1 Description & Specifi cations
BEA’s Infrared (IR) Spotfi nder is a
hand-held tool used to locate an
active infrared source.
This easily locates an IR area
which can be used to assist in the
palcement of the sensing zone as
well as approximate the distance
from a sensor.
The Spotfi nder has two settings,
(1) LED only (light, no sound) or
(2) LED and Buzzer.
This accessory will shut-off after
45 seconds of no IR activity. To
reactivate, switch OFF then back
ON by selecting either LED or
BUZZER.
DESCRIPTION SPECIFICATION
POWER SUPPLY AAA Alkaline Batteries (2) Included
DIMENSIONS 3” X 2 1/4” X 1” (76mm x 57mm x 25mm)
MATERIAL ABS Plastic
SPOTFINDER
USER’S GUIDE
INFRARED ZONE LOCATOR
2 Settings & Placement
For sliding door overhead presence detection, place the Spotfi nder fl at on the fl oor so that the IR-SPOT is at the appropriate
distance from the door face. Adjust the IR Curtain on the sensor until the LED turns Orange and/or the Buzzer begins to beep
(as in Position 2 below).
NOTE: The Spotfi nder only serves to identify an area of infrared light and not necessarily imply the area of the sensors detection.
BEA, Inc. always recommends a walk test to ensure compliance to all applicable standards for sensing patterns.
‘GREEN’ LED FOR POSITION
See ANSI
A156.10 for
Required
‘ORANGE’ LED FOR POSITION
LED COLOR: POSITION
‘RED’ LED FOR POSITION
POSITION LED COLOR BUZZER LEVEL IR LIGHT LEVEL
1 GREEN NONE NONE
2 ORANGE SOFT - WEAK LOW
3 RED LOUD - STRONG HIGH
N/A FLASHING ORANGE LOW BATTERIES
Distance
75.0176.04 20080331 Page 1 of 2
3 Precautions
Shut off all power going to work area before attempting any wiring procedures.
Maintain a clean & safe environment when working in public areas.
Constantly be aware of pedestrian traffi c around the area.
Always stop pedestrian traffi c through the doorway when performing tests that may result in unexpected reactions by the door.
Always check placement of components before powering up so that moving parts will not catch any wires or cause damage to
equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10 / 19) upon completion of installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA,
Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
4 Tips
Avoid long exposure to bright
sunlight and/or moisture.
Keep the IR-SPOT and LED lenses clean. Before long storage, remove batteries
5 Battery Replacement
1.5 - VOLT AAA BATTERIES (LR03)
1. Remove two screws from back of Spotfi nder.
2. Separate housing and install a two fresh 1.5-Volt (AAA Type LR03) batteries making sure to
observe proper polarity.
3. Reassemble housing and replace screws.
NOTE: Don’t throw used batteries away with the general trash. Discard per your local
municipal laws and regulations.
6 Company Contact
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting
a problem, please call BEA, Inc. If you must wait for the following workday to call BEA, leave the door
inoperable until satisfactory repairs can be made. Never sacrifi ce the safe operation of the automatic door or
gate for an incomplete solution. The following numbers can be called 24 hours a day, 7 days a week.
For more information, visit www.beasensors.com
to prevent battery acid damage.
US and Canada:
Canada:
Northeast:
Page 2 of 2 75.0176.04 20080331
1-866-249-7937
1-866-836-1863
1-866-836-1863
Southeast:
Midwest:
West:
1-800-407-4545
1-888-308-8843
1-888-419-2564