B&B Electronics MESR321-SL-ML Quick Start Guide

Product Overview
Power 10 - 48 VDC
Mode Switch
5. Click “Login”. Password is blank from factory. No password is necessary to operate the MESR unit. The Configuration/General page appears.
Fiber/Ethernet Ports
LEDs
Male DB9 Port
Terminal Block Port
1
1. Power the device.
2. Connect the top RJ45 or optical connector to a network drop using a standard network cable. (The RJ45 ports on the model shown are interchangeable. One may used for pass-through Ethernet.)
3. Connect the Serial Device(s). RS-232 with DB9: straight-through for DCE device. Null modem for DTE device. RS-422/485 with terminal blocks.
2
1. Use included CD to install Vlinx Modbus Gateway Manager. If Autorun does not start, go to “My Computer” and select the CD drive. You will see a Vlinx MESR icon. Double-click it to launch the installation.
2. To open Vlinx Modbus Gateway Manager: click Start/Programs/B&B Electronics/Vlinx/Vlinx Modbus Gateway Manager/Vlinx Serial Server Manager. If the device does not connect, cycle (unplug-replug) the power, then try again.
3. To configure via the network, select “Network”.
4. If you know the IP address, select “The device is at this address,” and type in the IP address. If not, select “I don’t know the IP address of the device.” Click Connect.
(Alternative Method: Open a web browser and type the IP address of the Gateway in the Address Bar. When the Gateway is found the Login window will appear.)
Set Up Hardware
Install/Setup
3
“I want DHCP” is preselected to set up the network using dynamic IP addressing. The Gateway is set up at the factory to receive an IP assignment from a DHCP Server.
1. If a DHCP Server is not available on your network, it will default to 169.254.102.39.
2. If a DHCP server is not available and the default address does not work on your PC, change your PC network settings to IP Address: 169.254.102.1, Subnet Mask: 255.255.0.0, Default Gateway:
169.254.102.10 0.
If you are not able to use these settings in your installation, refer to the User’s Manual for directions to change the Gateway’s TCP/IP settings.
4
Note: The Vlinx Modbus Gateway Manager software contains default parameter values that are common to most Modbus networks.
1. TCP Settings: “Connect to port” identifies TCP port used in TCP client mode. Valid range is 1 to 65535. Default is
502. Response timeout is the maximum response time. Valid range is from 1 to 65535. Default is 100ms.
2. TCP Server Settings: “Listen on port” identifies TCP port in TCP server mode. Valid range is from 1 to 65535. Default is
502. “Limit the number of connections” controls the number of simultaneous TCP clients that can be connected. Connection Filter Mode options like “allow everyone,” “allow specific IP address” and “allow a range of IP addresses” control which TCP clients can connect.
Set Up Network
If You Wish to Set Up TCP
Troubleshooting
The primary check for correct operation is the device LEDs.
For advanced information, see the Configuration Manager menu, at the top of Vlinx Modbus Gateway screen.
Recommended Accessories and Power Supplies
PS12BVLB-INT-MED
Power Supply http://www.bb-elec.PS12BVLB-INT-MED DFMM- LCLC
Q S G
uick tart uide
Select Diagnostic for a check of communications status with attached MESR321 device, and then select the device for which the communications check is desired. A report of reply times and ping statistics is generated and can be saved.
Select Monitor to review activity logs of attached MESR321 devices, then select the device for which logged information is needed.
Logged information includes Time, Source & Destination, Type of Event, Subscriber ID, Data Collected, and Information the Vlinx Modbus Gateway Manager program has gathered since current login of the affected device.
DFMM-LCLC
Fiber Cable http://search.bb-elec.com/?s=PPC_ GUIDE&q=DFMM-LCLC
Ethernet Cables
http://search.bb-elec.com/?q= ethernet+cable
Fast East Answers
You can use your smart phone to access complete documentation on our website. Simply scan the code to the right.
1-888-948-2248 | Europe: +353 91 792444
www.bb-elec.com
MESR321
Isolated Industrial MODBUS
Ethernet to Serial Gateways
First Things First...
Before you begin, be sure you have the following:
MESR321
CD with software and manuals
Mounting accessories kit
Additional items required but not included:
Ethernet cable(s) Null modem cable(s) Power Supply for terminal block or barrel connector
Document number – pn9759_MESR321-xx_r0_4212_qsg
707 Dayton Road | PO Box 1040 | Ottawa, IL 61350
Phone: 815-433-5100 | Fax: 815-433-5109 www.bb-elec.com | E-mail: info@bb-elec.com
© 2012 B&B Elect ronics Manufactur ing Company
Fast and easy on the web:
www.bb-elec.com