Installation and Operations Manual — VP Gate Operator 2
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of non-insulated "dangerous voltage" within the
product's enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instruction in the
literature accompanying the product.
Your safety is extremely important to us. If you have any
questions or are in doubt about any aspect of the equipment,
please contact us.
Introduction
Welcome!
Congratulations on your purchase of a B&B ARMR Vertical Pivot (VP) gate operator. In
addition to providing detailed operating instructions, this manual describes how to install,
maintain, and troubleshoot your operator. If you require additional assistance with any aspect of
installation or operation, please contact us.
Safety
SYMBOL MEANING:
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 3
Important Safety Information
TO REDUCE THE RISK OF SERIOUS INJURY OR DEATH, READ AND
FOLLOW ALL INSTRUCTIONS PROVIDED IN THIS MANUAL.
1. Hydraulic slide gate operators are intended for vehicular use only. Pedestrians
should use a separate walkthrough entrance designed for on-foot traffic.
2. Keep children away from gate movement area and off the gate operator. Never
let children operate or play with gate controls.
3. Install all warning signs provided with the gate operator so that they are
clearly visible from both sides of the gate.
4. It is the responsibility of the specifier, designer, purchaser, installer and end-
user to ensure the gate system is properly configured for its intended
application.
5. Use the emergency manual release only when the gate is not in motion.
6. Test gate operator and all related safety devices monthly. The gate must
reverse or stop when a safety device is tripped. The gate must stop upon
sensing a second sequential safety violation before reaching a limit switch. If
the gate utilizes a transmitting device on a safety edge, check the battery on a
regular basis to ensure proper operation. Failure to adjust and re-test the gate
operator properly can increase the risk of injury.
7. This gate operator utilizes a pumping system which contains hydraulic fluid.
Consult local EPA (Environmental Protection Agency) regulations for
damming requirements (if any) around the base of the gate operator.
8. Service and maintenance of the gate operator should be performed on a routine
basis by a qualified technician. Attempts to service the gate equipment by nonqualified personnel could result in serious injury and will void all applicable
warranties.
SAVE THESE INSTRUCTIONS.
THIS MANUAL SHOULD BE LEFT WITH A RESPONSIBLE INDIVIDUAL AT THE
INSTALLATION SITE AND KEPT IN A DESIGNATED LOCATION FOR
MAINTENANCE OR TROUBLESHOOTING OPERATIONS
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 4
How to Contact Us
If you have any questions or experience any problems with your vehicle barrier—or if we can
help you with any other facility security issues—please contact us directly at:
Corporate/Tech Support:
B&B ARMR
5900 S. Lake Forest Drive, Suite 230
McKinney, TX 75070 USA
Telephone: (972) 385-7899
Toll Free: (800) 367-0387
Fax: (972) 385-9887
E-mail: info@bb-armr.com
techsupport@bb-armr.com
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 5
How to Contact Us ................................................................................................................... 4
1 General Description .......................................................................................................... 6
2 Features ............................................................................................................................. 7
3 Models Available ............................................................................................................... 8
4 Setting User Parameters on PLC ...................................................................................... 9
4.1 Setting The Date And Time (optional, not required) ....................................................................................... 9
4.2 Setting The Max Run Timer ............................................................................................................................. 9
4.3 Turning ON / OFF The Timer To Close ........................................................................................................ 10
4.4 Setting The Timer To Close ........................................................................................................................... 10
4.5 Setting The Inherent Safety ........................................................................................................................... 11
5.1 Test Run the Operator ................................................................................................................................... 11
6.1 Test Peripheral/Safety Devices ..................................................................................................................... 14
6.2 Final Adjustments.......................................................................................................................................... 15
7 The Interface Board ......................................................................................................... 16
9.1 General Parts Breakdown ............................................................................................................................. 19
Equipment Maintenance Log Form ....................................................................................... 27
11 Warranty Information ...................................................................................................... 28
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 6
1 General Description
The B&B ARMR VP series gate operators are designed to reliably operate any style gate
panel up to 24 feet long and 8 feet high, allowing for an additional 1 foot of barbed wire.
Common applications include automatic operation of commercial and residential entry
gates, condo and subdivision access control gates and airport security gates. The operator
is durable under heavy use in both commercial and residential installations. The design
incorporates a number of excellent features intended to improve safety and security,
increase reliability and reduce maintenance.
Controls operate on safe and reliable 24VAC voltage (24VDC on Fail Safe and Battery
Backup units). A transformer, completely prewired, is installed in each operator to step
down the input voltage.
