Beam Electrolux Mundo User Manual

Page 1
Mundo Series
Owner’s Manual
Page 2
CONTENTS
Introduction 2
Safeguards 3
Power Unit installation 4
Operation & cleaning 5
Maintenance 6
Service warranty 8
INTRODUCTION
Congratulations on your purchase of a new Beam®
Central Vacuum System. It is the built-in cleaning
appliance designed to help you clean your home
e
ciently and e ectively. Unlike conventional
vacuums that can recirculate dust, a Beam®
system lifts dirt, dust mites, pollen, dander and
other allergens from
and other surfaces, and carries them away from
living areas to help improve indoor air quality.
It has been clinically proven to relieve allergy
symptoms.
To obtain the maximum bene
System, please read this manual carefully prior
to use. Then enjoy cleaner, healthier living and
years of trouble-free performance.
For more information on Beam®
Central Vacuum Systems and
other innovative
Beam® products, visit
www.beamvac.com.
oors, curtains, furniture
t from your Beam®
Components of Beam® Central Vacuum System
Power Unit/Dust Collection Receptacle:
Mounted in the utility room, basement or garage, it
removes dust, dirt and allergens from living areas.
Tubi ng : Dust and dirt
from “inlet valves” to the power unit/receptacle.
Inlet valves: Installed in the wall, each inlet valve
connects the power brush and
hose to the tubing in your home.
Cleaning tools: Flexible hose and tools make
whole-house cleaning easy.
are carried through tubing
exible cleaning
1. Central Vacuum Pipe Installation
2. Wall Inlet
3. Power Unit Utility Valve
4. VacPan
5. Filtered Separator
6. External Exhaust
2
Page 3
GENERAL INFORMATION
The built-in vacuum system is designed for dry pick up of household dirt and dust. Avoid vacuuming up
hard or sharp objects to prevent hose and plastic pipe clogs or damage.
IMPORTANT SAFEGUARDS SAFEGUARDS
When using an electric appliance, basic precautions should always be followed, including the following:
WARNING: Read All Instructions Before Using This Vacuum Cleaner.
To reduce the risk of re, electric shock or injury:
t Do not use outdoors or on wet surfaces. t Do not block the motor hood ventilation openings
and duct on the top of the power unit. Lack of
ventilation air
t Do not locate the power unit in a high temperature
area or where it is inaccessible, for example, an attic
or crawl space.
t Mount the built-in vacuum system power unit no less
than 30cm from the ceiling or any adjacent wall and
at least 70cm from the
exhausted outside, make sure the adjacent wall is at
least 30cm from the exhaust port. DO NOT exhaust
into a concealed area.
t Do not leave vacuum cleaner when plugged in.
Remove hose from inlet valve and unplug from outlet
when not in use and before servicing.
This appliance is not intended for use by persons
t
(including children) with reduced physical, sensory, or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
t Do not allow to be used as a toy. Close attention is
necessary when used by or near children.
t Use extra care when cleaning on stairs. t Use only as described in this manual. Use only
manufacturer
.
ow will cause the motor to overheat.
oor. If the unit is not
’s recommended attachments.
t Some hoses contain electrical wires. Do not use if
damaged, cut or punctured. Avoid picking up sharp
objects.
t Do not use with damaged cord or plug. If vacuum
cleaner is not working as it should, has been
dropped, damaged, left outdoors or dropped into
water, return it
to a service center.
t Connect to a properly grounded (earthed) outlet only
(see grounding/earthing instructions).
t Do not use extension cords or outlets with
inadequate current carrying capacity.
t Turn o all controls before unplugging. t Do not unplug by pulling on cord. To unplug, grasp
the plug, not the cord.
