Industrial Modbus
Ethernet to Serial Gateways
MESR900 Series - Fiber Models
PRODUCT FEATURES
• EthernetenableModbusRS-232/422/485
• ModbusTCP,ASCII&RTU
• Modbusexibility–serial&Ethernet,
Masters & slaves
• Modbusmessagingprioritycontrol
• Viewmessagingstatusinrealtime
• CompleteEthernetberoptions
• Easycongurationsoftware
MESR Modbus Gateways bridge devices on Modbus serial networks (RS232, RS-422 or RS-485) with those on Modbus TCP networks, allowing
seamless integration. Serial ports can be accessed over a LAN or WAN
using Direct IP Mode connections. Supporting up to 16 masters and 32
slaves, these gateways feature autodetecting10/100 copper and fiber
optic options. Easy-to-use software is designed for Windows 2000, 2003
Server, XP, Vista, 2008 Server and Windows 7. Serial data rates up to 230
kbps ensure maximum network flexibility. MESR9xx gateways are built for
use in industrial environments, featuring a slim IP30 DIN rail mountable
case. They operate from a range of DC power supply voltages and have
pluggable terminal block connectors. An external power supply, sold
separately, is required. The MESR92x units have an additional Ethernet
port which functions much like an Ethernet Switch, allowing pass-through
connectivity for other Ethernet devices. This port can also be used to
“daisy chain” multiple gateways. MESR90x units have one Ethernet port.
B&B Electronics’ Vlinx™ is your number one choice for Ethernet to Serial
conversion.
MECHANICAL DIAGRAM MESR92X MODELS
ORDERING INFORMATION
MODEL NUMBER
MESR901-MC 1
MESR901-MT 1
MESR901-SC* 1
MESR901-ST* 1
MESR902T-MC 2 Terminal Block
MESR902T-MT 2 Terminal Block
MESR902T-SC* 2 Terminal Block
MESR902T-ST* 2 Terminal Block
MESR921-MC 1
MESR921-MT 1
MESR921-SC* 1
MESR921-ST* 1
MESR922T-MC 2 Terminal Block
MESR922T-MT 2 Terminal Block
MESR922T-SC* 2 Terminal Block
MESR922T-ST* 2 Terminal Block
SERIAL
PORTS
SERIAL
CONNECTOR
DB9 or Terminal
Block
DB9 or Terminal
Block
DB9 or Terminal
Block
DB9 or Terminal
Block
DB9 or Terminal
Block
DB9 or Terminal
Block
DB9 or Terminal
Block
DB9 or Terminal
Block
ETHERNET
PORTS
Multi-mode
Fiber
Multi-mode
Fiber
Single-mode
Fiber
Single-mode
Fiber
Multi-mode
Fiber
Multi-mode
Fiber
Single-mode
Fiber
Single-mode
Fiber
Multi-mode
Fiber, Copper
Multi-mode
Fiber, Copper
Single-mode
Fiber, Copper
Single-mode
Fiber, Copper
Multi-mode
Fiber, Copper
Multi-mode
Fiber, Copper
Single-mode
Fiber, Copper
Single-mode
Fiber, Copper
ETHERNET
CONNECTOR
(1) SC
(1) ST
(1) SC
(1) ST
SC
ST
SC
ST
(1) SC, (1) RJ45
(1) ST, (1) RJ45
(1) SC, (1) RJ45
(1) ST, (1) RJ45
(1) SC, (1) RJ45
(1) ST, (1) RJ45
(1) SC, (1) RJ45
(1) ST, (1) RJ45
10.11 cm
3.98 in
www.bb-elec.com
14.86 cm
5.85 in
2.95 cm
1.16 in
|
+ All serial ports are software configurable for RS-232, RS-422, or RS-485.
* 40km and 80km options available.
For Copper options please see page 166.