The operator actuates the gate by using a hydraulic cylinder, causing the gate panel to
pivot upright on a sturdy pivot shaft, mounted on a series of pillow blocks. The gate panel
is bolted to the frame which is welded to the pivot shaft, which allows for easy servicing or
replacing of the gate panel should such an event become necessary.
Rotation direction (open or close) is determined by the hydraulic valve system, not by the
direction of the electric motor rotation. This independence from electric motor rotation
results in several advantages. Gate travel can be instantly reversed. And because this can
be accomplished with changing the motor rotation, brakes are not required.
B&B’s warranty reflects confidence in the commitment to the quality of the products. VP
operators carry a 2 year factory warranty, the best available.
B&B ARMR is a subsidiary of B&B Roadway and Security Solutions. B&B was founded
in 1926 and has built its reputation over the years on responsive customer service and the
highest quality products. B&B is proud of its reputation and strives to continually renew it
with each operator it manufactures.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 7
Remote pushbutton station(s)
Loop detector
Single button control
Auto exit
Obstruction detector
Emergency open
Autoclose timer
Radio control
Master/slave control
Warning light/buzzer
2 Features
Safe 24VAC controls standard (24VDC on Fail Safe and Battery Backup units)
Low maintenance – no sprockets, chains, brakes, or springs to adjust
Prewired PLC board with many built in features and plug in options, eliminates complex
and confusing internal circuit wiring
Wide range of control options, including but not limited to combinations of:
Gate panel can be designed to match road gradient
Complete easy reference wiring diagrams for all standard control options
Built in adjustable maximum run timer
Instant reverse capability during close cycle for safety and obstruction detection
Inherent safety
115/208/230 single phase and 208/230/440 three phase units available
Continuous duty capability
Rigid steel channel pivot frame for easy gate panel mounting
No chains to cut or pins to remove, increases security
Pry resistance – hydraulic cylinder automatically locked when unit is de-energized
Clearly illustrated installation, maintenance and troubleshooting instructions
Bypass valve quick action release for manual operation
Limited 2 year factory warranty
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 8
3 Models Available
VP
Standard model
Rotation speed: 90° to open in under 10 seconds
Recommended gate opening: up to 24 feet long
“B” Models
Battery Backup model
Rotation speed: 90° to open in under 10 seconds
Recommended gate opening: up to 24 feet long
Maintains normal operation during power failures
Primary power of 115 & 240VAC single phase only
Gate Panel Configuration
Amplimesh
Chain link
Ornamental picket
Custom
Other Gate Operator Models
B&B also manufactures the VL series of Vertical Lift gate operators, LXL series slide gate
operators, CF series of Correctional Facility gate operators as well as related crash rated
barriers and arms, and is continually developing new products.
Contact the factory or an authorized representative of B&B for additional information.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 9
1. Turn power on. Date and time will be
flashing. Press the ESC key.
2. This is the main menu. Use the UP
and DOWN arrow keys to select ‘Set
Clock’, and press the OK button.
3. Press OK again. A cursor flashes
under the parameter to be changed.
4. Use the UP and DOWN arrow keys
to change the value. Use the LEFT
and RIGHT arrow keys to move
between lines.
5. Press OK when finished.
NOTE: *Time format is military time
only.
1. From the main menu, select ‘Set
Param’.
2. Use the UP arrow to scroll to the
MAX RUN screen and press OK.
3. Press OK again to activate cursor.
4. Use the arrow keys to set the desired
time.
5. Press OK to save
>Stop
Set Param
Set Clock
Prg Name
Set Clock
Su 00:00
YYYY-MM-DD
2003-01-01
MAX RUN
T =20:00
Ta=00:00
Bottom number
shows elapsed time.
4 Setting User Parameters on PLC
4.1 Setting The Date And Time (optional, not required)
4.2 Setting The Max Run Timer
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 10
With the unit powered down and the gate
in the closed position, locate the supplied
3 button control station and do the
following (in order):
1. Press and hold the STOP button
2. While holding the STOP button,
press and hold the CLOSE
button.
3. While holding the STOP and
CLOSE buttons, press and
release the OPEN button.
4. Release the CLOSE button, then
the STOP button.
5. Trigger the open limit switch. If
the timer is on, you will see the
screen to the left.
6. Repeat step 1 to toggle the timer
off
NOTE: The AutoClose screen will not be
visible if the timer is turned off
There is a 3 minute window with which
to turn the timer to close on or off each
time the operator power is turned on.
