6 Safety Rules
6 Hazard Symbols and Meanings
9 Ground Fault Circuit Interrupter Protection
11 Important Safety Instructions
Glossary
13 Glossary
Generator Components
14 12000ER Component Chart
15 Spare Parts List
17 Sockets
Features
18 Features
Operation
19 Unit Grounding
Starting the Generator
19 Filling Oil
20 Oil Specification Chart
20 Filling Fuel
21 Turn On The Fuel Valve Lever
21 Close The Choke Valve
21 Start The Generator
22 Start The Generator Recoil Start
22 Open The Choke Valve
23 Connect To Load
Stopping the Generator
23 Disconnect Load
23 Turn Off The Engine Switch
24 Close The Fuel Valve Lever
Storage
24 Drain The Fuel
24 Protective Treatment
Transporting
25 Transporting
Accessories
26 Accessory Installation
26 Two-Wheel Short Axle
Maintenance
27 Maintenance Chart
28 Replace Engine Oil
28 Clean Air Cleaner
29 Clean The Fuel Valve Lever Sediment Cup
Attention: Read through the complete
manual prior to the initial use of your
generator.
Using the Operator’s manual
The operating manual is an important part of your generator. It should
be read thoroughly before initial use, and referred to often to make sure
adequate safety and service concerns are being addressed.
Reading the owner’s manual thoroughly will help avoid any personal
injury or damage to your machine. By knowing how best to operate this
machine you will be better positioned to show others who may also
operate the unit.
This manual was written to take you from the safety requirements to the
operating functions of your machine. You can refer back to the manual at
any time to help troubleshoot any specific operating functions, so store it
with the machine at all times.
Record Identification Numbers
Generator
If you need to contact an Authorized Dealer or Customer Service line
(1-866-850-6662) for information on servicing, always provide the
product model and identification numbers.
You will need to locate the model and serial number for the machine and
record the information in the places provided below.
Date of Purchase:
Dealer Name:
Dealer Phone:
Product Identification Numbers
Model Number:
Serial Number:
4
5
SAFETYSAFETY
Save these Instructions
SAFETY RULES
This is the safety alert symbol. It is used
to alert you to potential personal injury
hazards. Obey all safety messages that
follow this symbol to avoid possible
injury or death.
The safety alert symbol ( ) is used with a signal word (DANGER,
CAUTION, WARNING), a pictorial and/or a safety message to alert you
to hazards.
DANGER indicates a hazard which, if not avoided, will result in death
or serious injury.
WARNING indicates a hazard which, if not avoided, could result in
death or serious injury.
CAUTION indicates a hazard which, if not avoided, might result in
minor or moderate injury.
NOTICE indicates a situation that could result in equipment damage.
Follow safety messages to avoid or reduce the risk of injury or death.
HAZARD SYMBOLS AND MEANINGS
EXPLOSION
FIRE
BURNING
ELECTRIC
SHOCK
WARNING
Generator exhaust contains carbon monoxide, a
poisonous gas that can kill you.
You CANNOT smell or see this gas.
• Use the generator outdoors, away from open windows, vents, or
doors that could allow the carbon monoxide gas to come indoors.
Keep the generator at least 1 meter (3 feet) away from any structure
or building during use.
• NEVER use a generator indoors, including in homes, garages,
basements, crawl spaces, and other enclosed or partially-enclosed
areas, even with ventilation. Opening doors and windows or using
fans will not prevent carbon monoxide build-up in the home.
• NEVER use a generator in enclosed or partially-enclosed spaces.
Generators can produce high levels of carbon monoxide very quickly.
When you use a portable generator, remember that you cannot smell
or see carbon monoxide. Even if you can’t smell exhaust fumes, you
may still be exposed to carbon monoxide.
• NEVER operate the generator in an explosive atmosphere, near
combustible materials or where ventilation is not sufficient to carry
away exhaust fumes. Exhaust fumes can cause serious injury or death.
• If you start to feel sick, dizzy, or weak while using a generator, get
to fresh air RIGHT AWAY. DO NOT DELAY. The carbon monoxide
from generators can rapidly lead to full incapacitation and death.
• If you experience serious symptoms, get medical attention
immediately. Inform medical staff that carbon monoxide poisoning
is suspected. If you experienced symptoms while indoors, have
someone call the fire department to determine when it is safe to
re-enter the building.
TOXIC
FUMES
6
KICKBACKREAD
MANUAL
7
SAFETYSAFETY
WARNING
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or death.
When Adding or Draining Fuel
• Observe all safety regulations for the safe handling of fuel. Handle
fuel in safety containers. If the container does not have a spout, use
a funnel.
• Do not overfill the fuel tank, leave room for the fuel to expand.
• Do not refill fuel tank while the engine is running. Before refueling the
generator, turn it off and let it cool down. Gasoline spilled on hot
engine parts could ignite.
