B&B Electronics EKI-2541S-SI User Manual

Page 1
EKI-2541M/SC
Ethernet to Multi-mode SC Type Fiber Optic Converter
EKI-2541S/SC
Ethernet to Single-mode SC Type Fiber Optic Converter
User Manual
Page 2
The documentation and the software included with this product are copyrighted 2007 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. However, Advantech Co., Ltd. assumes no responsibility for its use, nor for any infringements of the rights of third parties, which may result from its use.
Acknowledgements
Intel and Pentium are trademarks of Intel Corporation. Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp. All other product names or trademarks are properties of their respective owners.
Part No. Printed in China
EKI-2541M & 2541S User Manual ii
1st Edition April 2007
Page 3
Product Warranty (2 years)
Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for two years from the date of purchase.
This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation. Advantech assumes no liability under the terms of this warranty as a consequence of such events.
Because of Advantechs high quality-control standards and rigorous testing, most of our customers never need to use our repair service. If an Advantech product is defective, it will be repaired or replaced at no charge during the warranty period. For out-of-warranty repairs, you will be billed according to the cost of replacement materials, service time and freight. Please consult your dealer for more details.
If you think you have a defective product, follow these steps:
1. Collect all the information about the problem encountered. (For example, CPU speed, Advantech products used, other hardware and software used, etc.) Note anything abnormal and list any onscreen messages you get when the problem occurs.
2. Call your dealer and describe the problem. Please have your manual, product, and any helpful information readily available.
3. If your product is diagnosed as defective, obtain an RMA (return merchandize authorization) number from your dealer. This allows us to process your return more quickly.
4. Carefully pack the defective product, a fully-completed Repair and Replacement Order Card and a photocopy proof of purchase date (such as your sales receipt) in a shippable container. A product returned without proof of the purchase date is not eligible for warranty service.
5. Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer.
iii
Page 4
Declaration of Conformity
CE
This product has passed the CE test for environmental specifications. Test conditions for passing included the equipment being operated within an industrial enclosure. In order to protect the product from being damaged by ESD (Electrostatic Discharge) and EMI leakage, we strongly recommend the use of CE-compliant industrial enclosure products.
FCC Class A
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Technical Support and Assistance
Step 1. Visit the Advantech web site at www.advantech.com/support where you can find
the latest information about the product.
Step 2. Contact your distributor, sales representative, or Advantech’s customer service center for technical support if you need additional assistance. Please have the following information ready before you call:
- Product name and serial number
- Description of your peripheral attachments
- Description of your software (operating system, version, application software, etc.)
- A complete description of the problem
- The exact wording of any error messages
EKI-2541M & 2541S User Manual iv
Page 5
Safety Instructions
1. Read these safety instructions carefully.
2. Keep this User's Manual for later reference.
3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning.
4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible.
5. Keep this equipment away from humidity.
6. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage.
7. The openings on the enclosure are for air convection. Protect the equipment from overheating. DO NOT COVER THE OPENINGS.
8. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet.
9. Position the power cord so that people cannot step on it. Do not place anything over the power cord.
10. All cautions and warnings on the equipment should be noted.
11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage.
12. Never pour any liquid into an opening. This may cause fire or electrical shock.
13. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel.
14. If one of the following situations arises, get the equipment checked by service personnel:
a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. c. The equipment has been exposed to moisture. d. The equipment does not work well, or you cannot get it to work according to the user's
manual.
e. The equipment has been dropped and damaged.
f. The equipment has obvious signs of breakage.
15. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW -40 (-40) OR ABOVE 85 (185). THIS
COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT.
v
Page 6
Safety Precaution - Static Electricity
Follow these simple precautions to protect yourself from harm and the products from damage.
1. To avoid electrical shock, always disconnect the power from your PC chassis before you work on it. Don't touch any components on the CPU card or other cards while the PC is on.
2. Disconnect power before making any configuration changes. The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components.
