IMC Networks warrants to the original end-user purchaser that this product, EXCLUSIVE OF SOFTWARE, shall be free
from defects in materials and workmanship under normal and proper use in accordance with IMC Networks' instructions
and directions for a period of six (6) years after the original date of purchase. This warranty is subject to the limitations set
forth below.
At its option, IMC Networks will repair or replace at no charge the product which proves to be defective within such
warranty period. This limited warranty shall not apply if the IMC Networks product has been damaged by unreasonable
use, accident, negligence, service or modification by anyone other than an authorized IMC Networks Service Technician
or by any other causes unrelated to defective materials or workmanship. Any replaced or repaired products or parts carry
a ninety (90) day warranty or the remainder of the initial warranty period, whichever is longer.
To receive in-warranty service, the defective product must be received at IMC Networks no later than the end of the
warranty period. The product must be accompanied by proof of purchase, satisfactory to IMC Networks, denoting
product serial number and purchase date, a written description of the defect and a Return Merchandise Authorization
(RMA) number issued by IMC Networks. No products will be accepted by IMC Networks which do not have an RMA
number. For an RMA number, contact IMC Networks at PHONE: (800) 624-1070 (in the U.S and Canada) or (949) 4653000 or FAX: (949) 465-3020. The end-user shall return the defective product to IMC Networks, freight, customs and
handling charges prepaid. End-user agrees to accept all liability for loss of or damages to the returned product during
shipment. IMC Networks shall repair or replace the returned product, at its option, and return the repaired or new
product to the end-user, freight prepaid, via method to be determined by IMC Networks. IMC Networks shall not be
liable for any costs of procurement of substitute goods, loss of profits, or any incidental, consequential, and/or special
damages of any kind resulting from a breach of any applicable express or implied warranty, breach of any obligation
arising from breach of warranty, or otherwise with respect to the manufacture and sale of any IMC Networks product,
whether or not IMC Networks has been advised of the possibility of such loss or damage.
EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE, IMC NETWORKS MAKES NO OTHER WARRANTIES,
WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THIS IMC NETWORKS PRODUCT, INCLUDING WITHOUT
LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED. IMC NETWORKS SHALL DISREGARD AND NOT BE
BOUND BY ANY REPRESENTATIONS OR WARRANTIES MADE BY ANY OTHER PERSON, INCLUDING EMPLOYEES,
DISTRIBUTORS, RESELLERS OR DEALERS OF IMC NETWORKS, WHICH ARE
INCONSISTENT WITH THE WARRANTY SET FORTH ABOVE. ALL IMPLIED WARRANTIES INCLUDING THOSE OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED TO THE DURATION OF THE
EXPRESS WARRANTY STATED ABOVE.
Every reasonable effort has been made to ensure that IMC Networks product manuals and promotional materials
accurately describe IMC Networks product specifications and capabilities at the time of publication. However, because of
ongoing improvements and updating of IMC Networks products, IMC Networks cannot guarantee the accuracy of printed
materials after the date of publication and disclaims liability for changes, errors or omissions.
The IE-iMcV-MuxDemux/4 is a dual wide module that provides 4 channels of
CWDM (Coarse Wavelength Division Multiplexing), an expansion port to allow
existing 1310sm fiber, in order to cascade additional units, and a network port. For
customers deploying high-end gigabit switches, the IE-iMcV-MuxDemux/4can
provide the growing need for greater bandwidth on fiber. This Industrial Ethernet
module has an extended temperature of -40C to +85C.
1470nm Fiber Port 1550nm Fiber Port
1490nm Fiber Port 1570nm Fiber Port
1510nm Fiber Port 1590nm Fiber Port
1530nm Fiber Port 1610nm Fiber Port
Expansion Port to Daisy Chain
Multiple Mux
Network Port Network Port
Expansion Port to Daisy Chain
Multiple Mux
Common Application
1
Installing an iMcV-Module
The IE-iMcV-MuxDemux/4 installs in IMC Networks’ iMediaChassis series or in any
MediaChassis/2. It occupies 2 slots as it is dual wide.
The IE-iMcV-MuxDemux/4 can be installed in a 2 slot unmanaged chassis:
• IE-MediaChassis/2-AC
• IE-MediaChassis2-DC
• MediaChassis/2-AC
• MediaChassis/2-DC
• MuxDemuxChassis/2
NOTE
All modules are hot-swappable.
To install an IE-iMcV-MuxDemux/4
1.
Remove the blank bracket covering the slot where the module is to be installed
by removing the screws on the outside edges of the bracket.
