BEA LZR-s600 User Manual

75.5792.05 LZR-S600 20180814 Page 1 of 12
LZR®-s600
75.5792.05 LZR-S600 20180814 Page 1 of 12
LASER SCANNER FOR BUILDING AUTOMATION & SECURITY
with max. detection range of 82 ft x 82 ft
User’s Guide
Page 2 of 12 75.5792.05 LZR-S600 20180814Page 2 of 12 75.5792.05 LZR-S600 20180814
SAFETY
The device contains IR and visible laser diodes.
IR laser: wavelength 905nm; max. output pulse power 75W
(Class 1 according to IEC 60825-1)
Visible laser: wavelength 650nm; max. output CW power 3mW
(Class 3R according to IEC 60825-1)
The visible laser beams are inactive during normal operation. The installer can activate the visible lasers if needed.
READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP
CAUTION!
Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous radiation exposure.
INSTALLATION AND MAINTENANCE
Do not look into the laser emitter or the visible red laser beams.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Only trained and qualified personnel are recommended to install and set up the sensor.
Test the proper operation of the installation before leaving the premises.
Avoid moving objects and light sources in the detection field.
Avoid condensation.Avoid the presence of smoke and fog in the detection field.
Avoid exposure to sudden and extreme temperature changes.
Avoid extreme vibrations.
Keep the sensor
permanently powered in
environments where the
temperature can descend
below 32 °F.
Wipe the front screens regularly with a clean and damp cloth.
Do not use aggressive products to clean the front screens.
Avoid direct exposure to high pressure cleaning.
Do not cover the front screens.
75.5792.05 LZR-S600 20180814 Page 3 of 12
1
7
8
9
10
2 3 4
5
6
1 2 3 4
75.5792.05 LZR-S600 20180814 Page 3 of 12
DESCRIPTION
READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP
1. laser sweep emission
2. laser sweep reception
3. LED signals (4)
4. screws for position lock (2)
5. connector
6. protection cover
7. visible laser beams (3)
8. notches for tilt angle adjustment (2)
9. adjustable bracket
10. cable conduits (4)
SYMBOLS
Caution!
Laser radiation
Remote control
sequence
Factory values
Possible
remote control
adjustments
Alarm
LED SIGNAL
Tip Quick
installation
DETECTION LEDs
no detection
(green)
ERROR LED POWER LED
detection
(red)
no error
(off)
error
(orange)
no power
(on)
power
(blue)
1. Detection LED: relay 1 – opening field
2. Detection LED: relay 2 – safety field
3. Error LED
4. Power LED
All 4 LEDs can be switched off and on again by remote control. This can be useful in cases where the sensor should not draw any attention.
LED flashes quickly
LED flashes
LED is off
LED flashes slowly
Page 4 of 12 75.5792.05 LZR-S600 20180814
x
4
21
3
x
30’
Page 4 of 12 75.5792.05 LZR-S600 20180814
READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP
HOW TO USE THE REMOTE CONTROL
After unlocking, the red LED flashes and the sensor can be adjusted by remote control.
If the red LED flashes quickly after unlocking, you need to enter an access code from 1 to 4 digits.
To end an adjustment session, always lock the sensor.
red red red off
redredred
off
ADJUSTING ONE OR MORE PARAMETERS
CHECKING A VALUE
RESTORING TO FACTORY VALUES
The access code is recommended for sensors installed close to each other.
SAVING AN ACCESS CODE
Enter the existing code
DELETING AN ACCESS CODE
30 minutes after last use, the sensor locks access to the remote control session. To regain access, cycle the power. The remote control session will then be accessible for another 30 minutes.
X = NUMBER OF FLASHES = VALUE OF THE PARAMETER
= field width: 4.2 m
green
orange
off
= field width is defined by Learn
red red
green orange green
redred green
Learn
red red
off
red red red
off
75.5792.05 LZR-S600 20180814 Page 5 of 1275.5792.05 LZR-S600 20180814 Page 5 of 12
POSSIBLE APPLICATIONS
PROTECTION OF WORKS OF ART: WARNING & ALARM
Field 1 (4 active curtains) triggers relay 1:
WARNING
Field 2 (only curtain C1 active) triggers relay 2:
ALARM
Adapt the field widths (ex: 20 ft):
Reduce field 2 to one curtain (C1):
20 ft 20 ft
DAY AND NIGHT FEATURE
During night time, field 2 is active as well and triggers relay 2 (intrusion alarm).
