Becker R12/17 C SE+ K8, R20/17 C SE+ K8, R40/17 C SE+ K8, R50/17 C SE+ K8, L60/11 C SE+ K8 Assembly And Operating Instructions Manual

...
Page 1
R12/17...L80/11
Version: C SE+ K8
en
Assembly and Operating Instructions
Tubular drives for sun protection with automatic cloth untensioning
Important information for:
• Fitters / • Electricians / • Users
These instructions must be kept safe for future reference.
2010 300 853 0b24/01/2019
Becker-Antriebe GmbH Friedrich-Ebert-Straße 2-4 35764 Sinn/Germany www.becker-antriebe.com
Page 2

Table of contents

General ............................................................................................................................................................................... 3
Warranty ............................................................................................................................................................................. 3
Safety instructions ............................................................................................................................................................... 4
Instructions for the user................................................................................................................................................... 4
Instructions for installation and commissioning.................................................................................................................. 4
Intended use ....................................................................................................................................................................... 6
Assembling and disassembling the plug-in connecting cable................................................................................................... 6
Assembling the plug-in connecting cable .......................................................................................................................... 6
Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58 ................................................................ 7
Installation........................................................................................................................................................................... 8
Assembling the drive ....................................................................................................................................................... 8
Undoing the mounting pin................................................................................................................................................ 8
Drive adapter safety catch ............................................................................................................................................... 8
Assembling the drive adapter with safety catch on the drive shaft................................................................................... 8
Disassembling the drive adapter with safety catch on the drive shaft .............................................................................. 9
Assembling and disassembling the drive adapter with separate drive adapter safety catch............................................... 9
Assembling and disassembling the drive adapter with screw connection ........................................................................ 9
Mounting the drive in the tube .......................................................................................................................................... 9
Adjusting the limit positions with a rotary switch or a locking button ........................................................................................ 11
Deleting the limit positions with a rotary switch or a locking button ......................................................................................... 11
Setting the limit positions using the programming unit........................................................................................................... 12
Deleting the limit positions using the programming unit......................................................................................................... 13
Automatic adjustment of direction of rotation ....................................................................................................................... 14
Activating/deactivating the additional fabric untensioning function with the programming unit.................................................. 14
Information for the electrician ............................................................................................................................................. 15
Disposal ............................................................................................................................................................................ 15
Maintenance ..................................................................................................................................................................... 15
Technical data dia. 45 ........................................................................................................................................................ 15
Technical data dia. 58 ........................................................................................................................................................ 16
What to do if...?.................................................................................................................................................................. 16
Sample wiring diagram ....................................................................................................................................................... 17
Declaration of conformity ................................................................................................................................................... 18
2
Page 3

General

These tubular drives are high-quality products with the following features:
Optimised for articulated-arm awnings, cassette awnings, drop-arm awnings, screens and conservatory shades.
Easy to set and delete the limit positions using the programming unit
Automatic shading solution length adjustment: Changes in the fabric (temperature, ageing, moisture) are accommodated
Tensile load is optimally adapted to the mechanical requirements of the sun protection system
Automatic cloth untensioning protects cloth
Automatic detection of retracted limit position
Simple to set the extended limit position by pressing a button on the programming unit
Left or right hand installation
Several drives can be operated in parallel
Comprehensive range of the drive manufacturer's control units can be used
Compatible with existing drives with electronic limit switching (4-core connecting cable)
For plug-in connecting cable
Automatic detection of limit positions thanks to intelligent electronic system with stop systems
The limit positions do not have to be reset: Changes in the shading solution are accommodated automatically when using stop
systems.
Smooth operation of the system and the drive increases the service life
Please observe these Assembly and Operating Instructions when installing and setting the equipment. The date of manufacture comes from the first four digits of the serial number. The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week. Example: 24th calendar week in 2012
Ser. No.: 1224XXXXX
Explanation of pictograms
CAUTION
ATTENTION
CAUTION indicates a hazardous situation which, if not avoided, could result in injury.
ATTENTION indicates measures that must be taken to avoid damage to property.
Denotes user tips and other useful information.