EKI-2541M & 2541S User Manual vi
Page 7
Contents
Chapter 1 Overview...........................................2
1.1 Introduction.........................................................2
1.1.1 Fast Fiber Converters Module ................... 2
1.1.2 Dual Power Input ....................................... 2
1.1.3 Flexible Mounting ......................................2
1.1.4 Advanced Protection .................................2
1.1.5 Wide Operating Temperature .................... 2
1.1.6 Easy Troubleshooting................................ 2
1.2 Features.............................................................. 3
1.3 Specification .......................................................4
1.4 Packing List ........................................................6
1.5 Safety Precaution ...............................................6
Chapter 2 Installation........................................8
2.1 LED Indicators .................................................... 8
Table 2.1: EKI-2541M/S LED Definition.....................8
2.2 DIP-Switch..........................................................9
Table 2.2: EKI-2541M/S DIP-Switch Definition.......... 9
2.3 Dimensions (units: mm) .................................... 10
Figure 2.1: Front View of EKI-2541M/S ....................10
Figure 2.2: Side View of EKI-2541M/S......................11
Figure 2.3: Rear View of EKI-2541M/S .....................12
Figure 2.4: Top View of EKI-2541M/S ......................13
2.4 Mounting........................................................... 14
2.4.1 Wall mounting.......................................... 14
Figure 2.5: Combine the Metal Mounting Kit.............14
2.4.2 DIN-rail Mounting..................................... 15
Figure 2.6: Installation to DIN-rail Step 1...................15
Figure 2.7: Installation to DIN-rail Step 2...................16
2.5 Network Connection .........................................17
2.6 Power Connection ............................................17
Figure 2.8: Pin Assignment of the Power Connector ..17
Chapter 3 Troubleshooting ............................20
Appendix A Pin Assignment & Wiring ...........22
Figure A.1: RJ-45 Pin Assignment..............................22
Figure A.2: EIA/TIA-568B .........................................22
Figure A.3: EIA/TIA-568A .........................................22
vii Contents
Page 8
EKI-2541M & 2541S User Manual viii
Page 9
Overview
Sections include:
z Introduction
z Features
z Specifications
z Packing List
CHAPTER
z Safety Precaution
1 Chapter1
Page 10
Chapter 1 Overview
1.1 Introduction
The EKI-2541M/2541S is a cost-effective solution for the converting between 10/100Base-TX and 100Base-FX cabling, it allows you to extend the cabling distance of your 100Base-FX network up to 2 kilometers for multi-mode fiber or 30 kilometers for single-mode fiber. The Fast Fiber Converter module gives you the option to choose from the most popular fiber cabling connectors: SC multi-mode and single-mode connector.
1.1.1 Fast Fiber Converters Module
The EKI-2541M/2541S provides you with one Fiber connector for your fiber optic cable and one Ethernet RJ-45 port (Auto MDI/MDIX) for your 100Base-TX copper cable connection. There are four DIP-switches to set the operation mode for UTP, Fiber ports and Link Fault Pass-Through function.
1.1.2 Dual Power Input
EKI-2541M/2541S redundant power input design is with power reserve protection to prevent the switch device broken by wrong power wiring. When one of power input is fail, P-Fail LED will turn on and send an alarm through a relay output for notifying user.
1.1.3 Flexible Mounting
EKI-2541M/2541S is extremely compact (37 x 140 x 95 mm) and can be mounted on a DIN-rail or a panel, so it is suitable for any space-constrained environment.
1.1.4 Advanced Protection
EKI-2541M/2541S supports up to 3,000 VDC surge protection for power line, and also supports 4000V ESD for Ethernet ports. With these 2 strong protections, it can secure equipment against unregulated voltage and make systems safer and more reliable. Further, EKI-2541M/2541S provides currency overload protection with a resettable fuse to ensure that the device component won’t be damaged by overload current.
1.1.5 Wide Operating Temperature
The operating temperature of the EKI-2541M/2541S is between -40 ~ 75 (wide operating temperature model) or -10 ~ 60 (standard model). With such a wide range, you can use the EKI-2541M/2541S in some of the harshest industrial environments
that exist.
1.1.6 Easy Troubleshooting
LED indicators make troubleshooting quick and easy. The 10/100 Base-TX port has 2 LEDs that display the link status, transmission speed and collision status. Also the three power indicators P1, P2 and P-Fail help you diagnose immediately.
