B&B Electronics 858-18121 User Manual

IE-iMcV-MultiWay
Operation Manual
FCC Radio Frequency Interference Statement
Class A (
using 48V Telco type power)
This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which the user will be required to correct the interference at his own expense.
Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
The use of non-shielded I/O cables may not guarantee compliance with FCC RFI limits. This digital apparatus does not exceed the Class A
limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe A
prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
Class B (
using all other power options)
This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which the user will be required to correct the interference at his own expense.
Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
The use of non-shielded I/O cables may not guarantee compliance with FCC RFI limits. This digital apparatus does not exceed the Class B
limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe B
prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
Warranty
IMC Networks warrants to the original end-user purchaser that this product, EXCLUSIVE OF SOFTWARE, shall be free from defects in materials and workmanship under normal and proper use in accordance with IMC Networks' instructions and directions for a period of six (6) years after the original date of purchase. This warranty is subject to the limitations set forth below.
At its option, IMC Networks will repair or replace at no charge the product which proves to be defective within such warranty period. This limited warranty shall not apply if the IMC Networks product has been damaged by unreasonable use, accident, negligence, service or modification by anyone other than an authorized IMC Networks Service Technician or by any other causes unrelated to defective materials or workmanship. Any replaced or repaired products or parts carry a ninety (90) day warranty or the remainder of the initial warranty period, whichever is longer.
To receive in-warranty service, the defective product must be received at IMC Networks no later than the end of the warranty period. The product must be accompanied by proof of purchase, satisfactory to IMC Networks, denoting product serial number and purchase date, a written description of the defect and a Return Merchandise Authorization (RMA) number issued by IMC Networks. No products will be accepted by IMC Networks which do not have an RMA number. For an RMA number, contact IMC Networks at PHONE: (800) 624-1070 (in the U.S and Canada) or (949) 465-3000 or FAX: (949) 465-3020. The end-user shall return the defective product to IMC Networks, freight, customs and handling charges prepaid. End-user agrees to accept all liability for loss of or damages to the returned product during shipment. IMC Networks shall repair or replace the returned product, at its option, and return the repaired or new product to the end-user, freight prepaid, via method to be determined by IMC Networks. IMC Networks shall not be liable for any costs of procurement of substitute goods, loss of profits, or any incidental, consequential, and/or special damages of any kind resulting from a breach of any applicable express or implied warranty, breach of any obligation arising from breach of warranty, or otherwise with respect to the manufacture and sale of any IMC Networks product, whether or not IMC Networks has been advised of the possibility of such loss or damage.
EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE, IMC NETWORKS MAKES NO OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THIS IMC NETWORKS PRODUCT, INCLUDING WITHOUT LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED. IMC NETWORKS SHALL DISREGARD AND NOT BE BOUND BY ANY REPRESENTATIONS OR WARRANTIES MADE BY ANY OTHER PERSON, INCLUDING EMPLOYEES, DISTRIBUTORS, RESELLERS OR DEALERS OF IMC NETWORKS, WHICH ARE INCONSISTENT WITH THE WARRANTY SET FORTH ABOVE. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED TO THE DURATION OF THE EXPRESS WARRANTY STATED ABOVE.
Every reasonable effort has been made to ensure that IMC Networks product manuals and promotional materials accurately describe IMC Networks product specifications and capabilities at the time of publication. However, because of ongoing improvements and updating of IMC Networks products, IMC Networks cannot guarantee the accuracy of printed materials after the date of publication and disclaims liability for changes, errors or omissions.