Adapt the field width of field 1 (ex: 20 ft):
During day time, only field 1 is active and triggers relay 1.
Adapt the field width of field 2 (ex: 25 ft):
20 ft
25 ft
Page 6 of 12 75.5792.05 LZR-S600 20180814
1
2
a db
e f g h
c
Page 6 of 12 75.5792.05 LZR-S600 20180814
MOUNTING
Use the mounting template to position the sensor correctly.
The gray area indicates the detection range.
Pass the cable ±4 inches through the cable opening.
If drilling an opening is not possible, use the cable conduits on the back side of the bracket.
Drill 4 holes as indicated on the mounting template.
Drill a hole (1/2 inch min.) for the cable if possible.
Position the bracket and secure using the 4 screws to avoid vibrations.
WIRING
Rotate the sensor until the two triangles are face to face.
Position the housing on the bracket.
Close and secure the protection cover.
NOTE: FACTORY WARRANTY VOIDED IF PROTECTION COVER IS NOT USED!
Open the protection cover, plug the connector, and position the cable in the slit.
Use the visual aid below to ensure correct wiring to the door control.
CONNECTOR
(side view)
BLACK
CONNECTOR
RED
BLUE WHITE
BLUE/WHITE GREEN
ORANGE WHITE/BLACK
ORANGE/BLACK GREEN/WHITE
WIRE COLORS FUNCTION
Power supply (12 – 35 VDC)
Red (+)
Black (-)
White Green
White/Black
Green/White
Blue (+)
Blue/White (-)
Orange
Orange/Black
Relay 1: Opening Field
Relay 2: Safety Field
Test
Learn
No test function:
connect blue and blue/white wires to power supply (no polarity)
No Learn via input:
connect orange and orange/black wires to ground/ common
To launch a Learn, apply power for the length of time in which the Learn is to be performed (minimum of 1 millisecond).
75.5792.05 LZR-S600 20180814 Page 7 of 12
3
4
C1
C3
C4
C2
a
b c
75.5792.05 LZR-S600 20180814 Page 7 of 12
POSITIONING
Adjust the lateral position of the detection field.
Adjust the tilt angle of the detection field with the 3 mm hex key.
Lock the position of the mounting bracket to avoid malfunctioning in case of extreme vibrations.
Unlock the sensor and activate the visible laser beams.
The visible laser beams indicate the approximate postion of curtain C1 and the angle of the detection field.
The visible laser beams will remain active for 15 minutes or can be turned off the same way they were activated.
MOUNTING SIDE
Select the corresponding mounting side.
The sensor learns its environment and automatically determines the detection field(s). Both red LEDs flash slowly and the 3 visible laser beams automatically light up for 30 seconds.
WITH BACKGROUND WITHOUT BACKGROUND
The sensor memorizes the floor as reference point and signals a fault when its orientation is changed (observe orange flashing LED).
No reference point is memorized. No alarm in case of interference.
Stay outside of the detection field to avoid disturbances.
left right left right center
Page 8 of 12 75.5792.05 LZR-S600 20180814
5
-
-
-
-
Page 8 of 12 75.5792.05 LZR-S600 20180814
FIELD DIMENSIONS
FIELD 1
FIELD 2
394 in
394 in
WIDTH
WIDTH
field 2 = field 1
HEIGHT
HEIGHT
no field
20 in – 984 in
20 in – 984 in
394 in
394 in
no field20 in – 984 in
4 in – 984 in
EXAMPLES
for a field width of 62 in
for a field height of 45 in
IMPORTANT: Test the proper operation of the installation before leaving the premises.
LEARN
The Learn can be launched either via remote control or by connecting the orange and orange/black wires.
Launch a Learn under the following conditions:
• after changing the sensor position
• when new objects are added to or changed in the detection zone
During Learn, the sensor learns its surroundings and adapts the detection zone shape. Objects in the detection field will be cut out.
To launch a Learn via remote control, use the following sequence:
Stay outside of the detection field to avoid disturbances.
3 s
red red red green
max. 30 s
Wait for the sensor to learn its environment
or lock it by remote control.