• Fill the tank only on an area of bare ground. While fueling the tank,
keep heat, sparks and open flame away. Carefully clean up any spilled
fuel before starting engine.
• Always fill fuel tank in an area with plenty of ventilation to avoid
inhaling dangerous fumes.
• NEVER store fuel for your generator in the home. Gasoline, propane,
kerosene, and other flammable liquids should be stored outside of
living areas in properly-labeled, non-glass safety containers. Do not
store them near a fuel-burning appliance, such as a natural gas water
heater in a garage. If the fuel is spilled or the container is not sealed
properly, invisible vapors from the fuel can travel along the ground and
can be ignited by the appliance’s pilot light or by arcing from electric
switches in the appliance.
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
These generators are equipped with a GFCI (Ground Fault Circuit
Interrupters) 120V duplex receptacles for protection against the hazards
of electrical shock from defective attachments such as, tools, cords,
and cables.
WARNING
The GFCI may not function unless the generator is properly
grounded. Follow the correct procedure specified in the section
labeled GROUNDING INSTRUCTIONS.
A GFCI is a device that interrupts electricity from either the utility or
generator by means of a special type of circuit breaker that determines if
a current flow to the ground occurs.
A GFCI can be used only with generators that have the neutral wire
internally bonded to the frame, and the frame properly grounded to the
earth. A GFCI will not work on generators that do not have the neutral
wire bonded to the frame, or on generators which have not been properly
grounded. All BE generators have internally bonded ground wires.
THERE IS A PERMANENT CONDUCTOR BETWEEN THE
GENERATOR (STATOR WINDING) AND THE FRAME.
!
This product can expose you to chemicals
including lead, which is known to the State
of California to cause cancer and birth
defects or other reproductive harm. For more
information, go to www.P65Warnings.ca.gov.
Wash hands after handling.
8
9
SAFETYSAFETY
This product has been designed with internal grounding or floating
bonded neutral. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of
electric shock.
DANGER
Improper grounding can result in a risk of electrocution. Check with a qualified electrician for your local
requirements if you are in doubt as to whether the unit
is properly grounded.
This generator is equipped with a grounding terminal for added
protection. Using the ground path from the generator to an
external ground source as instructed in the section labeled “Grounding
Instructions” in the Preparation section of this manual can be
necessary. Please consult a qualified electrician for local regulations.
The generator is a potential source of electrical shock if not kept dry.
Keep the generator dry and do not use in rain or wet conditions. To
protect from moisture, operate it on a dry surface under an open,
canopy-like structure. Dry your hands if wet before touching the
generator.
Plug appliances directly into the generator. Or, use a heavy duty,
outdoor-rated extension cord that is rated (in watts or amps) at least
equal to the sum of the connected appliance loads. Check that the
entire cord is free of cuts or tears and that the plug has all three
prongs,especially a grounding pin.
NEVER try to power the house wiring by plugging the generator into
a wall outlet, a practice known as “back feeding”. This is an extremely
dangerous practice that presents an electrocution risk to utility workers
and neighbors served by the same utility transformer. It also bypasses
some of the built-in household circuit protection devices.
IMPORTANT SAFETY INSTRUCTIONS
WARNING
To reduce the risk of injury, read this operator’s manual
completely before using.
When using this product, the following basic
precautions should always be followed.
• Do not enclose the generator or cover it. The generator may become
overheated if it is enclosed. If generator has been covered to protect if
from the weather during non use, be sure to remove it and keep it well
away from the area during generator use.
• Operate the generator on a level surface. It is not necessary to prepare
a special foundation for the generator. However, the generator will
vibrate on an irregular surface, so choose a level place.
If the generator is tilted or moved during operation, fuel may spill and/or
the generator may tip over, causing a hazardous situation.
Proper lubrication cannot be expected if the generator is operated on a
steep incline or slope. In such a case, piston seizure may occur even if
the oil is above the upper level.
• Pay attention to the wiring or extension cords from the generator to the
connected device. If the wire is under the generator or in contact with
vibrating part, it may break and possibly cause a fire, generator burnout,
or electric shock hazard. Replace damaged or worn cords immediately.
• Do not operate in rain, in wet or damp conditions, or with wet hands.
The operator may suffer severe electric shock if the generator is wet due
to rain or snow. If wet, wipe and dry it well before starting. Do not pour
water directly over the generator, nor wash it with water.
• Be extremely careful that all necessary electrical grounding procedures
are followed during each and every use. Failure to do so can be fatal.
If you must connect the generator to the house wiring to power
appliances, have a qualified electrician install the appropriate
equipment in accordance with local electrical codes.
10
• DO NOT smoke while charging a battery. The battery emits flammable
hydrogen gas, which can explode if exposed to electric arcing or open
flame. Keep the area well ventilated and keep open flames / sparks away
when charging a battery.
• The engine becomes extremely hot during and for some time after
operation. Keep combustible materials well away from generator area.
Be very careful not to touch any parts of the hot engine especially the
muffler area or serious burns may result.