ii
Table of Contents
FCC Radio Frequency Interference Statement ........................................................... ii
Warranty................................................................................................................... ii
About the IE-iMcV-MultiWay ....................................................................................1
Operations, Administration and Maintenance (OAM) ............................................3
iView² Management Software ...................................................................................4
iView2 (iConfig view) .............................................................................................4
Installing an IE-iMcV-MultiWay .................................................................................5
DIP Switch Selectable Mode Configuration ...............................................................6
Mini-Serial Port ......................................................................................................... 7
LED Operation.......................................................................................................... 8
Autocross Feature for Twisted Pair Connections ....................................................8
Configuration ............................................................................................................ 8
Configuration Options...........................................................................................9
Basic Device Configuration Using the CLI............................................................10
Saved and Current Values ...............................................................................11
Command List ................................................................................................11
Assigning IP Information..................................................................................11
Password Protection for Serial Port Connections..............................................11
Assigning SNMP Trap Destinations ..................................................................12
Removing Trap Destinations............................................................................12
Creating Community Strings............................................................................12
Deleting Community Strings............................................................................13
Ending the Session ..........................................................................................13
Rebooting the Unit .........................................................................................13
Enabling/Disabling DHCP................................................................................13
Commands List (Space Bar) .................................................................................14
Cleandb..........................................................................................................15
Downloading Files ..........................................................................................15
Accounts.........................................................................................................16
VLAN Configuration........................................................................................16
Bandwidth (bw) ..............................................................................................19
Version ...........................................................................................................21
Viewing Port Statistics (ifstats) ..........................................................................22
Viewing Port RMON Statistics (rmstats)............................................................22
System Description (sysDescr) .........................................................................23
Reboot............................................................................................................23
(Operation and Administration Management) OAM ........................................23
Viewing SFP Statistics (sfpstats) ........................................................................24
Unit ................................................................................................................24
Port Configuration (port) .................................................................................25
iii
Using iView2........................................................................................................... 27
Unit Configuration ..........................................................................................28
Port Configuration...........................................................................................29
Bandwidth ......................................................................................................29
Tables .............................................................................................................30
VLAN..............................................................................................................31
Advanced .......................................................................................................32
OAM AH ........................................................................................................33
Loopback Testing ............................................................................................34
OAM CFM......................................................................................................36
Agent Info.......................................................................................................41
Connecting the IE-iMcV-MultiWay to an iMcV-Giga-FiberLinX-II.............................42
Configuration File Save/Restore Function.................................................................42
Saving a Configuration File to Disk: ......................................................................... 43
Uploading a Saved Configuration File through iView2 (iConfig view)........................45
SFP Ports................................................................................................................. 46
RJ-45 Data Port Pinout........................................................................................47
RS-232 Serial Console Port..................................................................................47
Product Applications ...............................................................................................48
Glossary ..................................................................................................................49
Troubleshooting ......................................................................................................51
Specifications .......................................................................................................... 52
IMC Networks Technical Support............................................................................52
Fiber Optic Cleaning Guidelines..............................................................................53
Electrostatic Discharge Precautions..........................................................................54
Safety Certifications................................................................................................. 55
iv
About the IE-iMcV-MultiWay
The IE-iMcV-MultiWay is an SNMP manageable modular device providing two fixed 10/100/1000Base-T copper ports and 2 SFP ports. The SFP ports support fiber or copper SFPs. As a plug and play device, the IE-iMcV-MultiWay provides several distinct modes of operation to support a wide range of applications. The IE-iMcV­MultiWay provides OAM functionality with 802.3ah (LINK-OAM ah) and 802.1ag (SERVICE-OAM ag) supported on each port. It supports jumbo frame sizes of up to 10,240 bytes as well as AutoCross on the copper ports. As an Industrial Ethernet device, it supports an extended temperature range of -40°C to +85°C. A console port and a DIP Switch bay provide configuration options.
The IE-iMcV-MultiWay module is a single-wide module. It can be installed in the following chassis:
• MediaChassis series
• IE-MediaChassis series
• iMediaChassis series
The IE-iMcV-MultiWay requires two small form-factor (SFP) modules which provide greater flexibility in the network environment. The hot-swappable nature of the SFPs, available in dual strand for Multi Mode and Single Mode, and single strand fiber types for Single Mode, allow for easy configuration and future upgrading as network demands evolve. The SFP modules must be MSA-compliant and both DDMI and non-DDMI are supported. The fiber SFP can support 100Mbps or 1000Mbps; while the copper SFPs support 10/100/1000Mbps and 1000Mbps.
SFPs are sold separately by IMC Networks and meet Class 1 Laser Safety Standard.
