Becker R12/17 C SE+ K8, R20/17 C SE+ K8, R40/17 C SE+ K8, R50/17 C SE+ K8, L60/11 C SE+ K8 Assembly And Operating Instructions Manual

...
R12/17...L80/11
Version: C SE+ K8
en
Assembly and Operating Instructions
Tubular drives for sun protection with automatic cloth untensioning
Important information for:
• Fitters / • Electricians / • Users
These instructions must be kept safe for future reference.
2010 300 853 0b24/01/2019
Becker-Antriebe GmbH Friedrich-Ebert-Straße 2-4 35764 Sinn/Germany www.becker-antriebe.com

Table of contents

General ............................................................................................................................................................................... 3
Warranty ............................................................................................................................................................................. 3
Safety instructions ............................................................................................................................................................... 4
Instructions for the user................................................................................................................................................... 4
Instructions for installation and commissioning.................................................................................................................. 4
Intended use ....................................................................................................................................................................... 6
Assembling and disassembling the plug-in connecting cable................................................................................................... 6
Assembling the plug-in connecting cable .......................................................................................................................... 6
Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58 ................................................................ 7
Installation........................................................................................................................................................................... 8
Assembling the drive ....................................................................................................................................................... 8
Undoing the mounting pin................................................................................................................................................ 8
Drive adapter safety catch ............................................................................................................................................... 8
Assembling the drive adapter with safety catch on the drive shaft................................................................................... 8
Disassembling the drive adapter with safety catch on the drive shaft .............................................................................. 9
Assembling and disassembling the drive adapter with separate drive adapter safety catch............................................... 9
Assembling and disassembling the drive adapter with screw connection ........................................................................ 9
Mounting the drive in the tube .......................................................................................................................................... 9
Adjusting the limit positions with a rotary switch or a locking button ........................................................................................ 11
Deleting the limit positions with a rotary switch or a locking button ......................................................................................... 11
Setting the limit positions using the programming unit........................................................................................................... 12
Deleting the limit positions using the programming unit......................................................................................................... 13
Automatic adjustment of direction of rotation ....................................................................................................................... 14
Activating/deactivating the additional fabric untensioning function with the programming unit.................................................. 14
Information for the electrician ............................................................................................................................................. 15
Disposal ............................................................................................................................................................................ 15
Maintenance ..................................................................................................................................................................... 15
Technical data dia. 45 ........................................................................................................................................................ 15
Technical data dia. 58 ........................................................................................................................................................ 16
What to do if...?.................................................................................................................................................................. 16
Sample wiring diagram ....................................................................................................................................................... 17
Declaration of conformity ................................................................................................................................................... 18
2

General

These tubular drives are high-quality products with the following features:
Optimised for articulated-arm awnings, cassette awnings, drop-arm awnings, screens and conservatory shades.
Easy to set and delete the limit positions using the programming unit
Automatic shading solution length adjustment: Changes in the fabric (temperature, ageing, moisture) are accommodated
Tensile load is optimally adapted to the mechanical requirements of the sun protection system
Automatic cloth untensioning protects cloth
Automatic detection of retracted limit position
Simple to set the extended limit position by pressing a button on the programming unit
Left or right hand installation
Several drives can be operated in parallel
Comprehensive range of the drive manufacturer's control units can be used
Compatible with existing drives with electronic limit switching (4-core connecting cable)
For plug-in connecting cable
Automatic detection of limit positions thanks to intelligent electronic system with stop systems
The limit positions do not have to be reset: Changes in the shading solution are accommodated automatically when using stop
systems.
Smooth operation of the system and the drive increases the service life
Please observe these Assembly and Operating Instructions when installing and setting the equipment. The date of manufacture comes from the first four digits of the serial number. The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week. Example: 24th calendar week in 2012
Ser. No.: 1224XXXXX
Explanation of pictograms
CAUTION
ATTENTION
CAUTION indicates a hazardous situation which, if not avoided, could result in injury.
ATTENTION indicates measures that must be taken to avoid damage to property.
Denotes user tips and other useful information.

Warranty

Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries, e.g., crushing of limbs. Therefore, structural modifications may only be carried out with our prior approval and strictly in accordance with our instructions, particularly the information contained in these Assembly and Operating Instructions. Any further processing of the products which does not comply with their intended use is not permitted. The end product manufacturer and fitter have to ensure that all the relevant current statutory, official and, in particular, EMC regu­lations are adhered to during utilisation of our products, especially with regard to end product manufacture, installation and cus­tomer advice.
3

Safety instructions

The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury.