75.5792.05 LZR-S600 20180814 Page 9 of 12
6
4
4
2
2
off
8
6
10
8
A – NO P – NC P – NC A – NO
P – NC A – NO P – NC A – NO
in
in
ms
X
X
X
X
off 500100 600200 700300 800400 900
R1
R2
R1
R2
75.5792.05 LZR-S600 20180814 Page 9 of 12
REMOTE CONTROL ADJUSTMENTS (OPTIONAL)
deactivate curtain on both fields
activate curtain only on field 2
activate curtain on both fields
activate curtain only on field 1
ACTIVE DETECTION CURTAINS
CURTA IN C1 C2 C3 C4
The distances between the curtains depend on the mounting height and location. When mounted on the left, the distance between curtain C1 and curtain C4 is approximately 0.3 ft for every foot (mounting height).
Example: At 10 feet, the distance between C1 and C4 is 1.5 feet.
Ex:
C1 + C2 are active on safety field C3 + C4 are active on optional field
C1 is active on both fields C2+C3 are active on safety field C4 is inactive
All curtains are active on both fields
C1 C2 C3 C4
OUTPUT CONFIGURATION
R1 R2
R = relay output
IMMUNITY FILTER
MIN. OBJECT SIZE
(approximate values)
OUTPUT ACTIVATION DELAY
The outputs are triggered after a
constant detection time of x ms.
(ex: value 3 = 300 ms)
(approximate values)
DETECTION FIELD REDIRECTION
R = relay output
UNCOVERED ZONE
indoor indoor
outdoor
low
outdoor
low
outdoor
med
outdoor
med
outdoor
high
outdoor
high
FOR CRITICAL ENVIRONMENTS (e.g. RAIN, SNOW, FOG)
FOR CRITICAL OBJECTS (e.g. BL ACK CARS)
field 1
field 1 or
field 2
field 2 field 2
A = active P = passive
NO = normally open NC = normally closed
Page 10 of 12 75.5792.05 LZR-S600 20180814Page 10 of 12 75.5792.05 LZR-S600 20180814
TROUBLESHOOTING
No blue LED No power Check cable and connection.
Polarity of power supply is inverted
Check the polarity of the power supply.
All LEDs have been deactivated by remote control
Activate LEDs using remote control.
Only blue LED is on Test input is not connected Check wiring. The blue and blue/white
cable must be connected to the test input or the power supply.
Detection LED remains green
Detection field too small or deactivated
Check size of fields.
Launch a Learn.
Object size is too small Decrease minimum onject size.
Detection LED remains red Someone/Something is in the
detection field
Step out of the field and/or remove the any object(s) from the field.
Field is touching floor/wall/door – this leads to detection
Activate the 3 red beams and check if the position of the sensor is correct. If not, adjust the hex screws.
Verify the field size.
Launch a Learn.
Orange LED flashing and detection LEDs are red
No background (reference point) is found
Check position of sensor.
Check the mounting side setting. If no reference point is found, set the mounting side to value 3 to 5.
Launch a new Learn.
Sensor is masked Verify and clean the front screens with a
damp cloth.
Orange LED is on
Both detection LEDs are orange
Power supply voltage exceeds acceptable limits
Check power supply voltage.
Sensor exceeds temperature limits
Verify the temperature of the environment. Protect the sensor from sunlight using a cover, if necessary.
Internal error Wait a few seconds.
If the LED remains ON, reset the power supply. If the LED turns on again, replace the sensor.
Sensor does not respond to the remote control
30 minutes after last use, sensor locks access to RC
Cut and restore power supply. RC is accessible again for 30 minutes.
Remote control batteries not installed properly or are dead
Check battery orientation or replace the batteries.
Remote control not pointed correctly
Point the remote control towards the sensor, but with a slight angle. The RC should not be pointed in a right angle in front of the sensor.
Reflective object is close to the sensor
Avoid highly reflective material in proximity to the sensor.
Sensor does not unlock Access code needs entered or
an incorrect code was used
Cut and restore power supply. No code is required to unlock during the first minute after powering.