Warranty

Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries, e.g., crushing of limbs. Therefore, structural modifications may only be carried out with our prior approval and strictly in accordance with our instructions, particularly the information contained in these Assembly and Operating Instructions. Any further processing of the products which does not comply with their intended use is not permitted. The end product manufacturer and fitter have to ensure that all the relevant current statutory, official and, in particular, EMC regu­lations are adhered to during utilisation of our products, especially with regard to end product manufacture, installation and cus­tomer advice.
3
Page 4

Safety instructions

The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury.

Instructions for the user

General information
The drive must be disconnected from its power source during cleaning and maintenance and when re-
placing parts.
All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by trained technicians, in particular qualified electricians.
Children from the age of 8 years and persons with reduced physical, sensory or mental capabilities or
lack of experience and/or knowledge may use these devices, provided they are supervised or have been instructed in the safe use of the device, and have understood the hazards involved. Children must not play with the device.
Systems have to be checked regularly by authorised specialists for wear and damage.
Always put damaged systems out of operation immediately until they are repaired by an authorised
specialist.
Do not operate equipment if people or objects are within the danger zone.
Observe the danger zone of the equipment during operation.
Ensure that there is adequate clearance (at least 40 cm) between moving parts and adjacent objects.
Caution Safety instructions for avoiding serious injuries.
Crushing or shearing points must be avoided or protected.

Instructions for installation and commissioning

General information
Observe the safety instructions in EN 60335-2-97. Please note that this list of safety instructions is not
exhaustive, since it would be impossible for the standard to include all sources of danger. For example, the design of the operated product, the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user’s place of use cannot be taken into consideration by the drive manufacturer. If any questions or uncertainties regarding the safety instructions contained in the standard arise, please contact the manufacturer of the part or end product in question.
All applicable standards and regulations for electrical installation must be complied with.
All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by trained technicians, in particular qualified electricians.
Only use spare parts, tools and accessory devices which have been approved by the drive manufac-
turer. Unapproved third-party products or modifications to the system and its accessories represent a risk to your safety and the safety of others. This means that the use of unapproved third-party products, or modifications which have not been agreed with or approved by us, are prohibited. We do not accept li­ability for damage or injury arising from such actions.
Position switch with OFF presetting within sight of the driven product, but away from moving parts, at a
height of over 1.5 m. This must not be publicly accessible.
Permanently mounted control devices must be positioned where they can be seen.
Rated torque and duty cycle must be suitable for the requirements of the driven product.
Technical data - rated torque and service life can be found on the type plate of the tubular drive.
4
Page 5
Hazardous moving parts of the drive must be installed at a height of over 2.5 m above floor level or any
other surface from which the drive can be accessed.
To ensure safe operation of the system after commissioning, the limit positions must be correctly set/
programmed in.
Drives with a H05VV-F connecting cable may only be used indoors.
Drives with a H05RR-F, S05RN-F or 05RN-F connecting cable may be used both indoors and outdoors.
To connect the drive to the driven part, solely mechanical accessory components made by the drive
manufacturer from the current product catalogue may be used. The components must be installed in accordance with the manufacturer's instructions.
If the drive is used for shading solutions in a specially marked area (e.g., escape routes, hazard zones,
safety areas), compliance with all applicable regulations and standards must be ensured.
Caution Safety instructions for avoiding serious injuries.
When electrical or electronic equipment and units are operated, certain components,
e.g., the power supply unit, are live. Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings.
Be careful when touching the tubular drive, as it heats up during operation for technical
reasons.
Before installation, shut down all lines and control devices that are not essential for op-
eration.
Crushing or shearing points must be avoided or protected.
When installing the drive, all-pole disconnection from the mains with a contact gap of at
least 3mm per pole must be provided (EN60335).
If the mains connecting cable is damaged, it may only be replaced by the manufacturer.
If the drive has a plug-in connecting cable, it must be replaced with the same type of mains connecting cable, which is available from the drive manufacturer.
Attention Safety instructions for avoiding property damage.
Ensure that there is adequate clearance between moving parts and adjacent objects.
The drive must not be carried by the mains connecting cable.
All latching connections and fastening screws on the brackets must be checked to en-
sure that they are secure.
Ensure that nothing rubs against the tubular drive, such as shading solution attach-
ments, screws, etc.
5
Page 6