1. From the main menu, select ‘Set
Param’.
2. Use the UP arrow to scroll to the
AUTO CLS screen and press OK.
3. Press OK again to activate cursor.
Use the arrow keys to set the desired
time.
4. Press OK to save
Note: s = seconds, m = minutes, h =
hours
AutoClose
Activated
00:00s
00:00s
Bottom number
shows elapsedtime.
CLOSE
OPEN
STOP
AutoCLS
T =20:00s
Ta = 00:00
Bottom number shows
elapsed time.
4.3 Turning ON / OFF The Timer To Close
4.4 Setting The Timer To Close
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 11
1. Press the ESC button to return to the
main menu.
2. Open and Close the operator using
the 3 button control station. The
screen on the left will appear.
3. While the gate is running, pay
attention to the SYSTEM PRESS
value. This is the amount of pressure
required to move the gate.
4. Stop the gate operator and press the
ESC button to enter the main menu.
5. Select ‘Set Param’ and use the UP
arrow key to scroll to SAFE PSI.
6. Press OK to activate the cursor.
Enter the On value (SYSTEM
PRESS+30), then the Off value (On-
10).
7. Press OK to save and return to the
main menu.
LXL V1.20
MX RN 20:00s
SYSTEM
PRESS 125
SAFE PSI
On = 155
Off = 145
Ax = 125
4.5 Setting The Inherent Safety
5 Initial Operation
5.1 Test Run the Operator
1. Make sure the counterweights are installed.
2. Verify the Yoke is installed
3. Make sure the power switch is ON
4. Hit the Open button on the printed circuit board, or pushbutton control panel.
5. Verify the gate opens to full open. The limit switch should stop the gate automatically,
however if the motor is still operating and the gate is fully open, stop the gate by pressing
the Stop button on the printed circuit board, pressing Stop pushbutton control panel, or by
turning the power switch off.
6. If necessary make any adjustment to the open limit switch.
NOTE: While the gate is in the up position, the bolts for the bottom side of the gate
panel can be installed.
NOTE: If the primary power is three phase and the motor ran, but the gate did not move
to the open position, reverse two poles (swap to wires) of the three phase primary power.
7. Hit the Close button on the printed circuit board or pushbutton control panel
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 12
8. Verify the gate closes completely. The limit switch should stop the gate automatically,
however if the motor is still operating and the gate is fully closed, stop the gate by pressing
the Stop button on the printed circuit board, pressing Stop pushbutton control panel, or by
turning the power switch off.
9. If necessary make adjustments to the close limit
NOTE: Some air may have become trapped in the hydraulic cylinder and/or lines and may
cause the gate panel to “come down hard”. With use, this air should eventually be removed
by the system. Another cause of the “come down hard” may be the limit switch adjustment.
10. After making adjustments run the gate a couple of time to verify satisfactory operation.
11. You are now ready to install any peripheral/secondary safety devices.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 13
6 Connecting Peripheral Devices
Connecting safety devices to the secondary safety connectors will stop the gate on the detection
of the safety and proceed in the event of clearing the safety. To reverse the gate on the event of a
safety, you must connect the safety device to the loopsafe terminal on connector 3.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 14
6.1 Test Peripheral/Safety Devices
1. Open the gate
2. Close the gate, and test the installed devices.
Note: If the safety device is wired in the IR Beam connectors on the printed circuit board
(conn 5 and conn 7), the gate will stop the close command until the safety is cleared and
then continue to close. If the device is wired to the loopsafe on conn3, the gate will stop
and reverse back to the fully open position until the safety is cleared.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 15
6.2 Final Adjustments
With the gate opening and closing properly and the installed safety devices have been tested, you
can make adjustment to the operation of the system.
1. Adjusting MaxRun Time. Max run time is the time from which the operator has been given
a command to open or close and when the appropriate limit switch is made or a safety is
encountered.
1. Open or Close the gate and time how long it takes to perform the successful operation.
2. Adjust the MaxRun Time in the Set Parm (section 5). It is recommended that round up in
increments of 5 seconds to the next time. Ie. Measured time is 16 seconds, set max run
to 20 seconds.
2. Adjust AutoClose time. If you are utilizing adjust the autoclose time to the desired time
(section 5)
3. Adjust the Inherent Pressure (section 5)
4. Verify a positive gate stop (the yoke) is installed. It should be located 1 to 2 inches from the
end of the gate panel
5. Warning signs should be mounted in a visible location per applicable safety codes
instructing personnel and traffic to maintain a safe distance clear of gate path
6. Record the names and phone numbers of the dealer, installer and other important contact is
the manual for future reference.
