Please note that the manual shown here are for reference purposes only. It does not constitute a legal contract or a commitment between BDCOM and any person or entity.Although every effort has been made to ensure all the information in this manual is correct,inaccuracies or typographical errors may still occur. In no event shall BDCOM be responsible or liable, directly or indirectly, for any damage or loss caused or alleged to be caused by or in connection with the manual. BDCOM reserves the right to alter, update and otherwise change the information contained in the manual from time to time without notice.
Overview
S1510-8P-150/S1518-16P-330/S1526-24P-400 are Ethernet switch. The PoE ports can automatically detect and supply power with those IEEE 802.3af/at compliant Powered Devices (PD). The power is transmitted along with data in one single cable allowing you to expand your network where there are no power lines or outlets, where you wish to fix devices such as AP, IP Cameras or IP Phones, etc.
The PoE Switch have VLAN function that improve the network environment and reduces network maintenance
costs.
Port Feature
Model
10/100/1000Mbps RJ45 Port
Gigabit SFP Port
PoE Port
PoE Standard
S1510-8P-150
10
Port1~8
IEEE802.3af/at
S1518-16P-330
16
2
Port1~16
S1526-24P-400
24
2
Port1~24
Product Appearance
Front panel
The Front Panel of the S1510-8P-150 Consists of 10-Port 10/100/1000M Auto-Negotiation Ethernet RJ45 Ports. The LED indicators also on located on the panel.
The Front Panel of the S1518-16P-330 Consists of 16-Port 10/100/1000M Auto-Negotiation Ethernet RJ45 Ports, 2-Port Gigabit SFP slot. The LED indicators also on located on the panel.
10/100M 1000M
Default
VLAN CCTV
Port status indicator
DIP
switch
16*10/100/1000Mbps
PoE Port
2*1000Mbps SFP slots
10/100M 1000M
Default
VLAN CCTV
DIP switch
Port
status indicator
8*10/100/1000Mbps
PoE Port
2*10/100/1000Mbps RJ45
Introduction
The Front Panel of the S1526-24P-400 Consists of 24-Port 10/100/1000M Auto-Negotiation Ethernet RJ45 Ports, 2-Port Gigabit SFP slot. The LED indicators also on located on the panel.
LED Indicator
LED
Color description
PWR Green
Off: No Power supply. Light: Indicates the switch has power.
LNK/ACT
Orange Green
Off: No device is connected to the corresponding port.
LightOrange): Indicates the link through that port is
successfully established at 10/100Mbps.
LightGreen): Indicates the link through that port is
successfully established at 1000Mbps.
Blink: Indicates that the Switch is actively sending or
receiving data over that port.
PoE
Orange
Off: No PoE powered device (PD) connected.
Light: There is a PoE PD connected to be port, which
supply power successfully.
Blink: Indicates port abnormal power supply.
DIP Switch
The DIP switch located on the left panel. Standard: the factory default mode, all ports can communicate with each other. VLAN: PoE port can be isolated each other but poe port can connect to uplink port after open
VLAN to stop broadcast storm to increase forwarding rate of frame.
Extend: Up to 250m PoE distance allows you to expand you network via Ethernet cable to where
there is no power line or outlet but where you want to fix device such as IP Cameras.
Rear Front
1
Fan
2
Power Socket
3
Grounding Terminal
2 Grounding Terminal
3 Power Socket
10/100M 1000M
Default
VLAN CCTV
Port status indicator DIP
switch
24*10/100/1000Mbps
PoE Port
2*1000Mbps SFP slots
Power socket
Connect the female connector of the power cord here, and the male connector to the AC (Alternating Current) power outlet. Please make sure the voltage of the power supply meets the requirement of the input voltage
Grounding
The switch already comes with lightning protection mechanism. You can also ground the switch
through the PE (Protecting Earth) cable of AC cord or with Ground Cable.
Caution Please use the provided power cord.
Make sure the power socket has a good contact with the ground.
Package Contents
PoE Switch. ......................................................................... 1
AC Power Cord. .......................................................... 1
User Guide. .................................................................. 1
Accessories(Rack angle iron*2, Rack installation bolt*8, plastic cushion*4)
Safety Precautions
To avoid any device damage and bodily injury caused by improper use, please observe the following rules.
Keep the power off during the installation.
Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is well grounded.
Use only the power cord provided with the switch.
Make sure that the supply voltage matches the specifications indicated on the rear panel of the switch.
Ensure the vent hole is well ventilated and unblocked.
Do not open or remove the cover of the switch.
Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never use any other liquid
cleaning method.
Desktop Installation
Install the Switch on a desktop, please attach these cushioning rubber feet provided on the bottom at each corner of the Switch in case of the external vibration. Allow adequate space for ventilation between the device and the objects around it.
Caution: If any part is lost and damaged, please contact your local agent immediately.