Slide the IE-iMcV-MuxDemux/4 into the chassis, via the cardguides, until the
2.
module is seated securely in the connector.
3.
Secure the module to the chassis by tightening the captive screw.
Save any “blanks” removed during installation for future use if the configuration
4.
requirements change.
5.
The MuxDemuxChassis/2 is a 2 slot chassis without a power supply, as the IEiMcV-MuxDemux/4 does not require power to function.
2
Connecting the IE-iMcV-MuxDemux/4
Ports 1-4
Port 5
Port 5
Network
Port
The IE-iMcV-MuxDemux/4 allows 4 devices of differing wavelengths,
transmits the wavelengths along a single fiber, then separates the
wavelengths, enabling the fiber optic receivers to receive a signal of
the correct wavelength.
Port 5 is an expansion port to allow multiple IE-iMcV-MuxDemux/4
to be daisy chained, or to carry a legacy 1310nm SM fiber link.
This port allows two IE-iMcV-MuxDemux/4 to be connected back to
back there are no diagnostic LEDs for the IE-iMcV-MuxDemux/4.
3
Specifications
Fiber Optic (Insert Loss)
3.0dB for CWDM systems using an optical band between 1450nm and 1610nm
NOTE
Unit does not require power to operate!
Operating Temperature
-40°F to +185°F (-40°C to +85°C)
Storage Temperature
-40°F to +185°F (-40°C to +85°C)
Humidity
5 to 95% (non-condensing); 0 to 10,000 ft. altitude
Dimensions
Dual-wide, two slot chassis module
4
IMC Networks Technical Support
Tel:
+32-16-550880 (Europe)
Fax:
E-Mail:
Web:
(949) 465-3000 or (800) 624-1070 (in the U.S. and Canada);
(949) 465-3020
techsupport@imcnetworks.com
www.imcnetworks.com
5
Fiber Optic Cleaning Guidelines
Fiber Optic transmitters and receivers are extremely susceptible to contamination by
particles of dirt or dust, which can obstruct the optic path and cause performance
degradation. Good system performance requires clean optics and connector ferrules.
Use fiber patch cords (or connectors, if you terminate your own fiber) only from
1.
a reputable supplier; low-quality components can cause many hard-to-diagnose
problems in an installation.
Dust caps are installed at IMC Networks to ensure factory-clean optical devices.
2.
These protective caps should not be removed until the moment of connecting
the fiber cable to the device. Should it be necessary to disconnect the fiber
device, reinstall the protective dust caps.
Store spare caps in a dust-free environment such as a sealed plastic bag or box
3.
so that when reinstalled they do not introduce any contamination to the optics.
4.
If you suspect that the optics have been contaminated, alternate between
blasting with clean, dry, compressed air and flushing with methanol to remove
particles of dirt.
6
Electrostatic Discharge Precautions
Electrostatic discharge (ESD) can cause damage to any product, add-in modules or
stand alone units, containing electronic components. Always observe the following
precautions when installing or handling these kinds of products
Do not remove unit from its protective packaging until ready to install.
1.
Wear an ESD wrist grounding strap before handling any module or component.
2.
If the wrist strap is not available, maintain grounded contact with the system unit
throughout any procedure requiring ESD protection.
Hold the units by the edges; do not touch the electronic components or gold
3.
connectors.
4.
After removal, always place the boards on a grounded, static-free surface, ESD
pad or in a proper ESD bag. Do not slide the modules or stand alone units over
any surface.
WARNING!
extremely susceptible to electrostatic discharge damage. Do not
handle these components directly unless you are a qualified service
technician and use tools and techniques that conform to accepted
industry practices.
Integrated circuits and fiber optic components are
7
Certifications
European Directive 2002/96/EC (WEEE) requires that any equipment that bears this
symbol on product or packaging must not be disposed of with unsorted municipal
waste. This symbol indicates that the equipment should be disposed of separately
from regular household waste. It is the consumer’s responsibility to dispose of this
and all equipment so marked through designated collection facilities appointed by
government or local authorities. Following these steps through proper disposal and
recycling will help prevent potential negative consequences to the environment and
human health. For more detailed information about proper disposal, please contact
local authorities, waste disposal services, or the point of purchase for this equipment.
The information in this document is subject to change without notice. IMC Networks assumes no responsibility for any
errors that may appear in this document. IE-iMcV-MuxDemux/4 is a trademark of IMC Networks. Other brands or
product names may be trademarks and are the property of their respective companies.
Document Number 44-80131-00 A1 January 2012
Loading...