Intended use

The type of tubular drive in these instructions is intended exclusively for the operation of articulated-arm awnings, cassette awn­ings, drop-arm awnings, screens and conservatory shades. To function properly, this type of tubular drive needs a fixed stop in the retracted limit position (e.g., retracted awning). It may only be used in networked systems if all the individual drives are exactly synchronised and reach the limit positions at the same time. For roller shutter applications, please use only the types of tubular drive designed for this purpose. This type of tubular drive is designed for use in single systems (one drive per barrel). The tubular drive must not be used in potentially explosive areas. The connecting cable is not suitable for transporting the drive. Always carry the drive by the housing tube. Other applications, uses and modifications are not permitted in order to protect the safety of the users and others, since these ac­tions can impair the system’s safety and carry the risk of personal injury and property damage. The drive manufacturer does not accept liability for damages or injury arising from such actions. Always observe the information in these instructions when operating or repairing the system. The drive manufacturer does not ac­cept liability for damage or injury resulting from improper usage.

Assembling and disassembling the plug-in connecting cable

Assembling the plug-in connecting cable

Insert the dead connecting cable into the drive head until the locating lug clicks into place in the drive. If necessary, use a suitable flathead screwdriver to assist with insertion. Set the screwdriver into one of the two plug grooves provided for this purpose. Check that the cable is properly engaged.
1 = locating lug
6
Page 7

Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58

1.
2.
A
Caution Prior to disassembly, the power supply to the connecting cable must be disconnected.
Insert a suitable flathead screwdriver right into the recess of the locating latch, so that the latch releases the locating lug from the plug.
Now you can pull out the connecting cable along with the flathead screwdriver.
dia. 45 and dia. 58
A = locating latch
7
Page 8

Installation

Assembling the drive

Attention To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used.
Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus weight of the shading solution).
Caution Electrical connections may only be carried out by a qualified electrician. Prior to assembly, the power supply must be disconnected and secured. Please give the enclosed connection information to the responsible electrical contractor.
Calculate the space required at the side (M) by measuring the drive head (1) and wall bracket (2). The clear dimension of the box (X) minus the space required at the side (M) and idler (G) gives the length (L) of the barrel: L=X-M-G.
The space required at the side (M) varies depending on the combination of drive and wall bracket.
Then mount the wall bracket and idler. Ensure that the barrel is aligned at right angles to the wall and that sufficient axial play is al­lowed for the mounted system.

Undoing the mounting pin

When pushed in, the mounting pin (2) locks automatically. To undo the mounting pin (2), push the tab washer (1) upwards and pull out the mounting pin (2).

Drive adapter safety catch

Assembling the drive adapter with safety catch on the drive shaft

8
Page 9

Disassembling the drive adapter with safety catch on the drive shaft

2.
1.
Disassembly with disassembly tool, Item no. 4930 300 606 0
Disassembly with long nose pliers

Assembling and disassembling the drive adapter with separate drive adapter safety catch

Assembling and disassembling the drive adapter with screw connection

Mounting the drive in the tube

For profile tubes:
In the case of some drive adapters, tolerances of the groove widths in different bar­rels can be offset by rotating the drive adapter into a different groove recess. These groove recesses have different sizes and allow the drive to fit exactly.
9
Page 10
Y
X
For round shafts:
-10 mm
Measure the lug of the thrust ring (X, Y). Then notch the tube on the motor side, so the lug of the thrust ring can also be pushed into the shaft. There must be no play between the lug of the thrust ring and the shaft.
To ensure secure torque transmission for round shafts, we recommend screwing the drive adapter to the shaft (see the table below).
Attention!When drilling into the barrel, never drill near the tubular drive!
Size of drive
[mm]
dia. 35-dia. 45 All Up to 50 Self-tapping screw
dia. 58 Aluminium drive adapter Up to 120 Countersunk screw
dia. 58 diecast drive adapter Up to 120 Self-tapping screw
We also recommend screwing the idler to the barrel.
Drive adapter Torque
max. [Nm]
Fastening screws
(4 units)
dia. 4.8 x 9.5 mm
M8 x 16 mm
dia. 6.3 x 13 mm
Attention Do not hammer the tubular drive into the tube or drop it into the barrel!
Assemble the tubular drive with the relevant ring (1) and drive adapter (2). If the ring has several grooves, select the groove which is a perfect fit and push the ring (1) onto the thrust ring.
Insert the tubular drive with the pre-assembled ring (1) and drive adapter (2) into the tube to achieve a form fit. Ensure that the ring and drive adapter are secure in the tube.
Mount the assembled unit comprising barrel, tubular drive and idler on the box and secure the drive with a split or spring pin ac­cording to the type of wall bracket fixing.
Lay the connecting cable
Lay the connecting cable up to the tubular drive, and fix The connecting cable and any antennae must not project into the winding chamber. Cover any sharp edges.
10
Page 11