Installation
Rack Installation
To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below:
1. Check the grounding and stability of the rack.
2. Secure the supplied rack-mounting brackets to each side of the device with supplied screws, as illustrated in the
following figure.
3. After the brackets are attached to the device, use suitable screws (not provided) to secure the brackets to the rack,
as illustrated in the following figure
Turn on the switch
Plug in the negative connector of the provided power cord into the power socket of the device, and the positive connector into a power outlet . After the device is powered on, it begins the Power-On Self-Test. The PWR LED indicator will light on all the time.
Appendix
Specification
Model
S1510-8P-150
S1518-16P-330
S1526-24P-400
Standard
IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3z, IEEE802.3x, IEEE802.3af, IEEE802.3at
Port
10*10/100/1000Mbps
Auto-Negotiation RJ45 Port
16*10/100/1000Mbps
Auto-Negotiation RJ45 Port
24*10/100/1000Mbps
Auto-Negotiation RJ45 Port
2-Port Gigabit SFP Port
PoE Port
Port1~8
Port1~16
Port1~24
PoE Power Output
32W Max
PoE Power on RJ-45
Mode A 1/2(+) 3/6(-)
VLAN and CCTV
Support
PoE Power Budget
140W
300W
380W
Forwarding Mode
Storage-and-Forward
Switching Capacity
20G
36G
52G
Forwarding Rate
14.88Mpps
26.78Mpps
38.69Mpps
Input Power Supply
AC 100-240V 50/60Hz
Operation Temperature
0 ~40
Storage Temperature
-40 ~70
Operation Humidity
10%~90%RH non-condensing
Storage Humidity
5%~90%RH non-condensing
Fan
Fan
DimensionsL*W*H)
280*179*45mm
440*232*45mm
Network Media(cable)
10BASE-T: UTP category 3, 5 cable ( 100m)
100BASE-TX: UTP category 5,5e cable ( 100m) 1000BASE-T: UTP category 5e,6 cable(
100m)
1000Base-X: MMF,SMF
Disclaimer
Please note that the manual shown here are for reference purposes only. It does not constitute a legal contract or a commitment between BDCOM and any person or entity. Although every effort has been made to ensure all the information in this manual is correct,inaccuracies or typographical errors may still occur. In no event shall BDCOM be responsible or liable, directly or indirectly, for any damage or loss caused or alleged to be caused by or in connection with the manual.
BDCOM reserves the right to alter, update and otherwise change the information
contained in the manual from time to time without notice.
Overview
S1210-8P-150/S1218-16P-330/S1226-24P-330 are standard PoE switches. The PoE Switch provide intelligent PoE functions along with 8 10/100Mbps RJ45 ports and 1 Gigabit TP+ 1 Gigabit SFP port. 16/24 10/100Mbps RJ45 ports and 2/2 Gigabit TP/SFP combo interfaces supporting high-speed transminssion of surveillance images and
videos. The PoE ports can automatically detect and supply power to IEEE802.3af/at compliant Powered Devices (PD). The electrical power and data transmission on the same cable can expand your network to the places where no power lines or outlets, where you can in stall devices such as APs, IP cameras, or IP phones etc.
The S1210-8P-150/S1218-16P-330/S1226-24P-330 have VLAN function that
improve the network environment and reduces network maintenance costs.
• Port Feature
Model 10/100Mbps RJ45 Port Gigabit TP/SFP Combo Port PoE Port PoE Standard
S1210-8P-150
8
Port1~8
IEEE802.3af/at
S1218-16P-330
16
2
Port1~16
S1226-24P-330 24 2 Port1~24
Product Appearance
Front panel
The Front Panel of the S1210-8P-150 Consists of 8-Port 10/100M Auto-Negotiation
Ethernet RJ45 Ports, 1 Gigabit TP +1 Gigabit SFP Port. The LED indicators also on located on the panel.
Introduction
The Front Panel of the S1218-16P-330 Consists of 16-Port 10/100M Auto-Negotiation
Ethernet RJ45 Ports, 2-Port Gigabit TP/SFP Combo Port. The LED indicators are also on located on the panel.
The Front Panel of the S1226-24P-330 Consists of 24-Port 10/100M Auto-Negotiation
Ethernet RJ45 Ports, 2-Port Gigabit TP/SFP Combo Port. The LED indicators also on located on the panel.
• Port-based VLAN
S1210-8P-150/S1218-16P-330/S1226-24P-330 have one feature called Port-based VLAN. Where switching the DIP to the “on” position,PoE ports can not communicate with each other ,PoE ports only communcate with the uplink ports.
(Note: Please turn off the device before setting)
Port status indicator
24*10/100Mbps PoE RJ45PoE priorityPort 1 > 2 >3 >...>24
2*10/100/1000Mbps RJ45 & 2*1000Mbps share SFP slots
Port status indicator
2*10/100/1000Mbps RJ45 & 2*1000Mbps share SFP slots
PoE priority
Port status indicator
1*10/100/1000Mbps RJ45 & 1*1000Mbps share SFP slots
• LED Indicator
LED Color Description
PWR
Green
Off: No Power supply. Light: Indi cates the switc h has power.