IE-iMcV-MultiWay Features and Configuration
The IE-iMcV-MultiWay offers a full feature set including Auto Negotiation, Selective Advertising, AutoCross, VLANs, SNMP management, loopback testing and OAM. Unit
2
software updates can be downloaded through TFTP or iView
(iConfig view).
IE-iMcV-MultiWay features include:
• SNMP manageable
• OAM AH
o
IEEE 802.3ah Link OAM for per port monitoring (OAM AH)
1
• OAM AH Functions
o
Discovery
o
Link Performance Monitoring
o
Remote Loopback
o
Fault Detection
o
Link Fault
o
Dying Gasp
o
Critical Event
• OAM CFM (SERVICE-OAM)
o
IEEE 802.1ag Connectivity Fault Management (OAM CFM)
o
OAM CFM Functions
o
Continuity Check
o
Loopback
• Speed/duplex modes
• 802.1q VLAN
• Extra tagging with user-defined VLAN tag Ethertype
• Ethertype 88A8 as defined in 802.1ad
• Command Line Interface capable (CLI)
• Telnet
• Password assignment via CLI, Telnet or iView²
• DIP Switch configuration for Modes
• Bandwidth Limiting
The IE-iMcV-MultiWay can be installed as a standalone CPE device, back to back, or as a Remote when connected to an iMcV-Giga-FiberLinX-II configured as a Host.
As a CPE device, the IE-iMcV-MultiWay can behave as a remote to an iMcV-Giga­FiberLinX-II host when:
1) The iMcV-Giga-FiberLinX-II:
• Is connected via the SFP ports on the IE-iMcV-MultiWay
• Is configured as a Host
• Uses firmware version A1 860-00D1 or higher
2) The SNMP card (if present):
• Uses SNMP firmware version 953-00D0 or higher
3) The IE-iMcV-MultiWay:
• Uses firmware version 123-00A1 or higher
2
When using iView
, the IE-iMcV-MultiWay can be fully managed without an IP address using a secure management channel. However, an IP address can be assigned through iView2 (iConfig view), the CLI or Telnet using the default IP address of 10.10.10.10.
2
Operations, Administration and Maintenance (OAM)
OAM is a general term used in network management and is typically applied to a series of standard protocols for installing, monitoring, and troubleshooting Metropolitan Area Networks.
When applied to Ethernet – OAM is typically assumed to refer to the layer 2 (MAC layer), management protocols, specifically 802.3ah and 802.1ag. Layer 2 management protocols do not need higher level transport protocols to operate, OAM data is transferred in standard multicast Ethernet frames.
802.3ah OAM:
(LINK-OAM)
802.1ag:
(SERVICE-OAM)
Is a point-to-point protocol designed to verify a specific link between two directly connected devices (over copper or fiber), which support 802.3ah OAM. One device must be configured to be an active OAM device, the other a passive (typically the core switch would be the active device, the end device passive).
802.3ah OAM provides link status, remote fault detection and the ability to initiate a loopback circuit.
Often referred to as Connectivity Fault Management (CFM), is an end-to-end protocol designed to verify a specific network path between two devices that may well be in different geographical locations. CFM allows the network operator to administer, monitor and debug the network using continuity check (a heart beat message), link trace (similar to traceroot, but operating at the MAC layer) and finally loopback (can be likened to a layer 2 ping).
3
iView² Management Software
iView² is the IMC Networks management software that features a Graphical User Interface (GUI) and gives network managers the ability to monitor and control the manageable IMC Networks products.
iView² is available in several versions, including a WebServer version 3.0, and can also function as a snap-in module for HP OpenView Network Node Manager and other third party SNMP Management software. For assistance in selecting the right version of iView² for a specific operating system, please visit:
http://www.imcnetworks.com/products/iview2.cfm
2
iView
supports the following platforms:
• Windows 2000
• Windows XP
• Windows Vista
• Windows 7
Please see the SNMP Management Module manual for software configuration options.
iView2 (iConfig view)
iView2 (iConfig view) is an in-band utility created by IMC Networks, used for SNMP configuration for IMC Networks’ SNMP-manageable devices.