Do not handle plug or vacuum cleaner with wet hands.
t t Do not put any object into openings. Do not use with
any opening blocked; keep free of dust, lint, hair and
anything that may reduce air
ow.
t Keep hair, loose clothing, ngers and all parts of
body away from openings and moving parts.
t Do not pick up anything that is burning or smoking,
such as cigarettes, matches, or hot ashes.
t Do not operate vacuum without dust bag or lter in
place.
t Do not pick up ammable or combustible liquids such
as gasoline, or use in areas where they may be
present.
service or the
SAVE THESE INSTRUCTIONS
Waste of Electrical and Electronic Equipment (WEEE) The symbol on the product or on its packaging indicates that
this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the
recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential
negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste
handling of this product. For more detailed information about recycling of this product, please contact your local waste disposal
shop where you purchased the product.
3
Page 4
GROUNDING (EARTHING) INSTRUCTIONS
This appliance must be grounded (earthed) and is equipped with a cord having an equipment­grounding (earthing) conductor and grounding (earthing) plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded (earthed) in accordance with all local codes and ordinances.
DANGER
Improper connection of an equipment-grounding (earthing) conductor can result in risk of electric­shock. Do not m appliance. If it will no outlet installed by a quali appliance is for use in a regular electrical circuit, corresponding to the electrical standard in your country.
odify the plug provided with the
the outlet, have proper
ed technician. This
PLANNING
If your home already has a system of plastic tubing and inlet valves, you are ready to install the power unit (refer to Power Unit Installation section). If not, you may have the system installed by a professional or you may choose to do it yourself. If you install the system yourself, it is important to ca inlet valve, the power unit, and the network of plastic tubing. This booklet deals only with the installation of the power unit; “How-To” booklets generally are included with installation kits.
refully plan the location of each
Power Unit Location
The power unit is connected to inlet valves via a system of lightweight plastic tubing installed in the walls of your home.
The power unit should be located as far from the general living area as possible, yet accessible so you can remove the dirt receptacle, reach the
lter, and inspect the unit. Typical locations are utility room, basement or garage. It is recommended that the exhaust be vented outside; never into a wall, a ceiling, or a concealed space in the house.
Power Unit Wiring
The power unit must be mounted within 1.8m of a
grounded (earthed) electrical outlet. Be sure your
house agrees with the voltage on the Rating Plate and do not overload the circuit.
Power Unit Installation
The power unit hangs on a mounting bracket which is screwed to the wall. The bottom screws of the mounting bracket should be about 1.2m up from the receptacle (or at least 70cm from the proper motor cooling, mount the power unit at least 30cm from the ceiling and any adjacent wall.
oor for convenient removal of the dust
oor). For
4
Page 5
motor be overloaded causing the circuit to open. If this occurs and the power unit fails to operate, depress the reset button which is located on the side of the power unit. If the protector continues to trip; contact the authorized service center nearest you.
Electrical Fault Protection for BM262, BM265, and BM285
The central vacuum system employs features that monitor the following operation levels: AC voltage, currenty draw voltage, current draw and board temperature. If the voltage is below or above standard operating voltage, high current or locked rotar, the power unit will not
Mounting the Power Unit
When you have chosen a mounting location, you can install the mounting bracket using the enclosed screws. Drill the holes and tighten the screws to hang the power unit. Please make sure to consider the wall type when attaching the mounting bracket. Align the power unit
wall. Securely tape each joint using duct or electrical tape. DO NOT USE GLUE. Attach the exhaust pipe to the motor exhaust if exhausting outdoors. Connect the two low voltage wires located on the backside of the power unit to the wires installed with the main trunk line. It is recom­mended you secure the connection with wire nuts. Be certain to comply with local electrical codes and regula­tions. Plug the unit into a regular electrical outlet. You are now ready to check the installation of the unit:
t Be sure the lter is properly installed in the power unit. t
Be sure the dirt receptacle is properly secured to the
power unit t Plug the hose into each inlet valve to be sure the electrical contacts operate properly.
t Check each inlet valve for air leaks. t Check each pipe connection for air leaks.
