B + B Thermo-Technik DRTR Series Operation Manual

OPERATION MANUAL
Industrial pressure transmitter with voltage or current output
DescriptionDescription
Characteristic features
Product variants from vacuum to 100 bar FS
For measurement of relative pressure
Output standard signal of 0...10 V or 4...20 mA
Temperature compensated
Robust, medium resistant models
Simple assembly
Water and oil resistant
Enclosure IP65
Typical areas of application
• Food technology
• Pneumatics
• High pressure
• Fuel pumps
• Gases
• Fuel cells
Technical Data
Industrial pressure transmitter
Measuring range 0...+100 bar, 6 types
Bursting pressure Residual error linearity / hysteresis Temperature
coefcient
Operating temperature range -20...+80 °C Sensor material Ceramics, Al2O3
Housing material Aluminium AlMgPbCu, blue anodised
Seal Viton
Pressure connection ¼“ female thread
Dimensions 30 x 30 x 89 mm
Connection 4-pole industrial connection, DIN 43650
Protection IP65
Model 4...20 mA
Output signal 4…20 mA, Two-Wire
Permissible load Ra[Ω]=(Uv[V]-10V)/0,02 A
Model 0...10 V
Output signal 0...10 V, Three-Wire
Auxiliary power 12...30 V DC / 5 mA
See table
< ±0,2 % FS TCO < ±0,015 % FS / K TCG < ±0,010 % FS / K
Features
the eld of pneumatics, hydraulics and other industrial applications.
The robust probe housing with enclosure type IP 67 is made of anodised aluminium and is provided with a 1/4“ internal thread for connection to the medium. The electric connection is done with an industrial plug as per DIN 43650. The model with current signal is connected through a current loop. The model with voltage output requires an auxiliary supply.
Besides the standard variants, customer specic models for absolute
pressure with other type of calibration, ratio metric voltage output and also with digital output signal are also available. Further information on OEM-models can be obtained on request! In general the B+B pressure sensors are medium resistant. However we recommend to prove the media compatibility with critical mediums such as electroplating applications (iron trichloride) or oils with unde­ned additives .
-
Technical changes reserved 0141 0316-180 14.08.2015
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen Fon +49 771 83160 | Fax +49 771 8316-50 | info@bb-sensors.com | bb-sensors.com
1 / 2
OPERATION MANUAL
Industrial pressure transmitter with voltage or current output
Available Models
Measuring range Burst pressure Order no. current output Order no. voltage output
-1…0 bar 4 bar DRTR-AL-20MA-RV0 DRTR-AL-10V-RV0
-1…1 bar 4 bar
0…1,6 bar 4 bar DRTR-AL-20MA-R1B6 DRTR-AL-10V-R1B6
0…2,5 bar 6,25 bar DRTR-AL-20MA-R2B5 DRTR-AL-10V-R2B
0…4 bar 10 bar DRTR-AL-20MA-R4B DRTR-AL-10V-R4B
0…6 bar 15 bar DRTR-AL-20MA-R6B DRTR-AL-10V-R6B
0…10 bar 25 bar DRTR-AL-20MA-R10B DRTR-AL-10V-R10B
0…16 bar 40 bar DRTR-AL-20MA-R16B DRTR-AL-10V-R16B
0…25 bar 62,5 bar DRTR-AL-20MA-R25B DRTR-AL-10V-R25B
0…40 bar 100 bar DRTR-AL-20MA-R40B DRTR-AL-10V-R40B
0…60 bar 150 bar DRTR-AL-20MA-R60 DRTR-AL-10V-R60B
0…100 bar 175 bar DRTR-AL-20MA-R100B DRTR-AL-10V-R100B
Relativdruckmessung, 0 bar entspricht Umgebungsdruck!
RTR-AL-20MA-RV1
DRTR-AL-10V-RV1
Connection layout
Pin Voltage output Current output
1 +DC 12…30 V +DC 10…30 V
2 GND 0 V
3 U PRESSURE 0…10 V ...
4 SHIELD SHIELD
PRESSURE 4…20 mA
Connection diagram
Voltage output 0...10 V Current output 4...20 mAA
Dimensions
Attention
Please avoid extreme mechanical and inappropriate exposure.
With ¼“ manometer connection
For further information, visit our website: www.bb-sensors.com
Technical changes reserved 0141 0316-180 14.08.2015
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen Fon +49 771 83160 | Fax +49 771 8316-50 | info@bb-sensors.com | bb-sensors.com
The device/product is not suitable for potential explosive areas and medical-technical applications.
2 / 2
Loading...