2
The iView
(iConfig view) feature allows the following to be performed:
• Set an IP address, subnet mask and default gateway
• Define community strings and SNMP Traps
2
iView
(iConfig view) also includes an authorized IP address system and restricted access to MIB groups which are supported by IMC Networks’ manageable devices. These extra layers of security do not affect SNMP compatibility. iView
2
(iConfig view) can upload new versions of the system software and new MIB information. It also includes diagnostic capabilities for faster resolution of technical support issues.
4
Installing an IE-iMcV-MultiWay
IE-iMcV-MultiWay can be installed in IMC networks’ unmanaged MediaChassis, IE­MediaChassis series, or the iMediaChassis series.
To install an IE-iMcV-MultiWay
Remove the blank bracket covering the slot where the module is to be
1. installed by removing the screws on the outside edges of the bracket.
Slide the iMcV-Modules into the chassis, via the cardguides, until the
2. module is seated securely in the connector.
Secure the module to the chassis by tightening the captive screws.
3.
Save any “blanks” removed during installation for future use if the
4. configuration requirements change.
5
DIP Switch Selectable Mode Configuration
The IE-iMcV-MultiWay can be configured in one of the following ways via DIP Switch settings (see page
Error! Bookmark not defined.
):
Configuration
Method
4-Port Switch (default)
Dual Converter mode
1+1 SFP Protection Non-Revertive mode
Description
In this mode, the unit acts as a standard 4-port MAC-layer switch.
In this mode, the unit functions as two independent (SFP to TX) media converters and traffic never passes between the two converters.
In this mode, the "SFP A" port (fiber or copper) is connected through the switch to the drop ports as the main link. The "SFP B" port (fiber or copper) is active into the MAC switch, but no connection inside the switch is made; in this way, the "SFP B" line is held as the standby line. The "SFP B" line is held in the LINK state for testing and line verification, but does not actively carry user data.
When a fault is detected on the active line, all customer traffic is switched to the “SFP B” port. With non-Revertive mode data is not resumed by “SFP A” port until SFP B fails or is disconnected.
1+1 SFP Protection Revertive mode
In this mode, the "SFP A" port (fiber or copper) is connected through the switch to the drop ports as the main link. The "SFP B" port (fiber or copper) is active into the MAC switch, but no connection inside the switch is made; in this way, the "SFP B" line is held as the standby line. The "SFP B" line is held in the LINK state for testing and line verification, but does not actively carry user data.
When a fault is detected on the active line, all customer traffic is switched to the “SFP B” port. Once the “A” port is no longer in a fault condition, data is resumed on that port.
NOTE
Revertive and Non-Revertive modes can only operate on the ports with SFPs, not the fixed copper ports.
6
DIP
Switch
1 Dual Enable dual channel OFF 2 1+1 Provides 1+1 protection with non-revertive switching OFF 3 1+1 Revert Provides 1+1 protection with revertive switching OFF 4 LoSpd B Force SFP "B" for low-speed operation OFF 5 LoSpd A Force SFP "A" for low-speed operation OFF 6 Reserved
Name Description Default
Setting
Mini-Serial Port
A console port, located at the top of the faceplate, allows the customer to use a local RS-232 serial interface for management. A special mini-jack to DB9-F cable is provided with the product for direct connection to a PC serial port.
NOTE
To log on through the serial port, set the computer/terminal for VT-100 emulation, with: 38.4K baud, 8 data bits, 1 stop bit, no parity, no FlowControl.
7
LED Operation
Each IE-iMcV-MultiWay includes SFP and RJ-45 LEDs.
(TX 1, TX 2)
LNK/ACT
FDX
SFP A, SFP B
OAM
ACTIVE
LNK
FLT
Glows green when a link is established on the TX port; blinks green when activity is detected on the TX port.
Glows yellow when a link is established on the TX port; blinks green when activity is detected on the TX port.
Glows green when an active OAM AH channel is established.
Serial Port
Glows green when the port is active OFF when SFP is in standby (does not indicate
activity)
Glows green with a valid optical link.
Glows amber when a fault is detected.
Autocross Feature for Twisted Pair Connections
All fixed twisted pair ports on the IE-iMcV-MultiWay include AutoCross, a feature that automatically selects between a crossover workstation and a straight-through connection depending on the connected device.
