes to the hardware-configuration.
Use in adverse environmental conditions is prohibited.
Such adverse conditions may include:
- areas exposed to moisture or high levels of humidity,
- environments containing dust and combustible gases, vapours or solvents
- during lightning or weather likely to induce strong electrical fields.
The user is obliged to ascertain whether the product is suitable for the purpose for
which he intends to use it.
Parts leading high voltage (e.g. inverter for backlight) must be secured against
unintentionally contact.
Electrostatic sensitive devices – observe precautions for handling.
Warranty
The warranty covers the cost-free replacement or repair of faulty parts which can be
proved to have resulted from the use of defective material or errors in production. Parts subject to normal wear and tear are specifically excluded from this guarantee.
We cannot accept any responsibility for any damage or injury resulting from the use
of this product.
The customer accepts all costs for delivery and return of goods, and any charges
which may apply in the event of machine failure or modifications to the device undertaken by us.
Additional claims are excluded.
Copyright BECKMANN+EGLE GmbH, All Rights Reserved. Page 3 Internet: www.bue.de
EX20xx, EX30xx
Description
Digital panel meters EX with and w/o illumination. The modules of the EX series were specially designed for build-in situations of housings and panels. Simple mounting and no need of galvanic separated support-voltage, those meters with high voltage and current precision are the real alternative for analog meters. They are useful in all areas where it is necessary to deliver reliable physical Data to operator. Measure and test engineering, solar technique and electronics, as well as machine- and apparatus engineering are typical area of application.
Functions
The modules of the EX-Series offer following functions:
Measure
digital snap-in instrument oft he EX-series are designed to measure directly electrical and non-electrical physical metrics.
Reading
Digital-Instruments are used to avoid parallax error of analog instruments, to have a far higher resolution and ability to view the values from further distances.
Initial Operation
Please check the wiring before switching ON.
Maintenance, proper disposal
Please consider as well following advices:
For cleaning do not use carbon containing cleaners, nor benzine, alcohol or similar.
Damages caused by disregard of advices from instruction manual lapses warranty
claims.
Specifications
Auxiliary Voltage
The instruments do not need galvanic separated auxiliary voltage (common ground). (does not apply for EX2030 to EX2034!)
Polarity
The instruments display polarity automatically
Decimal point
The position of the decimal point can be adjusted by option..
Exceedance of range
Exeedance of range are displayed by a single 1 or -1 (Overflow display).
Lightning
The modules of the series EX30xx have an built-in green-yellow LED-light(12V).
Mounting
Snap-In mounting for fixing and simple finish for housings and panels.
Housing color
The housing color is black.
Copyright BECKMANN+EGLE GmbH, All Rights Reserved. Page 4 Internet: www.bue.de