B&B Electronics ESP904 Datasheet

Model Number
Description
ESP901
Single Port Serial Server, 1 RS-232/422/485 port
ESP902
Dual Port Serial Server, 1 RS-232/422/485 port, 1 RS-232 port
ESP904
Quad Port Serial Server, 4 RS-232/422/485 ports
Features
Ethernet Enable 1, 2 or 4 Serial Ports Compact Panel Mount Case Optional DIN Rail Adapter RS-232/422/485 Full and Half Duplex Auto Detect 10/100 Mbps Ethernet
© 2010 by B&B Electronics. All rights reserved.
Models: ESP901, ESP902 & ESP904
Ethernet Serial Servers
ESP90x_5012ds-1/2
Virtual COM Drivers for Windows 2000, XP, Server 2003, Vista, Server 2008, & Win 7
Functional Description
Ethernet enable any serial device using B&B’s Vlinx Serial Server technology and put your serial ports to work for you. Imagine the ability to communicate with every piece of equipment from any networked PC. Eliminate site visits just to find a need to make a minor configuration change. Reduce service calls and increase productivity by knowing what your equipment is doing before you get a trouble-report. Spend more time doing the work you’re paid to do instead of chasing down nuisance problems with remotely located equipment. Much of today’s high-tech equipment ships with a serial port for programming, monitoring or diagnostics. 80% of these serial ports are left unconnected, often because a person travels to the port to make the
connection or a permanent PC is not desirable. With B&B’s Vlinx Serial Servers, you can put all of those
ports to work for you. Simply connect the Vlinx server to the equipment’s serial port, and connect the Vlinx Ethernet port to your LAN. Your equipment is now online. It will appear as a local COM port on any networked PC running our Virtual Serial Port software. No software customization required, just run the appropriate software for your equipment. The ESP90x family integrate the benefits of Ethernet communications with existing serial devices by offering the combination of three serial interfaces, RS-232, RS-422, and RS-485. The Ethernet connection will auto select 10BaseT or 100BaseTX. These serial servers provide Windows host control over serial devices located virtually anywhere on a TCP/IP or UDP/IP Ethernet connection. They even give authorized users control over the connected serial device and the server configuration from anywhere outside the LAN.
Ordering Information
ESP90x_5012ds-2/2
Accessories
DRAD35
35mm DIN Rail Mounting Kit
Specifications
Serial
Ethernet
Serial Interfaces:
RS-232 (DTE), RS-422, RS-485 (2/4-Wire)
Connector:
RJ-45 F
DIP Switch Selectable
Data Rate:
10/100 Mbps Auto-detecting 10BaseT or
Serial Connectors:
ESP901: 1 x DB9 Male
1000BaseTx
*ESP902: 2 x DB9 Male
Protocols:
TCP, IP, ARP, DHCP, Telnet, HTTP, UDP
ESP904: 4 x DB9 Male
ICMP
Baud Rate:
110 to 230.4 kbps, 5787 bps
Parity:
None, Even, Odd, Mark, Space
Configuration
Data Bits:
5, 6, 7, or 8 Console:
RS-232 w/ VT100 Emulation
Stop Bits:
1, 1,5, or 2 Telnet:
HyperTerminal w/VT100 Emulation
Buffer:
8 Kb per port
ESP Manager:
Compatible with Windows 2000, XP (32/64 bit)
Note: Refer to the manual for pin-outs and signals.
Server 2003 (32/64 bit), Vista (32/64 bit), Server 2008 (32/64 bit), Win 7 (32/64 bit)
*ESP902 has (1) RS-232/422/485 port and (1) RS-232 port
HTTP:
Embedded Web Page
Power (Power Supply Included)
Environment
Voltage:
12 VDC
Operating Temp:
-14 to 176 F (-10 to 80 C)
Current
ESP901: 200 mA
Storage Temp:
-4 to 185 F (-20 to 85 C)
ESP902: 300 mA
Humidity:
5 to 90% Non-condensing
ESP904: 500 mA
Dimensions:
Connector:
2.5 mm Jack (Positive Tip)
ESP901
3.4 x 4.5 x 0.90 in (8.5 x 11.5 x 2.3 cm)
ESP902
3.4 x 4.5 x 0.90 in (8.5 x 11.5 x 2.3 cm)
ESP904
4.5 x 7.3 x 1.1 in (11.4 x 18.5 x 2.9 cm)
Enclosure:
IP 30
Approvals:
CE, FCC
© 2010 by B&B Electronics. All rights reserved.
Operation
A detailed operating manual is contained on the CD ROM which ships with the product.  Vlinx ESP Manager allows easy access to the serial server to configure the server and ports, upgrade
server firmware and monitor port status and activity. When ESP Manager opens it will search for and display all ESP90x serial servers on the network. The Monitor Port feature allows you to use any PC on the LAN/WAN to actively view and troubleshoot the communications status. It shows when there is a client connection to the server and the client IP address. It displays the number of bytes transmitted and received as well as the status of the hardware handshaking lines
ESP901/ESP902/ESP904 serial servers can be accessed and configured from any web browser (such
as Internet Explorer) on the LAN/WAN. This allows you to remotely manage the software and your serial device. It also allows off-site troubleshooting.
ESP901/ESP902/ESP904 serial servers provide automatic resumption of the TCP data connection in
case of a power failure or loss of an Ethernet connection on either the client or server. Once the Heartbeat connection is established the server sends a signal to the client every five seconds. If the signal is not received, the serial server will attempt to reconnect the TCP data connection every five seconds until communication is established again.