Configuration
The IE-iMcV-MultiWay includes many features that are configurable via a serial/Telnet session (CLI) or through iView² (SNMP Management view or iConfig view).
8
Configuration Options
The following options are configurable through both the iView2 (iConfig view) and Serial/Telnet.
Feature iView² Serial/Telnet
9
Loopback Auto Negotiation Force Mode FlowControl VLANs IP Address Subnet Mask Default Gateway MIB Community Traps Assignment Users Passwords Access Level Reboot Frame size selection Bandwidth Limiting
9 9 9 9 9 9 9 9 9 9 9 9 9 9 9
9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9
The following table presents management options configurable via iView2 (iConfig view) or a serial/Telnet session.
9 9
9 9
2
Serial/Telnet
9
9
9
9
Feature iView
(iConfig)
PROM Software Download/Upload Telnet Session Software Download Setup (TFTP) DHCP Restore Configuration Save Configuration
9
Basic Device Configuration Using the CLI
After running through an initial self test, the screen will display the following message:
Enter
Press
for Device Configuration.
Enter
Press
to open the main configuration screen. This screen allows the user to set the IP address and the destination IP address for traps with the community string, read/write access and password as usual.
Saved Values. (These values will be active after reboot) IP Address - 10.10.10.10
Subnet Mask - 255.255.255.0 DHCP is Not Active Default Gateway - 0.0.0.0
Current Values. (These values are in use now) IP Address - 10.10.10.10 Subnet Mask - 255.255.255.0 Default Gateway - 0.0.0.0
Community String: public Access: r/w Press I to enter new saved parameter values. Press P to change Password.
Press T to enter new Trap Destination. Press K to remove All Trap Destinations. Press C to enter new Community String. Press U to remove All Community Strings. Press E to End session. Type REBOOT to reboot unit. Press D for DHCP On/Off. Press SpaceBar for additional commands.
10
This screen contains the following information and options:
Saved and Current Values
Saved values display the changes made during the current session and current values display the values currently in use:
IP Address (IP address of SNMP agent)
Subnet Mask (mask to define IP subnet to which agent is connected) Default Gateway (default router for IP traffic outside of the subnet)
Command List
I
= Enter new
P
= Change the
T
= Enter new
K
= Remove
C
= Create
U
= Delete All
E
=
End
the session*
Reboot D
= Reboot the unit (may result in short data loss)
= Enable or disable
Space Bar
Saved Parameter Values
Password
*
Trap Destinations
All Trap Destinations
SNMP Community Strings
SNMP Community Strings
DHCP
= Opens the device specific configuration options screen.
*
The screens illustrated in this manual show capabilities for users with Admin rights. Individuals with User-level rights can only view port status and port settings, change their password, end a session, and reboot the unit.
NOTE
It is necessary to reboot the IEiMcV--MultiWay after making any modifications to the Saved Values for the changes to take effect. To reboot, type Configuration screen.
Reboot
at the prompt on the Main
Assigning IP Information
To modify the Saved Parameter Values (i.e., assign IP address and subnet mask), press
I
. The system prompts for the IP address and subnet mask for the connected
Enter
device. Press
Enter
to skip. When finished, press
after each entry. A default gateway can also be assigned, or press
Enter
, then type
reboot
for changes to take effect. The Current Values can only be saved and acted on after the IE-iMcV­MultiWay has been successfully rebooted.
Password Protection for Serial Port Connections
Password/username is not offered for the serial port by default. This allows the end user to quickly access the device for some basic configuration capability. Password protection is provided for the serial configuration process by pressing
P
on the main
configuration screen. Enter a password, keeping in mind that passwords are case-
11
sensitive and must not exceed eight characters or include spaces, and press
Enter
. This password will be requested whenever logging on. To remove password protection, select
P
and, instead of entering a password, press
Enter
.
Passwords have the following requirements:
The password must be between 1 and 8 characters long
The password consists of a combination of any ASCII characters except spaces
Passwords are case sensitive
Passwords are a way to make the management of the IMC Networks devices secure, but these password lists must be stored and maintained.
