B&B Electronics Mfg. Co. Inc. shall not be liable for incidental or consequential damages resulting from the
furnishing, performance, or use of this manual.
All Brand names used in this manual are the registered trademarks of their respective owners. The use of trademarks or other
designations in this publication is for reference purposes only and does not constitute an endorsement by the trademark holder
Features ....................................................................................................................................................... 2
iii Manual Documentation Number EIR405-SFP-T-0912m
Packing List .................................................................................................................................................. 2
Front Panel................................................................................................................................................... 3
Top View ...................................................................................................................................................... 4
Wiring the Power Inputs ...............................................................................................................................4
Wiring the Fault Alarm Contact .................................................................................................................... 5
LED Indicators.............................................................................................................................................. 6
The EIR405-SFP-T is an industrial DIN mount, unmanaged 5 port Gigabit Ethernet
switch. It has (4) 10/100/1000 copper Ethernet ports and (1) SFP slot used for Gigabit
fiber options.
The SFP Advantage
The SFP fiber slot provides flexibility when planning and implementing a network. The
SFP slot can accept any SFP-type fiber module and is capable of transmitting distances of
500m in (multi-mode) and 10km, 20km, and greater in (single-mode). The SFP slot
also supports SFP modules used for WDM single-fiber transmissions. This means that
you can easily change the transmission mode and distance of the switch by simply pulling
out the SFP module and plugging in a different module. The SFP modules are
hot-swappable and plug-and-play.
High-Speed Transmissions
Overview
The EIR405-SFP-T includes a switch controller that can automatically sense transmission
speeds (10/100/1000 Mbps). The RJ-45 interface can also be auto-detected, so MDI or
MDI-X is automatically selected and a crossover cable is not required. All Ethernet ports
have memory buffers that support the store-and-forward mechanism. This assures that
data is properly transmitted
Dual Power Input
To reduce the risk of power failure, the EIR405-T provides two 12 to 48 VDC power
inputs. If the power fails, the switch will automatically switch to the secondary power
input. Also if the power goes out the corresponding P1 or P2 LED will go out and the
Fault LED will light. The contacts for the alarm output will also open.
Flexible Mounting
The EIR405-SFP-T can be DIN or Panel mounted. The compact design is suitable for
space-constrained environments such as a small cabinet.
Page 5
Overview
2
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
Advanced Protection
The power line input on the EIR405-SFP-T supports up to 3,000 VDC EFT protection,
which secures the equipment against unregulated voltages and makes the system safer
and more reliable. The Ethernet ports support up to 4,000 VDC ESD protections which
makes the switch suitable for harsh environments.
Wide Operating Temperature
The operating temperature of the EIR405-SFP-T is -40 to 75oC. This wide range allows
the switch to be used in some of the harshest industrial environments that exist.
Easy Troubleshooting
LED indicators make troubleshooting quick and easy. There are 2 LED’s for each port
that display the link status and transmission speed. Three LED’s P1, P2 and Fault help
you diagnose if power is present.
Features
•
Provides 4 x 10/100/1000Base-T Mbps Ethernet ports
•
Provides 1 x SFP (mini-GBIC) port
•
Supports full/half duplex flow control
•
Supports auto-negotiation (10/100/1000)
•
Supports MDI/MDI-X auto-crossover
•
Supports MAC Address up to 8Kbytes
•
Supports Jumbo Frame of 9Kbytes
•
Supports surge (EFT) protection 3,000 VDC for power input
EIR405-SFP-T, 5 Port Gigabit Industrial Ethernet Switch
•
Quick Start Guide
•
CD ROM with User Manual
•
Wall Mounting Bracket and Screws
Page 6
Hardware Description
Front Panel
The Front Panel of the EIR405-SFP-T is shown below.
Hardware Description
3 Manual Documentation Number EIR-SFP-T-0912M
www.bb-elec.com
www.bb-europe.com
Page 7
Hardware Installation
4
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
Top View
The top panel view of the EIR405-SFP-T is equipped with one terminal block connector
that consists of two 12 to 48 VDC power inputs and the fault alarm output.
Wiring the Power Inputs
Follow the steps below to insert the power wires.
1. Insert the positive and negative wires into the V+ and V- contacts on the terminal block
connector.
2. Tighten the wire-clamp screws to prevent the wires from becoming loose.
Page 8
Hardware Installation
5
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of terminal block connector as shown below. If
one of the power sources fails a fault will be detected causing the circuit to open.