EKI-2541M & 2541S User Manual 2
Page 11
1.2 Features
Provides 1 x 10/100Mbps Ethernet ports with RJ-45 connector
Provides 1 x SC (multi-mode & single-mode) fiber connector
Supports full/half duplex flow control
Supports store & forward transmission
supports auto-negotiation
Supports MDI/MDI-X auto-crossover
Provides surge protection (EFT) 3,000 V
Supports 4,000 V
Supports +12 ~ 48 V
ESD protection for Ethernet
DC
power input
DC
Provides flexible mounting: DIN-rail, Wall Mounting
Supports operating temperatures from -40 ~ 75 (wide operating temperature
model) or -10 ~ 60 (standard model)
for power line
DC
3 Chapter1
Page 12
1.3 Specification
Communications
Compatibility LAN Transmission Distance
Transmission Speed
Interface
Connectors
6-pin removable screw terminal (power & relay)
LED Indicators
Ethernet: 10/100M, LNK/ACT Fiber: HDX/FDX, LNK/ACT
Power
Current Overload Protection Power Consumption
Power Input Fault Output
Mechanism
Dimensions (WxHxD) Enclosure Mounting
Protection
ESD (Ethernet) Surge (EFT for power) Reverse Polarity
Environment
Operating Temperature
Operating Humidity
IEEE 802.3, 802.3u, 802.3x 10/100Base-TX Multi-mode Fiber: Up to 2km Single-mode Fiber: Up to 30km Up to 100 Mbps
1 x RJ-45 1 x SC type fiber connector
Unit: P1, P2, P-Fail
0.9A@12V
2.7 W (EKI-2541M)
2.3 W (EKI-2541S) 2 x Unregulated +12 ~ 48 V 1 Relay Output
37 x 140 x 95 mm IP30, Metal shell with solid mounting DIN-rail, Wall
4000 V 3000 V Present
-10 ~ 60 (EKI-2541M/2541S)
-40 ~ 75 (EKI-2541MI/2541SI) 5% ~ 95% (non-condensing)
DC
DC
(25)
DC
DC
kits
EKI-2541M & 2541S User Manual 4
Page 13
Storage Temperature
Certifications
Safety EMC
EU: EN55011, EN61000-6-4 EN55022, Class A, EN61000-3-2/3 EN55024 IEC61000-4-2/3/4/5/6/8/11/12 EN61000-6-2
Free Fall Shock Vibration
-40 ~ 85
UL, 60950-1, CAN/CSA-C22.2 No.60950 U.S.A.: FCC Part 15 CISPR 22
IEC60068-2-32 IEC60068-2-27 IEC60068-2-6
5 Chapter1
Page 14
1.4 Packing List
1 x EKI-2541M or EKI-2541S Industrial Ethernet to Fiber Optic Converter
1 x eAutomation Industrial Communication CD-ROM with software, and User manual
2 x Wall Mounting Bracket and Screws
1 x DIN-rail Mounting Bracket and Screws
1 x EKI-2541M/2541S Startup Manual
1 x
DC Jack Cable 2.0/150mm
1.5 Safety Precaution
Attention IF DC voltage is supplied by an external circuit, please use a protection device
on the power supply input.
EKI-2541M & 2541S User Manual 6
Page 15
Installation
Sections include:
z LED Indicators
z Dimensions
z Mounting
z Network Connection
CHAPTER
z Power Connection
7 Chapter2
Page 16
Chapter 2 Installation
In this chapter, you will be given an overview of the EKI-2541M/2541S hardware installation procedures.
2.1 LED Indicators
There are few LEDs display the power status and network status located on the front panel of EKI-2541M/2541S, each of them has its own specific meaning as below table.
Table 2.1: EKI-2541M/S LED Definition
LED Color Description
On Power input 1 is active
P1 Green
Off Power input 1 is inactive
On Power input 2 is active
P2 Green
Off Power input 2 is inactive
On Power input 1 or 2 has failed
P-Fail Red
Off Power input 1 and 2 are both functional, or no power input
On Ethernet port full duplex
HDX/FDX (fiber port) Yellow
Off Ethernet port half duplex or not connect to network
On Connected to network
LNK/ACT (fiber port) Green
10/100M (RJ-45) Yellow
LNK/ACT (RJ-45) Green
Flashing Networking is active
Off Not connected to network
On Link to 100M bps network
Off Link to 10M bps network
On Connected to network
Flashing Networking is active
Off Not connected to network
EKI-2541M & 2541S User Manual 8
Page 17
2.2 DIP-Switch
The DIP-Switch is used to configure operation mode for LFP (Link Fault Pass-
Through) and operation mode for UTP/Fiber port. The default value of DIP-switch is OFF.
Table 2.2: EKI-2541M/S DIP-Switch Definition
S/W No Status Description
1
2
3
4
LFP (Link Fault Pass-Through): When LFP is enabled, it allows UTP link failures to be reported to the fiber side and also allows Fiber link failures to be reported to the UTP side. Therefore, an LFP feature is provided in both UTP and Fiber side.
Pure Converter mode (DIP-Switch 4): When pure converter mode is enabled (on), it operates with the minimum latency. The transmission flow does not wait until entire frame is ready, but instead it forwards the received data immediately after the data being received. And UTP port should be forced at 100M in this application. When DIP­Switch is in Switch Converter mode (off), the converter function is same as Switch
Note Please don’t change the DIP-switch setting when UTP or fiber port is
ON Enables Port/Power Alarm
OFF Disable Port/Power Alarm
ON Enables LFP
OFF Disables LFP
ON 100Base-FX Half-mode
OFF 100Base-FX Full-mode
ON Pure Converter mode (100TX to 100FX)
OFF Switch Converter mode
transmitting or receiving data. It may cause some data error. Besides, if you change the DIP-switch setting, please power off the converter and power on again to make the setting effective.
