BBC Bircher RFGate 2.2.S, RFGate 2.1, RFGate 2.2.S.F Translation Of Original Operating Instructions

189
50.8
4.8
189
50.8
189
50.8
4.8
i
i
290260G
i
i
10/18
RFGate 2.1
Wireless signal transmission system for safety edges
Translation of original operating instructions
General
Transmitter Receiver
138
175
175
138
ENGLISH
175
138
10.8
4.8
10.8
1 Safety instructions
Warning: Switch off the operating voltage before working on the
system. Only trained, qualied personnel may perform installation
and startup. The unit may only be repaired by the manufacturer. The switching unit may only be used to protect against dangers on crushing and shearing points and on automatic industrial doors and gates (intended use). National and international regulations on industrial door and gate safety must be complied with. Always
2 Common application
2.1 Site entrance gate
Up to 10 transmitters can be linked with the same receiver
Transmitter
Receiver
10.8
consider the safety functions of your application as a whole, never just in relation to one individual section of the system. The installer is responsible for carrying out a risk assessment and installing the industrial door system correctly.
It is recommended to change the batteries every year.
Transmitters and receivers (also among each others) must be at least 0.5 m apart.
Transmitter
2032
+
Safety edges
8.2kΩ
Safety edges
1
i
ON
1 2
ON
1 2
TEST
TEST
3 Transmitter
i
3.1 DIP switch setting according to sensor (safety edge, switch contact)
RFGate 2.2.S RFGate 2.2.S.F
DIP switch Sensor connection DIP switch Sensor connection DIP switch Sensor connection DIP switch Sensor connection
ON
IN1
2)
comon
IN2
ON
IN1
2)
comon
IN2
ON
IN1
2)
IN2
ON
IN1
2)
IN2
1 2
8K2 8K2
1)
Change from NC to NO, see chapter 3.2
2)
IN2 has no function
1 2
1)
1 2
1 2
1)
3.2 Change input from NC to NO (factory setting = NC)
1. Remove all batteries
4. Change
2. Insert battery 1
> 1.5 sec.
Press button on
transmitter
1
2032
Observe
the sequence
NC
Status
changes
3.
+
NO
After inserting the battery 1, you have 10 seconds to change the logic
5. Insert battery 2
LED
ashes
2
2032
+
6.
2032
Change
+
stored
Status
NC 2x
LED
ashes 2x
NO 5x
LED
ashes 5x
4 Receiver
4.1 Wiring: Power supply and test inputs
VCC1
VCC2
COM
OUT
SOUT
TEST
C B S
+/~ –/~
12/24V AC/DC Test
+/~ –/~
12/24V AC/DC
VCC1
VCC2
C B S
COM
OUT
SOUT
TEST
Test
open collector
4.3 DIP switches
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
*
Safety application
standard according to EN ISO 13849-1
inactive ➔ no safety function! (Radio connection is not monitored)
Transmission frequency
869.85 MHz: Set DIP-switch before pairing transmitter – receiver
4.2 Wiring: Outputs and control
Relay contacts are shown unpowered
8K2
C B S
Gate control
8.2 kOhm input
Status Terminals
Sensor not activated (operating mode) 8K2 closed Sensor activated (security system activated) closed open No supply voltage closed open Transmitter and receiver not paired closed open Broken cable between sensor and transmitter closed open Transmitter batteries low closed open
8K2
C B S
Gate control
with
NC input
C – B
Terminals
C – S
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
* = factory setting
868.95 MHz:
*
Set DIP-switch before pairing transmitter – receiver
Test input type
NC activated = contact open
NO
*
activated = contact closed
Automatic frequency adjustment
active used only in case of radio disturbances
inactive
*
2
i
i
5 Start-up
1. Check DIP switch settings
4. Transmitter: insert batteries
6. Transmitter: install
8. System test of safety edge on gate
6 Programming
ON
1 2
1
ON
1 2
2032
+
Observe
order
ON
2
1 2 3 4
ON
1 2
+
2032
2032
+
2. Install and wire receiver
5. Programming (Chapter 6.1): pair transmitter with receiver
7. Transmitter: wire
3. Turn on power supply
ON
Transmitters and receivers (also among each others) must be at
i
least 0.5 m apart.
Please observe the torque when fastening the cover: Max. 45 N cm
OK?
6.1. RFGate 2.1, pairing transmitter with receiver
ON
Transmitters and receivers (also among
1 2 3 4
1. On the receiver
2. On the transmitter
each others) must be at least 0.5 m apart.
> 1.5 sec.
Beep
Press
button
Beep
Release
button
On the receiver
Press and
release button
6.2 Clear pairings
On the receiver
> 1.5 sec. > 3 sec.
Beep
LED
lights up
Beep Beep
Beep Wait 2
Beep Beep Beep
10 sec.
beeps
2x
10 sec.
Code saved
LED goes out
Beep
All pairings deleted
2x
Press
button and hold
Keep pressed
the button
Short beeps Beep WaitRelease
button
2
beeps
6.3 Memory full
Beep 10 sec.
3
ON
REL21
7 Standard operation
7.1 Receiver LED indicators
1234
SELECT
LED
LED on
Safety
OK
LED off
Object
detected
8 Technical data
Receiver
Supply voltage 12/24 V ACDC Transmitter memory 10 Output 1 relay 24 V, 1 A; micro switch-off 1B Power consumption 0.5 W @ 12 V; 1.2 W @ 24 V Test signal input See page 2, chapter 4.1, I = 3 mA
switching threshold: off = 0.6 V / on = 1.8 V
Transmitter
Battery power 2 x Lithium 3 V Type CR2032 Power consumption Transmitting: 17 mA standby: 16 µA
7.2 Warning indicator for low battery voltage
Beep
Battery voltage
low
Receiver: Signal sounds at each activation
4x
System
Frequency bands 868.95 MHz & 869.85 MHz Range under optimum conditions up to 100 m Protection class IEC
IP55
60529 Pollution degree 2 Working temperature -20 °C to +55 °C
9 EU Declaration of Conformity
See attachment
10 WEEE
Devices with this symbol must be treated separately during disposal. This must be done in accordance with the laws of the respective countries for environmentally sound disposal, processing and recycling of electrical and electronic equipment.
11 Contact
BBC Bircher Smart Access, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com
Designed in Switzerland / Made in EU
4