Instructions for the user

General information
The drive must be disconnected from its power source during cleaning and maintenance and when re-
placing parts.
All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by trained technicians, in particular qualified electricians.
Children from the age of 8 years and persons with reduced physical, sensory or mental capabilities or
lack of experience and/or knowledge may use these devices, provided they are supervised or have been instructed in the safe use of the device, and have understood the hazards involved. Children must not play with the device.
Systems have to be checked regularly by authorised specialists for wear and damage.
Always put damaged systems out of operation immediately until they are repaired by an authorised
specialist.
Do not operate equipment if people or objects are within the danger zone.
Observe the danger zone of the equipment during operation.
Ensure that there is adequate clearance (at least 40 cm) between moving parts and adjacent objects.
Caution Safety instructions for avoiding serious injuries.
Crushing or shearing points must be avoided or protected.

Instructions for installation and commissioning

General information
Observe the safety instructions in EN 60335-2-97. Please note that this list of safety instructions is not
exhaustive, since it would be impossible for the standard to include all sources of danger. For example, the design of the operated product, the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user’s place of use cannot be taken into consideration by the drive manufacturer. If any questions or uncertainties regarding the safety instructions contained in the standard arise, please contact the manufacturer of the part or end product in question.
All applicable standards and regulations for electrical installation must be complied with.
All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by trained technicians, in particular qualified electricians.
Only use spare parts, tools and accessory devices which have been approved by the drive manufac-
turer. Unapproved third-party products or modifications to the system and its accessories represent a risk to your safety and the safety of others. This means that the use of unapproved third-party products, or modifications which have not been agreed with or approved by us, are prohibited. We do not accept li­ability for damage or injury arising from such actions.
Position switch with OFF presetting within sight of the driven product, but away from moving parts, at a
height of over 1.5 m. This must not be publicly accessible.
Permanently mounted control devices must be positioned where they can be seen.
Rated torque and duty cycle must be suitable for the requirements of the driven product.
Technical data - rated torque and service life can be found on the type plate of the tubular drive.
4
Hazardous moving parts of the drive must be installed at a height of over 2.5 m above floor level or any
other surface from which the drive can be accessed.
To ensure safe operation of the system after commissioning, the limit positions must be correctly set/
programmed in.
Drives with a H05VV-F connecting cable may only be used indoors.
Drives with a H05RR-F, S05RN-F or 05RN-F connecting cable may be used both indoors and outdoors.
To connect the drive to the driven part, solely mechanical accessory components made by the drive
manufacturer from the current product catalogue may be used. The components must be installed in accordance with the manufacturer's instructions.
If the drive is used for shading solutions in a specially marked area (e.g., escape routes, hazard zones,
safety areas), compliance with all applicable regulations and standards must be ensured.
Caution Safety instructions for avoiding serious injuries.
When electrical or electronic equipment and units are operated, certain components,
e.g., the power supply unit, are live. Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings.
Be careful when touching the tubular drive, as it heats up during operation for technical
reasons.
Before installation, shut down all lines and control devices that are not essential for op-
eration.
Crushing or shearing points must be avoided or protected.
When installing the drive, all-pole disconnection from the mains with a contact gap of at
least 3mm per pole must be provided (EN60335).
If the mains connecting cable is damaged, it may only be replaced by the manufacturer.
If the drive has a plug-in connecting cable, it must be replaced with the same type of mains connecting cable, which is available from the drive manufacturer.
Attention Safety instructions for avoiding property damage.
Ensure that there is adequate clearance between moving parts and adjacent objects.
The drive must not be carried by the mains connecting cable.
All latching connections and fastening screws on the brackets must be checked to en-
sure that they are secure.
Ensure that nothing rubs against the tubular drive, such as shading solution attach-
ments, screws, etc.
5

Intended use

The type of tubular drive in these instructions is intended exclusively for the operation of articulated-arm awnings, cassette awn­ings, drop-arm awnings, screens and conservatory shades. To function properly, this type of tubular drive needs a fixed stop in the retracted limit position (e.g., retracted awning). It may only be used in networked systems if all the individual drives are exactly synchronised and reach the limit positions at the same time. For roller shutter applications, please use only the types of tubular drive designed for this purpose. This type of tubular drive is designed for use in single systems (one drive per barrel). The tubular drive must not be used in potentially explosive areas. The connecting cable is not suitable for transporting the drive. Always carry the drive by the housing tube. Other applications, uses and modifications are not permitted in order to protect the safety of the users and others, since these ac­tions can impair the system’s safety and carry the risk of personal injury and property damage. The drive manufacturer does not accept liability for damages or injury arising from such actions. Always observe the information in these instructions when operating or repairing the system. The drive manufacturer does not ac­cept liability for damage or injury resulting from improper usage.

Assembling and disassembling the plug-in connecting cable

Assembling the plug-in connecting cable

Insert the dead connecting cable into the drive head until the locating lug clicks into place in the drive. If necessary, use a suitable flathead screwdriver to assist with insertion. Set the screwdriver into one of the two plug grooves provided for this purpose. Check that the cable is properly engaged.
1 = locating lug
6
Loading...
+ 14 hidden pages