OPERATION
Your central vacuum system starts and stops automatically. To turn the system on, plug the
remove the hose from the valve.
The hose handle may be equipped with an
start and stop of the power unit while the hose is plugged into an inlet valve. This allows you to control the system without unplugging the hose.
Overload-protection reset button for BM165 and BM185
Certain central vacuum system models feature an overload protection (circuit breaker) which can be reset should the
blink or go out until the problem ceases. If the circuit board reaches an elevated temperature, the power unit will not operate any one of these problems happening, make sure all low­volt switches are in the o position, then press the on/o button, unplug hose, or wait for temperature to lower. If
problem persists, contact your authorized dealer or distirbutor.
BM265, and BM285
In the unlikely event that something causes the power unit to turn on, or if the power unit is unintentionally left on, your central vacuum has been developed with a motor
damage to the motor.
To restart, remove the hose from the wall inlet and reinsert - the power unit should come back on.
Inlet valves
Plugging the hose into an inlet valve completes a low-voltage (24-volt) electrical circuit which activates a
unit, unplug the hose from the inlet. When unplugging the hose, hold the inlet cover open for a few seconds to allow suction to decrease and protect the inner seal.
An obstruction in the inlet valve may cause the power unit to continue to run after the hose has been removed from the inlet. To shut down the power unit, check all the inlet valves and remove obstructions.
Hose use and care
The hose should be used and stored at temperatures
°C. When not in use, hang the hose on the hanger
above 5
supplied. If the hose becomes clogged, turn on the power unit using the manual switch and seal the extra air-space by holding the hose rmly and blocking the end. This
the obstruction. If the hose remains
clogged, insert an electrician’s sh tape (wire) or dry
hose to remove the obstruction,
being careful not to puncture the hose. Disconnect hose handle from wands before storing.
5
Page 6
Cleaning Tools
Dirt Receptacle and Filter
The Beam® hose and attachment set comes with a telescopic wand and a variety of cleaning tools allowing you to clean virtually any surface from
wand or directly on the hose handle.
The combo tool is used for
cleaning and is used about 80% of the time. It allows you to move from carpets to
stopping by switching the convenient toe switch on top of the tool.
The round dusting brush makes dusting quick and easy. It can be used for
furniture, counters, wall decorations, window areas, lamp shades or wherever dusting is needed.
The upholstery nozzle with slip-on brush is convenient when cleaning
walls, furniture, curtains or mattresses. It can be used with or without the slip-on brush.
The crevice tool is ideal for tight spaces and corners,
such as in the kitchen and beneath/around cabinets. It is designed for narrow spaces, crevices, along edges or other hard-to­clean areas.
The snap-on, three-tool caddy
allows you to carry your most-
used tools directly on the
wand.
The hose hanger is used to
easily coil and store the hose
in a closet.
the dirt
pass
through the unit and no cleaning can take place.
Emptying the Dirt Receptacle
BM185 and BM285
To empty the dirt receptacle grasp the latches on the side of releasing the receptacle. Remove and empty the contents.
upward. To avoid suction leakage make sure the recep­tacle is securely attached.
Filter maintenance
BM165, BM262 and BM265
-cleaning.
However, if cleaning is desired, just follow these steps:
NOTE: Disconnect power cord from electrical outlet
1. Remove the dirt receptacle.
2. Wrap a large plastic bag around the lower portion
through the plastic bag. Shake vigorously. Dirt will fall into the bag.
4. Carefully remove the bag from the unit. Then empty the dirt receptacle into the bag.
5. Replace the dirt receptacle on the power unit.
Cleaning Instruction Caution:
.
place.
Dust Collection: BM165, BM262, and BM265
Your Mundo Power Unit comes equipped with a convenient paper bag, which can be simply discarded when full. A full paper bag will deprive the power unit of proper suction and minimizes the performance of the machine. Depending on how much you use your central vacuum system it is recom­mended that you empty the paper bag 2-3 times per year. Replacement bags can be purchased through your autho­rized central vacuum distributor/dealer.