Adjusting the limit positions with a rotary switch or a locking button

1 s
1 s
until STOP and hold until
STOP
1 s until1 s 1 s 1 s 1 s 1 s 1 s
Intelligent installation management
Limit position status indicator
A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
Completion of installation following automatic setting of limit position "Stop"
The drive saves the limit position "Stop" permanently once the it has been reached 3 times in succession. Installation is then com­plete.
If the tubular drive switches off prematurely while extending/retracting, due to an obstruc­tion, the obstruction can be cleared by extending/retracting the screen and removing the obstruction. The upper limit position can be set by extending/retracting again.
Extended point to retracted stop
Open to the desired extended limit position.
Carry out the following sequence without interruption between the individual drive commands.
The tubular drive makes a "click" sound to confirm.
Then retract to the permanent upper stop. During travel, the end position status in­dicator (ESI) must be displayed before the end position is reached.
The tubular drive switches off automatically.
The limit positions are now set.

Deleting the limit positions with a rotary switch or a locking button

The switching commands sequence must be carried out in quick succession. Any addi­tional functions that have been set are retained.
Carry out the following deletion sequence without interruption between the individual drive commands:
The tubular drive confirms. Both limit positions are deleted.
11
Page 12

Setting the limit positions using the programming unit

Programming button Travel button
Retract
Extend
Intelligent installation management
Limit position status indicator
A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
Completion of installation following automatic setting of limit position "Stop"
The drive saves the limit position "Stop" permanently once the it has been reached 3 times in succession. Installation is then com­plete.
These tubular drives are designed for short-time operation (for the operating mode, please see technical data). The number of cycles an awning is capable of depends on the barrel diameter and awning extension. The drive running time is cut short if the drive has not cooled down fully after the previous use.
Extended point to retracted stop
Press the travel button on the programming unit to move the sun protection system to the desired Extend limit position. This must be at least 2 revolutions of the barrel away from the retracted limit position. Next, release the travel button for a moment to cut the power to the tubular drive.
Press the programming button for 3 seconds to save this position. The tubular drive clicks to confirm storage of the maximum projection position. You can now release the programming button; the position is now saved.
Use the travel button to retract the sun protection system, without pausing, until the tubular drive switches itself off.
The drive saves the limit position “Stop” permanently once it has been reached 3 times in succession. Installation is then complete. As a final check, run the sun pro­tection system to the two limit positions again.
To ensure that the limit position is reliably detected and the sun protection system is fully closed, the tubular drive pulls the cloth slightly more strongly during the installa­tion.
On subsequent runs, the tubular drive automatically carries out a short reversal to un­tension the cloth in the retracted limit position.
12
Page 13

Deleting the limit positions using the programming unit

black
brown
blue
green-yellow
black
brown
blue
green-yellow
Programming button Travel button
Connect the wires of the tubular drive to those of the same colour in the programming unit and switch on the power supply. Please pause for 1 sec after the last drive command before beginning the deletion se­quence. Also leave a pause of 1 sec between the individual steps of the deletion sequence.
Deleting a limit position when 2 limit positions are programmed
Any additional functions that have been set are retained.
Open/close to the limit position to be deleted.
Press the programming button and keep it pressed.
Then press down the travel button and keep it pressed.
Now release the programming button, but continue to keep the travel button pressed.
Next press the programming button again.
The tubular drive confirms.
The limit position is now deleted.
13
Page 14
Deleting both limit positions
Any additional functions that may have been set are deleted at the same time, or are reset to the factory default settings.
Open/close the shading solution to a point between the limit positions.
Press the programming button and keep it pressed.
Then press down the travel button and keep it pressed.
Now release the programming button, but continue to keep the travel button pressed.
Next press the programming button again.
The tubular drive confirms.
Both limit positions are deleted.