ACCESSORIES
MDR-20-24 - DIN rail mount power supply 24VDC, 1.0 A output power
MDR-40-24 - DIN rail mount power supply 24VDC, 1.7 A output power
DRPM25 - 35mm DIN Rail to Panel Mount Bracket, 25mm wide
ERS35 - DIN Rail 1 Meter 35mm Steel
MESR900 - Fiber Models_3713ds
Ethernet to Serial Gateways
SPECIFICATIONS
SERIAL TECHNOLOGY
RS-232 TD, RD, RTS, CTS, DTR, DSR, DTD, GND
RS-485 2-Wire Data A(-), Data B(+), GND
RS-422/485 4-Wire TDA(-), TDB(+), RDA(-), RDB(+), GND
Serial Connector DB9M or Removable Terminal Blocks, 12 to 28 AWG
Data Rate Up to 230.4 Kbps
FIBER OPTIC TECHNOLOGY
MESR9xx-Mx MESR9xx-Sx
Type / Wavelength Multi-mode / 1310 nm Single-mode / 1310 nm
Output Power (-) 19 to (-) 14 dBm (-) 15 to (-) 8 dBm
Receive Sensitivity ~ (-) 32 dBm ~ (-) 32 dBm
Cable 62.5 / 125 µm 9 / 125 µm
Connector SC or ST SC or ST
Range 2 km (1.2 miles) 15 km (9.3 miles)
MESR9xx-Sx40 MESR9xx-Sx80
Type / Wavelength Single-mode / 1310 nm Single-mode / 1510 nm
Output Power (-)5 to 0 dBm (-) 5 to 0 dBm
Receive Sensitivity ~ (-) 34 dBm ~ (-) 34 dBm
Cable 9 / 125 µm 9 / 125 µm
Connector SC or ST SC or ST
Range 40 km (5 miles) 80 km (49.7 miles)
POWER
Source External
Input Voltage 10 to 48 VDC (58 VDC Maximum)
Connector Removable Terminal Block (12 – 28 AWG)
POWER
CONSUMPTION
MESR90x 4.0 Watts
MESR92x 6.0 Watts
MECHANICAL
LED Indicators Serial Port, Ethernet Link, Ready
Switches Reset Button
Dimensions
Enclosure 35mm DIN mount, Plastic, IP 30
Weight
eDrawing Available on website
MESR90x: 11.94 x 8.03 x 2.96 cm (4.70 x 3.16 x 1.16 in)
MESR92x: 14.86 x 10.11 x 2.96 cm (5.85 x 3.98 x 1.16 in)
MESR90x: 0.33 lbs (149.7 g)
MESR92x: 0.45 lbs (201.4 g)
Industrial Modbus
MESR900 Series - Fiber Models
ENVIRONMENTAL
Operating Temperature -40 to 80°C (-40 to 176°F)
Operating Humidity 0 to 95% Non-condensing
MTBF MESR90X ~ 132309 hours
MTBF MESR92X ~ 102593 hours
MTBF Calc Method Parts Count Reliability Prediction
NETWORK
Serial Memory 8 KB per port
Network Memory 4 KB
IP Port Addresses
LAN 10/100 Mbps Auto-detecting
Ethernet IEEE 802.3 auto detecting & auto MDI/MDX 10/100
PROTOCOLS
TCP, IPv4, ARP, HTTP 1.0, ICMP/PING, DHCP/BOOTP
IP Mode Static, DHCP
TCP User definable
OTHER
Mode
Search
Diagnostics Display PC IP, ping, save test config. (text readable)
Firmware Upgrade Vlinx Manager
ETHERNET PASS-THROUGH PORT (MESR92X)
Standards IEEE 802.3, 802.3u, 802.3x
Processing Type
Flow Control IEEE 802.3x flow control, back pressure flow control
MAC Address Table 2K
CONFIGURATION SOFTWARE
Vlinx Manager
REGULATORY
Compliance FCC, CE, NEMA TS2
5300 – Heartbeat and configuration
Setting in TCP Mode (paired mode)
8899 – MESR 9xx Update
Modbus RTU Master / Slave
Modbus ASCII Master / Slave
Serial direct COM and Ethernet
Auto search or specific IP
Store and Forward with 802.3x full duplex, non blocking
flow control
Windows 2000, XP (32/64 bit), 2003 Server (32/64 bit),
Vista (32/64 bit), 2008 Server (32/64 bit), Win 7
(32/64 bit)
UL Listed, File E222870
UL Class 1 Division 2 Groups A, B, C, D (HAZLOC),
File E245458
orders@bb-elec.com
support@bb-elec.com
International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445