B&B Electronics EIRP305-T Quick Start Guide

EIRP305-T-1012qsg
p
Quick Start Guide
Elinx PoE Ethernet Switch
EIRP305-T
1
Items Included
o Ethernet Switch o CD with Support Manual o This Quick Start Guide
o Panel Mount Bracket
Hardware Installation
1. Select a mounting location and install the switch onto a piece of DIN rail or use the included panel mount brackets for wall or panel mounting
2. Connect power to the switch 48 VDC
3
LED Description
P1
P2
Fault
FWD (1 to 4)
RJ-45 Upper LED
RJ-45 Lower LED
If redundancy is desired be sure to
connect two separate power supplies by using the two DC inputs on the terminal blocks
If only one power input is used the Fault
LED will light (this is normal)
LED Chart
Green Power input 1 is active Off Power input 1 is inactive Green Power input 2 is active Off Power input 2 is inactive Red Power input 1 or 2 is inactive
Off
Green
Off Green Connected to network
Flashing Networking is active Off Not connected to network Yellow Full-duplex link Flashing Collision occurs Off Half-duplex link or link down
Power input 1 and 2 are both active, or no power is present
The port is supplying power to the connected device
No device attached or no power being supplied
4
RJ-45 ports: The RJ-45 ports auto-sense for 10 or 100 Mbps device connections. The auto MDI/MDIX feature allows connections to switches, workstation and other equipment without changing straight through or crossover cabling. The charts below show the cable pin assignments for straight through and crossover cables.
1. Auto MDI/MDI-x is supported. A straight through or cross-over cable may be used.
2. 10/100 auto negotiation and full/half­du
lex are supported.
PoE ports: The PoE ports on this switch follow Alternative A standards and are limited to 15.4 Watts of power output per port. Ports 1 thru 4 support the IEEE802.3af standard and are classified as (PSE) power sourcing equipment, which means they can be used to power (PD) powered devices.
5
1. When the network cables are attached and power
2. The switch will automatically discover network
Installation Complete
is applied, installation is complete.
devices, populate its MAC address table, and pass traffic to the appropriate ports.
Ports
MDI Cable Pinout
Pin Signal
1 Tx+ 2 Tx­3 Rx+ 6 Rx-
MDI-X Cable Pinout
Pin Signal
1 Rx+ 2 Rx­3 Tx+ 6 Tx-