9 Chapter2
Page 18
2.3 Dimensions (units: mm)
Figure 2.1: Front View of EKI-2541M/S
EKI-2541M & 2541S User Manual 10
Page 19
Figure 2.2: Side View of EKI-2541M/S
11 Chapter2
Page 20
Figure 2.3: Rear View of EKI-2541M/S
EKI-2541M & 2541S User Manual 12
Page 21
Please refer to page 16 for pin assignment.
Figure 2.4: Top View of EKI-2541M/S
13 Chapter2
Page 22
2.4 Mounting
The EKI-2541M/2541S supports two mounting methods: DIN-rail & Wall.
2.4.1 Wall mounting
EKI-2541M/2541S can be wall-mounted by using the included mounting kit. Then, hang on the EKI-2541M/2541S to the nails on the wall. First, use the screws included in the package to combine the EKI-2541M/2541S and metal mounting kit. And then you can install the device firmly via the components, please see Figure 2.5 as below.
Figure 2.5: Combine the Metal Mounting Kit
EKI-2541M & 2541S User Manual 14
Page 23
2.4.2 DIN-rail Mounting
You can also mount EKI-2541M/2541S on a standard DIN-rail by below steps.
The DIN-rail kit is screwed on the industrial switch when out of factory. If the DIN-rail kit is not screwed on the industrial switch, please screw the DIN-rail kit on the switch first.
First, hang the EKI-2541M/2541S to the DIN-rail with angle of inclination. See figure
2.6.
Figure 2.6: Installation to DIN-rail Step 1
15 Chapter2
Page 24
Then, let the device down straight to slide over the rail smoothly. See Figure 2.7
Figure 2.7: Installation to DIN-rail Step 2
EKI-2541M & 2541S User Manual 16
Page 25
2.5 Network Connection
Twisted-pair segment can use unshielded twisted pair (UTP) or shielded twisted pair (STP) cabling. The cable must comply with the IEEE 802.3u 100Base-TX standard for Category 5. The cable between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
Fiber segment using single-mode connector type must use 9/125µm single-mode cable. You can connect two devices in the distance of 30 kilometers in full-duplex
operation. For half-duplex operation, the recommended maximum distance is 412 meters (1,352 ft.).
Fiber segment using multi-mode connector type must use 50 or 62.5/125μm multi-
mode fiber cable. You can connect two devices up to a 2-kilometer (6,562 ft.) distance.
2.6 Power Connection
The EKI-2541M/2541S supports dual +12 ~ 48 V output.
power inputs and power-fail relay
DC
Figure 2.8: Pin Assignment of the Power Connector
You can connect an alarm indicator, buzzer or other signaling equipment through the relay output. The relay opens if power input 1 or 2 fails ( “Open” means if you connect relay output with an LED, the light would be off).
17 Chapter2
Page 26
EKI-2541M & 2541S User Manual 18
Page 27
CHAPTER
Troubleshooting
19 Chapter2
Page 28
Chapter 3 Troubleshooting
1. Power Input
Verify that is using the right power cord/adapter (+12~48 V power adaptor with DC output voltage higher than 48V, or it will burn this converter down.
2. Cable Select the proper UTP/Fiber cable to construct your network. The single-mode converter must use single-mode fiber cable. Please check that you are using the right cable.
3. DIP Switch Check the configuration DIP-switch. It must be setting in the same operation mode with the link partner.
4. Diagnosing LED Indicators
The switch can be easily monitored through panel indicators, which describes common problems user may encounter and where user can find possible solutions, to assist in identifying. If the power indicator does not light up when the power cord is plugged in, user may have a problem with power cord. Then check for loose power connections, power losses or surges at power outlet. If user still cannot resolve the problem, contact the local dealer for assistance. If the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit, please check your system’s Ethernet devices configuration or status.
), please don’t use the
DC
EKI-2541M & 2541S User Manual 20
Page 29
APPENDIX
Pin Assignment & Wiring
21 Chapter2
Page 30
Appendix A Pin Assignment & Wiring
It is suggested to adopt ELA/TIA as the wiring of the RJ-45.
Figure A.1: RJ-45 Pin Assignment
Figure A.2: EIA/TIA-568B
Figure A.3: EIA/TIA-568A
EKI-2541M & 2541S User Manual 22
Loading...