NOTE: Never use the BM165 or BM265 without a paper bag in place.
MAINTENANCE
Instructions provided in the booklet serve as a
suction can be maintained by keeping the dirt
hose free from clogs.
6
How to Change the Paper Bag
1. Unplug the power unit from all electrical sources.
2. Remove the canopy.
3. Remove the paper bag from the intake valve.
4. Place and press the new bag into place. Turn the bag’s opening to lock it into place.
5. Place the canopy back on the power unit.
Page 7
TROUBLE-SHOOTING
If you experience trouble with your central vacuum system, follow the suggestions below before calling for service.
Partial/total loss of suction power
t Be sure lid is on properly. t Empty dirt receptacle. t Clean cartridge t Be sure each inlet valve is properly closed. t Check for hose obstruction.
Plug hose into any inlet valve. Then, as you check each of the other inlet valves, raise the inlet cover and hold your hand over the opening to check for suction. If there is normal suction at each inlet, then insert the hose into one of the other inlets. If there is no suction through the hose at the second inlet, the blockage is in the hose. To clear the hose obstruction, insert a blunt instru hose (garden hose, wood dowel). If there is one inlet valve without normal suction and you have checked for hose blockage, then the blockage is in the pipe system between the blocked inlet valve and the power unit (see instructions below).
DO NOT OIL THE MOTOR AT ANY TIME. IT IS
PERMANENTLY LUBRICATED AND SEALED.
lter.
ment into the
Power unit will not start
t Check for blown fuse in main house electric supply box.
If your power unit has a control light, the solid green light
t
will indicate when when the unit has proper voltage and the low-voltage circuit is supplying power to the inlets.
t If the green light is ashing, or does not light up, and the
motor does not start, the power unit could have experienced a fault due to excessively high or low standard operating voltage, high current draw, or a locked rotor. It is also possible that the unit was powered on with a low-volt connection (ie. handle, vac pan, etc.) in the ON position. To resolve this issue:
a. Ensure all handles and vac pans are in the OFF
position
b. Unplug the power unit cord from the wall outlet,
and then plug in again.
c. Press the on/o button on the power unit.
t
Should the light be on, but the motor starts only with the on/o button and not at the inlets, the problem is broken low-voltage wiring to the wall inlets. Call your authorized BEAM dealer/distributor.
Power unit will not stop
t Check inside each inlet valve for obstruction of low-
voltage contacts. If no visual obstruction can be detected, disconnect the cleaner from the power receptacle and contact your nearest service station/dealer.
Clear blockage in pipes
Insert the hose into the inlet valve where there is no
suction; hold your hand over the hos end. Release hand quickly. Repeat several times. If blackage does not clear, contact your nearest dealer/distributor.
BM 165
BM 185
Power Unit Shuts Off by Itself
Remove and then re-insert the hose into inlet or toggle switch off/on. See “Motor Protection Shutoff” portion of the user manual.
BM 262
BM 265
BM 285
7
Page 8
SERVICE INFORMATION
The instructions in this booklet serve as a guide to
routine maintenance. For addi tional information,
contact your nearest Authorized Beam dealer or
distributor.
Service warranty
Warranty is managed by your local dealer/distributor.
1 07 52 3 2 000001
Weeks sequential
Rating plate
XXXXXXXXX XXXXXXXXXXX
MODEL SERIAL NUMBER
XXX VOLTS XX Hz XXXX WATTS
10,000 units max
Module Number
Assembly Line
Week
Yea r
Place holder
The model, type and serial numbers are indicated on
the rating plate located on the control panel or motor
hood. For prompt and complete service information,
always refer to these numbers
when inquiring
about service.
Sold and serviced by:
©2007 Electrolux Home Care Products Ltd.
www.beam.com
# 460511
8
Loading...