7. Leave the manual along with all supplements with the owner. Have them keep them in a
place that is readily available if needed.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 16
ESC
OK
7 The Interface Board
1 24VAC/24VDC auxiliary power
2 Processor/Controller
3 Built-in 3 button station
4 Position indication and power loss relays
5 Secondary safety device connections
6 Control inputs (open devices, safety loops, etc.)
7 Input power for control board
8 Contactor output
9 1 amp fuse (processor protection)
10 Factory connections
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 17
8 Maintenance
Here is a list of items that should be checked on a routine basis.
Check for loose or broken fasteners - This check should also include the fasteners on
the gate panel. A broken fastener on the gate panel could cause undue stress on the
operator. Also, inspect the anchor bolts that hold the gate operator in position. While
inspecting these bolts, check for signs the operator has “walked” out of its original
mounting position.
Cycle test the operator - Run the gate through several cycles to confirm that there is no
binding of the gate panel and that the drive rail is properly aligned with the gate operator.
Also, monitor the wheels for slippage. If the wheels slip, tighten down on the spring
adjustment nut until no slippage occurs during normal gate travel. Tighten the spring only
enough to eliminate slippage during normal travel.
Remove the vent cap and check the hydraulic fluid level -The vent cap is located on
the reservoir assembly (bottom right of the operator). After removing the vent plug, a
visual inspection should show the fluid level approximately 1” below the vent plug. If
fluid needs to be added, please contact the factory.
IMPORTANT NOTE: All B&B ARMR operators ship with Envirologic 132 hydraulic
fluid, a biodegradable vegetable based fluid. If another hydraulic fluid is substituted; the
existing fluid must be drained to avoid mixing. Never mix hydraulic fluids!
Check for leaks in the hydraulic system - This includes the hydraulic lines, reservoir
and fittings. Leakage may occur in the fittings after a period use. If this happens,
moderate tightening of the hose fittings should stop the leakage. If the leak persists,
replace the leaking hose assembly. NOTE: It is recommended that the hydraulic fluid be
replaced at every 1-2 years if installation is high cycle (>300/day), or every 2-4 years if
cycles are < 200/day.
Check for loose or frayed wires - Carefully inspect all input and output connections to
ensure all wires are seated properly in the terminal blocks. A loose or frayed wire can
create different “phantom” problems.
Check gate input devices for proper operation - These devices include push buttons,
keypads, loops, etc. An improperly functioning input device could give the impression
the gate operator is malfunctioning.
Test all safety devices for proper operation - Test the inherent safety to ensure the gate
reverses after coming in contact with an obstruction. Adjust the parameter if needed.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 18
9 Appendix
Note for electrical components such as transformers or motors your voltage and phase may
change the part number required
.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Electrical cubical
Installation and Operations Manual — VP Gate Operator 19
9.1 General Parts Breakdown
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 20
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 21
LOGO!
12/24 RC
SIEMENS
OK
ESC
DM8 12/24R
RUN/STOP
6ED1
055-1MB00-0BA1
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 22
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 23
LOGO!
12/24 RC
SIEMENS
OK
ESC
DM8 12/24R
RUN/STOP
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 24
10 Troubleshooting
The table below provides a general guidance on identifying and correcting any problems with
your VP Series gate operator. If you encounter problems that you cannot fix, contact B&B
ARMR and we will gladly work with you to correct them.
10.1 Alarm Definitions –
Continuous solid beep – Gate is moving or a Stop command is active
5sec On, 1sec Off – MaxRun Time Error
1sec On, 1sec Off – Forward and/or Reverse Safety
0.25sec On, 0.5sec Off – Inherent Safety Error
10.2 PLC Input/Output Definitions –
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 25
Symptom
Actions
Gate operator does
not respond when
commanded.
1. Check CONN 9 for power when command is given.
2. Check overload protector
3. Check PLC output.
4. Check that safeties are clear, and that IR Beams are aligned.
5. Check PLC input.
6. Check the +24VDC at CONN3 pins 8 and 10
Operator drives gate
too slowly.
1. Check for any binding of the gate.
2. Check the fluid level in the reservoir.
3. Check the quality of the hydraulic fluid. Old fluid will
become sludgy and clogging of internal filter is possible.
MAX Runtime Error
1. Check for any binding of the gate.
2. Check the fluid level in the reservoir.
3. Check the MAX RUN TIME setting in Parameters to insure
sufficient time is set for the gate size.