Assigning SNMP Trap Destinations
Traps are sent by the manageable device to a management PC when a certain event takes place. To enter a trap destination, press
T
. When prompted, enter a New IP
Address prompt, enter the appropriate IP address of the destination device and press
Enter
. Then, type the name of the community string (that the destination device has
been configured to accept) and press
Enter
version 1 or 2c and press
. This function enables ALL of the device traps.
Supported traps include: Link Down, Link Up, and Last Gasp.
Enter
. Select whether the trap is for SNMP
Removing Trap Destinations
To remove all trap destinations, press K. Press Y to continue to confirm or N to abort
Enter
and remove all trap destinations. Press
to finish.
This function will delete all trap destinations. To selectively delete trap destinations or to disable/enable Traps, use iView
2
(iConfig view) to configure
the device.
Creating Community Strings
Community strings add a level of security to a network. The default community string is named "public" and has read/write access. For security, "public" should be replaced with custom community strings such as ones created with read-only access (for general use), and another with read/write access (for the administrator).
C
To create a new community string, go to the main configuration screen and press
.
Enter the name of the new community (up to 16 characters, no spaces) and press
Enter
. Then type one of the following to assign the community string’s access rights:
R
= read-only access
W
= read/write access
Enter
= abort
After entering
R
or W, press
Enter
. To finish, press
12
Enter
and reboot.
Deleting Community Strings
To delete all community strings, perform the following:
Press
U
. The "Are you sure you want to delete all future strings?" prompt is displayed.
Y
Press Press
when prompted to proceed and delete all community strings, N to abort.
Enter
to finish.
This function will delete ALL community strings. To selectively delete community
2
strings, use iView
(iConfig view) to configure the device.
Ending the Session
Press E to end a serial port or Telnet/HyperTerminal session before disconnecting the serial cable. This will stop the continuous stream of data to the serial port.
Rebooting the Unit
To reboot the IE-iMcV-MultiWay, type
reboot
from the main screen or the command
menu.
Enabling/Disabling DHCP
To toggle DHCP on the IE-iMcV-MultiWay between enable and disable, press D and then
Y.
Press the
Space Bar
once to return to the main screen without making any
changes.
DHCP Disable
(Static IP Addressing)
DHCP is disabled in the default configuration. Initially, modules are assigned a Static default IP Address of 10.10.10.10. Changes to the Static IP Address can be added
2
manually through iView
(iConfig view) or a Console session. The changes will be
initiated following reboot of the module.
DHCP Enable
(Dynamic IP Addressing)
If a DHCP server is present on the network and DHCP is enabled, the DHCP client will initiate a dialogue with the server during the boot up sequence. The server will then issue an IP address to the management card. Once the new IP address is received, the SNMP Management Module will reboot so that the new IP address will take effect. Refer to About Serial Port Configuration for more information about Enabling/Disabling DHCP.
When there is no DHCP server on the network, use the serial configuration to manually set the IP addresses.
When DHCP is enabled, the IP address (default 10.10.10.10 or a previously used IP address, or user-configured) is saved. When DHCP is disabled, the saved IP address will be reinstated and the device will reboot.
DHCP servers give out lease times: devices renew their leases based on the administrator-specified time. If a device cannot renew its lease, and the lease expires, the device will be given the IP address 10.10.10.10 and will reboot.
13
Commands List (Space Bar)
The IE-iMcV-MultiWay also includes several device-specific options. To access these options, press the
Space Bar
the action to be performed (as shown below) and press
from the Main Configuration screen, type the name of
Enter
.
Command Description
cleandb
download
accounts
vlan
bw
version
ifstats
rmstats
sysDescr
reboot
Reboots the unit with a clean database. This removes all information from the database and sets the unit to factory defaults.
Downloads firmware via the TFTP protocol
Allows the addition for User, Superuser, Admin
Provides selection of two modes of operation to support all VLAN configurations.
Displays settings for Bandwidth configuration
Displays the unit’s firmware and hardware version
Displays interface statistics
Displays remote monitoring (RMON) statistics on packets received as defined in RFC 2819 for RMON.
Allows the editing of sysName, sysDescr, and Port information
Allows a soft reboot of the unit after changes are made by the end user
oam
sfpstats
Enable/disable OAM
Provides information about the wavelength, serial number, output power,
14
Loading...