75.5792.05 LZR-S600 20180814 Page 11 of 1275.5792.05 LZR-S600 20180814 Page 11 of 12
TECHNICAL SPECIFICATIONS
Technology: laser scanner, time-of-flight measurement
Detection mode: motion and presence
Detection range: Default: 33 ft x 33 ft @ 2% remission factor (max. 82 ft x 82 ft)
Angular resolution: 0.3516°
Min. detected object size (typ.): 0.8 in @ 10 in
1.4 in @ 16 in
2.8 in @ 33 ft
6.9 in @ 82 ft
Emission characteristics
IR laser: Red visible laser:
wavelength 905 nm; max. output pulse power 75 W (CLASS 1) wavelength 650 nm; max. output CW power 3 mW (CLASS 3R)
Supply voltage: 10 – 35 VDC @ sensor side
Power consumption: < 5 W
Peak current @ power-on: 1.8 A (max. 80 ms @ 35 V)
Cable length: 30 ft
Response time: typ. 20 ms (max. 80 ms)
+ output activation delay
Output:
Max. switching voltage: Max. switching current: Switching time: Output resistance: Voltage drop on output: Leakage current:
2 electronic relays (galvanic-isolated – polarity-free)
35 VDC / 24 VAC 80 mA (resistive) tON=5 ms; t
OFF
=5 ms typ 30 Ω < 0.7 V @ 20 mA < 10 µA
Input:
Max. contact voltage: Voltage threshold:
2 optocouplers (galvanic-isolated – polarity-free) 30 VDC (over-voltage protected) Log. H: >8 VDC Log. L: <3 VDC
Response time monitoring input: < 5 ms
LED signal: 1 blue LED: power-on status
1 orange LED: error status 2 bi-colored LEDs: detection/output status (green = no detection, red = detection)
Dimensions (D x W x H): 5.0 in x 3.6 in x 2.75 in (mounting bracket + 0.55 in)
Material: PC/ASA
Color: Black
Mounting angles on bracket:
-45°, 0°, 45°
Rotation angles on bracket:
-5 – 5°
Tilt angles on bracket:
-3 – 3°
Protection degree: NEMA 4 / IP65
Temperature range:
-22 – 140 °F if powered -14 – 140 °F if unpowered
Humidity: 0 – 95% non-condensing
Vibrations: < 2G
Pollution on front screen: max. 30%, homogenous
Norm conformity:
2006/95/EC: LVD 2002/95/EC: RoHS
2004/108/EC: EMC EN 60529:2001
IEC 60825-1:2007 EN 60950-1:2005
EN 61000-6-2:2005 EN 61000-6-3:2006
Specifications are subject to change without prior notice. All values measured in specific conditions.
Page 12 of 12 75.5792.05 LZR-S600 20180814
PLEASE KEEP FOR FURTHER USE – DESIGNED FOR COLOR PRINTING
75.5792.05 LZR-S600 20180814
Page 12 of 12 75.5792.05 LZR-S600 20180814
BEA hereby declares that the LZR®-s600 is in conformity with the basic requirements and the other relevant provisions of the directives 2006/95/EC, 2002/95/EC, 2004/108/EC, and 2006/42/EC. Notified Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, 45141 D-Essen EC-type examination certificate number: 44 205 11 392410-002 Angleur, May 2011, Jean-Pierre Valkenberg, Authorized representative and responsible for technical documentation The complete declaration of conformity is available on our website: www.bea-industrial.be For EC countries: according to the directive 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)
Support technique: 1-800-407-4545 | Service clients: 1-800-523-2462
Questions techniques générales: Tech_Services@beainc.com | Les documents techniques: www.BEAinc.com
BEA, le fabricant du détecteur, ne peut pas être tenue responsable pour des installations incorrectes ou des ajustements inappropriés du détecteur/de l’appareil; par conséquent, BEA ne garantit aucun usage du capteur en dehors de son but prévu.
BEA recommande fortement que les techniciens d’installation et de services soient certifi és AAADM pour les portes piétonnières, certifi és IDA pour les
portes/portails, et formés en usine pour le type de système de portes/portails. Les installateurs et le personnel de service sont responsables d’exécuter une évaluation des risques à la suite de chaque installation/entretien, en s’assurant
que l’installation du système de détecteurs est conforme avec les règlements, codes et normes locaux, nationaux et internationaux. Une fois que l’installation ou l’entretien est terminé, une inspection de sécurité de la porte/du portail doit être effectuée selon les recommandations du
fabricant ou les directives AAADM/ANSI/DASMA (le cas échéant) pour les meilleures pratiques de l’industrie. Les inspections de sécurité doivent être effectuées pendant chaque appel de service — vous pouvez trouver des exemples de ces inspections de sécurité sur l’étiquette d’information de sécurité (p. ex., ANSI/DASMA 102, ANSI/DASMA 107).
Vérifi er que toute la signalisation appropriée de l’industrie et les étiquettes d’avertissement sont en place.
ATTENTES DE CONFORMITÉ DE L’INSTALLATION/L’ENTRETIEN DE BEA