Date and time flash
on the PLC.
1. Refer to step 4.11 of Installing and Programming the LXL
Operator for setting the date and time. (Optional, not
required to be set)
Gate does not stop
automatically when
encountering an
obstacle.
1. Refer to step 4.15 of Installing and Programming the LXL
Operator for setting the Inherent Safety.
2. Check for system pressure on Inherent Safety screen of the
PLC, if no reading is evident while gate is running suspect a
faulty pressure transducer.
1. Check for incorrect incoming power to the Printed Circuit
Board (PCB).
2. Ensure all external devices are sending the correct voltage
to the PCB, and that there are no shorts.
PLC says Stop/Reset
activated.
1. If using an external push button, ensure that the stop button
is a normally closed contact.
2. If not using an external push button, ensure there is a
jumper wire between stop/reset and +24 stp/rst on CONN 3.
3. Check the connection of the wire between the J1Pin 9
connector and I7 of the PLC.
4. Verify shunt is present on JP1 between pins 1 and 2.
5. Check F3.
Electric Motor turns
but gate does not
move.
1. Check the fluid level in the reservoir.
2. Check PLC outputs to see if Q1 turns on for an OPEN
and/or Q2 turns on for a CLOSE.
3. Check for loose coupling between the electric motor and
pump assembly.
4. Check for voltage between COM and HYD VAL 1 and 2 on
CONN 1 of PCB, and ensure wires connections are tight.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 26
Symptom
Actions
5. If voltage is correct, manually shift the detent in the center
of the solenoid on either side of the hydraulic valve, if
wheels move suspect hydraulic valve.
6. If unit is a 3 phase unit and a new installation, reverse two
of the incoming power leads.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 27
Date
Performed By
Checklist
Complete
Anomalies
Notes
Jan
Yes No
Feb
Yes No
Mar
Yes No
Apr
Yes No
May
Yes No
Jun
Yes No
Jul
Yes No
Aug
Yes No
Sep
Yes No
Oct
Yes No
Nov
Yes No
Year
Yes No
Date
Performed By
Checklist
Complete
Anomalies
Notes
Jan
Yes No
Feb
Yes No
Mar
Yes No
Apr
Yes No
May
Yes No
Jun
Yes No
Jul
Yes No
Aug
Yes No
Sep
Yes No
Oct
Yes No
Nov
Yes No
Year
Yes No
Equipment Maintenance Log Form
Product Type:____________________
Location:________________________
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Installation and Operations Manual — VP Gate Operator 28
11 Warranty Information
B&B-ARMR warranties for a period of one (1) year, after delivery F.O.B. plant, unless
otherwise specified by Supplier, from failure of operation in ordinary use and against defects due
to faulty material or workmanship. Any defective equipment in the Barrier shall be returned to
the factory, at Supplier’s option, for repair or replacement, and Supplier assumes no
responsibility for service at any consumer site. Supplier is in no event responsible for any labor
costs under the warranty. Subject to the above limitation, all service, parts, and replacements
necessary to maintain the equipment as warranted shall be furnished by the end user. Supplier
shall not have any liability under these specifications, other than for repair or replacement as
described above for equipment malfunction or equipment failure of any kind, caused for any
reason, including, but not limited to unauthorized repairs, improper installation, installation not
performed by Supplier personnel, nor by Supplier authorized personnel, failure to perform
neglect, natural disaster, act of God or if at any time the power supplied to any part of the
Security Barrier falls short or exceeds the rate of tolerance for the equipment.
Replacement parts shipped from B&B ARMR, are warranted for 90 days after shipment.
Replacement parts are subject to the same warranty terms as stated above.
Drive wheels are considered normal wear parts and are not covered under this warranty except in cases
of manufacturer defects.
The exclusive remedy for breach of any warranty by Supplier shall be the repair or replacement
at supplier’s option, of any defects in the equipment. IN NO EVENT SHALL THE SUPPLIER
OF SECURITY BARRIER BE LIABLE FOR CONSEQUENTIAL OR SPECIAL DAMAGES
OR ANY KIND OF DAMAGES TO ANYONE. Except as provided herein, Supplier makes no
warranties or representations to consumer or to anyone else and consumer hereby waives all
liability against Supplier as well as any other person for the design, manufacture, sale,
installation, and/or servicing of the Security Barrier.
THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES
EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. NO OTHER
WARRANTIES EXIST.
Any modification or alteration by anyone other than B&B-ARMR will render the warranty
herein as null and void.
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.