B&B Electronics ESR901WB User Manual

r
p
p
p
)
A
Quick Start Guide
ESR901WB Wireless 802.11b
Serial Serve
Model: ESR901WB
CCoonnffiigguurree WWeebb AAcccceessss
1
Infrastructure Mode
Configure your network using an access point with the SSID ­Connect and all encryption disabled (such as WEP & WPA).
Wireless Card Ad-Hoc Mode
Configure the wireless card to operate in Ad-Hoc mode with the SSID - Connect.
u
SSeettu
tthheeHHaarrddwwaarre
2
Connect your PC to the wireless networkConnect the antenna to the ESR901WB Connect 10 VDC to 30 VDC to the power supply
terminals of the ESR901WB
Connect the ESR901WB serial port to the serial
port of your serial device. (Use a null cable if the serial device is a DTE.)
PPoowweerr iitt uupp
3
pply power to the ESR901WB
The Link LED (yellow) will blink while looking for the
wireless network. When a connection is established with the network the Link LED will illuminate steadily. The ESR901WB will connect to the SSID Connect. If it cannot find an SSID of connect it will connect to the first unsecured network it finds.
The ESR901WB will automatically try to obtain an IP
address though DHCP, or generate one itself
Documentation Model Number ESR901WB-2907qs PN6871-rev002
LLooggiinn
5
In a web browser on your PC, type in the
IP address and access the Web Configuration and Management Interface
Login using the username ‘root’ and
password ‘dbps’
CCoonnffiigguurree tthhee EESSRR990011WWBB
e
6
In the Configuration, Network page configure
your Wireless LAN, Security and other settings to work on the type of wireless network you will be connecting to.
In the Configuration, Serial Ports page select
the Port Profile you require for use with your application (E.g. RealPort for virtual COM port, TCP Server, UDP server, Serial Bridge, etc)
Configure the serial port settings for the
selected Port Profile (E.g. In TCP Sockets select client or server, TCP port numbers, etc.) Also configure baud rate, data bits, etc in Basic Serial Settings.
Configure any required alarms and notification If RealPort profile was selected (virtual COM
ort) do the next step (Set up VCOM
upp VVCCOOMM
SSeett u
7
Start the RealPort software wizard (located on the
included CD)
Select Add a New Device Select your ESR901WB from the list Select an unused COM port number Follow the wizard to set up a virtual COM port
Documentation Model Number ESR901WB-2907qs PN6871-rev002
GGeett tthhee IIPP AAddddrreesss
4
Use the discovery software on your CD (finder.exe)
to get the IP address for your ESR901WB
If necessary, change the IP address using the
discovery software
s
International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA
815-433-5100 Fax 433-5104 www.bb-elec.com orders@bb-elec.com support@bb-elec.com
European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland
+353 91 792444 Fax +353 91 792445
Oppeerraattiioonn
O
8
Configure and then start your application
www.bb-europe.com orders@bb-europe.com support@bb-europe.com
Loading...