Insert the wires into the fault alarm contact (No. 3 & 4)
Note The wire gauge for the terminal block should be 12 to 24 AWG.
Page 9
Hardware Installation
6
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
LED
Color
Description
P1 Green
On
Power input 1 is active
Off
Power input 1 is inactive
P2 Green
On
Power input 2 is active
Off
Power input 2 is inactive
Fault
Red
On
Power input 1 or 2 is inactive
Off
Power input 1 and 2 are both functional, or no power is
applied
LNK/ACT (SFP)
Green
On
Connected to network
Flashing
Networking is active
Off
Not connected to network
Ports 1 to 4
(Upper LED)
Green
On
Connected to network
Flashing
Networking is active
Off
Not connected to network
Ports 1 to 4
(Lower LED)
Green
On
Connected to network at speeds of 1000Mbps
Off
Not connected to network
Pin Number
Assignment
1
Tx+
2
Tx-
3
Rx+
6
Rx-
LED Indicators
Below is a table that explains the status of each the power and network status LED’s
found on the front panel of the EIR405-SFP-T.
Ports
RJ-45 ports: The RJ-45 ports auto-sense for 10, 100 or 1000 Mbps devices connections.
The auto MDI/MDIX feature allows connections to switches, workstation and other
equipment without changing straight through or crossover cabling. The charts below
show the cable pin assignments for straight through and crossover cables.
RJ-45 Pin Assignments
Note “+” and “-” signs represent the polarity of each wire pair.
Page 10
Hardware Installation
7
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
Pin
MDI-X Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)
All copper ports on the EIR405-SFP-T support automatic MDI/MDI-X operation, you
can use straight-through cables (See Figure below) for all network connections to PCs or
servers, or to other switches or hubs. In straight-through cables, pins 1, 2, 3, and 6, at one
end of the cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of
the cable. The table below shows the 10BASE-T / 100BASE-TX MDI and MDI-X port
pin outs.
Straight Through Cable Schematic
Cabling
Cross Over Cable Schematic
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable.
10Mbps: Use category 3, 4, 5 or greater cable
100Mbps: Use category 5 or greater
1000Mbps: Use category 5e or greater cable
Cable distances should be less than 100 meters (328 ft.) long.
Page 11
Hardware Installation
8
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
The small form-factor pluggable (SFP) is a compact optical transceiver.
Page 12
Hardware Installation
9
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
To connect the transceiver and fiber cable, follow the steps below. (Note: SFP
modules typically terminate with an LC fiber connector)
First, insert the SFP transceiver into the SFP module cage. Notice that the triangle mark
is at the bottom of the module.
Transceiver Inserted
Page 13
Hardware Installation
10
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
Second, insert the fiber cable into the transceiver.
LC fiber cable shown installed into the transceiver
Removing the LC fiber cable and SFP transceiver, follow the steps below:
First, press the upper side of the LC connector down and pull it out before releasing.
Remove LC connector
Page 14
Hardware Installation
11
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
Second, swivel the metal latch away from the switch and pull the transceiver out.
Pull out the SFP module
Page 15
Hardware Installation
12
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
DIN-Rail Mounting
The DIN rail clip comes screwed on to the switch, from the factory. If the DIN rail clip is
not screwed on the switch, please see the following figure to re-attach the DIN-Rail clip.
Then follow the steps below to hang the switch onto a DIN rail.
Mounting Installation
1. Use the screws to screw the DIN rail clip onto switch.
2. To remove the DIN rail clip, reverse step 1.
Page 16
Hardware Installation
13
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
3. First, insert the top of DIN rail clip onto the piece DIN rail track.
4. Then, lightly push the bottom of the switch so it can snap the rest of the way onto the
DIN rail track.
5. Check that the switch is held tightly to the DIN rail track.
Page 17
14
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
Hardware Installation
6.
To remove the switch from the track, reverse the steps above.
•First pushing down lightly on the switch will give enough room for the bottom of
the switch to clear the bottom of the DIN rail track.
•Pulling slowly at the bottom of the switch will bring the switch out so that the
switch can now be carefully lifted off the DIN rail track.
Wall or Panel Mount Plate Mounting
Follow the steps below to mount the switch with the wall mount plates.