LNK/ACT
Green
Off: No device is connected to the corresponding port.
Light: Indi cates the link through tha t p or t is successfully
established at 10/100/1000Mbps.
Blink: Indicates that the Switch is actively sending or
receiving data over that port.
Speed
Green
Off: Indicates the link through established at 10Mbps. Light: Indi cates the link through established at 1000Mbps. Blink: Indicates the link through established at 100Mbps.
PoE
Orange
Off: No PoE powered device (PD) connected.
Light: There is a PoE PD connected to be port, which supply power successfully.
Blink: Indicates port abnormal power supply.
Rear panel
100~240V AC
50/60Hz
1
Fan
2
Grounding Terminal
3
Power Soc ket
S1210-8P-150
100~240V AC 50/60Hz
2
Grounding Terminal
3
Power Socket
S1218-16P-330/S1226-24P-330
Power socket
Connect the female connector of the power cord here, and the male connector to the AC (Alternating Current) power outlet. Please make sure the voltage of the power supply meets the requirement of the input voltage.
• Grounding Terminal
The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable.
Caution Please use the original power cord, ensure electrical socket
and device properly grounded.
Package Contents
PoE Switch....................................................................1 PCS
AC Power Cord...............................................................1 PCS
User Guide....................................................................1 PCS
• Accessories(Rack angle iron*2, Rack installation bolt*8, plastic cushion*4)
Safety Precautions
To avoid any device damage and bodily injury caused by improper use, please observe
the following rules.
• Keep the power off during the installation.
• Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good
skin contact and is well grounded.
• Use only the power cord provided with the switch.
• Make sure that the supply voltage matches the specications indicated on the rear
panel of the switch.
• Ensure the vent hole is well ventilated and unblocked.
• Do not open or remove the cover of the switch.
• Before cleaning the device, cut off the power supply. Do not clean it by the waterish
cloth, and never use any other liquid cleaning method.
Desktop Installation
Install the Switch on a desktop, please attach these cushioning rubber feet provided on the bottom at each corner of the Switch in case of the external vibration. Allow adequate space for ventilation between the device and the objects around it.
Caution If any part is missing and damaged, please contact your local agent
immediately.
Installation
Rack Installation
To install the device in an EIA standard-sized, 19-inch rack, follow the instructions
described below:
1. Check the grounding and stability of the rack.
2. Secure the supplied rack-mounting brackets to each side of the device with
supplied screws, as illustrated in the following figure.
3. After the brackets are attached to the device, use suitable screws (not provided) to
secure the brackets to the rack, as illustrated in the following gure.
Turn on the switch
Plug in the negative connector of the provided power cord into the power socket of
the device, and the positive connector into a power outlet . After the device is powered on, it begins the Power-On Self-Test. The PWR LED indicator will light on all the time.
Appendix: Specification
Model S1210-8P-150 S1218-16P-330 S1226-24P-330
Standard
EEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3z, IEEE802.3x, IEEE802.3af, IEEE802.3at
Port
8*10/100Mbps A u t o - N e g o t i a t i o n RJ45 Port
16*10/100Mbps A u t o - N e g o tia t i o n RJ45 Port
24*10/100Mbps A u t o - N e g o tia t i o n RJ45 Port
1G TP And 1G SFP Port 2G TP/SFP Combo Port
PoE Port
Port1~8
Port1~16
Port1~24
PoE Power Output
32W Max
PoE Power on RJ-45
Mode A 1/2(+) 3/6(-)
PoE Power Budget
140W
300W
300W
Forwarding Mode
Storage-and-Forward
Switching Capacity
5.6G
7.2G
8.8G
Forwarding Rate
4.16Mpps
5.33Mpps
6.54Mpps
Input Power Supply
AC 100-240V 50/60Hz
Operation Temperature
0 ~40
Storage Temperature
-40 ~70
Operation Humidity
10%~90%RH non-condensing
Storage Humidity
5%~90%RH non-condensing
Fan
1 pcs
2 pcs
2 pcs
Dimensions(L*W*H)
280*179*45mm
440*232*45mm
Network Media(cable)
10BASE-T: UTP category 3, 5 cable ( 100m) 100BASE-TX: UTP category 5,5e cable ( 100m) 1000BASE-T: UTP category 5e,6 cable( 100m)
1000Base-X: MMF or SMF SFP Module
上海博达数据通信有限公司
Shanghai Baud Data Communication Co., LTD.
网址Web: www. bdcom.com.cn
地址Add: 上海浦东张江高科技 园区居里路123
N o.123, Juli Road,Pudong Zhangjiang Hig h-Tech Park, Shanghai
邮编Zip Code: 201203
Loading...