Automatic adjustment of direction of rotation

After the limit positions have been set, the drive automatically adjusts the direction of rotation, so that the drive always moves UP when the black wire is energised.
Activating/deactivating the additional fabric untensioning function with the
programming unit
The "to retracted stop" limit position must be set for the fabric untensioning function.
On delivery, the fabric untensioning function is activated. To deactivate it, move to the Retract limit position. Press the program­ming button for approx. 5seconds. The drive moves a short distance out of the limit position and back again. The fabric untension­ing function is now deactivated. Repeat the procedure to activate it.
14
Page 15

Information for the electrician

Tubular drives with electronic limit switching can be connected in parallel. The maximum switching contact load of the switching equipment (timer, relay control, switch, etc.) must be observed. To operate drives with electronic limit switching, only use switch­ing elements (timers) that are not earthed via the drive. The outputs of the switching element must be potential-free in the neutral position. Use external conductor L1 to control the up and down direction. Other devices or consumers (lamps, relays, etc.) must not be dir­ectly connected to the drive connecting cables. For this purpose, the drives and additional devices must be decoupled by relay controls. When installing the drive, all-pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided.
Attention Only use mechanically or electrically locked switching elements with a marked zero posi­tion! This also applies when drives with electronic and mechanical limit switching are used in the same system. The changeover time for switching the running direction must be at least 0.5 s. The switch and control must not execute simultaneous UP and DOWN com­mands. Protect the electrical connections from damp. Once you have finished wiring everything to the control, ALWAYS check the right direction assignment of the drive to the control buttons UP and DOWN, EXTEND and RETRACT. If the drive is to be operated with devices which contain sources of interference, the elec­trician must ensure suitable interference suppression for the relevant devices.

Disposal

This product is made of various materials which must be disposed of properly. Find out about the applicable regulations on recyc­ling or disposal for this product in your country. The packaging material must be disposed of properly.

Maintenance

These drives are maintenance-free.

Technical data dia. 45

Type R12/17
C SE+ K8
Rated torque [Nm] 12 20 30 40 50
Output speed [rpm] 17 11
Limit switch range 64revolutions
Supply voltage 230VAC/50Hz
Connected load [W] 110 160 205 260 240
Rated current consumption [A] 0.50 0.75 0.90 1.15 1.10
Operating mode S24min
R20/17
C SE+ K8
R30/17
C SE+ K8
R40/17
C SE+ K8
R50/11
C SE+ K8
Degree of protection IP44
Min. tube inside diameter [mm] 47
Emission sound pressure level [dB(A)]
≤70
15
Page 16

Technical data dia. 58

Type L60/11
C SE+ K8
Rated torque [Nm] 60 80
Output speed [rpm] 11
Limit switch range 64revolutions
Supply voltage 230VAC/50Hz
Connected load [W] 265 310
Rated current consumption [A] 1.20 1.40
Operating mode S24min
Degree of protection IP44
Min. tube inside diameter [mm] 60
Emission sound pressure level [dB(A)]
≤70
L80/11
C SE+ K8

What to do if...?

Problem Remedy
Tubular drive overruns the limit position or does not reach the set limit position.
Repair electrical installation and re-program limit positions.
Check electrical installation; remove external devices; reset limit positions.
Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
The tubular drive will not retract after setting the extended limit position.
Tubular drive stops arbitrarily; cannot be restarted in the same direction.
Tubular drive does not run in the right direction. Tubular drive is overheated. The tubular drive is operational
Tubular drive only runs for approx. 1 second. Tubular drive is faulty. Replace the tubular drive.
When you attempt to set the limit positions using the program­ming unit, this does not work.
Delete the limit positions, reprogram the outer limit position, and retract immediately.
Use a more powerful tubular drive.
Ensure that the sun protection system runs smoothly.
Delete limit positions, then re-program limit positions.
again after a few minutes.
Tubular drive is faulty (does not work even after standing still for a long period of time). Replace the tubular drive.
Check the electrical connection.
Programming unit faulty. Replace programming unit.
Check the electrical connection.
16
Page 17

Sample wiring diagram

Contr
ols
black
brown
blue
green/yellow
Contr
ols
The assignment of the black and brown wires according to the direction of travel is de­pendant on how the drive is installed (mounted to the right or to the left).
Controlling one/several drive(s) via a single switch/button
17
Page 18

Declaration of conformity

18
Page 19
19
Page 20
Loading...