1. Remove the DIN rail clip from the switch; loosen the screws to remove the DIN rail clip.
2. Place the wall mount plate on the side panels of the switch.
3. Use the screws to screw the wall mount plate onto switch.
4. Use the hook holes at the corners of the wall mount plates to hang the switch on the wall.
5. To remove the wall mount plate, reverse the above steps.
Page 18
Hardware
Installation
Hardware
The diagram below shows a typical switch installation for the
15 Manual
Data collect server
Distribute 1/0
control
system
Field Automatic
device
Indus
trial
Switc
h
erial
Field Automatic
Industria l
Device Server
device
Installation
EIR405-SFP
Human Management Interfa
Switch
Field Automatic de
Documentation
-T.
Field
Programma
logic controller
Number El
www
ce
Management
ble
vice
R-SFP-T
www
.
bb-europe.com
-0912
.
bb-elec.com
M
Page 19
Hardware Installation
Installation Steps
1. Unpack the switch.
2. Check that the DIN rail clip is screwed onto the switch. If the DIN rail clip is not screwed
onto the switch, please refer to DIN-Rail Mounting section for DIN-Rail installation. If
you want to wall or panel mount the switch, then please refer to Wall or Panel Mount Plate Mounting section for wall place installation.
3. Apply power to the switch. If you need help with this please refer to the Wiring the
Power Inputs section. The power LED on the switch will light up. Please refer to the LED
Indicators section for meaning of LED lights.
4. Prepare the twisted-pair, Ethernet cable for connection.
5. Insert one side of cable into one of the switches Ethernet ports and the other side of the
cable to the network device you want connected ex: switch, PC or Server. The port LED on
the Industrial switch will light up when the cable is connected to the network device. Please
refer to the LED Indicators section for LED light meaning.
6. When all connections are made and the LED lights show normal activity the installation is
complete.
16 Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
Page 20
Trouble shooting
Trouble shooting
•
Verify that you are using a power supply ranging from 12 to 48VDC. Applying
more than 48VDC could cause damage to the switch.
•
Be sure the proper cable is used in your network. Refer to the Cabling section
of this manual for help.
•
Diagnosing LED Indicators: The switch can be monitored through the LED
indicators on the front panel of the switch. The LED’s can help describes
common problems you may encounter and where you may find possible solutions,
to assist in identifying problems.
•
If the power indicators do not light on when power is applied, you may have a
problem with the power supply. Check for loose power connections, power losses
or surges at the power outlet.
•
If the switch LED’s represent normal operating mode and the cable connections
are correct and no data is transmitted or received through the switch, contact your
Network Administrator for network configuration and status help.
17 Manual Documentation Number EIR-SFP-T-0912M
www.bb-elec.com
www.bb-europe.com
Page 21
Technical Specifications
18
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
Technical Specification
Communications
Compatibility IEEE 802.3, 802.3u, 802.3ab
IEEE 802.3x, 802.3z
LAN 10/100/1000Base-T, 1000Base-FX
Transmission Speed Up to 1000 Mbps
Interface
Connectors 4 x RJ-45 (4-port 10/100/1000TX)
1 x SFP port (mini-GBIC port)
6-pin removable screw terminal (power
input & fault relay output)
Power Consumption 5.50W
Power Input 2 x Unregulated 12 to 48 VDC
Fault Output 1 Relay Output
Mechanism
Dimensions (WxDxH) 30 x 95 x 140 mm (1.2 x 3.7 x 5.5 in.)
Enclosure IP-30, Metal shell with solid
mounting kits
Mounting DIN rail 35mm or Wall/Panel
Page 22
Technical Specifications
19
Manual Document Number EIR-SFP-T-0912m
www.bb-elec.com
www.bb-europe.com
Protection
ESD (Ethernet) 4,000 VDC
Surge (EFT for power) 3,000 VDC
Reverse Power Yes
Overload current protection Yes
Environment
Operating Temperature -40 to 75oC (-40 to 167oF)
Operating Humidity 5% to 95% (non-condensing)
Storage Temperature -40 to 85oC (-40 to 185oF)
Certifications
Safety UL, cUL, CE EN60950-1
EMC FCC Class A,
CE EN61000-4-2 (ESD)
CE EN61000-4-3 (RS)
CE EN61000-4-4 (EFT)
CE EN61000-4-5 (Surge)
CE EN61000-4-6 (CS)
CE EN61000-4-8
CE EN61000-4-11
CE EN61000-4-12
CE EN61000-6-2
CE EN61000-6-4
Free Fall IEC60068-2-32
Shock IEC60068-2-27
Vibration IEC60068-2-6